var-202010-0572
Vulnerability from variot
Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11. plural NETGEAR The device contains a vulnerability related to insufficient protection of credentials.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects CBR40 prior to 2.5.0.10, RBK752 prior to 3.2.15.25, RBR750 prior to 3.2.15.25, RBS750 prior to 3.2.15.25, RBK852 prior to 3.2.10.11, RBR850 prior to 3.2.10.11, and RBS850 prior to 3.2.10.11
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202010-0572", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.10" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "cbr40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012276" }, { "db": "NVD", "id": "CVE-2020-26906" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-26906" } ] }, "cve": "CVE-2020-26906", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "COMPLETE", "baseScore": 8.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 6.5, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Complete", "baseScore": 8.3, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "CVE-2020-26906", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2020-26906", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-26906", "trust": 1.8, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2020-26906", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202010-337", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2020-26906", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2020-26906" }, { "db": "JVNDB", "id": "JVNDB-2020-012276" }, { "db": "NVD", "id": "CVE-2020-26906" }, { "db": "NVD", "id": "CVE-2020-26906" }, { "db": "CNNVD", "id": "CNNVD-202010-337" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11. plural NETGEAR The device contains a vulnerability related to insufficient protection of credentials.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects CBR40 prior to 2.5.0.10, RBK752 prior to 3.2.15.25, RBR750 prior to 3.2.15.25, RBS750 prior to 3.2.15.25, RBK852 prior to 3.2.10.11, RBR850 prior to 3.2.10.11, and RBS850 prior to 3.2.10.11", "sources": [ { "db": "NVD", "id": "CVE-2020-26906" }, { "db": "JVNDB", "id": "JVNDB-2020-012276" }, { "db": "VULMON", "id": "CVE-2020-26906" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-26906", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2020-012276", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202010-337", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2020-26906", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2020-26906" }, { "db": "JVNDB", "id": "JVNDB-2020-012276" }, { "db": "NVD", "id": "CVE-2020-26906" }, { "db": "CNNVD", "id": "CNNVD-202010-337" } ] }, "id": "VAR-202010-0572", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T13:32:53.823000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Admin\u00a0Credential\u00a0Disclosure\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0048", "trust": 0.8, "url": "https://kb.netgear.com/000062348/security-advisory-for-admin-credential-disclosure-on-some-wifi-systems-psv-2020-0048" }, { "title": "Multiple NETGEAR Repair measures for device security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=131124" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012276" }, { "db": "CNNVD", "id": "CNNVD-202010-337" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "Inadequate protection of credentials (CWE-522) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012276" }, { "db": "NVD", "id": "CVE-2020-26906" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000062348/security-advisory-for-admin-credential-disclosure-on-some-wifi-systems-psv-2020-0048" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-26906" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2020-26906" }, { "db": "JVNDB", "id": "JVNDB-2020-012276" }, { "db": "NVD", "id": "CVE-2020-26906" }, { "db": "CNNVD", "id": "CNNVD-202010-337" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2020-26906" }, { "db": "JVNDB", "id": "JVNDB-2020-012276" }, { "db": "NVD", "id": "CVE-2020-26906" }, { "db": "CNNVD", "id": "CNNVD-202010-337" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-10-09T00:00:00", "db": "VULMON", "id": "CVE-2020-26906" }, { "date": "2021-04-28T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-012276" }, { "date": "2020-10-09T07:15:16.463000", "db": "NVD", "id": "CVE-2020-26906" }, { "date": "2020-10-09T00:00:00", "db": "CNNVD", "id": "CNNVD-202010-337" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-07-21T00:00:00", "db": "VULMON", "id": "CVE-2020-26906" }, { "date": "2021-04-28T07:36:00", "db": "JVNDB", "id": "JVNDB-2020-012276" }, { "date": "2021-07-21T11:39:23.747000", "db": "NVD", "id": "CVE-2020-26906" }, { "date": "2020-10-21T00:00:00", "db": "CNNVD", "id": "CNNVD-202010-337" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202010-337" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Inadequate protection of credentials on devices Vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012276" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202010-337" } ], "trust": 0.6 } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.