Vulnerability from variot - Updated: 2023-12-18 12:36TRENDnet TEW-827DRU with firmware up to and including 2.04B03 contains a stack-based buffer overflow while returning an error message to the user about failure to resolve a hostname during a ping or traceroute attempt. This allows an authenticated user to execute arbitrary code. The exploit can be exercised on the local intranet or remotely if remote administration is enabled. TRENDnet TEW-827DRU Contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. TRENDnet TEW-827DRU is a wireless router produced by TRENDnet. A buffer error vulnerability exists in TRENDnet TEW-827DRU with firmware version 2.04B03 and earlier. This vulnerability stems from the incorrect verification of data boundaries when the network system or product performs operations on the memory, resulting in incorrect read and write operations to other associated memory locations. Attackers can exploit this vulnerability to cause buffer overflow or heap overflow, etc
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201907-0435",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "tew-827dru",
"scope": "lte",
"trust": 1.8,
"vendor": "trendnet",
"version": "2.04b03"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-006246"
},
{
"db": "NVD",
"id": "CVE-2019-13280"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:trendnet:tew-827dru_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "2.04b03",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:trendnet:tew-827dru:2.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2019-13280"
}
]
},
"cve": "CVE-2019-13280",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 6.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 6.5,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2019-13280",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 6.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"id": "VHN-145111",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:S/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2019-13280",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2019-13280",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201907-513",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-145111",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-145111"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-006246"
},
{
"db": "NVD",
"id": "CVE-2019-13280"
},
{
"db": "CNNVD",
"id": "CNNVD-201907-513"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "TRENDnet TEW-827DRU with firmware up to and including 2.04B03 contains a stack-based buffer overflow while returning an error message to the user about failure to resolve a hostname during a ping or traceroute attempt. This allows an authenticated user to execute arbitrary code. The exploit can be exercised on the local intranet or remotely if remote administration is enabled. TRENDnet TEW-827DRU Contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. TRENDnet TEW-827DRU is a wireless router produced by TRENDnet. A buffer error vulnerability exists in TRENDnet TEW-827DRU with firmware version 2.04B03 and earlier. This vulnerability stems from the incorrect verification of data boundaries when the network system or product performs operations on the memory, resulting in incorrect read and write operations to other associated memory locations. Attackers can exploit this vulnerability to cause buffer overflow or heap overflow, etc",
"sources": [
{
"db": "NVD",
"id": "CVE-2019-13280"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-006246"
},
{
"db": "VULHUB",
"id": "VHN-145111"
}
],
"trust": 1.71
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2019-13280",
"trust": 2.5
},
{
"db": "JVNDB",
"id": "JVNDB-2019-006246",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201907-513",
"trust": 0.7
},
{
"db": "VULHUB",
"id": "VHN-145111",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-145111"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-006246"
},
{
"db": "NVD",
"id": "CVE-2019-13280"
},
{
"db": "CNNVD",
"id": "CNNVD-201907-513"
}
]
},
"id": "VAR-201907-0435",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-145111"
}
],
"trust": 0.6736842
},
"last_update_date": "2023-12-18T12:36:08Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "https://www.trendnet.com/home"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-006246"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.1
},
{
"problemtype": "CWE-119",
"trust": 0.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-145111"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-006246"
},
{
"db": "NVD",
"id": "CVE-2019-13280"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://github.com/fuzzywalls/trendnetexploits/tree/master/cve-2019-13280"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2019-13280"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-13280"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-145111"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-006246"
},
{
"db": "NVD",
"id": "CVE-2019-13280"
},
{
"db": "CNNVD",
"id": "CNNVD-201907-513"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-145111"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-006246"
},
{
"db": "NVD",
"id": "CVE-2019-13280"
},
{
"db": "CNNVD",
"id": "CNNVD-201907-513"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-07-09T00:00:00",
"db": "VULHUB",
"id": "VHN-145111"
},
{
"date": "2019-07-17T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-006246"
},
{
"date": "2019-07-09T19:15:12.437000",
"db": "NVD",
"id": "CVE-2019-13280"
},
{
"date": "2019-07-09T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201907-513"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-08-24T00:00:00",
"db": "VULHUB",
"id": "VHN-145111"
},
{
"date": "2019-07-17T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-006246"
},
{
"date": "2020-08-24T17:37:01.140000",
"db": "NVD",
"id": "CVE-2019-13280"
},
{
"date": "2020-08-25T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201907-513"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201907-513"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "TRENDnet TEW-827DRU Buffer error vulnerability in some firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-006246"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201907-513"
}
],
"trust": 0.6
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.