var-202007-1249
Vulnerability from variot

A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted. This could allow a local attacker with administrative privileges to execute code with SYSTEM level privileges. Multiple Siemens products contain vulnerabilities in unquoted search paths or elements.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. A code issue vulnerability exists in Siemens. This vulnerability stems from improper design or implementation problems in the code development process of network systems or products

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202007-1249",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "simatic step 7",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "16"
      },
      {
        "model": "simocode es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "soft starter es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic notifier server",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "opcenter intelligence",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic pcs neo",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "opcenter execution discrete",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.2"
      },
      {
        "model": "opcenter quality",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "11.3"
      },
      {
        "model": "simatic step 7",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "16"
      },
      {
        "model": "opcenter rd\\\u0026l",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "8.0"
      },
      {
        "model": "opcenter execution foundation",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.2"
      },
      {
        "model": "opcenter execution process",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.2"
      },
      {
        "model": "opcenter execution discrete",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "3.2"
      },
      {
        "model": "opcenter execution foundation",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "3.2"
      },
      {
        "model": "opcenter execution process",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "3.2"
      },
      {
        "model": "opcenter intelligence",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "opcenter quality",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "11.3"
      },
      {
        "model": "opcenter rd\u002626l",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "8.0"
      },
      {
        "model": "simatic notifier server",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic pcs neo",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "3.0 sp1"
      },
      {
        "model": "simatic step 7",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "15.1 update 5"
      },
      {
        "model": "simatic step 7",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "16 update 2"
      },
      {
        "model": "simocode es",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008611"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-7581"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:opcenter_execution_discrete:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "3.2",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:opcenter_execution_foundation:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "3.2",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:opcenter_execution_process:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "3.2",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:opcenter_intelligence:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:opcenter_quality:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "11.3",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:opcenter_rd\\\u0026l:8.0:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_step_7:16:update1:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_step_7:16:-:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "16",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:soft_starter_es:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simocode_es:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_notifier_server:*:*:*:*:*:windows:*:*",
                "cpe_name": [],
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-7581"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Victor Fidalgo of INCIBE and Reid Wightman of Dragos reported these vulnerabilities to Siemens.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202007-574"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2020-7581",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.2,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 3.9,
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "HIGH",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Local",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Complete",
            "baseScore": 7.2,
            "confidentialityImpact": "Complete",
            "exploitabilityScore": null,
            "id": "JVNDB-2020-008611",
            "impactScore": null,
            "integrityImpact": "Complete",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.2,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 3.9,
            "id": "VHN-185706",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:L/AC:L/AU:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "author": "VULMON",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.2,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2020-7581",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "HIGH",
            "trust": 0.1,
            "userInteractionRequired": null,
            "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 6.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 0.8,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Local",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 6.7,
            "baseSeverity": "Medium",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2020-008611",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "High",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2020-7581",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "JVNDB-2020-008611",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202007-574",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "VULHUB",
            "id": "VHN-185706",
            "trust": 0.1,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2020-7581",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-185706"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-7581"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008611"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-7581"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202007-574"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in Opcenter Execution Discrete (All versions \u003c V3.2), Opcenter Execution Foundation (All versions \u003c V3.2), Opcenter Execution Process (All versions \u003c V3.2), Opcenter Intelligence (All versions \u003c V3.3), Opcenter Quality (All versions \u003c V11.3), Opcenter RD\u0026L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMOCODE ES V15.1 (All versions \u003c V15.1 Update 4), SIMOCODE ES V16 (All versions \u003c V16 Update 1), Soft Starter ES V15.1 (All versions \u003c V15.1 Update 3), Soft Starter ES V16 (All versions \u003c V16 Update 1). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted. This could allow a local attacker with administrative privileges to execute code with SYSTEM level privileges. Multiple Siemens products contain vulnerabilities in unquoted search paths or elements.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. A code issue vulnerability exists in Siemens. This vulnerability stems from improper design or implementation problems in the code development process of network systems or products",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-7581"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008611"
      },
      {
        "db": "VULHUB",
        "id": "VHN-185706"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-7581"
      }
    ],
    "trust": 1.8
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-7581",
        "trust": 2.6
      },
      {
        "db": "SIEMENS",
        "id": "SSA-841348",
        "trust": 1.8
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-20-196-05",
        "trust": 1.4
      },
      {
        "db": "JVN",
        "id": "JVNVU97872642",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008611",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202007-574",
        "trust": 0.7
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2020.2393.2",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2020.2393",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-185706",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-7581",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-185706"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-7581"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008611"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-7581"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202007-574"
      }
    ]
  },
  "id": "VAR-202007-1249",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-185706"
      }
    ],
    "trust": 0.7076922999999999
  },
  "last_update_date": "2023-12-18T11:58:11.084000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-841348",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf"
      },
      {
        "title": "Siemens Security Advisories: Siemens Security Advisory",
        "trust": 0.1,
        "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=2c5193074a957cb3ecdc0e93e2ad86b5"
      },
      {
        "title": "",
        "trust": 0.1,
        "url": "https://github.com/live-hack-cve/cve-2020-7581 "
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2020-7581"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008611"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-428",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-185706"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008611"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-7581"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf"
      },
      {
        "trust": 1.4,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-196-05"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-7581"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-7581"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu97872642/"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2020.2393.2/"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2020.2393/"
      },
      {
        "trust": 0.6,
        "url": "https://vigilance.fr/vulnerability/simatic-multiple-vulnerabilities-via-umc-stack-32813"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/428.html"
      },
      {
        "trust": 0.1,
        "url": "https://github.com/live-hack-cve/cve-2020-7581"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://cert-portal.siemens.com/productcert/txt/ssa-841348.txt"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-185706"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-7581"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008611"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-7581"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202007-574"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULHUB",
        "id": "VHN-185706"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-7581"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008611"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-7581"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202007-574"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-07-14T00:00:00",
        "db": "VULHUB",
        "id": "VHN-185706"
      },
      {
        "date": "2020-07-14T00:00:00",
        "db": "VULMON",
        "id": "CVE-2020-7581"
      },
      {
        "date": "2020-09-17T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-008611"
      },
      {
        "date": "2020-07-14T14:15:18.587000",
        "db": "NVD",
        "id": "CVE-2020-7581"
      },
      {
        "date": "2020-07-14T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202007-574"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-01-30T00:00:00",
        "db": "VULHUB",
        "id": "VHN-185706"
      },
      {
        "date": "2023-01-30T00:00:00",
        "db": "VULMON",
        "id": "CVE-2020-7581"
      },
      {
        "date": "2020-09-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-008611"
      },
      {
        "date": "2023-01-30T19:54:07.110000",
        "db": "NVD",
        "id": "CVE-2020-7581"
      },
      {
        "date": "2022-08-11T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202007-574"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202007-574"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Vulnerabilities in unquoted search paths or elements in multiple Siemens products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008611"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "code problem",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202007-574"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.