WAGO 750-88X and WAGO 750-89X Ethernet Controller devices, versions 01.09.18(13) and before, have XSS in the SNMP configuration via the webserv/cplcfg/snmp.ssi SNMP_DESC or SNMP_LOC_SNMP_CONT field. WAGO 750-881 Ethernet Controller The device contains a cross-site scripting vulnerability.Information may be obtained and information may be altered. WAGO750-881EthernetControllerdevices is an Ethernet controller device from WAGO, Germany. The remote attacker can use the SNMP_DESC or SNMP_LOC_SNMP_CONT field to inject any web script or HTML. The vulnerability stems from the lack of correct validation of client data in WEB applications. An attacker could exploit this vulnerability to execute client code

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201810-1044",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "750-881 ethernet controller devices",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "wago",
        "version": "01.09.18\\(13\\)"
      },
      {
        "model": "750-881 ethernet controller devices",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "wago",
        "version": "01.08.01\\(10\\)"
      },
      {
        "model": "750-881 ethernet controller device",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "wago",
        "version": "01.09.18(13)"
      },
      {
        "model": "ethernet controller",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "wago",
        "version": "750-881\u003c=01.09.18(13)"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-21245"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011237"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-16210"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-676"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:wago:wago_750-881_ethernet_controller_devices_firmware:01.08.01\\(10\\):*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:wago:wago_750-881_ethernet_controller_devices_firmware:01.09.18\\(13\\):*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:wago:wago_750-881_ethernet_controller_devices:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-16210"
      }
    ]
  },
  "cve": "CVE-2018-16210",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.6,
            "impactScore": 2.9,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": true,
            "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Medium",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 4.3,
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2018-16210",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 6.4,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2018-21245",
            "impactScore": 4.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.6,
            "id": "VHN-126547",
            "impactScore": 2.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:M/AU:N/C:N/I:P/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "NONE",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 2.8,
            "impactScore": 2.7,
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "trust": 1.0,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.0"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 6.1,
            "baseSeverity": "Medium",
            "confidentialityImpact": "Low",
            "exploitabilityScore": null,
            "id": "CVE-2018-16210",
            "impactScore": null,
            "integrityImpact": "Low",
            "privilegesRequired": "None",
            "scope": "Changed",
            "trust": 0.8,
            "userInteraction": "Required",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2018-16210",
            "trust": 1.8,
            "value": "MEDIUM"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2018-21245",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201810-676",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "VULHUB",
            "id": "VHN-126547",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-21245"
      },
      {
        "db": "VULHUB",
        "id": "VHN-126547"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011237"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-16210"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-676"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "WAGO 750-88X and WAGO 750-89X Ethernet Controller devices, versions 01.09.18(13) and before, have XSS in the SNMP configuration via the webserv/cplcfg/snmp.ssi SNMP_DESC or SNMP_LOC_SNMP_CONT field. WAGO 750-881 Ethernet Controller The device contains a cross-site scripting vulnerability.Information may be obtained and information may be altered. WAGO750-881EthernetControllerdevices is an Ethernet controller device from WAGO, Germany. The remote attacker can use the SNMP_DESC or SNMP_LOC_SNMP_CONT field to inject any web script or HTML. The vulnerability stems from the lack of correct validation of client data in WEB applications. An attacker could exploit this vulnerability to execute client code",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-16210"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011237"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-21245"
      },
      {
        "db": "VULHUB",
        "id": "VHN-126547"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "EXPLOIT-DB",
        "id": "45581",
        "trust": 3.1
      },
      {
        "db": "NVD",
        "id": "CVE-2018-16210",
        "trust": 3.1
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011237",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-676",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-21245",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-126547",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-21245"
      },
      {
        "db": "VULHUB",
        "id": "VHN-126547"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011237"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-16210"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-676"
      }
    ]
  },
  "id": "VAR-201810-1044",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-21245"
      },
      {
        "db": "VULHUB",
        "id": "VHN-126547"
      }
    ],
    "trust": 1.5253968133333333
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-21245"
      }
    ]
  },
  "last_update_date": "2023-12-18T12:43:50.265000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "\u30c8\u30c3\u30d7\u30da\u30fc\u30b8",
        "trust": 0.8,
        "url": "http://global.wago.com/jp/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011237"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-79",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-126547"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011237"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-16210"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://www.exploit-db.com/exploits/45581/"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-16210"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-16210"
      },
      {
        "trust": 0.6,
        "url": "https://www.exploit-db.com/exploits/45581"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-21245"
      },
      {
        "db": "VULHUB",
        "id": "VHN-126547"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011237"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-16210"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-676"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-21245"
      },
      {
        "db": "VULHUB",
        "id": "VHN-126547"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011237"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-16210"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-676"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-10-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-21245"
      },
      {
        "date": "2018-10-12T00:00:00",
        "db": "VULHUB",
        "id": "VHN-126547"
      },
      {
        "date": "2019-01-09T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-011237"
      },
      {
        "date": "2018-10-12T22:15:07.377000",
        "db": "NVD",
        "id": "CVE-2018-16210"
      },
      {
        "date": "2018-10-15T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-676"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-10-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-21245"
      },
      {
        "date": "2019-05-13T00:00:00",
        "db": "VULHUB",
        "id": "VHN-126547"
      },
      {
        "date": "2019-01-09T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-011237"
      },
      {
        "date": "2019-05-13T13:29:01.370000",
        "db": "NVD",
        "id": "CVE-2018-16210"
      },
      {
        "date": "2019-05-21T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201810-676"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-676"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "WAGO 750-881 Ethernet Controller Device Cross-Site Scripting Vulnerability",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-21245"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-011237"
      }
    ],
    "trust": 1.4
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "XSS",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201810-676"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…