VAR-201905-1144
Vulnerability from variot - Updated: 2023-12-18 14:05An issue was discovered in Quest KACE Systems Management Appliance before 9.1. The script at /service/kbot_service_notsoap.php is vulnerable to unauthenticated reflected XSS when user-supplied input to the METHOD GET parameter is processed by the web application. Since the application does not properly validate and sanitize this parameter, it is possible to place arbitrary script code into the context of the same page. QuestSoftwareKACESystemsManagementAppliance is a system management device from QuestSoftware, USA. The product supports IT asset management, server management and monitoring, software license management and patch management. A cross-site scripting vulnerability exists in QuestSoftwareKACESystemsManagementAppliance 9.0 and earlier that could allow an attacker to execute client-side code
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201905-1144",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "kace systems management appliance",
"scope": "lt",
"trust": 1.8,
"vendor": "quest",
"version": "9.1"
},
{
"model": "software kace systems management appliance",
"scope": "lte",
"trust": 0.6,
"vendor": "quest",
"version": "\u003c=9.0"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-25506"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004947"
},
{
"db": "NVD",
"id": "CVE-2019-11604"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:quest:kace_systems_management_appliance:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "9.1",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2019-11604"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Julien Ahrens",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201905-976"
}
],
"trust": 0.6
},
"cve": "CVE-2019-11604",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": true,
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Medium",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 4.3,
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2019-11604",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.6,
"id": "CNVD-2019-25506",
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"exploitabilityScore": 2.8,
"impactScore": 2.7,
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 6.1,
"baseSeverity": "Medium",
"confidentialityImpact": "Low",
"exploitabilityScore": null,
"id": "CVE-2019-11604",
"impactScore": null,
"integrityImpact": "Low",
"privilegesRequired": "None",
"scope": "Changed",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2019-11604",
"trust": 1.8,
"value": "MEDIUM"
},
{
"author": "CNVD",
"id": "CNVD-2019-25506",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201905-976",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-25506"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004947"
},
{
"db": "NVD",
"id": "CVE-2019-11604"
},
{
"db": "CNNVD",
"id": "CNNVD-201905-976"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "An issue was discovered in Quest KACE Systems Management Appliance before 9.1. The script at /service/kbot_service_notsoap.php is vulnerable to unauthenticated reflected XSS when user-supplied input to the METHOD GET parameter is processed by the web application. Since the application does not properly validate and sanitize this parameter, it is possible to place arbitrary script code into the context of the same page. QuestSoftwareKACESystemsManagementAppliance is a system management device from QuestSoftware, USA. The product supports IT asset management, server management and monitoring, software license management and patch management. A cross-site scripting vulnerability exists in QuestSoftwareKACESystemsManagementAppliance 9.0 and earlier that could allow an attacker to execute client-side code",
"sources": [
{
"db": "NVD",
"id": "CVE-2019-11604"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004947"
},
{
"db": "CNVD",
"id": "CNVD-2019-25506"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2019-11604",
"trust": 3.0
},
{
"db": "PACKETSTORM",
"id": "153053",
"trust": 3.0
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004947",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2019-25506",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-201905-976",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-25506"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004947"
},
{
"db": "NVD",
"id": "CVE-2019-11604"
},
{
"db": "CNNVD",
"id": "CNNVD-201905-976"
}
]
},
"id": "VAR-201905-1144",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-25506"
}
],
"trust": 1.225
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-25506"
}
]
},
"last_update_date": "2023-12-18T14:05:09.135000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "KACE Systems Management Appliance",
"trust": 0.8,
"url": "https://www.quest.com/jp-ja/products/kace-systems-management-appliance/"
},
{
"title": "Patch for QuestSoftwareKACESystemsManagementAppliance Cross-Site Scripting Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/172815"
},
{
"title": "Quest Software KACE Systems Management Appliance Fixes for cross-site scripting vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=92928"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-25506"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004947"
},
{
"db": "CNNVD",
"id": "CNNVD-201905-976"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-79",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-004947"
},
{
"db": "NVD",
"id": "CVE-2019-11604"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.6,
"url": "http://packetstormsecurity.com/files/153053/quest-kace-systems-management-appliance-9.0-cross-site-scripting.html"
},
{
"trust": 2.2,
"url": "http://seclists.org/fulldisclosure/2019/may/40"
},
{
"trust": 2.2,
"url": "https://www.rcesecurity.com/"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2019-11604"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-11604"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-25506"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004947"
},
{
"db": "NVD",
"id": "CVE-2019-11604"
},
{
"db": "CNNVD",
"id": "CNNVD-201905-976"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2019-25506"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-004947"
},
{
"db": "NVD",
"id": "CVE-2019-11604"
},
{
"db": "CNNVD",
"id": "CNNVD-201905-976"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-08-02T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-25506"
},
{
"date": "2019-06-12T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-004947"
},
{
"date": "2019-05-24T17:29:02.633000",
"db": "NVD",
"id": "CVE-2019-11604"
},
{
"date": "2019-05-23T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201905-976"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-08-02T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-25506"
},
{
"date": "2019-06-12T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-004947"
},
{
"date": "2019-05-29T23:54:03.683000",
"db": "NVD",
"id": "CVE-2019-11604"
},
{
"date": "2019-05-30T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201905-976"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201905-976"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Quest Software KACE Systems Management Appliance Cross-Site Scripting Vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-25506"
},
{
"db": "CNNVD",
"id": "CNNVD-201905-976"
}
],
"trust": 1.2
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "XSS",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201905-976"
}
],
"trust": 0.6
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.