VAR-201903-0179
Vulnerability from variot - Updated: 2023-12-18 13:08PSI GridConnect GmbH Telecontrol Gateway and Smart Telecontrol Unit family, IEC104 Security Proxy versions Telecontrol Gateway 3G Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway XS-MU Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway VM Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Smart Telecontrol Unit TCG Versions 5.0.27, 5.1.19, 6.0.16 and prior, and IEC104 Security Proxy Version 2.2.10 and prior The web application browser interprets input as active HTML, JavaScript, or VBScript, which could allow an attacker to execute arbitrary code. Multiple PSI GridConnect GmbH Products are prone to a cross-site scripting vulnerability because it fails to sanitize user-supplied input. An attacker may leverage this issue to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This may allow the attacker to steal cookie-based authentication credentials and launch other attacks. A remote attacker could exploit this vulnerability to execute arbitrary scripts
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201903-0179",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "telecontrol gateway 3g",
"scope": "gte",
"trust": 1.0,
"vendor": "psigridconnect",
"version": "5.1.21"
},
{
"model": "smart telecontrol unit tcg",
"scope": "gte",
"trust": 1.0,
"vendor": "psigridconnect",
"version": "5.1.21"
},
{
"model": "telecontrol gateway 3g",
"scope": "lt",
"trust": 1.0,
"vendor": "psigridconnect",
"version": "5.1.20"
},
{
"model": "telecontrol gateway vm",
"scope": "lte",
"trust": 1.0,
"vendor": "psigridconnect",
"version": "6.0.16"
},
{
"model": "telecontrol gateway vm",
"scope": "lt",
"trust": 1.0,
"vendor": "psigridconnect",
"version": "5.1.20"
},
{
"model": "telecontrol gateway xs-mu",
"scope": "gte",
"trust": 1.0,
"vendor": "psigridconnect",
"version": "5.1.21"
},
{
"model": "telecontrol gateway 3g",
"scope": "lt",
"trust": 1.0,
"vendor": "psigridconnect",
"version": "6.0.16"
},
{
"model": "smart telecontrol unit tcg",
"scope": "lt",
"trust": 1.0,
"vendor": "psigridconnect",
"version": "5.1.20"
},
{
"model": "telecontrol gateway xs-mu",
"scope": "lte",
"trust": 1.0,
"vendor": "psigridconnect",
"version": "6.0.16"
},
{
"model": "telecontrol gateway xs-mu",
"scope": "lt",
"trust": 1.0,
"vendor": "psigridconnect",
"version": "5.1.20"
},
{
"model": "smart telecontrol unit tcg",
"scope": "lt",
"trust": 1.0,
"vendor": "psigridconnect",
"version": "6.0.16"
},
{
"model": "telecontrol gateway vm",
"scope": "gte",
"trust": 1.0,
"vendor": "psigridconnect",
"version": "5.1.21"
},
{
"model": "iec104 security proxy",
"scope": "lte",
"trust": 1.0,
"vendor": "psigridconnect",
"version": "2.2.10"
},
{
"model": "iec104 security proxy",
"scope": "lte",
"trust": 0.8,
"vendor": "psi gridconnect",
"version": "2.2.10"
},
{
"model": "smart telecontrol unit tcg",
"scope": "lte",
"trust": 0.8,
"vendor": "psi gridconnect",
"version": "5.0.27"
},
{
"model": "smart telecontrol unit tcg",
"scope": "lte",
"trust": 0.8,
"vendor": "psi gridconnect",
"version": "5.1.19"
},
{
"model": "smart telecontrol unit tcg",
"scope": "lte",
"trust": 0.8,
"vendor": "psi gridconnect",
"version": "6.0.16"
},
{
"model": "telecontrol gateway 3g",
"scope": "lte",
"trust": 0.8,
"vendor": "psi gridconnect",
"version": "4.2.21"
},
{
"model": "telecontrol gateway 3g",
"scope": "lte",
"trust": 0.8,
"vendor": "psi gridconnect",
"version": "5.0.27"
},
{
"model": "telecontrol gateway 3g",
"scope": "lte",
"trust": 0.8,
"vendor": "psi gridconnect",
"version": "5.1.19"
},
{
"model": "telecontrol gateway 3g",
"scope": "lte",
"trust": 0.8,
"vendor": "psi gridconnect",
"version": "6.0.16"
},
{
"model": "telecontrol gateway vm",
"scope": "lte",
"trust": 0.8,
"vendor": "psi gridconnect",
"version": "4.2.21"
},
{
"model": "telecontrol gateway vm",
"scope": "lte",
"trust": 0.8,
"vendor": "psi gridconnect",
"version": "5.0.27"
},
{
"model": "telecontrol gateway vm",
"scope": "lte",
"trust": 0.8,
"vendor": "psi gridconnect",
"version": "5.1.19"
},
{
"model": "telecontrol gateway vm",
"scope": "lte",
"trust": 0.8,
"vendor": "psi gridconnect",
"version": "6.0.16"
},
{
"model": "telecontrol gateway xs-mu",
"scope": "lte",
"trust": 0.8,
"vendor": "psi gridconnect",
"version": "4.2.21"
},
{
"model": "telecontrol gateway xs-mu",
"scope": "lte",
"trust": 0.8,
"vendor": "psi gridconnect",
"version": "5.0.27"
},
{
"model": "telecontrol gateway xs-mu",
"scope": "lte",
"trust": 0.8,
"vendor": "psi gridconnect",
"version": "5.1.19"
},
{
"model": "telecontrol gateway xs-mu",
"scope": "lte",
"trust": 0.8,
"vendor": "psi gridconnect",
"version": "6.0.16"
},
{
"model": "telecontrol gateway xs-mu",
"scope": "eq",
"trust": 0.3,
"vendor": "psi gridconnect",
"version": "5.1.19"
},
{
"model": "telecontrol gateway xs-mu",
"scope": "eq",
"trust": 0.3,
"vendor": "psi gridconnect",
"version": "5.0.27"
},
{
"model": "telecontrol gateway xs-mu",
"scope": "eq",
"trust": 0.3,
"vendor": "psi gridconnect",
"version": "4.2.21"
},
{
"model": "telecontrol gateway vm",
"scope": "eq",
"trust": 0.3,
"vendor": "psi gridconnect",
"version": "6.0.16"
},
{
"model": "telecontrol gateway vm",
"scope": "eq",
"trust": 0.3,
"vendor": "psi gridconnect",
"version": "5.1.19"
},
{
"model": "telecontrol gateway vm",
"scope": "eq",
"trust": 0.3,
"vendor": "psi gridconnect",
"version": "5.0.27"
},
{
"model": "telecontrol gateway vm",
"scope": "eq",
"trust": 0.3,
"vendor": "psi gridconnect",
"version": "4.2.21"
},
{
"model": "telecontrol gateway 3g",
"scope": "eq",
"trust": 0.3,
"vendor": "psi gridconnect",
"version": "6.0.16"
},
{
"model": "telecontrol gateway 3g",
"scope": "eq",
"trust": 0.3,
"vendor": "psi gridconnect",
"version": "5.1.19"
},
{
"model": "telecontrol gateway 3g",
"scope": "eq",
"trust": 0.3,
"vendor": "psi gridconnect",
"version": "5.0.27"
},
{
"model": "telecontrol gateway 3g",
"scope": "eq",
"trust": 0.3,
"vendor": "psi gridconnect",
"version": "4.2.21"
},
{
"model": "telecontrol gateway 3g",
"scope": "eq",
"trust": 0.3,
"vendor": "psi gridconnect",
"version": "0"
},
{
"model": "smart telecontrol unit tcg",
"scope": "eq",
"trust": 0.3,
"vendor": "psi gridconnect",
"version": "6.0.16"
},
{
"model": "smart telecontrol unit tcg",
"scope": "eq",
"trust": 0.3,
"vendor": "psi gridconnect",
"version": "5.1.19"
},
{
"model": "smart telecontrol unit tcg",
"scope": "eq",
"trust": 0.3,
"vendor": "psi gridconnect",
"version": "5.0.27"
},
{
"model": "iec104 security proxy",
"scope": "eq",
"trust": 0.3,
"vendor": "psi gridconnect",
"version": "2.2.10"
},
{
"model": "telecontrol gateway xs-mu",
"scope": "ne",
"trust": 0.3,
"vendor": "psi gridconnect",
"version": "6.0.17"
},
{
"model": "telecontrol gateway xs-mu",
"scope": "ne",
"trust": 0.3,
"vendor": "psi gridconnect",
"version": "5.1.20"
},
{
"model": "telecontrol gateway vm",
"scope": "ne",
"trust": 0.3,
"vendor": "psi gridconnect",
"version": "6.0.17"
},
{
"model": "telecontrol gateway vm",
"scope": "ne",
"trust": 0.3,
"vendor": "psi gridconnect",
"version": "5.1.20"
},
{
"model": "telecontrol gateway 3g",
"scope": "ne",
"trust": 0.3,
"vendor": "psi gridconnect",
"version": "6.0.17"
},
{
"model": "telecontrol gateway 3g",
"scope": "ne",
"trust": 0.3,
"vendor": "psi gridconnect",
"version": "5.1.20"
},
{
"model": "smart telecontrol unit tcg",
"scope": "ne",
"trust": 0.3,
"vendor": "psi gridconnect",
"version": "6.0.17"
},
{
"model": "smart telecontrol unit tcg",
"scope": "ne",
"trust": 0.3,
"vendor": "psi gridconnect",
"version": "5.1.20"
},
{
"model": "iec104 security proxy",
"scope": "ne",
"trust": 0.3,
"vendor": "psi gridconnect",
"version": "2.2.11"
}
],
"sources": [
{
"db": "BID",
"id": "107201"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-002345"
},
{
"db": "NVD",
"id": "CVE-2019-6528"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:psigridconnect:telecontrol_gateway_xs-mu_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "6.0.16",
"versionStartIncluding": "5.1.21",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:psigridconnect:telecontrol_gateway_xs-mu_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.1.20",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:psigridconnect:telecontrol_gateway_xs-mu:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:psigridconnect:telecontrol_gateway_vm_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "6.0.16",
"versionStartIncluding": "5.1.21",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:psigridconnect:telecontrol_gateway_vm_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.1.20",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:psigridconnect:telecontrol_gateway_vm:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:psigridconnect:telecontrol_gateway_3g_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "6.0.16",
"versionStartIncluding": "5.1.21",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:psigridconnect:telecontrol_gateway_3g_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.1.20",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:psigridconnect:telecontrol_gateway_3g:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:psigridconnect:smart_telecontrol_unit_tcg_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.1.20",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:psigridconnect:smart_telecontrol_unit_tcg_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "6.0.16",
"versionStartIncluding": "5.1.21",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:psigridconnect:smart_telecontrol_unit_tcg:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:psigridconnect:iec104_security_proxy_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "2.2.10",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:psigridconnect:iec104_security_proxy:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2019-6528"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "M. Can Kurnaz,M. Can Kurnaz reported this vulnerability to NCCIC. NCCIC coordinated with BSI Germany.",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201902-1008"
}
],
"trust": 0.6
},
"cve": "CVE-2019-6528",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 6.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 6.5,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2019-6528",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 6.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"id": "VHN-157963",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:S/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2019-6528",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2019-6528",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201902-1008",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-157963",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-157963"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-002345"
},
{
"db": "NVD",
"id": "CVE-2019-6528"
},
{
"db": "CNNVD",
"id": "CNNVD-201902-1008"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "PSI GridConnect GmbH Telecontrol Gateway and Smart Telecontrol Unit family, IEC104 Security Proxy versions Telecontrol Gateway 3G Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway XS-MU Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway VM Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Smart Telecontrol Unit TCG Versions 5.0.27, 5.1.19, 6.0.16 and prior, and IEC104 Security Proxy Version 2.2.10 and prior The web application browser interprets input as active HTML, JavaScript, or VBScript, which could allow an attacker to execute arbitrary code. Multiple PSI GridConnect GmbH Products are prone to a cross-site scripting vulnerability because it fails to sanitize user-supplied input. \nAn attacker may leverage this issue to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This may allow the attacker to steal cookie-based authentication credentials and launch other attacks. A remote attacker could exploit this vulnerability to execute arbitrary scripts",
"sources": [
{
"db": "NVD",
"id": "CVE-2019-6528"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-002345"
},
{
"db": "BID",
"id": "107201"
},
{
"db": "VULHUB",
"id": "VHN-157963"
}
],
"trust": 1.98
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "ICS CERT",
"id": "ICSA-19-059-01",
"trust": 2.8
},
{
"db": "NVD",
"id": "CVE-2019-6528",
"trust": 2.8
},
{
"db": "BID",
"id": "107201",
"trust": 2.0
},
{
"db": "JVNDB",
"id": "JVNDB-2019-002345",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201902-1008",
"trust": 0.7
},
{
"db": "AUSCERT",
"id": "ESB-2019.0636",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-157963",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-157963"
},
{
"db": "BID",
"id": "107201"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-002345"
},
{
"db": "NVD",
"id": "CVE-2019-6528"
},
{
"db": "CNNVD",
"id": "CNNVD-201902-1008"
}
]
},
"id": "VAR-201903-0179",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-157963"
}
],
"trust": 0.01
},
"last_update_date": "2023-12-18T13:08:08.139000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "https://www.psigridconnect.com"
},
{
"title": "Multiple PSI GridConnect GmbH Fixes for product cross-site scripting vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=89710"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-002345"
},
{
"db": "CNNVD",
"id": "CNNVD-201902-1008"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-79",
"trust": 1.1
},
{
"problemtype": "CWE-20",
"trust": 0.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-157963"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-002345"
},
{
"db": "NVD",
"id": "CVE-2019-6528"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.8,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-19-059-01"
},
{
"trust": 2.3,
"url": "http://www.securityfocus.com/bid/107201"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2019-6528"
},
{
"trust": 0.9,
"url": "https://www.psigridconnect.com/en/home/"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-6528"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/76302"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-157963"
},
{
"db": "BID",
"id": "107201"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-002345"
},
{
"db": "NVD",
"id": "CVE-2019-6528"
},
{
"db": "CNNVD",
"id": "CNNVD-201902-1008"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-157963"
},
{
"db": "BID",
"id": "107201"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-002345"
},
{
"db": "NVD",
"id": "CVE-2019-6528"
},
{
"db": "CNNVD",
"id": "CNNVD-201902-1008"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-03-05T00:00:00",
"db": "VULHUB",
"id": "VHN-157963"
},
{
"date": "2019-02-28T00:00:00",
"db": "BID",
"id": "107201"
},
{
"date": "2019-04-08T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-002345"
},
{
"date": "2019-03-05T20:29:00.407000",
"db": "NVD",
"id": "CVE-2019-6528"
},
{
"date": "2019-02-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201902-1008"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-10-19T00:00:00",
"db": "VULHUB",
"id": "VHN-157963"
},
{
"date": "2019-02-28T00:00:00",
"db": "BID",
"id": "107201"
},
{
"date": "2019-04-08T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-002345"
},
{
"date": "2020-10-19T17:52:26.727000",
"db": "NVD",
"id": "CVE-2019-6528"
},
{
"date": "2020-10-22T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201902-1008"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201902-1008"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural PSI GridConnect GmbH Input validation vulnerabilities in products",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-002345"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "XSS",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201902-1008"
}
],
"trust": 0.6
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.