var-202103-1585
Vulnerability from variot
A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12532). Zero Day Initiative To this vulnerability ZDI-CAN-12532 Was numbered.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Solid Edge Viewer. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of PAR files
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202103-1585", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "solid edge", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "se2021" }, { "model": "solid edge", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "se2020" }, { "model": "solid edge", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "se2020" }, { "model": "solid edge", "scope": "eq", "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": "se2021mp4" }, { "model": "solid edge", "scope": "eq", "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": "se2020mp13" }, { "model": "solid edge", "scope": "eq", "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "solid edge viewer", "scope": null, "trust": 0.7, "vendor": "siemens", "version": null } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-274" }, { "db": "JVNDB", "id": "JVNDB-2021-004476" }, { "db": "NVD", "id": "CVE-2021-27380" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "se2020", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:-:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack1:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack10:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack11:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack12:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack2:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack3:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack4:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack5:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack6:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack7:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack8:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack9:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:-:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack1:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack2:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack3:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-27380" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Francis Provencher {PRL}", "sources": [ { "db": "ZDI", "id": "ZDI-21-274" } ], "trust": 0.7 }, "cve": "CVE-2021-27380", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": null, "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULMON", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "CVE-2021-27380", "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "MEDIUM", "trust": 1.9, "userInteractionRequired": null, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "id": "CVE-2021-27380", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-27380", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "ZDI", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "id": "CVE-2021-27380", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 0.7, "userInteraction": "REQUIRED", "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-27380", "trust": 1.8, "value": "High" }, { "author": "ZDI", "id": "CVE-2021-27380", "trust": 0.7, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202103-697", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-27380", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-274" }, { "db": "VULMON", "id": "CVE-2021-27380" }, { "db": "JVNDB", "id": "JVNDB-2021-004476" }, { "db": "CNNVD", "id": "CNNVD-202103-697" }, { "db": "NVD", "id": "CVE-2021-27380" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in Solid Edge SE2020 (All versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12532). Zero Day Initiative To this vulnerability ZDI-CAN-12532 Was numbered.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Solid Edge Viewer. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of PAR files", "sources": [ { "db": "NVD", "id": "CVE-2021-27380" }, { "db": "JVNDB", "id": "JVNDB-2021-004476" }, { "db": "ZDI", "id": "ZDI-21-274" }, { "db": "VULMON", "id": "CVE-2021-27380" } ], "trust": 2.34 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-27380", "trust": 3.2 }, { "db": "ICS CERT", "id": "ICSA-21-103-06", "trust": 2.5 }, { "db": "SIEMENS", "id": "SSA-574442", "trust": 1.7 }, { "db": "SIEMENS", "id": "SSA-715184", "trust": 1.7 }, { "db": "ZDI", "id": "ZDI-21-274", "trust": 1.4 }, { "db": "JVN", "id": "JVNVU93441670", "trust": 0.8 }, { "db": "JVN", "id": "JVNVU96269392", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2021-004476", "trust": 0.8 }, { "db": "ZDI_CAN", "id": "ZDI-CAN-12532", "trust": 0.7 }, { "db": "AUSCERT", "id": "ESB-2021.1244", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2021.0854", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-21-068-09", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202103-697", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-27380", "trust": 0.1 } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-274" }, { "db": "VULMON", "id": "CVE-2021-27380" }, { "db": "JVNDB", "id": "JVNDB-2021-004476" }, { "db": "CNNVD", "id": "CNNVD-202103-697" }, { "db": "NVD", "id": "CVE-2021-27380" } ] }, "id": "VAR-202103-1585", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.19128205 }, "last_update_date": "2022-05-04T06:53:34.594000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-574442 Siemens\u00a0Security\u00a0Advisory", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf" }, { "title": "Siemens has issued an update to correct this vulnerability.", "trust": 0.7, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-068-09" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=1b3f65b08c80e38048cc09f548b68a84" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=eaf7ce45c295beb8a23b24ef0efbaa1c" } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-274" }, { "db": "VULMON", "id": "CVE-2021-27380" }, { "db": "JVNDB", "id": "JVNDB-2021-004476" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [ Other ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004476" }, { "db": "NVD", "id": "CVE-2021-27380" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.1, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-27380" }, { "trust": 1.3, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-068-09" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu93441670/" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu96269392/" }, { "trust": 0.7, "url": "https://www.zerodayinitiative.com/advisories/zdi-21-274/" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2021.1244" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2021.0854" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/787.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://cert-portal.siemens.com/productcert/txt/ssa-574442.txt" } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-274" }, { "db": "VULMON", "id": "CVE-2021-27380" }, { "db": "JVNDB", "id": "JVNDB-2021-004476" }, { "db": "CNNVD", "id": "CNNVD-202103-697" }, { "db": "NVD", "id": "CVE-2021-27380" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "ZDI", "id": "ZDI-21-274" }, { "db": "VULMON", "id": "CVE-2021-27380" }, { "db": "JVNDB", "id": "JVNDB-2021-004476" }, { "db": "CNNVD", "id": "CNNVD-202103-697" }, { "db": "NVD", "id": "CVE-2021-27380" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-11T00:00:00", "db": "ZDI", "id": "ZDI-21-274" }, { "date": "2021-03-15T00:00:00", "db": "VULMON", "id": "CVE-2021-27380" }, { "date": "2021-11-22T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-004476" }, { "date": "2021-03-09T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-697" }, { "date": "2021-03-15T17:15:00", "db": "NVD", "id": "CVE-2021-27380" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-11T00:00:00", "db": "ZDI", "id": "ZDI-21-274" }, { "date": "2021-04-22T00:00:00", "db": "VULMON", "id": "CVE-2021-27380" }, { "date": "2021-11-22T09:03:00", "db": "JVNDB", "id": "JVNDB-2021-004476" }, { "date": "2021-06-09T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-697" }, { "date": "2021-12-10T21:32:00", "db": "NVD", "id": "CVE-2021-27380" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-697" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Solid\u00a0Edge\u00a0 Out-of-bounds Vulnerability in Microsoft", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004476" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-697" } ], "trust": 0.6 } }
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.