VAR-202002-0719
Vulnerability from variot - Updated: 2023-12-18 13:37A vulnerability in the High Availability (HA) service of Cisco Smart Software Manager On-Prem could allow an unauthenticated, remote attacker to access a sensitive part of the system with a high-privileged account. The vulnerability is due to a system account that has a default and static password and is not under the control of the system administrator. An attacker could exploit this vulnerability by using this default account to connect to the affected system. A successful exploit could allow the attacker to obtain read and write access to system data, including the configuration of an affected device. The attacker would gain access to a sensitive portion of the system, but the attacker would not have full administrative rights to control the device
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202002-0719",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "smart software manager on-prem",
"scope": "lt",
"trust": 1.0,
"vendor": "cisco",
"version": "7-202001"
},
{
"model": "smart software manager on-prem",
"scope": null,
"trust": 0.8,
"vendor": "cisco",
"version": null
},
{
"model": "smart software manager on-prem",
"scope": "eq",
"trust": 0.6,
"vendor": "cisco",
"version": null
},
{
"model": "smart software manager on-prem",
"scope": "eq",
"trust": 0.6,
"vendor": "cisco",
"version": "7-201910"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-002271"
},
{
"db": "NVD",
"id": "CVE-2020-3158"
},
{
"db": "CNNVD",
"id": "CNNVD-202002-985"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:cisco:smart_software_manager_on-prem:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "7-202001",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-3158"
}
]
},
"cve": "CVE-2020-3158",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 8.8,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.6,
"impactScore": 9.2,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Medium",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 8.8,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "JVNDB-2020-002271",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:N",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "NONE",
"baseScore": 8.8,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.6,
"id": "VHN-181283",
"impactScore": 9.2,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:M/AU:N/C:C/I:C/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.2,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "ykramarz@cisco.com",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 9.1,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2020-002271",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2020-3158",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "ykramarz@cisco.com",
"id": "CVE-2020-3158",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "JVNDB-2020-002271",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNNVD",
"id": "CNNVD-202002-985",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULHUB",
"id": "VHN-181283",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-181283"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-002271"
},
{
"db": "NVD",
"id": "CVE-2020-3158"
},
{
"db": "NVD",
"id": "CVE-2020-3158"
},
{
"db": "CNNVD",
"id": "CNNVD-202002-985"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability in the High Availability (HA) service of Cisco Smart Software Manager On-Prem could allow an unauthenticated, remote attacker to access a sensitive part of the system with a high-privileged account. The vulnerability is due to a system account that has a default and static password and is not under the control of the system administrator. An attacker could exploit this vulnerability by using this default account to connect to the affected system. A successful exploit could allow the attacker to obtain read and write access to system data, including the configuration of an affected device. The attacker would gain access to a sensitive portion of the system, but the attacker would not have full administrative rights to control the device",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-3158"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-002271"
},
{
"db": "VULHUB",
"id": "VHN-181283"
}
],
"trust": 1.71
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2020-3158",
"trust": 2.5
},
{
"db": "JVNDB",
"id": "JVNDB-2020-002271",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202002-985",
"trust": 0.7
},
{
"db": "AUSCERT",
"id": "ESB-2020.0605",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-181283",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-181283"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-002271"
},
{
"db": "NVD",
"id": "CVE-2020-3158"
},
{
"db": "CNNVD",
"id": "CNNVD-202002-985"
}
]
},
"id": "VAR-202002-0719",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-181283"
}
],
"trust": 0.01
},
"last_update_date": "2023-12-18T13:37:57.095000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "cisco-sa-on-prem-static-cred-sL8rDs8",
"trust": 0.8,
"url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-on-prem-static-cred-sl8rds8"
},
{
"title": "Cisco Smart Software Manager On-Prem Repair measures for trust management problem vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=110548"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-002271"
},
{
"db": "CNNVD",
"id": "CNNVD-202002-985"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-798",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-181283"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-002271"
},
{
"db": "NVD",
"id": "CVE-2020-3158"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-on-prem-static-cred-sl8rds8"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-3158"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-3158"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2020.0605/"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-181283"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-002271"
},
{
"db": "NVD",
"id": "CVE-2020-3158"
},
{
"db": "CNNVD",
"id": "CNNVD-202002-985"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-181283"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-002271"
},
{
"db": "NVD",
"id": "CVE-2020-3158"
},
{
"db": "CNNVD",
"id": "CNNVD-202002-985"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-02-19T00:00:00",
"db": "VULHUB",
"id": "VHN-181283"
},
{
"date": "2020-03-10T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-002271"
},
{
"date": "2020-02-19T20:15:15.393000",
"db": "NVD",
"id": "CVE-2020-3158"
},
{
"date": "2020-02-19T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202002-985"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-02-28T00:00:00",
"db": "VULHUB",
"id": "VHN-181283"
},
{
"date": "2020-03-10T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-002271"
},
{
"date": "2020-02-28T00:47:58.737000",
"db": "NVD",
"id": "CVE-2020-3158"
},
{
"date": "2020-02-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202002-985"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202002-985"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Cisco Smart Software Manager On-Prem Vulnerability in using hard-coded credentials in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-002271"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "trust management problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202002-985"
}
],
"trust": 0.6
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.