VAR-202109-0544

Vulnerability from variot - Updated: 2023-12-18 11:10

A vulnerability has been identified in Simcenter STAR-CCM+ Viewer (All versions < V2021.2.1). The starview+.exe application lacks proper validation of user-supplied data when parsing scene files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13700). Zero Day Initiative To this vulnerability ZDI-CAN-13700 Was numbering.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of SCE files. Pillow is a Python-based image processing library. There is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202109-0544",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "simcenter star-ccm\\+",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2021.2.1"
      },
      {
        "model": "simcenter star-ccm+ viewer",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "simcenter star-ccm+ viewer",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": "simcenter star-ccm+ 2021/2/1  before that"
      },
      {
        "model": "simcenter star-ccm+",
        "scope": null,
        "trust": 0.7,
        "vendor": "siemens",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-1074"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-011721"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-25665"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simcenter_star-ccm\\+:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "2021.2.1",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-25665"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Francis Provencher {PRL}",
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-1074"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202109-950"
      }
    ],
    "trust": 1.3
  },
  "cve": "CVE-2021-25665",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": true,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Medium",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Partial",
            "baseScore": 6.8,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "CVE-2021-25665",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.9,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Local",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2021-25665",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "Required",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "ZDI",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "id": "CVE-2021-25665",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 0.7,
            "userInteraction": "REQUIRED",
            "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2021-25665",
            "trust": 1.8,
            "value": "HIGH"
          },
          {
            "author": "ZDI",
            "id": "CVE-2021-25665",
            "trust": 0.7,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202104-975",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202109-950",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2021-25665",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-1074"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-25665"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-011721"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-25665"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202109-950"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in Simcenter STAR-CCM+ Viewer (All versions \u003c V2021.2.1). The starview+.exe application lacks proper validation of user-supplied data when parsing scene files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13700). Zero Day Initiative To this vulnerability ZDI-CAN-13700 Was numbering.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of SCE files. Pillow is a Python-based image processing library. \nThere is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-25665"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-011721"
      },
      {
        "db": "ZDI",
        "id": "ZDI-21-1074"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-25665"
      }
    ],
    "trust": 2.88
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2021-25665",
        "trust": 4.0
      },
      {
        "db": "ZDI",
        "id": "ZDI-21-1074",
        "trust": 3.2
      },
      {
        "db": "SIEMENS",
        "id": "SSA-109294",
        "trust": 1.7
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-21-257-05",
        "trust": 1.4
      },
      {
        "db": "JVN",
        "id": "JVNVU96712416",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-011721",
        "trust": 0.8
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-13700",
        "trust": 0.7
      },
      {
        "db": "CS-HELP",
        "id": "SB2021041363",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975",
        "trust": 0.6
      },
      {
        "db": "CS-HELP",
        "id": "SB2021091513",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2021.3097",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202109-950",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-25665",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-1074"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-25665"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-011721"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-25665"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202109-950"
      }
    ]
  },
  "id": "VAR-202109-0544",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 1.0
  },
  "last_update_date": "2023-12-18T11:10:50.189000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-109294",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-109294.pdf"
      },
      {
        "title": "Siemens has issued an update to correct this vulnerability.",
        "trust": 0.7,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-257-05"
      },
      {
        "title": "Simcenter STAR-CCM+ Viewer Buffer error vulnerability fix",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=162485"
      },
      {
        "title": "Siemens Security Advisories: Siemens Security Advisory",
        "trust": 0.1,
        "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=eacbd403efe110a581b92ebe3b40bdaa"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-1074"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-25665"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-011721"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202109-950"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-011721"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-25665"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.2,
        "url": "https://www.zerodayinitiative.com/advisories/zdi-21-1074/"
      },
      {
        "trust": 1.7,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-109294.pdf"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-25665"
      },
      {
        "trust": 1.3,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-257-05"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu96712416/index.html"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-257-05"
      },
      {
        "trust": 0.6,
        "url": "https://www.cybersecurity-help.cz/vdb/sb2021041363"
      },
      {
        "trust": 0.6,
        "url": "https://www.cybersecurity-help.cz/vdb/sb2021091513"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2021.3097"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/787.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://cert-portal.siemens.com/productcert/txt/ssa-109294.txt"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-1074"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-25665"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-011721"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-25665"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202109-950"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "ZDI",
        "id": "ZDI-21-1074"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-25665"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-011721"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-25665"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202109-950"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-09-15T00:00:00",
        "db": "ZDI",
        "id": "ZDI-21-1074"
      },
      {
        "date": "2021-09-14T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-25665"
      },
      {
        "date": "2022-08-09T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-011721"
      },
      {
        "date": "2021-09-14T11:15:22.023000",
        "db": "NVD",
        "id": "CVE-2021-25665"
      },
      {
        "date": "2021-04-13T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      },
      {
        "date": "2021-09-14T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202109-950"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-09-15T00:00:00",
        "db": "ZDI",
        "id": "ZDI-21-1074"
      },
      {
        "date": "2021-09-23T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-25665"
      },
      {
        "date": "2022-08-09T06:52:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-011721"
      },
      {
        "date": "2021-09-23T17:00:46.317000",
        "db": "NVD",
        "id": "CVE-2021-25665"
      },
      {
        "date": "2021-04-14T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      },
      {
        "date": "2021-09-24T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202109-950"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202109-950"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Simcenter\u00a0STAR-CCM+\u00a0Viewer\u00a0 Out-of-bounds write vulnerability in",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-011721"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…