var-202011-0845
Vulnerability from variot
A CWE-863: Incorrect Authorization vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause bypass of authentication when overwriting memory using a debugger. PLC Simulator for EcoStruxure Control Expert and PLC Simulator for Unity Pro Is vulnerable to several vulnerabilities: ‥ * Buffer overflow (CWE-120) - CVE-2020-7559 ‥ * Improper checking in exceptional conditions of the program (CWE-754) - CVE-2020-7538 ‥ * Illegal authentication (CWE-863) - CVE-2020-28211 ‥ * Inappropriate restriction of excessive authentication attempts (CWE-307) - CVE-2020-28212 ‥ * Incomplete integrity verification of downloaded code (CWE-494) - CVE-2020-28213The expected impact depends on each vulnerability, but it may be affected as follows. ‥ * By a remote third party Modbus If you send a specially crafted request via EcoStruxure Control Expert of PLC Simulator Is crashed - CVE-2020-7559 , CVE-2020-7538 ‥ * Authentication is bypassed if the memory is overwritten by a local third party using the debugger - CVE-2020-28211 ‥ * By a remote third party Modbus Brute force attack via brute force executes unauthorized commands - CVE-2020-28212 ‥ * By a remote third party Modbus If a specially crafted request is sent via, an unauthorized command will be executed - CVE-2020-28213. Schneider Electric EcoStruxure Control Expert is a universal programming, debugging and operating software for Modicon M340, M580, M580S, Premium, Momentum and Quantum series. An attacker can use this vulnerability to bypass authentication by using a debugger to overwrite the memory
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202011-0845", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ecostruxure control expert", "scope": "eq", "trust": 1.0, "vendor": "schneider electric", "version": "*" }, { "model": "plc simulator", "scope": "eq", "trust": 0.8, "vendor": "schneider electric", "version": "for ecostruxure control expert \u5168\u3066" }, { "model": "plc simulator", "scope": "eq", "trust": 0.8, "vendor": "schneider electric", "version": "for unity pro (\u65e7\u79f0\uff1aecostruxure control expert) \u5168\u3066" }, { "model": "electric ecostruxure control expert", "scope": null, "trust": 0.6, "vendor": "schneider", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-29460" }, { "db": "JVNDB", "id": "JVNDB-2020-009547" }, { "db": "NVD", "id": "CVE-2020-28211" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-28211" } ] }, "cve": "CVE-2020-28211", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 4.6, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 3.9, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 4.6, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 3.9, "id": "CNVD-2021-29460", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA score", "availabilityImpact": "High", "baseScore": 10, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-009547", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Changed", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA score", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2020-009547", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "IPA score", "availabilityImpact": "None", "baseScore": 7.4, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-009547", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Changed", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:N", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA score", "availabilityImpact": "High", "baseScore": 9.1, "baseSeverity": "Critical", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2020-009547", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "IPA score", "availabilityImpact": "High", "baseScore": 8.1, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2020-009547", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "IPA", "id": "JVNDB-2020-009547", "trust": 2.4, "value": "High" }, { "author": "IPA", "id": "JVNDB-2020-009547", "trust": 1.6, "value": "Critical" }, { "author": "NVD", "id": "CVE-2020-28211", "trust": 1.0, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2021-29460", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202011-1681", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-29460" }, { "db": "JVNDB", "id": "JVNDB-2020-009547" }, { "db": "JVNDB", "id": "JVNDB-2020-009547" }, { "db": "JVNDB", "id": "JVNDB-2020-009547" }, { "db": "JVNDB", "id": "JVNDB-2020-009547" }, { "db": "JVNDB", "id": "JVNDB-2020-009547" }, { "db": "NVD", "id": "CVE-2020-28211" }, { "db": "CNNVD", "id": "CNNVD-202011-1681" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A CWE-863: Incorrect Authorization vulnerability exists in PLC Simulator on EcoStruxure\u00aa Control Expert (now Unity Pro) (all versions) that could cause bypass of authentication when overwriting memory using a debugger. PLC Simulator for EcoStruxure Control Expert and PLC Simulator for Unity Pro Is vulnerable to several vulnerabilities: \u2025 * Buffer overflow (CWE-120) - CVE-2020-7559 \u2025 * Improper checking in exceptional conditions of the program (CWE-754) - CVE-2020-7538 \u2025 * Illegal authentication (CWE-863) - CVE-2020-28211 \u2025 * Inappropriate restriction of excessive authentication attempts (CWE-307) - CVE-2020-28212 \u2025 * Incomplete integrity verification of downloaded code (CWE-494) - CVE-2020-28213The expected impact depends on each vulnerability, but it may be affected as follows. \u2025 * By a remote third party Modbus If you send a specially crafted request via EcoStruxure Control Expert of PLC Simulator Is crashed - CVE-2020-7559 , CVE-2020-7538 \u2025 * Authentication is bypassed if the memory is overwritten by a local third party using the debugger - CVE-2020-28211 \u2025 * By a remote third party Modbus Brute force attack via brute force executes unauthorized commands - CVE-2020-28212 \u2025 * By a remote third party Modbus If a specially crafted request is sent via, an unauthorized command will be executed - CVE-2020-28213. Schneider Electric EcoStruxure Control Expert is a universal programming, debugging and operating software for Modicon M340, M580, M580S, Premium, Momentum and Quantum series. An attacker can use this vulnerability to bypass authentication by using a debugger to overwrite the memory", "sources": [ { "db": "NVD", "id": "CVE-2020-28211" }, { "db": "JVNDB", "id": "JVNDB-2020-009547" }, { "db": "CNVD", "id": "CNVD-2021-29460" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-28211", "trust": 3.0 }, { "db": "SCHNEIDER", "id": "SEVD-2020-315-07", "trust": 1.6 }, { "db": "ICS CERT", "id": "ICSA-20-315-03", "trust": 0.8 }, { "db": "JVN", "id": "JVNVU92857198", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2020-009547", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-29460", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202011-1681", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-29460" }, { "db": "JVNDB", "id": "JVNDB-2020-009547" }, { "db": "NVD", "id": "CVE-2020-28211" }, { "db": "CNNVD", "id": "CNNVD-202011-1681" } ] }, "id": "VAR-202011-0845", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-29460" } ], "trust": 1.2287037 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-29460" } ] }, "last_update_date": "2023-12-18T11:57:50.597000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "EcoStruxure Control Expert", "trust": 0.8, "url": "https://www.se.com/ww/en/product-range-download/548-ecostruxure%e2%84%a2-control-expert/?parent-subcategory-id=3950\u0026filter=business-1-industrial-automation-and-control\u0026selected-node-id=12365959203#/software-firmware-tab" }, { "title": "Security Notification - PLC Simulator on EcoStruxure\u0026#8482; Control Expert", "trust": 0.8, "url": "https://www.se.com/ww/en/download/document/sevd-2020-315-07/" }, { "title": "Patch for Schneider Electric EcoStruxure Control Expert incorrect authorization vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/259511" }, { "title": "Schneider Electric EcoStruxure Control Expert Fixes for permissions and access control issues vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=137121" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-29460" }, { "db": "JVNDB", "id": "JVNDB-2020-009547" }, { "db": "CNNVD", "id": "CNNVD-202011-1681" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-863", "trust": 1.8 }, { "problemtype": "CWE-494", "trust": 0.8 }, { "problemtype": "CWE-307", "trust": 0.8 }, { "problemtype": "CWE-120", "trust": 0.8 }, { "problemtype": "CWE-754", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-009547" }, { "db": "NVD", "id": "CVE-2020-28211" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://www.se.com/ww/en/download/document/sevd-2020-315-07" }, { "trust": 1.2, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-28211" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-7559" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-7538" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-28211" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-28212" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-28213" }, { "trust": 0.8, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-315-03" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu92857198/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-29460" }, { "db": "JVNDB", "id": "JVNDB-2020-009547" }, { "db": "NVD", "id": "CVE-2020-28211" }, { "db": "CNNVD", "id": "CNNVD-202011-1681" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-29460" }, { "db": "JVNDB", "id": "JVNDB-2020-009547" }, { "db": "NVD", "id": "CVE-2020-28211" }, { "db": "CNNVD", "id": "CNNVD-202011-1681" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-04-19T00:00:00", "db": "CNVD", "id": "CNVD-2021-29460" }, { "date": "2020-11-12T06:49:50", "db": "JVNDB", "id": "JVNDB-2020-009547" }, { "date": "2020-11-19T22:15:13.410000", "db": "NVD", "id": "CVE-2020-28211" }, { "date": "2020-11-19T00:00:00", "db": "CNNVD", "id": "CNNVD-202011-1681" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-04-25T00:00:00", "db": "CNVD", "id": "CNVD-2021-29460" }, { "date": "2020-11-12T06:49:50", "db": "JVNDB", "id": "JVNDB-2020-009547" }, { "date": "2022-01-31T19:33:27.443000", "db": "NVD", "id": "CVE-2020-28211" }, { "date": "2022-03-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202011-1681" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202011-1681" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Schneider Electric Made PLC Simulator for EcoStruxure Control Expert Multiple vulnerabilities in", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-009547" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "permissions and access control issues", "sources": [ { "db": "CNNVD", "id": "CNNVD-202011-1681" } ], "trust": 0.6 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.