var-202004-1459
Vulnerability from variot
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects R7800 before 1.0.2.40 and R9000 before 1.0.2.52. NETGEAR R7800 and R9000 The device is vulnerable to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR R9000 and NETGEAR R7800 are both wireless routers of NETGEAR.
NETGEAR R7800 versions prior to 1.0.2.40 and R9000 versions prior to 1.0.2.52 have buffer overflow vulnerabilities, which can be exploited by attackers to cause buffer overflows or heap overflows. This affects R7800 prior to 1.0.2.40 and R9000 prior to 1.0.2.52
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202004-1459", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "r7800", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.2.40" }, { "model": "r9000", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.2.52" }, { "model": "r7800", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.2.40" }, { "model": "r9000", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.2.52" }, { "model": "r7800", "scope": "eq", "trust": 0.1, "vendor": "netgear", "version": "1.0.2.16" }, { "model": "r7800", "scope": "eq", "trust": 0.1, "vendor": "netgear", "version": "1.0.2.28" }, { "model": "r7800", "scope": "eq", "trust": 0.1, "vendor": "netgear", "version": "1.0.2.30" }, { "model": "r7800", "scope": "eq", "trust": 0.1, "vendor": "netgear", "version": "1.0.2.32" }, { "model": "r7800", "scope": "eq", "trust": 0.1, "vendor": "netgear", "version": "1.0.2.36" }, { "model": "r7800", "scope": "eq", "trust": 0.1, "vendor": "netgear", "version": "1.0.2.38" }, { "model": "r9000", "scope": "eq", "trust": 0.1, "vendor": "netgear", "version": null }, { "model": "r9000", "scope": "eq", "trust": 0.1, "vendor": "netgear", "version": "1.0.2.4" }, { "model": "r9000", "scope": "eq", "trust": 0.1, "vendor": "netgear", "version": "1.0.2.30" }, { "model": "r9000", "scope": "eq", "trust": 0.1, "vendor": "netgear", "version": "1.0.2.40" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-25860" }, { "db": "VULMON", "id": "CVE-2017-18699" }, { "db": "JVNDB", "id": "JVNDB-2017-014966" }, { "db": "NVD", "id": "CVE-2017-18699" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.40", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.52", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2017-18699" } ] }, "cve": "CVE-2017-18699", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2017-014966", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "id": "CNVD-2020-25860", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "VULMON", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "id": "CVE-2017-18699", "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "MEDIUM", "trust": 0.1, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2017-014966", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2017-18699", "trust": 1.0, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2017-18699", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "JVNDB-2017-014966", "trust": 0.8, "value": "Medium" }, { "author": "CNVD", "id": "CNVD-2020-25860", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202004-2119", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2017-18699", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-25860" }, { "db": "VULMON", "id": "CVE-2017-18699" }, { "db": "JVNDB", "id": "JVNDB-2017-014966" }, { "db": "NVD", "id": "CVE-2017-18699" }, { "db": "NVD", "id": "CVE-2017-18699" }, { "db": "CNNVD", "id": "CNNVD-202004-2119" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects R7800 before 1.0.2.40 and R9000 before 1.0.2.52. NETGEAR R7800 and R9000 The device is vulnerable to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR R9000 and NETGEAR R7800 are both wireless routers of NETGEAR. \n\r\n\r\nNETGEAR R7800 versions prior to 1.0.2.40 and R9000 versions prior to 1.0.2.52 have buffer overflow vulnerabilities, which can be exploited by attackers to cause buffer overflows or heap overflows. This affects R7800 prior to 1.0.2.40 and R9000 prior to 1.0.2.52", "sources": [ { "db": "NVD", "id": "CVE-2017-18699" }, { "db": "JVNDB", "id": "JVNDB-2017-014966" }, { "db": "CNVD", "id": "CNVD-2020-25860" }, { "db": "VULMON", "id": "CVE-2017-18699" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2017-18699", "trust": 3.1 }, { "db": "JVNDB", "id": "JVNDB-2017-014966", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2020-25860", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202004-2119", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2017-18699", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-25860" }, { "db": "VULMON", "id": "CVE-2017-18699" }, { "db": "JVNDB", "id": "JVNDB-2017-014966" }, { "db": "NVD", "id": "CVE-2017-18699" }, { "db": "CNNVD", "id": "CNNVD-202004-2119" } ] }, "id": "VAR-202004-1459", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2020-25860" } ], "trust": 1.0224239549999998 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-25860" } ] }, "last_update_date": "2023-12-18T13:33:04.664000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Post-Authentication Stack Overflow on Some Routers, PSV-2017-2595", "trust": 0.8, "url": "https://kb.netgear.com/000053203/security-advisory-for-post-authentication-stack-overflow-on-some-routers-psv-2017-2595" }, { "title": "Patch for NETGEAR R7800 and R9000 buffer overflow vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/216005" }, { "title": "NETGEAR R7800 and R9000 Buffer error vulnerability fix", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=117042" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-25860" }, { "db": "JVNDB", "id": "JVNDB-2017-014966" }, { "db": "CNNVD", "id": "CNNVD-202004-2119" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2017-014966" }, { "db": "NVD", "id": "CVE-2017-18699" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2017-18699" }, { "trust": 1.7, "url": "https://kb.netgear.com/000053203/security-advisory-for-post-authentication-stack-overflow-on-some-routers-psv-2017-2595" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-18699" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/787.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-25860" }, { "db": "VULMON", "id": "CVE-2017-18699" }, { "db": "JVNDB", "id": "JVNDB-2017-014966" }, { "db": "NVD", "id": "CVE-2017-18699" }, { "db": "CNNVD", "id": "CNNVD-202004-2119" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2020-25860" }, { "db": "VULMON", "id": "CVE-2017-18699" }, { "db": "JVNDB", "id": "JVNDB-2017-014966" }, { "db": "NVD", "id": "CVE-2017-18699" }, { "db": "CNNVD", "id": "CNNVD-202004-2119" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-04-30T00:00:00", "db": "CNVD", "id": "CNVD-2020-25860" }, { "date": "2020-04-24T00:00:00", "db": "VULMON", "id": "CVE-2017-18699" }, { "date": "2020-05-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2017-014966" }, { "date": "2020-04-24T15:15:12.287000", "db": "NVD", "id": "CVE-2017-18699" }, { "date": "2020-04-24T00:00:00", "db": "CNNVD", "id": "CNNVD-202004-2119" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-04-30T00:00:00", "db": "CNVD", "id": "CNVD-2020-25860" }, { "date": "2020-04-28T00:00:00", "db": "VULMON", "id": "CVE-2017-18699" }, { "date": "2020-05-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2017-014966" }, { "date": "2020-04-28T11:55:26.447000", "db": "NVD", "id": "CVE-2017-18699" }, { "date": "2020-04-29T00:00:00", "db": "CNNVD", "id": "CNNVD-202004-2119" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202004-2119" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "NETGEAR R7800 and R9000 Out-of-bounds write vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2017-014966" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202004-2119" } ], "trust": 0.6 } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.