An issue was discovered on Enphase Envoy R3.x and D4.x devices. There are hardcoded web-panel login passwords for the installer and Enphase accounts. The passwords for these accounts are hardcoded values derived from the MD5 hash of the username and serial number mixed with some static strings. The serial number can be retrieved by an unauthenticated user at /info.xml. These passwords can be easily calculated by an attacker; users are unable to change these passwords. Enphase Envoy Is vulnerable to the use of hard-coded credentials.Information may be obtained. Enphase Energy Envoy is a gateway device used to connect smart home devices from Enphase Energy in the United States.

Enphase Energy Envoy has a trust management vulnerability

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202106-0266",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "envoy",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "enphase",
        "version": "r3.0"
      },
      {
        "model": "envoy",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "enphase",
        "version": "d4.0"
      },
      {
        "model": "envoy",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "enphase energy",
        "version": "r3.x"
      },
      {
        "model": "envoy",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "enphase energy",
        "version": null
      },
      {
        "model": "envoy",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "enphase energy",
        "version": "d4.x"
      },
      {
        "model": "energy envoy r3.*",
        "scope": null,
        "trust": 0.6,
        "vendor": "enphase",
        "version": null
      },
      {
        "model": "energy envoy d4.*",
        "scope": null,
        "trust": 0.6,
        "vendor": "enphase",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-45765"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-008348"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-25752"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:enphase:envoy_firmware:d4.0:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:enphase:envoy_firmware:r3.0:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:enphase:envoy:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-25752"
      }
    ]
  },
  "cve": "CVE-2020-25752",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 5.0,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "CVE-2020-25752",
            "impactScore": null,
            "integrityImpact": "None",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2021-45765",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 3.9,
            "impactScore": 1.4,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 5.3,
            "baseSeverity": "Medium",
            "confidentialityImpact": "Low",
            "exploitabilityScore": null,
            "id": "CVE-2020-25752",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2020-25752",
            "trust": 1.8,
            "value": "MEDIUM"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2021-45765",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202106-1345",
            "trust": 0.6,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-45765"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-008348"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-25752"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202106-1345"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Enphase Envoy R3.x and D4.x devices. There are hardcoded web-panel login passwords for the installer and Enphase accounts. The passwords for these accounts are hardcoded values derived from the MD5 hash of the username and serial number mixed with some static strings. The serial number can be retrieved by an unauthenticated user at /info.xml. These passwords can be easily calculated by an attacker; users are unable to change these passwords. Enphase Envoy Is vulnerable to the use of hard-coded credentials.Information may be obtained. Enphase Energy Envoy is a gateway device used to connect smart home devices from Enphase Energy in the United States. \n\r\n\r\nEnphase Energy Envoy has a trust management vulnerability",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-25752"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-008348"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-45765"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-25752",
        "trust": 3.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-008348",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-45765",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202106-1345",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-45765"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-008348"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-25752"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202106-1345"
      }
    ]
  },
  "id": "VAR-202106-0266",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-45765"
      }
    ],
    "trust": 1.6
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-45765"
      }
    ]
  },
  "last_update_date": "2023-12-18T12:35:00.606000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Communication",
        "trust": 0.8,
        "url": "https://enphase.com/en-us/products-and-services/envoy-and-combiner"
      },
      {
        "title": "Patch for Enphase Energy Envoy trust management issue vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/276106"
      },
      {
        "title": "Enphase Envoy Repair measures for trust management problem vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=155301"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-45765"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-008348"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202106-1345"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-798",
        "trust": 1.0
      },
      {
        "problemtype": "Using hardcoded credentials (CWE-798) [NVD Evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-008348"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-25752"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://medium.com/stage-2-security/can-solar-controllers-be-used-to-generate-fake-clean-energy-credits-4a7322e7661a"
      },
      {
        "trust": 1.6,
        "url": "https://enphase.com/en-us/products-and-services/envoy-and-combiner"
      },
      {
        "trust": 1.6,
        "url": "https://stage2sec.com"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-25752"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-45765"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-008348"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-25752"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202106-1345"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-45765"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-008348"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-25752"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202106-1345"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-06-29T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-45765"
      },
      {
        "date": "2022-03-14T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-008348"
      },
      {
        "date": "2021-06-16T19:15:17.470000",
        "db": "NVD",
        "id": "CVE-2020-25752"
      },
      {
        "date": "2021-06-16T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202106-1345"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-06-29T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-45765"
      },
      {
        "date": "2022-03-14T07:16:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-008348"
      },
      {
        "date": "2021-06-24T12:08:21.947000",
        "db": "NVD",
        "id": "CVE-2020-25752"
      },
      {
        "date": "2021-06-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202106-1345"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202106-1345"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Enphase\u00a0Envoy\u00a0 Vulnerability in Using Hard Coded Credentials",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-008348"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "trust management problem",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202106-1345"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…