var-202008-0979
Vulnerability from variot
An information disclosure vulnerability exists in EdgeMax EdgeSwitch firmware v1.9.0 that allowed read only users could obtain unauthorized information through SNMP community pages. EdgeMax EdgeSwitch There is an information leakage vulnerability in the firmware.Information may be obtained. Ubiquiti Networks EdgeMAX EdgeSwitch is a PoE+ Gigabit switch from Ubiquiti Networks
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202008-0979", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "edgeswitch", "scope": "lt", "trust": 1.0, "vendor": "ui", "version": "1.9.0" }, { "model": "edgeswitch", "scope": null, "trust": 0.8, "vendor": "ubiquiti", "version": null }, { "model": "networks ubiquiti networks edgemax edgeswitch", "scope": "eq", "trust": 0.6, "vendor": "ubiquiti", "version": "1.9.0" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-46805" }, { "db": "JVNDB", "id": "JVNDB-2020-009587" }, { "db": "NVD", "id": "CVE-2020-8232" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:ui:edgeswitch_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.9.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:ui:ep-16-xg:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:ui:ep-s16:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:ui:es-12f:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:ui:es-16-150w:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:ui:es-24-250w:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:ui:es-24-500w:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:ui:es-24-lite:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:ui:es-48-500w:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:ui:es-48-750w:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:ui:es-48-lite:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:ui:es-8-150w:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-8232" } ] }, "cve": "CVE-2020-8232", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 4.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.0, "impactScore": 2.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "None", "baseScore": 4.0, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2020-009587", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CNVD-2020-46805", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 6.5, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-009587", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-8232", "trust": 1.0, "value": "MEDIUM" }, { "author": "NVD", "id": "JVNDB-2020-009587", "trust": 0.8, "value": "Medium" }, { "author": "CNVD", "id": "CNVD-2020-46805", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202008-857", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-46805" }, { "db": "JVNDB", "id": "JVNDB-2020-009587" }, { "db": "NVD", "id": "CVE-2020-8232" }, { "db": "CNNVD", "id": "CNNVD-202008-857" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "An information disclosure vulnerability exists in EdgeMax EdgeSwitch firmware v1.9.0 that allowed read only users could obtain unauthorized information through SNMP community pages. EdgeMax EdgeSwitch There is an information leakage vulnerability in the firmware.Information may be obtained. Ubiquiti Networks EdgeMAX EdgeSwitch is a PoE+ Gigabit switch from Ubiquiti Networks", "sources": [ { "db": "NVD", "id": "CVE-2020-8232" }, { "db": "JVNDB", "id": "JVNDB-2020-009587" }, { "db": "CNVD", "id": "CNVD-2020-46805" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-8232", "trust": 3.0 }, { "db": "JVNDB", "id": "JVNDB-2020-009587", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2020-46805", "trust": 0.6 }, { "db": "NSFOCUS", "id": "48739", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202008-857", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-46805" }, { "db": "JVNDB", "id": "JVNDB-2020-009587" }, { "db": "NVD", "id": "CVE-2020-8232" }, { "db": "CNNVD", "id": "CNNVD-202008-857" } ] }, "id": "VAR-202008-0979", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2020-46805" } ], "trust": 1.2269231 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-46805" } ] }, "last_update_date": "2023-12-18T12:27:19.766000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security advisory bulletin 014", "trust": 0.8, "url": "https://community.ui.com/releases/security-advisory-bulletin-014-014/1c32c056-2c64-4e60-ac23-ce7d8f387821" }, { "title": "EdgeMAX EdgeSwitch Firmware v1.9.1", "trust": 0.8, "url": "https://community.ui.com/releases/edgemax-edgeswitch-firmware-v1-9-1-v1-9-1/8a87dfc5-70f5-4055-8d67-570db1f5695c" }, { "title": "EdgeMAX", "trust": 0.8, "url": "https://www.ui.com/download/edgemax/" }, { "title": "Patch for EdgeSwitch firmware information disclosure vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/231064" }, { "title": "Ubiquiti Network EdgeMax EdgeSwitch Repair measures for information disclosure vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=126544" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-46805" }, { "db": "JVNDB", "id": "JVNDB-2020-009587" }, { "db": "CNNVD", "id": "CNNVD-202008-857" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-200", "trust": 1.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-009587" }, { "db": "NVD", "id": "CVE-2020-8232" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-8232" }, { "trust": 1.6, "url": "https://community.ui.com/releases/edgemax-edgeswitch-firmware-v1-9-1-v1-9-1/8a87dfc5-70f5-4055-8d67-570db1f5695c" }, { "trust": 1.6, "url": "https://community.ui.com/releases/security-advisory-bulletin-014-014/1c32c056-2c64-4e60-ac23-ce7d8f387821" }, { "trust": 1.6, "url": "https://www.ui.com/download/edgemax" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-8232" }, { "trust": 0.6, "url": "http://www.nsfocus.net/vulndb/48739" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-46805" }, { "db": "JVNDB", "id": "JVNDB-2020-009587" }, { "db": "NVD", "id": "CVE-2020-8232" }, { "db": "CNNVD", "id": "CNNVD-202008-857" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2020-46805" }, { "db": "JVNDB", "id": "JVNDB-2020-009587" }, { "db": "NVD", "id": "CVE-2020-8232" }, { "db": "CNNVD", "id": "CNNVD-202008-857" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-08-19T00:00:00", "db": "CNVD", "id": "CNVD-2020-46805" }, { "date": "2020-11-19T05:37:46", "db": "JVNDB", "id": "JVNDB-2020-009587" }, { "date": "2020-08-17T16:15:13.780000", "db": "NVD", "id": "CVE-2020-8232" }, { "date": "2020-08-17T00:00:00", "db": "CNNVD", "id": "CNNVD-202008-857" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-08-19T00:00:00", "db": "CNVD", "id": "CNVD-2020-46805" }, { "date": "2020-11-19T05:37:46", "db": "JVNDB", "id": "JVNDB-2020-009587" }, { "date": "2021-09-23T13:57:02.790000", "db": "NVD", "id": "CVE-2020-8232" }, { "date": "2020-09-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202008-857" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202008-857" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "EdgeMax EdgeSwitch Information leakage vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-009587" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "information disclosure", "sources": [ { "db": "CNNVD", "id": "CNNVD-202008-857" } ], "trust": 0.6 } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.