Vulnerability from variot - Updated: 2023-12-18 11:45A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS domain name record decompression functionality does not properly validate the pointer offset values. The parsing of malformed responses could result in a read access past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition. SIMOTICS CONNECT 400 is a connector and sensor box installed on a low-voltage motor and provides analysis data for the MindSphere application SIDRIVE IQ Fleet.
Siemens SIMOTICS CONNECT 400 has a denial of service vulnerability. Attackers can use vulnerabilities to cause denial of service. Pillow is a Python-based image processing library. There is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202104-1824",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "nucleus source code",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "simotics connect 400",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "0.5.0.0"
},
{
"model": "nucleus net",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "nucleus readystart v3",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2017.02.3"
},
{
"model": "nucleus readystart v4",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "4.1.0"
},
{
"model": "simotics connect",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "400\u003cv0.5.0.0"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-28705"
},
{
"db": "NVD",
"id": "CVE-2020-27738"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simotics_connect_400_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "0.5.0.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simotics_connect_400:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:nucleus_net:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:nucleus_source_code:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:nucleus_readystart_v3:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2017.02.3",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:nucleus_readystart_v4:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "4.1.0",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-27738"
}
]
},
"cve": "CVE-2020-27738",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 5.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"impactScore": 4.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:P",
"version": "2.0"
},
{
"accessComplexity": "HIGH",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 6.1,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 4.9,
"id": "CNVD-2021-28705",
"impactScore": 7.8,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:H/Au:N/C:P/I:N/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULMON",
"availabilityImpact": "PARTIAL",
"baseScore": 6.4,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CVE-2020-27738",
"impactScore": 4.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "MEDIUM",
"trust": 0.1,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.2,
"impactScore": 5.2,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"author": "productcert@siemens.com",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"exploitabilityScore": 2.2,
"impactScore": 4.2,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2020-27738",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "productcert@siemens.com",
"id": "CVE-2020-27738",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "CNVD",
"id": "CNVD-2021-28705",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202104-975",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202104-934",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2020-27738",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-28705"
},
{
"db": "VULMON",
"id": "CVE-2020-27738"
},
{
"db": "NVD",
"id": "CVE-2020-27738"
},
{
"db": "NVD",
"id": "CVE-2020-27738"
},
{
"db": "CNNVD",
"id": "CNNVD-202104-975"
},
{
"db": "CNNVD",
"id": "CNNVD-202104-934"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.20), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.3), Nucleus ReadyStart V4 (All versions \u003c V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions \u003c V0.5.0.0), TALON TC Compact (BACnet) (All versions \u003c V3.5.5), TALON TC Modular (BACnet) (All versions \u003c V3.5.5). The DNS domain name record decompression functionality does not properly validate the pointer offset values. The parsing of malformed responses could result in a read access past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition. SIMOTICS CONNECT 400 is a connector and sensor box installed on a low-voltage motor and provides analysis data for the MindSphere application SIDRIVE IQ Fleet. \n\r\n\r\nSiemens SIMOTICS CONNECT 400 has a denial of service vulnerability. Attackers can use vulnerabilities to cause denial of service. Pillow is a Python-based image processing library. \nThere is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-27738"
},
{
"db": "CNVD",
"id": "CNVD-2021-28705"
},
{
"db": "CNNVD",
"id": "CNNVD-202104-975"
},
{
"db": "VULMON",
"id": "CVE-2020-27738"
}
],
"trust": 2.07
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "SIEMENS",
"id": "SSA-669158",
"trust": 2.3
},
{
"db": "NVD",
"id": "CVE-2020-27738",
"trust": 2.3
},
{
"db": "SIEMENS",
"id": "SSA-705111",
"trust": 1.7
},
{
"db": "SIEMENS",
"id": "SSA-180579",
"trust": 1.0
},
{
"db": "CNVD",
"id": "CNVD-2021-28705",
"trust": 0.6
},
{
"db": "CS-HELP",
"id": "SB2021041363",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202104-975",
"trust": 0.6
},
{
"db": "ICS CERT",
"id": "ICSA-21-103-13",
"trust": 0.6
},
{
"db": "CS-HELP",
"id": "SB2021041407",
"trust": 0.6
},
{
"db": "CS-HELP",
"id": "SB2021041515",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202104-934",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2020-27738",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-28705"
},
{
"db": "VULMON",
"id": "CVE-2020-27738"
},
{
"db": "NVD",
"id": "CVE-2020-27738"
},
{
"db": "CNNVD",
"id": "CNNVD-202104-975"
},
{
"db": "CNNVD",
"id": "CNNVD-202104-934"
}
]
},
"id": "VAR-202104-1824",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-28705"
}
],
"trust": 1.1595598933333333
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-28705"
}
]
},
"last_update_date": "2023-12-18T11:45:06.473000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Siemens SIMOTICS CONNECT 400 Denial of Service Vulnerability (CNVD-2021-28705)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/258576"
},
{
"title": "Siemens Security Advisories: Siemens Security Advisory",
"trust": 0.1,
"url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=53e7f522de1910b1af8f6f92fe53b3b1"
},
{
"title": "Siemens Security Advisories: Siemens Security Advisory",
"trust": 0.1,
"url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=8f932b97a970d1020015c1a82a730e96"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-28705"
},
{
"db": "VULMON",
"id": "CVE-2020-27738"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-119",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-27738"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.3,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf"
},
{
"trust": 1.7,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf"
},
{
"trust": 1.0,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
},
{
"trust": 0.6,
"url": "https://www.cybersecurity-help.cz/vdb/sb2021041363"
},
{
"trust": 0.6,
"url": "https://www.cybersecurity-help.cz/vdb/sb2021041515"
},
{
"trust": 0.6,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-27738"
},
{
"trust": 0.6,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-13"
},
{
"trust": 0.6,
"url": "https://www.cybersecurity-help.cz/vdb/sb2021041407"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/119.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-669158.txt"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-28705"
},
{
"db": "VULMON",
"id": "CVE-2020-27738"
},
{
"db": "NVD",
"id": "CVE-2020-27738"
},
{
"db": "CNNVD",
"id": "CNNVD-202104-975"
},
{
"db": "CNNVD",
"id": "CNNVD-202104-934"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2021-28705"
},
{
"db": "VULMON",
"id": "CVE-2020-27738"
},
{
"db": "NVD",
"id": "CVE-2020-27738"
},
{
"db": "CNNVD",
"id": "CNNVD-202104-975"
},
{
"db": "CNNVD",
"id": "CNNVD-202104-934"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-04-15T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-28705"
},
{
"date": "2021-04-22T00:00:00",
"db": "VULMON",
"id": "CVE-2020-27738"
},
{
"date": "2021-04-22T21:15:09.313000",
"db": "NVD",
"id": "CVE-2020-27738"
},
{
"date": "2021-04-13T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202104-975"
},
{
"date": "2021-04-13T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202104-934"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-04-15T00:00:00",
"db": "CNVD",
"id": "CNVD-2021-28705"
},
{
"date": "2021-04-30T00:00:00",
"db": "VULMON",
"id": "CVE-2020-27738"
},
{
"date": "2023-08-08T10:15:12.050000",
"db": "NVD",
"id": "CVE-2020-27738"
},
{
"date": "2021-04-14T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202104-975"
},
{
"date": "2022-01-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202104-934"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202104-934"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens SIMOTICS CONNECT 400 Denial of Service Vulnerability (CNVD-2021-28705)",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2021-28705"
}
],
"trust": 0.6
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "other",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202104-975"
}
],
"trust": 0.6
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.