var-202109-0404
Vulnerability from variot

A vulnerability has been identified in APOGEE MBC (PPC) (P2 Ethernet) (All versions >= V2.6.3), APOGEE MEC (PPC) (P2 Ethernet) (All versions >= V2.6.3), APOGEE PXC Compact (BACnet) (All versions < V3.5.3), APOGEE PXC Compact (P2 Ethernet) (All versions >= V2.8), APOGEE PXC Modular (BACnet) (All versions < V3.5.3), APOGEE PXC Modular (P2 Ethernet) (All versions >= V2.8), TALON TC Compact (BACnet) (All versions < V3.5.3), TALON TC Modular (BACnet) (All versions < V3.5.3). The web server of affected devices lacks proper bounds checking when parsing the Host parameter in HTTP requests, which could lead to a buffer overflow. An unauthenticated remote attacker could exploit this vulnerability to execute arbitrary code on the device with root privileges. Multiple Siemens products contain a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Siemens APOGEE MBC is a modular building controller of Siemens (Siemens), Germany.

Many Siemens APOGEE MBC products have buffer overflow vulnerabilities. Pillow is a Python-based image processing library. There is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202109-0404",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "apogee pxc modular",
        "scope": null,
        "trust": 1.6,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "apogee pxc compact \\",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.8"
      },
      {
        "model": "talon tc modular \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.5.3"
      },
      {
        "model": "apogee pxc bacnet automation controller",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.5.3"
      },
      {
        "model": "apogee pxc modular \\",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.8"
      },
      {
        "model": "apogee mbc \\ \\",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.6.3"
      },
      {
        "model": "apogee pxc modular \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.5.3"
      },
      {
        "model": "talon tc compact \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.5.3"
      },
      {
        "model": "apogee mec \\ \\",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.6.3"
      },
      {
        "model": "apogee mbc",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "talon tc modular",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "talon tc compact",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "apogee pxc bacnet automation \u30b3\u30f3\u30c8\u30ed\u30fc\u30e9",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "apogee pxc compact",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "apogee mec",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "apogee mbc",
        "scope": "gte",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v2.6.3"
      },
      {
        "model": "apogee mec",
        "scope": "gte",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v2.6.3"
      },
      {
        "model": "apogee pxc compact",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v3.5.3"
      },
      {
        "model": "apogee pxc compact",
        "scope": "gte",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v2.8"
      },
      {
        "model": "apogee pxc modular",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v3.5.3"
      },
      {
        "model": "apogee pxc modular",
        "scope": "gte",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v2.8"
      },
      {
        "model": "talon tc compact",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v3.5.3"
      },
      {
        "model": "talon tc modular",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v3.5.3"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-71447"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-012332"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-27391"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:apogee_mbc_\\(ppc\\)_\\(p2_ethernet\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "2.6.3",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:apogee_mbc_\\(ppc\\)_\\(p2_ethernet\\):*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:apogee_mec_\\(ppc\\)_\\(p2_ethernet\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "2.6.3",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:apogee_mec_\\(ppc\\)_\\(p2_ethernet\\):*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:apogee_pxc_bacnet_automation_controller_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.5.3",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:apogee_pxc_bacnet_automation_controller:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:apogee_pxc_compact_\\(p2_ethernet\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "2.8",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:apogee_pxc_compact_\\(p2_ethernet\\):*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:apogee_pxc_modular_\\(bacnet\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.5.3",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:apogee_pxc_modular_\\(bacnet\\):*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:apogee_pxc_modular_\\(p2_ethernet\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "2.8",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:apogee_pxc_modular_\\(p2_ethernet\\):*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:talon_tc_compact_\\(bacnet\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.5.3",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:talon_tc_compact_\\(bacnet\\):*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:talon_tc_modular_\\(bacnet\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.5.3",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:talon_tc_modular_\\(bacnet\\):*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-27391"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Paul Noalhyt and David Doggett from Red Balloon Security reported this vulnerability to Siemens.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202109-940"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2021-27391",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "HIGH",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Complete",
            "baseScore": 10.0,
            "confidentialityImpact": "Complete",
            "exploitabilityScore": null,
            "id": "CVE-2021-27391",
            "impactScore": null,
            "integrityImpact": "Complete",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.9,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2021-71447",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2021-27391",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2021-27391",
            "trust": 1.8,
            "value": "CRITICAL"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2021-71447",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202104-975",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202109-940",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULMON",
            "id": "CVE-2021-27391",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-71447"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-27391"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-012332"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-27391"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202109-940"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in APOGEE MBC (PPC) (P2 Ethernet) (All versions \u003e= V2.6.3), APOGEE MEC (PPC) (P2 Ethernet) (All versions \u003e= V2.6.3), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.3), APOGEE PXC Compact (P2 Ethernet) (All versions \u003e= V2.8), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.3), APOGEE PXC Modular (P2 Ethernet) (All versions \u003e= V2.8), TALON TC Compact (BACnet) (All versions \u003c V3.5.3), TALON TC Modular (BACnet) (All versions \u003c V3.5.3). The web server of affected devices lacks proper bounds checking when parsing the Host parameter in HTTP requests, which could lead to a buffer overflow. An unauthenticated remote attacker could exploit this vulnerability to execute arbitrary code on the device with root privileges. Multiple Siemens products contain a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Siemens APOGEE MBC is a modular building controller of Siemens (Siemens), Germany. \n\r\n\r\nMany Siemens APOGEE MBC products have buffer overflow vulnerabilities. Pillow is a Python-based image processing library. \nThere is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-27391"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-012332"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-71447"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-27391"
      }
    ],
    "trust": 2.79
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2021-27391",
        "trust": 3.9
      },
      {
        "db": "SIEMENS",
        "id": "SSA-944498",
        "trust": 2.3
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-21-257-07",
        "trust": 1.4
      },
      {
        "db": "JVN",
        "id": "JVNVU96712416",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-012332",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-71447",
        "trust": 0.6
      },
      {
        "db": "CS-HELP",
        "id": "SB2021041363",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2021.3107",
        "trust": 0.6
      },
      {
        "db": "CS-HELP",
        "id": "SB2021091515",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202109-940",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-27391",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-71447"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-27391"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-012332"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-27391"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202109-940"
      }
    ]
  },
  "id": "VAR-202109-0404",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-71447"
      }
    ],
    "trust": 1.2646825571428573
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-71447"
      }
    ]
  },
  "last_update_date": "2023-12-18T11:12:01.127000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-944498",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-944498.pdf"
      },
      {
        "title": "Patch for Buffer overflow vulnerabilities in many Siemens APOGEE MBC products",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/291051"
      },
      {
        "title": "Siemens APOGEE MBC Buffer error vulnerability fix",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=162915"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-71447"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-012332"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202109-940"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-120",
        "trust": 1.0
      },
      {
        "problemtype": "Classic buffer overflow (CWE-120) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-012332"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-27391"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.3,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-944498.pdf"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-27391"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu96712416/"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-257-07"
      },
      {
        "trust": 0.6,
        "url": "https://www.cybersecurity-help.cz/vdb/sb2021041363"
      },
      {
        "trust": 0.6,
        "url": "https://www.cybersecurity-help.cz/vdb/sb2021091515"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-257-07"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2021.3107"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/120.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-71447"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-27391"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-012332"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-27391"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202109-940"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-71447"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-27391"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-012332"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-27391"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202109-940"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-09-16T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-71447"
      },
      {
        "date": "2021-09-14T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-27391"
      },
      {
        "date": "2022-08-30T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-012332"
      },
      {
        "date": "2021-09-14T11:15:23.913000",
        "db": "NVD",
        "id": "CVE-2021-27391"
      },
      {
        "date": "2021-04-13T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      },
      {
        "date": "2021-09-14T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202109-940"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-09-16T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-71447"
      },
      {
        "date": "2021-09-28T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-27391"
      },
      {
        "date": "2022-08-30T02:02:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-012332"
      },
      {
        "date": "2021-09-28T16:24:02.287000",
        "db": "NVD",
        "id": "CVE-2021-27391"
      },
      {
        "date": "2021-04-14T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      },
      {
        "date": "2022-07-01T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202109-940"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202109-940"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Classic buffer overflow vulnerability in multiple Siemens products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-012332"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.