var-202009-0051
Vulnerability from variot

A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V2.10.2). The start-stop scripts for the services of the affected application could allow a local attacker to include arbitrary commands that are executed when services are started or stopped interactively by system administrators. SIMATIC RTLS Locating Manager Is vulnerable to incorrect default permissions.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. SIMATIC RTLS is a real-time wireless positioning system for positioning solutions. Siemens SIMATIC RTLS Locating Manager is used for the configuration, operation and maintenance of SIMATIC RTLS installation. Attackers can use vulnerabilities to execute arbitrary commands

Show details on source website


{
   "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
      affected_products: {
         "@id": "https://www.variotdbs.pl/ref/affected_products",
      },
      configurations: {
         "@id": "https://www.variotdbs.pl/ref/configurations",
      },
      credits: {
         "@id": "https://www.variotdbs.pl/ref/credits",
      },
      cvss: {
         "@id": "https://www.variotdbs.pl/ref/cvss/",
      },
      description: {
         "@id": "https://www.variotdbs.pl/ref/description/",
      },
      exploit_availability: {
         "@id": "https://www.variotdbs.pl/ref/exploit_availability/",
      },
      external_ids: {
         "@id": "https://www.variotdbs.pl/ref/external_ids/",
      },
      iot: {
         "@id": "https://www.variotdbs.pl/ref/iot/",
      },
      iot_taxonomy: {
         "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/",
      },
      patch: {
         "@id": "https://www.variotdbs.pl/ref/patch/",
      },
      problemtype_data: {
         "@id": "https://www.variotdbs.pl/ref/problemtype_data/",
      },
      references: {
         "@id": "https://www.variotdbs.pl/ref/references/",
      },
      sources: {
         "@id": "https://www.variotdbs.pl/ref/sources/",
      },
      sources_release_date: {
         "@id": "https://www.variotdbs.pl/ref/sources_release_date/",
      },
      sources_update_date: {
         "@id": "https://www.variotdbs.pl/ref/sources_update_date/",
      },
      threat_type: {
         "@id": "https://www.variotdbs.pl/ref/threat_type/",
      },
      title: {
         "@id": "https://www.variotdbs.pl/ref/title/",
      },
      type: {
         "@id": "https://www.variotdbs.pl/ref/type/",
      },
   },
   "@id": "https://www.variotdbs.pl/vuln/VAR-202009-0051",
   affected_products: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
            "@id": "https://www.variotdbs.pl/ref/sources",
         },
      },
      data: [
         {
            model: "simatic rtls locating manager",
            scope: "lt",
            trust: 1.6,
            vendor: "siemens",
            version: "2.10.2",
         },
         {
            model: "simatic rtls locating manager",
            scope: "eq",
            trust: 0.8,
            vendor: "シーメンス",
            version: "2.10.2",
         },
         {
            model: "simatic rtls locating manager",
            scope: "eq",
            trust: 0.8,
            vendor: "シーメンス",
            version: null,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2020-51251",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2020-010865",
         },
         {
            db: "NVD",
            id: "CVE-2020-10049",
         },
      ],
   },
   configurations: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/configurations#",
         children: {
            "@container": "@list",
         },
         cpe_match: {
            "@container": "@list",
         },
         data: {
            "@container": "@list",
         },
         nodes: {
            "@container": "@list",
         },
      },
      data: [
         {
            CVE_data_version: "4.0",
            nodes: [
               {
                  children: [],
                  cpe_match: [
                     {
                        cpe23Uri: "cpe:2.3:a:siemens:simatic_rtls_locating_manager:*:*:*:*:*:*:*:*",
                        cpe_name: [],
                        versionEndExcluding: "2.10.2",
                        vulnerable: true,
                     },
                  ],
                  operator: "OR",
               },
            ],
         },
      ],
      sources: [
         {
            db: "NVD",
            id: "CVE-2020-10049",
         },
      ],
   },
   cve: "CVE-2020-10049",
   cvss: {
      "@context": {
         cvssV2: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2",
         },
         cvssV3: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/",
         },
         severity: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/cvss/severity#",
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
            "@id": "https://www.variotdbs.pl/ref/sources",
         },
      },
      data: [
         {
            cvssV2: [
               {
                  acInsufInfo: false,
                  accessComplexity: "MEDIUM",
                  accessVector: "LOCAL",
                  authentication: "NONE",
                  author: "NVD",
                  availabilityImpact: "PARTIAL",
                  baseScore: 4.4,
                  confidentialityImpact: "PARTIAL",
                  exploitabilityScore: 3.4,
                  impactScore: 6.4,
                  integrityImpact: "PARTIAL",
                  obtainAllPrivilege: false,
                  obtainOtherPrivilege: false,
                  obtainUserPrivilege: false,
                  severity: "MEDIUM",
                  trust: 1,
                  userInteractionRequired: true,
                  vectorString: "AV:L/AC:M/Au:N/C:P/I:P/A:P",
                  version: "2.0",
               },
               {
                  acInsufInfo: null,
                  accessComplexity: "Medium",
                  accessVector: "Local",
                  authentication: "None",
                  author: "NVD",
                  availabilityImpact: "Partial",
                  baseScore: 4.4,
                  confidentialityImpact: "Partial",
                  exploitabilityScore: null,
                  id: "CVE-2020-10049",
                  impactScore: null,
                  integrityImpact: "Partial",
                  obtainAllPrivilege: null,
                  obtainOtherPrivilege: null,
                  obtainUserPrivilege: null,
                  severity: "Medium",
                  trust: 0.8,
                  userInteractionRequired: null,
                  vectorString: "AV:L/AC:M/Au:N/C:P/I:P/A:P",
                  version: "2.0",
               },
               {
                  accessComplexity: "LOW",
                  accessVector: "LOCAL",
                  authentication: "NONE",
                  author: "CNVD",
                  availabilityImpact: "NONE",
                  baseScore: 6.6,
                  confidentialityImpact: "COMPLETE",
                  exploitabilityScore: 3.9,
                  id: "CNVD-2020-51251",
                  impactScore: 9.2,
                  integrityImpact: "COMPLETE",
                  severity: "MEDIUM",
                  trust: 0.6,
                  vectorString: "AV:L/AC:L/Au:N/C:C/I:C/A:N",
                  version: "2.0",
               },
            ],
            cvssV3: [
               {
                  attackComplexity: "LOW",
                  attackVector: "LOCAL",
                  author: "NVD",
                  availabilityImpact: "HIGH",
                  baseScore: 7.3,
                  baseSeverity: "HIGH",
                  confidentialityImpact: "HIGH",
                  exploitabilityScore: 1.3,
                  impactScore: 5.9,
                  integrityImpact: "HIGH",
                  privilegesRequired: "LOW",
                  scope: "UNCHANGED",
                  trust: 1,
                  userInteraction: "REQUIRED",
                  vectorString: "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
                  version: "3.1",
               },
               {
                  attackComplexity: "Low",
                  attackVector: "Local",
                  author: "NVD",
                  availabilityImpact: "High",
                  baseScore: 7.3,
                  baseSeverity: "High",
                  confidentialityImpact: "High",
                  exploitabilityScore: null,
                  id: "CVE-2020-10049",
                  impactScore: null,
                  integrityImpact: "High",
                  privilegesRequired: "Low",
                  scope: "Unchanged",
                  trust: 0.8,
                  userInteraction: "Required",
                  vectorString: "CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
                  version: "3.0",
               },
            ],
            severity: [
               {
                  author: "NVD",
                  id: "CVE-2020-10049",
                  trust: 1.8,
                  value: "HIGH",
               },
               {
                  author: "CNVD",
                  id: "CNVD-2020-51251",
                  trust: 0.6,
                  value: "MEDIUM",
               },
               {
                  author: "CNNVD",
                  id: "CNNVD-202009-513",
                  trust: 0.6,
                  value: "HIGH",
               },
            ],
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2020-51251",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2020-010865",
         },
         {
            db: "NVD",
            id: "CVE-2020-10049",
         },
         {
            db: "CNNVD",
            id: "CNNVD-202009-513",
         },
      ],
   },
   description: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/description#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: "A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V2.10.2). The start-stop scripts for the services of the affected application could allow a local attacker to include arbitrary commands that are executed when services are started or stopped interactively by system administrators. SIMATIC RTLS Locating Manager Is vulnerable to incorrect default permissions.Information is obtained, information is tampered with, and service is disrupted  (DoS) It may be put into a state. SIMATIC RTLS is a real-time wireless positioning system for positioning solutions. Siemens SIMATIC RTLS Locating Manager is used for the configuration, operation and maintenance of SIMATIC RTLS installation. Attackers can use vulnerabilities to execute arbitrary commands",
      sources: [
         {
            db: "NVD",
            id: "CVE-2020-10049",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2020-010865",
         },
         {
            db: "CNVD",
            id: "CNVD-2020-51251",
         },
      ],
      trust: 2.16,
   },
   external_ids: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            db: "NVD",
            id: "CVE-2020-10049",
            trust: 3.8,
         },
         {
            db: "SIEMENS",
            id: "SSA-251935",
            trust: 2.2,
         },
         {
            db: "ICS CERT",
            id: "ICSA-20-252-01",
            trust: 1.4,
         },
         {
            db: "JVN",
            id: "JVNVU94568336",
            trust: 0.8,
         },
         {
            db: "JVNDB",
            id: "JVNDB-2020-010865",
            trust: 0.8,
         },
         {
            db: "CNVD",
            id: "CNVD-2020-51251",
            trust: 0.6,
         },
         {
            db: "NSFOCUS",
            id: "50586",
            trust: 0.6,
         },
         {
            db: "AUSCERT",
            id: "ESB-2020.3078",
            trust: 0.6,
         },
         {
            db: "CNNVD",
            id: "CNNVD-202009-513",
            trust: 0.6,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2020-51251",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2020-010865",
         },
         {
            db: "NVD",
            id: "CVE-2020-10049",
         },
         {
            db: "CNNVD",
            id: "CNNVD-202009-513",
         },
      ],
   },
   id: "VAR-202009-0051",
   iot: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/iot#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: true,
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2020-51251",
         },
      ],
      trust: 0.975,
   },
   iot_taxonomy: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            category: [
               "ICS",
            ],
            sub_category: null,
            trust: 0.6,
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2020-51251",
         },
      ],
   },
   last_update_date: "2023-12-18T11:25:14.370000Z",
   patch: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/patch#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            title: "SSA-251935",
            trust: 0.8,
            url: "https://cert-portal.siemens.com/productcert/pdf/ssa-251935.pdf",
         },
         {
            title: "Patch for Siemens SIMATIC RTLS Locating Manager Privilege Escalation Vulnerability",
            trust: 0.6,
            url: "https://www.cnvd.org.cn/patchinfo/show/233317",
         },
         {
            title: "ARC Security vulnerabilities",
            trust: 0.6,
            url: "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=127932",
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2020-51251",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2020-010865",
         },
         {
            db: "CNNVD",
            id: "CNNVD-202009-513",
         },
      ],
   },
   problemtype_data: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            problemtype: "CWE-276",
            trust: 1,
         },
         {
            problemtype: "Inappropriate default permissions (CWE-276) [NVD Evaluation ]",
            trust: 0.8,
         },
      ],
      sources: [
         {
            db: "JVNDB",
            id: "JVNDB-2020-010865",
         },
         {
            db: "NVD",
            id: "CVE-2020-10049",
         },
      ],
   },
   references: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/references#",
         data: {
            "@container": "@list",
         },
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: [
         {
            trust: 2.2,
            url: "https://cert-portal.siemens.com/productcert/pdf/ssa-251935.pdf",
         },
         {
            trust: 1.4,
            url: "https://nvd.nist.gov/vuln/detail/cve-2020-10049",
         },
         {
            trust: 1.4,
            url: "https://us-cert.cisa.gov/ics/advisories/icsa-20-252-01",
         },
         {
            trust: 0.8,
            url: "https://jvn.jp/vu/jvnvu94568336/",
         },
         {
            trust: 0.6,
            url: "http://www.nsfocus.net/vulndb/50586",
         },
         {
            trust: 0.6,
            url: "https://www.auscert.org.au/bulletins/esb-2020.3078/",
         },
         {
            trust: 0.6,
            url: "https://vigilance.fr/vulnerability/siemens-simatic-rtls-locating-manager-privilege-escalation-33284",
         },
      ],
      sources: [
         {
            db: "CNVD",
            id: "CNVD-2020-51251",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2020-010865",
         },
         {
            db: "NVD",
            id: "CVE-2020-10049",
         },
         {
            db: "CNNVD",
            id: "CNNVD-202009-513",
         },
      ],
   },
   sources: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            db: "CNVD",
            id: "CNVD-2020-51251",
         },
         {
            db: "JVNDB",
            id: "JVNDB-2020-010865",
         },
         {
            db: "NVD",
            id: "CVE-2020-10049",
         },
         {
            db: "CNNVD",
            id: "CNNVD-202009-513",
         },
      ],
   },
   sources_release_date: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            date: "2020-09-09T00:00:00",
            db: "CNVD",
            id: "CNVD-2020-51251",
         },
         {
            date: "2021-02-12T00:00:00",
            db: "JVNDB",
            id: "JVNDB-2020-010865",
         },
         {
            date: "2020-09-09T19:15:18.070000",
            db: "NVD",
            id: "CVE-2020-10049",
         },
         {
            date: "2020-09-08T00:00:00",
            db: "CNNVD",
            id: "CNNVD-202009-513",
         },
      ],
   },
   sources_update_date: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
         data: {
            "@container": "@list",
         },
      },
      data: [
         {
            date: "2020-09-10T00:00:00",
            db: "CNVD",
            id: "CNVD-2020-51251",
         },
         {
            date: "2022-03-11T06:10:00",
            db: "JVNDB",
            id: "JVNDB-2020-010865",
         },
         {
            date: "2020-09-14T19:09:10.297000",
            db: "NVD",
            id: "CVE-2020-10049",
         },
         {
            date: "2020-11-17T00:00:00",
            db: "CNNVD",
            id: "CNNVD-202009-513",
         },
      ],
   },
   threat_type: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: "local",
      sources: [
         {
            db: "CNNVD",
            id: "CNNVD-202009-513",
         },
      ],
      trust: 0.6,
   },
   title: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/title#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: "SIMATIC RTLS Locating Manager  Inappropriate Default Permission Vulnerability",
      sources: [
         {
            db: "JVNDB",
            id: "JVNDB-2020-010865",
         },
      ],
      trust: 0.8,
   },
   type: {
      "@context": {
         "@vocab": "https://www.variotdbs.pl/ref/type#",
         sources: {
            "@container": "@list",
            "@context": {
               "@vocab": "https://www.variotdbs.pl/ref/sources#",
            },
         },
      },
      data: "other",
      sources: [
         {
            db: "CNNVD",
            id: "CNNVD-202009-513",
         },
      ],
      trust: 0.6,
   },
}


Log in or create an account to share your comment.

Security Advisory comment format.

This schema specifies the format of a comment related to a security advisory.

UUIDv4 of the comment
UUIDv4 of the Vulnerability-Lookup instance
When the comment was created originally
When the comment was last updated
Title of the comment
Description of the comment
The identifier of the vulnerability (CVE ID, GHSA-ID, PYSEC ID, etc.).



Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.