var-202006-0317
Vulnerability from variot
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. An exposed API call allows users to provide files to be processed without sanitation. This may allow an attacker to specify a filename to execute unauthorized code and modify files or data. Rockwell Automation Provided by the company FactoryTalk Linx Software The following multiple vulnerabilities exist in. * Improper input confirmation (CWE-20) - CVE-2020-11999 * Improper input confirmation (CWE-20) - CVE-2020-12001 * Directory traversal (CWE-22) - CVE-2020-12003 * Upload any file (CWE-434) - CVE-2020-12005The expected impact depends on each vulnerability, but it may be affected as follows. * API Arbitrary code may be executed or files or data may be tampered with by a remote third party because arbitrary files are not properly sanitized during a call. - CVE-2020-11999 * Proper sanitization of specially crafted files can lead to sensitive information being stolen or arbitrary code being executed by a remote third party. - CVE-2020-12001 * API Sensitive information on the local hard drive is stolen by a remote third party because it does not properly sanitize the specially crafted request during the call. - CVE-2020-12003 * Improperly compressed by a remote third party EDF By uploading the file, the compressed file can be decompressed. CPU All resources are consumed and service operation is interrupted (DoS) The condition is triggered - CVE-2020-12005. Rockwell Automation RSLinx Classic and others are products of Rockwell Automation (USA). Rockwell Automation RSLinx Classic is a set of industrial communication solutions. Rockwell Automation ControlFLASH is a firmware update utility
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202006-0317", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "factorytalk linx", "scope": "eq", "trust": 1.0, "vendor": "rockwellautomation", "version": "6.10" }, { "model": "factorytalk linx", "scope": "eq", "trust": 1.0, "vendor": "rockwellautomation", "version": "6.11" }, { "model": "factorytalk linx", "scope": "eq", "trust": 1.0, "vendor": "rockwellautomation", "version": "6.00" }, { "model": "rslinx classic", "scope": "lte", "trust": 1.0, "vendor": "rockwellautomation", "version": "4.11.00" }, { "model": "connected components workbench", "scope": "eq", "trust": 0.8, "vendor": "rockwell automation", "version": "version 12" }, { "model": "controlflash", "scope": "eq", "trust": 0.8, "vendor": "rockwell automation", "version": "version 14 \u304a\u3088\u3073\u305d\u308c" }, { "model": "controlflash plus", "scope": "eq", "trust": 0.8, "vendor": "rockwell automation", "version": "version 1 \u304a\u3088\u3073\u305d\u308c" }, { "model": "factorytalk asset centre", "scope": "eq", "trust": 0.8, "vendor": "rockwell automation", "version": "version 9 \u304a\u3088\u3073\u305d\u308c" }, { "model": "factorytalk linx", "scope": "eq", "trust": 0.8, "vendor": "rockwell automation", "version": "version 6.00, 6.10, 6.11" }, { "model": "factorytalk linx commdtm", "scope": "eq", "trust": 0.8, "vendor": "rockwell automation", "version": "version 1 \u304a\u3088\u3073\u305d\u308c" }, { "model": "studio 5000 launcher", "scope": "eq", "trust": 0.8, "vendor": "rockwell automation", "version": "version 31 \u304a\u3088\u3073\u305d\u308c" }, { "model": "studio 5000 logix designer", "scope": "eq", "trust": 0.8, "vendor": "rockwell automation", "version": "software version 32" }, { "model": "automation rslinx classic", "scope": "lte", "trust": 0.6, "vendor": "rockwell", "version": "\u003c=4.11.00" }, { "model": "automation factorytalk linx", "scope": "eq", "trust": 0.6, "vendor": "rockwell", "version": "6.00" }, { "model": "automation factorytalk linx", "scope": "eq", "trust": 0.6, "vendor": "rockwell", "version": "6.10" }, { "model": "automation factorytalk linx", "scope": "eq", "trust": 0.6, "vendor": "rockwell", "version": "6.11" }, { "model": "automation connected components workbench", "scope": "lte", "trust": 0.6, "vendor": "rockwell", "version": "\u003c=12" }, { "model": "automation controlflash", "scope": "lte", "trust": 0.6, "vendor": "rockwell", "version": "\u003c=14" }, { "model": "automation controlflash plus", "scope": "lte", "trust": 0.6, "vendor": "rockwell", "version": "\u003c=1" }, { "model": "automation factorytalk asset centre", "scope": "lte", "trust": 0.6, "vendor": "rockwell", "version": "\u003c=9" }, { "model": "automation factorytalk linx commdtm", "scope": "lte", "trust": 0.6, "vendor": "rockwell", "version": "\u003c=1" }, { "model": "automation studio launcher", "scope": "eq", "trust": 0.6, "vendor": "rockwell", "version": "5000\u003c=31" }, { "model": "automation studio logix designer software", "scope": "eq", "trust": 0.6, "vendor": "rockwell", "version": "5000\u003c=32" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-38696" }, { "db": "JVNDB", "id": "JVNDB-2020-005434" }, { "db": "NVD", "id": "CVE-2020-11999" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.00:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.10:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:rockwellautomation:factorytalk_linx:6.11:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:rockwellautomation:rslinx_classic:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "4.11.00", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-11999" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Sharon Brizinov and Amir Preminger (VP Research) of Claroty", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-918" } ], "trust": 0.6 }, "cve": "CVE-2020-11999", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 5.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.0, "impactScore": 4.9, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 5.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.0, "id": "CNVD-2020-38696", "impactScore": 4.9, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "VULHUB", "availabilityImpact": "NONE", "baseScore": 5.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.0, "id": "VHN-164633", "impactScore": 4.9, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:S/C:P/I:P/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.2, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA score", "availabilityImpact": "None", "baseScore": 9.6, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-005434", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "Low", "scope": "Changed", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA score", "availabilityImpact": "None", "baseScore": 9.6, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-005434", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "Low", "scope": "Changed", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA score", "availabilityImpact": "None", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-005434", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA score", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2020-005434", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "IPA", "id": "JVNDB-2020-005434", "trust": 1.6, "value": "Critical" }, { "author": "IPA", "id": "JVNDB-2020-005434", "trust": 1.6, "value": "High" }, { "author": "NVD", "id": "CVE-2020-11999", "trust": 1.0, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2020-38696", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202006-918", "trust": 0.6, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-164633", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-38696" }, { "db": "VULHUB", "id": "VHN-164633" }, { "db": "JVNDB", "id": "JVNDB-2020-005434" }, { "db": "JVNDB", "id": "JVNDB-2020-005434" }, { "db": "JVNDB", "id": "JVNDB-2020-005434" }, { "db": "JVNDB", "id": "JVNDB-2020-005434" }, { "db": "NVD", "id": "CVE-2020-11999" }, { "db": "CNNVD", "id": "CNNVD-202006-918" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. An exposed API call allows users to provide files to be processed without sanitation. This may allow an attacker to specify a filename to execute unauthorized code and modify files or data. Rockwell Automation Provided by the company FactoryTalk Linx Software The following multiple vulnerabilities exist in. * Improper input confirmation (CWE-20) - CVE-2020-11999 * Improper input confirmation (CWE-20) - CVE-2020-12001 * Directory traversal (CWE-22) - CVE-2020-12003 * Upload any file (CWE-434) - CVE-2020-12005The expected impact depends on each vulnerability, but it may be affected as follows. * API Arbitrary code may be executed or files or data may be tampered with by a remote third party because arbitrary files are not properly sanitized during a call. - CVE-2020-11999 * Proper sanitization of specially crafted files can lead to sensitive information being stolen or arbitrary code being executed by a remote third party. - CVE-2020-12001 * API Sensitive information on the local hard drive is stolen by a remote third party because it does not properly sanitize the specially crafted request during the call. - CVE-2020-12003 * Improperly compressed by a remote third party EDF By uploading the file, the compressed file can be decompressed. CPU All resources are consumed and service operation is interrupted (DoS) The condition is triggered - CVE-2020-12005. Rockwell Automation RSLinx Classic and others are products of Rockwell Automation (USA). Rockwell Automation RSLinx Classic is a set of industrial communication solutions. Rockwell Automation ControlFLASH is a firmware update utility", "sources": [ { "db": "NVD", "id": "CVE-2020-11999" }, { "db": "JVNDB", "id": "JVNDB-2020-005434" }, { "db": "CNVD", "id": "CNVD-2020-38696" }, { "db": "VULHUB", "id": "VHN-164633" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-11999", "trust": 3.1 }, { "db": "ICS CERT", "id": "ICSA-20-163-02", "trust": 3.1 }, { "db": "JVN", "id": "JVNVU91454414", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2020-005434", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2020-38696", "trust": 0.7 }, { "db": "CNNVD", "id": "CNNVD-202006-918", "trust": 0.7 }, { "db": "AUSCERT", "id": "ESB-2020.2062", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-164633", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-38696" }, { "db": "VULHUB", "id": "VHN-164633" }, { "db": "JVNDB", "id": "JVNDB-2020-005434" }, { "db": "NVD", "id": "CVE-2020-11999" }, { "db": "CNNVD", "id": "CNNVD-202006-918" } ] }, "id": "VAR-202006-0317", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2020-38696" }, { "db": "VULHUB", "id": "VHN-164633" } ], "trust": 1.4526883266666666 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-38696" } ] }, "last_update_date": "2023-12-18T13:07:35.616000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "54102-Industrial Security Advisory Index (\u8981\u30ed\u30b0\u30a4\u30f3)", "trust": 0.8, "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/54102" }, { "title": "Patch for Multiple Rockwell Automation product input validation error vulnerabilities", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/225409" }, { "title": "Multiple Rockwell Automation Product input verification error vulnerability fixes", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=122477" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-38696" }, { "db": "JVNDB", "id": "JVNDB-2020-005434" }, { "db": "CNNVD", "id": "CNNVD-202006-918" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-20", "trust": 1.1 } ], "sources": [ { "db": "VULHUB", "id": "VHN-164633" }, { "db": "NVD", "id": "CVE-2020-11999" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.1, "url": "https://www.us-cert.gov/ics/advisories/icsa-20-163-02" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-11999" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-12003" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-12005" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-11999" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-12001" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu91454414/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-12001" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-12003" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-12005" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2020.2062/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-38696" }, { "db": "VULHUB", "id": "VHN-164633" }, { "db": "JVNDB", "id": "JVNDB-2020-005434" }, { "db": "NVD", "id": "CVE-2020-11999" }, { "db": "CNNVD", "id": "CNNVD-202006-918" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2020-38696" }, { "db": "VULHUB", "id": "VHN-164633" }, { "db": "JVNDB", "id": "JVNDB-2020-005434" }, { "db": "NVD", "id": "CVE-2020-11999" }, { "db": "CNNVD", "id": "CNNVD-202006-918" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-07-14T00:00:00", "db": "CNVD", "id": "CNVD-2020-38696" }, { "date": "2020-06-15T00:00:00", "db": "VULHUB", "id": "VHN-164633" }, { "date": "2020-06-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-005434" }, { "date": "2020-06-15T20:15:11.223000", "db": "NVD", "id": "CVE-2020-11999" }, { "date": "2020-06-11T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-918" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-07-14T00:00:00", "db": "CNVD", "id": "CNVD-2020-38696" }, { "date": "2020-06-24T00:00:00", "db": "VULHUB", "id": "VHN-164633" }, { "date": "2020-07-13T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-005434" }, { "date": "2020-06-24T14:50:12.090000", "db": "NVD", "id": "CVE-2020-11999" }, { "date": "2020-06-30T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-918" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-918" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Rockwell Automation Made FactoryTalk Linx Software Multiple vulnerabilities in", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-005434" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "input validation error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-918" } ], "trust": 0.6 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.