VAR-201811-0349
Vulnerability from variot - Updated: 2023-12-18 12:00VT-Designer Version 2.1.7.31 is vulnerable by the program reading the contents of a file (which is already in memory) into another heap-based buffer, which may cause the program to crash or allow remote code execution. VT-Designer Contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of INVT VT-Designer. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the processing of pm3 files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. INVT Electric VT-Designer is a graphics development tool from China's INVT Electric Company. A heap buffer overflow vulnerability exists in INVT Electric VT-Designer version 2.1.7.31. Failed exploit attempts will likely result in denial-of-service conditions. INVT Electric VT-Designer 2.1.7.31 is vulnerable; other versions may also be affected
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201811-0349",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "vt-designer",
"scope": "eq",
"trust": 1.6,
"vendor": "invt",
"version": "2.1.7.31"
},
{
"model": "electric vt-designer",
"scope": "eq",
"trust": 0.9,
"vendor": "invt",
"version": "2.1.7.31"
},
{
"model": "vt designer",
"scope": "eq",
"trust": 0.8,
"vendor": "invt electric",
"version": "2.1.7.31"
},
{
"model": "vt-designer",
"scope": null,
"trust": 0.7,
"vendor": "invt",
"version": null
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "vt designer",
"version": "2.1.7.31"
}
],
"sources": [
{
"db": "IVD",
"id": "7d7d7a12-463f-11e9-90a3-000c29342cb1"
},
{
"db": "ZDI",
"id": "ZDI-18-1360"
},
{
"db": "CNVD",
"id": "CNVD-2018-24486"
},
{
"db": "BID",
"id": "106071"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-012626"
},
{
"db": "NVD",
"id": "CVE-2018-18983"
},
{
"db": "CNNVD",
"id": "CNNVD-201811-916"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:invt:vt-designer:2.1.7.31:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2018-18983"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Ariele Caltabiano (kimiya)",
"sources": [
{
"db": "ZDI",
"id": "ZDI-18-1360"
}
],
"trust": 0.7
},
"cve": "CVE-2018-18983",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": null,
"accessComplexity": "Medium",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 6.8,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2018-18983",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 1.5,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": false,
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": true,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2018-24486",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "7d7d7a12-463f-11e9-90a3-000c29342cb1",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.2,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.9 [IVD]"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2018-18983",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2018-18983",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "ZDI",
"id": "CVE-2018-18983",
"trust": 0.7,
"value": "MEDIUM"
},
{
"author": "CNVD",
"id": "CNVD-2018-24486",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201811-916",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "IVD",
"id": "7d7d7a12-463f-11e9-90a3-000c29342cb1",
"trust": 0.2,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "7d7d7a12-463f-11e9-90a3-000c29342cb1"
},
{
"db": "ZDI",
"id": "ZDI-18-1360"
},
{
"db": "CNVD",
"id": "CNVD-2018-24486"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-012626"
},
{
"db": "NVD",
"id": "CVE-2018-18983"
},
{
"db": "CNNVD",
"id": "CNNVD-201811-916"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "VT-Designer Version 2.1.7.31 is vulnerable by the program reading the contents of a file (which is already in memory) into another heap-based buffer, which may cause the program to crash or allow remote code execution. VT-Designer Contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of INVT VT-Designer. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the processing of pm3 files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. INVT Electric VT-Designer is a graphics development tool from China\u0027s INVT Electric Company. A heap buffer overflow vulnerability exists in INVT Electric VT-Designer version 2.1.7.31. Failed exploit attempts will likely result in denial-of-service conditions. \nINVT Electric VT-Designer 2.1.7.31 is vulnerable; other versions may also be affected",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-18983"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-012626"
},
{
"db": "ZDI",
"id": "ZDI-18-1360"
},
{
"db": "CNVD",
"id": "CNVD-2018-24486"
},
{
"db": "BID",
"id": "106071"
},
{
"db": "IVD",
"id": "7d7d7a12-463f-11e9-90a3-000c29342cb1"
}
],
"trust": 3.24
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-18983",
"trust": 4.2
},
{
"db": "ICS CERT",
"id": "ICSA-18-333-01",
"trust": 3.3
},
{
"db": "BID",
"id": "106071",
"trust": 1.3
},
{
"db": "CNVD",
"id": "CNVD-2018-24486",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201811-916",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2018-012626",
"trust": 0.8
},
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-6414",
"trust": 0.7
},
{
"db": "ZDI",
"id": "ZDI-18-1360",
"trust": 0.7
},
{
"db": "IVD",
"id": "7D7D7A12-463F-11E9-90A3-000C29342CB1",
"trust": 0.2
}
],
"sources": [
{
"db": "IVD",
"id": "7d7d7a12-463f-11e9-90a3-000c29342cb1"
},
{
"db": "ZDI",
"id": "ZDI-18-1360"
},
{
"db": "CNVD",
"id": "CNVD-2018-24486"
},
{
"db": "BID",
"id": "106071"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-012626"
},
{
"db": "NVD",
"id": "CVE-2018-18983"
},
{
"db": "CNNVD",
"id": "CNNVD-201811-916"
}
]
},
"id": "VAR-201811-0349",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "7d7d7a12-463f-11e9-90a3-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-24486"
}
],
"trust": 1.65416665
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "7d7d7a12-463f-11e9-90a3-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-24486"
}
]
},
"last_update_date": "2023-12-18T12:00:53.446000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "https://www.invt.com/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-012626"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-119",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-012626"
},
{
"db": "NVD",
"id": "CVE-2018-18983"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.3,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-18-333-01"
},
{
"trust": 1.0,
"url": "http://www.securityfocus.com/bid/106071"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-18983"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-18983"
},
{
"trust": 0.3,
"url": "https://www.invt.com/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-24486"
},
{
"db": "BID",
"id": "106071"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-012626"
},
{
"db": "NVD",
"id": "CVE-2018-18983"
},
{
"db": "CNNVD",
"id": "CNNVD-201811-916"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "7d7d7a12-463f-11e9-90a3-000c29342cb1"
},
{
"db": "ZDI",
"id": "ZDI-18-1360"
},
{
"db": "CNVD",
"id": "CNVD-2018-24486"
},
{
"db": "BID",
"id": "106071"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-012626"
},
{
"db": "NVD",
"id": "CVE-2018-18983"
},
{
"db": "CNNVD",
"id": "CNNVD-201811-916"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-12-04T00:00:00",
"db": "IVD",
"id": "7d7d7a12-463f-11e9-90a3-000c29342cb1"
},
{
"date": "2018-11-26T00:00:00",
"db": "ZDI",
"id": "ZDI-18-1360"
},
{
"date": "2018-12-03T00:00:00",
"db": "CNVD",
"id": "CNVD-2018-24486"
},
{
"date": "2018-12-05T00:00:00",
"db": "BID",
"id": "106071"
},
{
"date": "2019-02-06T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-012626"
},
{
"date": "2018-11-30T18:29:00.490000",
"db": "NVD",
"id": "CVE-2018-18983"
},
{
"date": "2018-11-30T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201811-916"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-11-29T00:00:00",
"db": "ZDI",
"id": "ZDI-18-1360"
},
{
"date": "2018-12-10T00:00:00",
"db": "CNVD",
"id": "CNVD-2018-24486"
},
{
"date": "2018-12-05T00:00:00",
"db": "BID",
"id": "106071"
},
{
"date": "2019-02-06T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-012626"
},
{
"date": "2018-12-27T17:03:45.240000",
"db": "NVD",
"id": "CVE-2018-18983"
},
{
"date": "2018-12-03T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201811-916"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201811-916"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "INVT Electric VT-Designer Heap Buffer Overflow Vulnerability",
"sources": [
{
"db": "IVD",
"id": "7d7d7a12-463f-11e9-90a3-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-24486"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Buffer overflow",
"sources": [
{
"db": "IVD",
"id": "7d7d7a12-463f-11e9-90a3-000c29342cb1"
},
{
"db": "CNNVD",
"id": "CNNVD-201811-916"
}
],
"trust": 0.8
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.