VAR-201904-1054
Vulnerability from variot - Updated: 2023-12-18 13:18Rockwell Automation PowerFlex 525 AC Drives 5.001 and earlier allow remote attackers to cause a denial of service by crashing the Common Industrial Protocol (CIP) network stack. The vulnerability allows the attacker to crash the CIP in a way that it does not accept new connections, but keeps the current connections active, which can prevent legitimate users from recovering control. Rockwell Automation PowerFlex 525 AC Drives Contains a resource exhaustion vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. The Rockwell Automation PowerFlex 525 is an adjustable AC drive from Rockwell Automation. A security vulnerability exists in Rockwell Automation PowerFlex 525 (with EtherNet/IP and Safety) version 5.001 and earlier. A remote attacker can exploit the vulnerability by continuously sending CIPs to cause a denial of service (resource exhaustion). PowerFlex 525 AC Drives with embedded EtherNet/IP and Safety 5.001 and prior are vulnerable
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201904-1054",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "powerflex 525 ac drives",
"scope": "lte",
"trust": 1.0,
"vendor": "rockwellautomation",
"version": "5.001"
},
{
"model": "powerflex 525 ac drives",
"scope": "lte",
"trust": 0.8,
"vendor": "rockwell automation",
"version": "5.001"
},
{
"model": "automation rockwell automation powerflex",
"scope": "eq",
"trust": 0.6,
"vendor": "rockwell",
"version": "525\u003c=5.001"
},
{
"model": "automation powerflex",
"scope": "eq",
"trust": 0.3,
"vendor": "rockwell",
"version": "5255.0.0.1"
},
{
"model": "automation powerflex",
"scope": "eq",
"trust": 0.3,
"vendor": "rockwell",
"version": "5254.0.0.1"
},
{
"model": "automation powerflex",
"scope": "eq",
"trust": 0.3,
"vendor": "rockwell",
"version": "5253.0.0.1"
},
{
"model": "automation powerflex",
"scope": "eq",
"trust": 0.3,
"vendor": "rockwell",
"version": "5252.0.0.3"
},
{
"model": "automation powerflex",
"scope": "eq",
"trust": 0.3,
"vendor": "rockwell",
"version": "5252.0.0.2"
},
{
"model": "automation powerflex",
"scope": "eq",
"trust": 0.3,
"vendor": "rockwell",
"version": "5251.0.0.5"
},
{
"model": "automation powerflex",
"scope": "eq",
"trust": 0.3,
"vendor": "rockwell",
"version": "5251.0.0.3"
},
{
"model": "automation powerflex",
"scope": "ne",
"trust": 0.3,
"vendor": "rockwell",
"version": "5255.0.0.2"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "powerflex 525 ac drives",
"version": "*"
}
],
"sources": [
{
"db": "IVD",
"id": "4763fe63-6b39-44d0-96bc-ad6e318f3144"
},
{
"db": "CNVD",
"id": "CNVD-2019-09280"
},
{
"db": "BID",
"id": "107633"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015223"
},
{
"db": "NVD",
"id": "CVE-2018-19282"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:rockwellautomation:powerflex_525_ac_drives_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "5.001",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:rockwellautomation:powerflex_525_ac_drives:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2018-19282"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Nicolas Merle ??,Nicolas Merle of Applied Risk,Nicolas Merle of Applied Risk reported this vulnerability to Rockwell Automation.",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201903-1164"
}
],
"trust": 0.6
},
"cve": "CVE-2018-19282",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Complete",
"baseScore": 10.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "CVE-2018-19282",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.9,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2019-09280",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "4763fe63-6b39-44d0-96bc-ad6e318f3144",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.2,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "VHN-129926",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2018-19282",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2018-19282",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2019-09280",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201903-1164",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "IVD",
"id": "4763fe63-6b39-44d0-96bc-ad6e318f3144",
"trust": 0.2,
"value": "CRITICAL"
},
{
"author": "VULHUB",
"id": "VHN-129926",
"trust": 0.1,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2018-19282",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "4763fe63-6b39-44d0-96bc-ad6e318f3144"
},
{
"db": "CNVD",
"id": "CNVD-2019-09280"
},
{
"db": "VULHUB",
"id": "VHN-129926"
},
{
"db": "VULMON",
"id": "CVE-2018-19282"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015223"
},
{
"db": "NVD",
"id": "CVE-2018-19282"
},
{
"db": "CNNVD",
"id": "CNNVD-201903-1164"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Rockwell Automation PowerFlex 525 AC Drives 5.001 and earlier allow remote attackers to cause a denial of service by crashing the Common Industrial Protocol (CIP) network stack. The vulnerability allows the attacker to crash the CIP in a way that it does not accept new connections, but keeps the current connections active, which can prevent legitimate users from recovering control. Rockwell Automation PowerFlex 525 AC Drives Contains a resource exhaustion vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. The Rockwell Automation PowerFlex 525 is an adjustable AC drive from Rockwell Automation. A security vulnerability exists in Rockwell Automation PowerFlex 525 (with EtherNet/IP and Safety) version 5.001 and earlier. A remote attacker can exploit the vulnerability by continuously sending CIPs to cause a denial of service (resource exhaustion). \nPowerFlex 525 AC Drives with embedded EtherNet/IP and Safety 5.001 and prior are vulnerable",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-19282"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015223"
},
{
"db": "CNVD",
"id": "CNVD-2019-09280"
},
{
"db": "BID",
"id": "107633"
},
{
"db": "IVD",
"id": "4763fe63-6b39-44d0-96bc-ad6e318f3144"
},
{
"db": "VULHUB",
"id": "VHN-129926"
},
{
"db": "VULMON",
"id": "CVE-2018-19282"
}
],
"trust": 2.79
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-19282",
"trust": 3.7
},
{
"db": "ICS CERT",
"id": "ICSA-19-087-01",
"trust": 3.5
},
{
"db": "BID",
"id": "107633",
"trust": 1.1
},
{
"db": "CNNVD",
"id": "CNNVD-201903-1164",
"trust": 0.9
},
{
"db": "CNVD",
"id": "CNVD-2019-09280",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015223",
"trust": 0.8
},
{
"db": "AUSCERT",
"id": "ESB-2019.1046",
"trust": 0.6
},
{
"db": "NSFOCUS",
"id": "43067",
"trust": 0.6
},
{
"db": "IVD",
"id": "4763FE63-6B39-44D0-96BC-AD6E318F3144",
"trust": 0.2
},
{
"db": "VULHUB",
"id": "VHN-129926",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2018-19282",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "4763fe63-6b39-44d0-96bc-ad6e318f3144"
},
{
"db": "CNVD",
"id": "CNVD-2019-09280"
},
{
"db": "VULHUB",
"id": "VHN-129926"
},
{
"db": "VULMON",
"id": "CVE-2018-19282"
},
{
"db": "BID",
"id": "107633"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015223"
},
{
"db": "NVD",
"id": "CVE-2018-19282"
},
{
"db": "CNNVD",
"id": "CNNVD-201903-1164"
}
]
},
"id": "VAR-201904-1054",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "4763fe63-6b39-44d0-96bc-ad6e318f3144"
},
{
"db": "CNVD",
"id": "CNVD-2019-09280"
},
{
"db": "VULHUB",
"id": "VHN-129926"
}
],
"trust": 1.9
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "4763fe63-6b39-44d0-96bc-ad6e318f3144"
},
{
"db": "CNVD",
"id": "CNVD-2019-09280"
}
]
},
"last_update_date": "2023-12-18T13:18:47.550000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "PowerFlex 525 AC Drives",
"trust": 0.8,
"url": "https://ab.rockwellautomation.com/drives/powerflex-525"
},
{
"title": "Patch for ARC and Rockwell Automation PowerFlex 525 Resource Consumption Vulnerabilities",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/158255"
},
{
"title": "Rockwell Automation PowerFlex 525 Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=90574"
},
{
"title": "Threatpost",
"trust": 0.1,
"url": "https://threatpost.com/critical-rockwell-automation-bug-in-drive-component-puts-iiot-plants-at-risk/143258/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-09280"
},
{
"db": "VULMON",
"id": "CVE-2018-19282"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015223"
},
{
"db": "CNNVD",
"id": "CNNVD-201903-1164"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-400",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-129926"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015223"
},
{
"db": "NVD",
"id": "CVE-2018-19282"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.6,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-19-087-01"
},
{
"trust": 1.8,
"url": "https://applied-risk.com/application/files/4215/5385/2294/advisory_ar2019004_rockwell_powerflex_525_denial_of_service.pdf"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-19282"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-19282"
},
{
"trust": 0.8,
"url": "https://applied-risk.com/application/files/4215/5385/2294/advisory_ar2019004_rockwell_powerflex_525_denial_of_service.pdf "
},
{
"trust": 0.7,
"url": "http://www.securityfocus.com/bid/107633"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/78046"
},
{
"trust": 0.6,
"url": "http://www.nsfocus.net/vulndb/43067"
},
{
"trust": 0.3,
"url": "https://ab.rockwellautomation.com/drives/powerflex-525#overview"
},
{
"trust": 0.3,
"url": "https://www.rockwellautomation.com/en_in/overview.page"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/400.html"
},
{
"trust": 0.1,
"url": "https://threatpost.com/critical-rockwell-automation-bug-in-drive-component-puts-iiot-plants-at-risk/143258/"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-09280"
},
{
"db": "VULHUB",
"id": "VHN-129926"
},
{
"db": "VULMON",
"id": "CVE-2018-19282"
},
{
"db": "BID",
"id": "107633"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015223"
},
{
"db": "NVD",
"id": "CVE-2018-19282"
},
{
"db": "CNNVD",
"id": "CNNVD-201903-1164"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "4763fe63-6b39-44d0-96bc-ad6e318f3144"
},
{
"db": "CNVD",
"id": "CNVD-2019-09280"
},
{
"db": "VULHUB",
"id": "VHN-129926"
},
{
"db": "VULMON",
"id": "CVE-2018-19282"
},
{
"db": "BID",
"id": "107633"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015223"
},
{
"db": "NVD",
"id": "CVE-2018-19282"
},
{
"db": "CNNVD",
"id": "CNNVD-201903-1164"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-04-07T00:00:00",
"db": "IVD",
"id": "4763fe63-6b39-44d0-96bc-ad6e318f3144"
},
{
"date": "2019-04-01T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-09280"
},
{
"date": "2019-04-04T00:00:00",
"db": "VULHUB",
"id": "VHN-129926"
},
{
"date": "2019-04-04T00:00:00",
"db": "VULMON",
"id": "CVE-2018-19282"
},
{
"date": "2019-03-28T00:00:00",
"db": "BID",
"id": "107633"
},
{
"date": "2019-05-14T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-015223"
},
{
"date": "2019-04-04T21:29:00.660000",
"db": "NVD",
"id": "CVE-2018-19282"
},
{
"date": "2019-03-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201903-1164"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-04-07T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-09280"
},
{
"date": "2019-04-09T00:00:00",
"db": "VULHUB",
"id": "VHN-129926"
},
{
"date": "2019-04-09T00:00:00",
"db": "VULMON",
"id": "CVE-2018-19282"
},
{
"date": "2019-03-28T00:00:00",
"db": "BID",
"id": "107633"
},
{
"date": "2019-05-14T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-015223"
},
{
"date": "2019-04-09T14:35:02.620000",
"db": "NVD",
"id": "CVE-2018-19282"
},
{
"date": "2019-04-19T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201903-1164"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201903-1164"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Rockwell Automation PowerFlex 525 AC Drives Vulnerable to resource exhaustion",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-015223"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Resource management error",
"sources": [
{
"db": "IVD",
"id": "4763fe63-6b39-44d0-96bc-ad6e318f3144"
},
{
"db": "CNNVD",
"id": "CNNVD-201903-1164"
}
],
"trust": 0.8
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.