VAR-201907-1137
Vulnerability from variot - Updated: 2024-05-17 22:51Vivotek FD8136 devices allow Remote Command Injection, aka "another command injection vulnerability in our target device," a different issue than CVE-2018-14494. NOTE: The vendor has disputed this as a vulnerability and states that the issue does not cause a web server crash or have any other affect on it's performance. This vulnerability CVE-2018-14494 Is a different vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. VivotekFD8136 is a hemispherical network camera from China's Taiwan Vivotek. This vulnerability is caused by external input data constructing executable commands. The network system or product does not properly filter the special elements. Attackers can use this vulnerability to execute illegal commands
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201907-1137",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "fd8136",
"scope": "eq",
"trust": 1.0,
"vendor": "vivotek",
"version": "0301a"
},
{
"model": "network camera fd8136",
"scope": null,
"trust": 0.8,
"vendor": "vivotek",
"version": null
},
{
"model": "fd8136",
"scope": null,
"trust": 0.6,
"vendor": "vivotek",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-22270"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015835"
},
{
"db": "NVD",
"id": "CVE-2018-14495"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:vivotek:fd8136_firmware:0301a:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:vivotek:fd8136:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2018-14495"
}
]
},
"cve": "CVE-2018-14495",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Complete",
"baseScore": 10.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "CVE-2018-14495",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.9,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2019-22270",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "VHN-124660",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2018-14495",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2018-14495",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2019-22270",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201907-553",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULHUB",
"id": "VHN-124660",
"trust": 0.1,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2018-14495",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-22270"
},
{
"db": "VULHUB",
"id": "VHN-124660"
},
{
"db": "VULMON",
"id": "CVE-2018-14495"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015835"
},
{
"db": "CNNVD",
"id": "CNNVD-201907-553"
},
{
"db": "NVD",
"id": "CVE-2018-14495"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Vivotek FD8136 devices allow Remote Command Injection, aka \"another command injection vulnerability in our target device,\" a different issue than CVE-2018-14494. NOTE: The vendor has disputed this as a vulnerability and states that the issue does not cause a web server crash or have any other affect on it\u0027s performance. This vulnerability CVE-2018-14494 Is a different vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. VivotekFD8136 is a hemispherical network camera from China\u0027s Taiwan Vivotek. This vulnerability is caused by external input data constructing executable commands. The network system or product does not properly filter the special elements. Attackers can use this vulnerability to execute illegal commands",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-14495"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015835"
},
{
"db": "CNVD",
"id": "CNVD-2019-22270"
},
{
"db": "VULHUB",
"id": "VHN-124660"
},
{
"db": "VULMON",
"id": "CVE-2018-14495"
}
],
"trust": 2.34
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-14495",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015835",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201907-553",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2019-22270",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-124660",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2018-14495",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-22270"
},
{
"db": "VULHUB",
"id": "VHN-124660"
},
{
"db": "VULMON",
"id": "CVE-2018-14495"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015835"
},
{
"db": "CNNVD",
"id": "CNNVD-201907-553"
},
{
"db": "NVD",
"id": "CVE-2018-14495"
}
]
},
"id": "VAR-201907-1137",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-22270"
},
{
"db": "VULHUB",
"id": "VHN-124660"
}
],
"trust": 1.45
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-22270"
}
]
},
"last_update_date": "2024-05-17T22:51:07.153000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "FD8136",
"trust": 0.8,
"url": "https://www.vivotek.com/fd8136"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-015835"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-78",
"trust": 1.1
},
{
"problemtype": "CWE-77",
"trust": 0.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-124660"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015835"
},
{
"db": "NVD",
"id": "CVE-2018-14495"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.2,
"url": "https://www.vdalabs.com/2018/07/23/professional-iot-hacking-series-target-selection-firmware-analysis/"
},
{
"trust": 2.4,
"url": "https://www.vdalabs.com/2018/08/06/professional-iot-hacking-series-hunting-remote-command-injection/"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-14495"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-14495"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/78.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-22270"
},
{
"db": "VULHUB",
"id": "VHN-124660"
},
{
"db": "VULMON",
"id": "CVE-2018-14495"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015835"
},
{
"db": "CNNVD",
"id": "CNNVD-201907-553"
},
{
"db": "NVD",
"id": "CVE-2018-14495"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2019-22270"
},
{
"db": "VULHUB",
"id": "VHN-124660"
},
{
"db": "VULMON",
"id": "CVE-2018-14495"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-015835"
},
{
"db": "CNNVD",
"id": "CNNVD-201907-553"
},
{
"db": "NVD",
"id": "CVE-2018-14495"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-07-12T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-22270"
},
{
"date": "2019-07-10T00:00:00",
"db": "VULHUB",
"id": "VHN-124660"
},
{
"date": "2019-07-10T00:00:00",
"db": "VULMON",
"id": "CVE-2018-14495"
},
{
"date": "2019-07-12T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-015835"
},
{
"date": "2019-07-10T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201907-553"
},
{
"date": "2019-07-10T14:15:10.637000",
"db": "NVD",
"id": "CVE-2018-14495"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-07-12T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-22270"
},
{
"date": "2020-08-24T00:00:00",
"db": "VULHUB",
"id": "VHN-124660"
},
{
"date": "2020-08-24T00:00:00",
"db": "VULMON",
"id": "CVE-2018-14495"
},
{
"date": "2019-07-12T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-015835"
},
{
"date": "2020-10-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201907-553"
},
{
"date": "2024-05-17T01:23:56.370000",
"db": "NVD",
"id": "CVE-2018-14495"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201907-553"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Vivotek FD8136 Command injection vulnerability in devices",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-015835"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "operating system commend injection",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201907-553"
}
],
"trust": 0.6
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.