VAR-202008-0979
Vulnerability from variot - Updated: 2023-12-18 12:27An information disclosure vulnerability exists in EdgeMax EdgeSwitch firmware v1.9.0 that allowed read only users could obtain unauthorized information through SNMP community pages. EdgeMax EdgeSwitch There is an information leakage vulnerability in the firmware.Information may be obtained. Ubiquiti Networks EdgeMAX EdgeSwitch is a PoE+ Gigabit switch from Ubiquiti Networks
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202008-0979",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "edgeswitch",
"scope": "lt",
"trust": 1.0,
"vendor": "ui",
"version": "1.9.0"
},
{
"model": "edgeswitch",
"scope": null,
"trust": 0.8,
"vendor": "ubiquiti",
"version": null
},
{
"model": "networks ubiquiti networks edgemax edgeswitch",
"scope": "eq",
"trust": 0.6,
"vendor": "ubiquiti",
"version": "1.9.0"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-46805"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009587"
},
{
"db": "NVD",
"id": "CVE-2020-8232"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:ui:edgeswitch_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.9.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:ui:ep-16-xg:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:ui:ep-s16:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:ui:es-12f:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:ui:es-16-150w:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:ui:es-24-250w:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:ui:es-24-500w:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:ui:es-24-lite:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:ui:es-48-500w:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:ui:es-48-750w:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:ui:es-48-lite:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:ui:es-8-150w:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-8232"
}
]
},
"cve": "CVE-2020-8232",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 4.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 4.0,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "JVNDB-2020-009587",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2020-46805",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 6.5,
"baseSeverity": "Medium",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2020-009587",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2020-8232",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "JVNDB-2020-009587",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNVD",
"id": "CNVD-2020-46805",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202008-857",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-46805"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009587"
},
{
"db": "NVD",
"id": "CVE-2020-8232"
},
{
"db": "CNNVD",
"id": "CNNVD-202008-857"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "An information disclosure vulnerability exists in EdgeMax EdgeSwitch firmware v1.9.0 that allowed read only users could obtain unauthorized information through SNMP community pages. EdgeMax EdgeSwitch There is an information leakage vulnerability in the firmware.Information may be obtained. Ubiquiti Networks EdgeMAX EdgeSwitch is a PoE+ Gigabit switch from Ubiquiti Networks",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-8232"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009587"
},
{
"db": "CNVD",
"id": "CNVD-2020-46805"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2020-8232",
"trust": 3.0
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009587",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2020-46805",
"trust": 0.6
},
{
"db": "NSFOCUS",
"id": "48739",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202008-857",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-46805"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009587"
},
{
"db": "NVD",
"id": "CVE-2020-8232"
},
{
"db": "CNNVD",
"id": "CNNVD-202008-857"
}
]
},
"id": "VAR-202008-0979",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-46805"
}
],
"trust": 1.2269231
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-46805"
}
]
},
"last_update_date": "2023-12-18T12:27:19.766000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Security advisory bulletin 014",
"trust": 0.8,
"url": "https://community.ui.com/releases/security-advisory-bulletin-014-014/1c32c056-2c64-4e60-ac23-ce7d8f387821"
},
{
"title": "EdgeMAX EdgeSwitch Firmware v1.9.1",
"trust": 0.8,
"url": "https://community.ui.com/releases/edgemax-edgeswitch-firmware-v1-9-1-v1-9-1/8a87dfc5-70f5-4055-8d67-570db1f5695c"
},
{
"title": "EdgeMAX",
"trust": 0.8,
"url": "https://www.ui.com/download/edgemax/"
},
{
"title": "Patch for EdgeSwitch firmware information disclosure vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/231064"
},
{
"title": "Ubiquiti Network EdgeMax EdgeSwitch Repair measures for information disclosure vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=126544"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-46805"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009587"
},
{
"db": "CNNVD",
"id": "CNNVD-202008-857"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-200",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-009587"
},
{
"db": "NVD",
"id": "CVE-2020-8232"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.0,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-8232"
},
{
"trust": 1.6,
"url": "https://community.ui.com/releases/edgemax-edgeswitch-firmware-v1-9-1-v1-9-1/8a87dfc5-70f5-4055-8d67-570db1f5695c"
},
{
"trust": 1.6,
"url": "https://community.ui.com/releases/security-advisory-bulletin-014-014/1c32c056-2c64-4e60-ac23-ce7d8f387821"
},
{
"trust": 1.6,
"url": "https://www.ui.com/download/edgemax"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-8232"
},
{
"trust": 0.6,
"url": "http://www.nsfocus.net/vulndb/48739"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-46805"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009587"
},
{
"db": "NVD",
"id": "CVE-2020-8232"
},
{
"db": "CNNVD",
"id": "CNNVD-202008-857"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2020-46805"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-009587"
},
{
"db": "NVD",
"id": "CVE-2020-8232"
},
{
"db": "CNNVD",
"id": "CNNVD-202008-857"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-08-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-46805"
},
{
"date": "2020-11-19T05:37:46",
"db": "JVNDB",
"id": "JVNDB-2020-009587"
},
{
"date": "2020-08-17T16:15:13.780000",
"db": "NVD",
"id": "CVE-2020-8232"
},
{
"date": "2020-08-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202008-857"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-08-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-46805"
},
{
"date": "2020-11-19T05:37:46",
"db": "JVNDB",
"id": "JVNDB-2020-009587"
},
{
"date": "2021-09-23T13:57:02.790000",
"db": "NVD",
"id": "CVE-2020-8232"
},
{
"date": "2020-09-14T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202008-857"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202008-857"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "EdgeMax EdgeSwitch Information leakage vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-009587"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "information disclosure",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202008-857"
}
],
"trust": 0.6
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.