VAR-201903-1172
Vulnerability from variot - Updated: 2023-12-18 12:28PowerAct Pro Master Agent for Windows Version 5.13 and earlier allows authenticated attackers to bypass access restriction to alter or edit unauthorized files via unspecified vectors. PowerAct Pro Master Agent for Windows provided by OMRON SOCIAL SOLUTIONS Co.,Ltd. fails to restrict access permissions. Hosono, Akane reported this vulnerability to IPA. JPCERT/CC coordinated with the developer under Information Security Early Warning Partnership.A user with an Windows general user acccount may alter or edit a file which the user does not have a permission to access
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201903-1172",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "poweract pro master agent",
"scope": "lte",
"trust": 1.0,
"vendor": "omron",
"version": "5.13"
},
{
"model": "poweract pro master agent",
"scope": "lte",
"trust": 0.8,
"vendor": "omron social",
"version": "for windows version 5.13"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-000020"
},
{
"db": "NVD",
"id": "CVE-2018-16207"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:omron:poweract_pro_master_agent:*:*:*:*:*:windows:*:*",
"cpe_name": [],
"versionEndIncluding": "5.13",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2018-16207"
}
]
},
"cve": "CVE-2018-16207",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 4.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.0,
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Local",
"authentication": "Single",
"author": "IPA",
"availabilityImpact": "None",
"baseScore": 1.7,
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "JVNDB-2019-000020",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Low",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:L/AC:L/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "VULHUB",
"availabilityImpact": "NONE",
"baseScore": 4.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.0,
"id": "VHN-126543",
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:S/C:N/I:P/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "IPA",
"availabilityImpact": "None",
"baseScore": 3.3,
"baseSeverity": "Low",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "JVNDB-2019-000020",
"impactScore": null,
"integrityImpact": "Low",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2018-16207",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "IPA",
"id": "JVNDB-2019-000020",
"trust": 0.8,
"value": "Low"
},
{
"author": "CNNVD",
"id": "CNNVD-201903-1063",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "VULHUB",
"id": "VHN-126543",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-126543"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-000020"
},
{
"db": "NVD",
"id": "CVE-2018-16207"
},
{
"db": "CNNVD",
"id": "CNNVD-201903-1063"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "PowerAct Pro Master Agent for Windows Version 5.13 and earlier allows authenticated attackers to bypass access restriction to alter or edit unauthorized files via unspecified vectors. PowerAct Pro Master Agent for Windows provided by OMRON SOCIAL SOLUTIONS Co.,Ltd. fails to restrict access permissions. Hosono, Akane reported this vulnerability to IPA. JPCERT/CC coordinated with the developer under Information Security Early Warning Partnership.A user with an Windows general user acccount may alter or edit a file which the user does not have a permission to access",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-16207"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-000020"
},
{
"db": "VULHUB",
"id": "VHN-126543"
}
],
"trust": 1.71
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-16207",
"trust": 2.5
},
{
"db": "JVN",
"id": "JVN63981842",
"trust": 2.5
},
{
"db": "JVNDB",
"id": "JVNDB-2019-000020",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201903-1063",
"trust": 0.7
},
{
"db": "VULHUB",
"id": "VHN-126543",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-126543"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-000020"
},
{
"db": "NVD",
"id": "CVE-2018-16207"
},
{
"db": "CNNVD",
"id": "CNNVD-201903-1063"
}
]
},
"id": "VAR-201903-1172",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-126543"
}
],
"trust": 0.01
},
"last_update_date": "2023-12-18T12:28:25.987000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Download",
"trust": 0.8,
"url": "https://www.oss.omron.co.jp/ups/support/download/soft/poweractpro/master/poweractpro_master_windows.html"
},
{
"title": "Notification",
"trust": 0.8,
"url": "https://www.oss.omron.co.jp/ups/info/topics/190326.html"
},
{
"title": "Omron OMRON PowerAct Pro Master Agent for Windows Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=90481"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-000020"
},
{
"db": "CNNVD",
"id": "CNNVD-201903-1063"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "NVD-CWE-noinfo",
"trust": 1.0
},
{
"problemtype": "CWE-264",
"trust": 0.8
},
{
"problemtype": "CWE-284",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-126543"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-000020"
},
{
"db": "NVD",
"id": "CVE-2018-16207"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://jvn.jp/en/jp/jvn63981842/index.html"
},
{
"trust": 1.7,
"url": "https://www.oss.omron.co.jp/ups/info/topics/190326.html"
},
{
"trust": 1.7,
"url": "https://www.oss.omron.co.jp/ups/support/download/soft/poweractpro/master/poweractpro_master_windows.html"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-16207"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-16207"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-126543"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-000020"
},
{
"db": "NVD",
"id": "CVE-2018-16207"
},
{
"db": "CNNVD",
"id": "CNNVD-201903-1063"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-126543"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-000020"
},
{
"db": "NVD",
"id": "CVE-2018-16207"
},
{
"db": "CNNVD",
"id": "CNNVD-201903-1063"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-03-27T00:00:00",
"db": "VULHUB",
"id": "VHN-126543"
},
{
"date": "2019-03-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-000020"
},
{
"date": "2019-03-27T14:29:00.267000",
"db": "NVD",
"id": "CVE-2018-16207"
},
{
"date": "2019-03-27T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201903-1063"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-10-03T00:00:00",
"db": "VULHUB",
"id": "VHN-126543"
},
{
"date": "2019-09-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-000020"
},
{
"date": "2019-10-03T00:03:26.223000",
"db": "NVD",
"id": "CVE-2018-16207"
},
{
"date": "2019-10-23T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201903-1063"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201903-1063"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "PowerAct Pro Master Agent for Windows fails to restrict acess permissions",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-000020"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "access control error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201903-1063"
}
],
"trust": 0.6
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…