Vulnerability from variot - Updated: 2023-12-18 13:42A stack-based buffer overflow on DrayTek Vigor2960, Vigor3900, and Vigor300B devices before 1.5.1.1 allows remote attackers to execute arbitrary code via the formuserphonenumber parameter in an authusersms action to mainfunction.cgi. Draytek Vigor2960 , Vigor3900 , Vigor300B The device is vulnerable to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. DrayTek Vigor3900, etc. are all products of DrayTek, Taiwan, China. DrayTek Vigor3900 is a broadband router/VPN gateway device. Vigor2960 is a load balancing router and VPN gateway device. Vigor300B is a load balancing router.
There is a buffer overflow vulnerability in DrayTek Vigor2960, Vigor3900 and Vigor300B versions before 1.5.1.1
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202006-1005",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "vigor3900",
"scope": "lt",
"trust": 1.6,
"vendor": "draytek",
"version": "1.5.1.1"
},
{
"model": "vigor2960",
"scope": "lt",
"trust": 1.6,
"vendor": "draytek",
"version": "1.5.1.1"
},
{
"model": "vigor300b",
"scope": "lt",
"trust": 1.6,
"vendor": "draytek",
"version": "1.5.1.1"
},
{
"model": "vigor2960",
"scope": "eq",
"trust": 0.8,
"vendor": "draytek",
"version": "1.5.1.1"
},
{
"model": "vigor3900",
"scope": "eq",
"trust": 0.8,
"vendor": "draytek",
"version": "1.5.1.1"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21944"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007077"
},
{
"db": "NVD",
"id": "CVE-2020-14993"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:draytek:vigor300b_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.5.1.1",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:draytek:vigor300b:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:draytek:vigor2960_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.5.1.1",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:draytek:vigor2960:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:draytek:vigor3900_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.5.1.1",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:draytek:vigor3900:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-14993"
}
]
},
"cve": "CVE-2020-14993",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 7.5,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "JVNDB-2020-007077",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2021-21944",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2020-007077",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2020-14993",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "JVNDB-2020-007077",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2021-21944",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202006-1596",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21944"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007077"
},
{
"db": "NVD",
"id": "CVE-2020-14993"
},
{
"db": "CNNVD",
"id": "CNNVD-202006-1596"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A stack-based buffer overflow on DrayTek Vigor2960, Vigor3900, and Vigor300B devices before 1.5.1.1 allows remote attackers to execute arbitrary code via the formuserphonenumber parameter in an authusersms action to mainfunction.cgi. Draytek Vigor2960 , Vigor3900 , Vigor300B The device is vulnerable to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. DrayTek Vigor3900, etc. are all products of DrayTek, Taiwan, China. DrayTek Vigor3900 is a broadband router/VPN gateway device. Vigor2960 is a load balancing router and VPN gateway device. Vigor300B is a load balancing router. \n\r\n\r\nThere is a buffer overflow vulnerability in DrayTek Vigor2960, Vigor3900 and Vigor300B versions before 1.5.1.1",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-14993"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007077"
},
{
"db": "CNVD",
"id": "CNVD-2021-21944"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2020-14993",
"trust": 3.0
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007077",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2021-21944",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202006-1596",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21944"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007077"
},
{
"db": "NVD",
"id": "CVE-2020-14993"
},
{
"db": "CNNVD",
"id": "CNNVD-202006-1596"
}
]
},
"id": "VAR-202006-1005",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21944"
}
],
"trust": 1.2428176466666667
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21944"
}
]
},
"last_update_date": "2023-12-18T13:42:53.946000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Vigor3900 / Vigor2960 / Vigor300B Stack-based buffer overflow Vulnerability (CVE-2020-14473 / CVE-2020-14993)",
"trust": 0.8,
"url": "https://www.draytek.com/about/security-advisory/vigor3900-/-vigor2960-/-vigor300b-stack-based-buffer-overflow-vulnerability-(cve-2020-14473)"
},
{
"title": "DrayTek Security Advisory",
"trust": 0.8,
"url": "https://www.draytek.com/about/security-advisory"
},
{
"title": "Patches for DrayTek Vigor2960, Vigor3900 and Vigor300B flushing area overflow vulnerabilities",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/254556"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21944"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007077"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-007077"
},
{
"db": "NVD",
"id": "CVE-2020-14993"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.0,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-14993"
},
{
"trust": 1.6,
"url": "https://github.com/dexterone/vigor-poc"
},
{
"trust": 1.6,
"url": "https://www.draytek.com/about/security-advisory"
},
{
"trust": 1.0,
"url": "https://www.draytek.com/about/security-advisory/vigor3900-/-vigor2960-/-vigor300b-stack-based-buffer-overflow-vulnerability-%28cve-2020-14473%29"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-14993"
},
{
"trust": 0.6,
"url": "https://www.draytek.com/about/security-advisory/vigor3900-/-vigor2960-/-vigor300b-stack-based-buffer-overflow-vulnerability-(cve-2020-14473)"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-21944"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007077"
},
{
"db": "NVD",
"id": "CVE-2020-14993"
},
{
"db": "CNNVD",
"id": "CNNVD-202006-1596"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2021-21944"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-007077"
},
{
"db": "NVD",
"id": "CVE-2020-14993"
},
{
"db": "CNNVD",
"id": "CNNVD-202006-1596"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-03-24T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-21944"
},
{
"date": "2020-07-30T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-007077"
},
{
"date": "2020-06-23T12:15:13.503000",
"db": "NVD",
"id": "CVE-2020-14993"
},
{
"date": "2020-06-23T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202006-1596"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-04-13T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-21944"
},
{
"date": "2020-07-30T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-007077"
},
{
"date": "2023-11-07T03:17:23.410000",
"db": "NVD",
"id": "CVE-2020-14993"
},
{
"date": "2020-06-30T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202006-1596"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202006-1596"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural DrayTek Out-of-bounds write vulnerabilities in product devices",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-007077"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202006-1596"
}
],
"trust": 0.6
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.