var-202112-2276
Vulnerability from variot
Certain NETGEAR devices are affected by stored XSS. This affects R7000 before 1.0.11.110, R7900 before 1.0.4.30, R8000 before 1.0.4.62, RAX200 before 1.0.3.106, R7000P before 1.3.3.140, RAX80 before 1.0.3.106, R6900P before 1.3.3.140, and RAX75 before 1.0.3.106. plural NETGEAR A cross-site scripting vulnerability exists in the device.Information may be obtained and information may be tampered with. This affects R7000 prior to 1.0.11.110, R7900 prior to 1.0.4.30, R8000 prior to 1.0.4.62, RAX200 prior to 1.0.3.106, R7000P prior to 1.3.3.140, RAX80 prior to 1.0.3.106, R6900P prior to 1.3.3.140, and RAX75 prior to 1.0.3.106
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2276", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "r7000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.11.110" }, { "model": "r8000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.62" }, { "model": "rax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.106" }, { "model": "rax75", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.106" }, { "model": "r6900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.3.140" }, { "model": "rax200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.106" }, { "model": "r7900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.30" }, { "model": "r7000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.3.140" }, { "model": "r8000", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r6900p", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax80", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7900", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7000p", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax200", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7000", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax75", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017024" }, { "db": "NVD", "id": "CVE-2021-45673" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.11.110", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.30", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.62", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.3.140", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.3.140", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45673" } ] }, "cve": "CVE-2021-45673", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 3.5, "confidentialityImpact": "NONE", "exploitabilityScore": 6.8, "impactScore": 2.9, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "LOW", "trust": 1.0, "userInteractionRequired": true, "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Medium", "accessVector": "Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "None", "baseScore": 3.5, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2021-45673", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 5.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 2.3, "impactScore": 2.7, "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "CHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 1.7, "impactScore": 2.7, "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "CHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 5.4, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "CVE-2021-45673", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "Low", "scope": "Changed", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45673", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45673", "trust": 1.0, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202112-2466", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45673", "trust": 0.1, "value": "LOW" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45673" }, { "db": "JVNDB", "id": "JVNDB-2021-017024" }, { "db": "NVD", "id": "CVE-2021-45673" }, { "db": "NVD", "id": "CVE-2021-45673" }, { "db": "CNNVD", "id": "CNNVD-202112-2466" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by stored XSS. This affects R7000 before 1.0.11.110, R7900 before 1.0.4.30, R8000 before 1.0.4.62, RAX200 before 1.0.3.106, R7000P before 1.3.3.140, RAX80 before 1.0.3.106, R6900P before 1.3.3.140, and RAX75 before 1.0.3.106. plural NETGEAR A cross-site scripting vulnerability exists in the device.Information may be obtained and information may be tampered with. This affects R7000 prior to 1.0.11.110, R7900 prior to 1.0.4.30, R8000 prior to 1.0.4.62, RAX200 prior to 1.0.3.106, R7000P prior to 1.3.3.140, RAX80 prior to 1.0.3.106, R6900P prior to 1.3.3.140, and RAX75 prior to 1.0.3.106", "sources": [ { "db": "NVD", "id": "CVE-2021-45673" }, { "db": "JVNDB", "id": "JVNDB-2021-017024" }, { "db": "VULMON", "id": "CVE-2021-45673" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45673", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017024", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2466", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45673", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45673" }, { "db": "JVNDB", "id": "JVNDB-2021-017024" }, { "db": "NVD", "id": "CVE-2021-45673" }, { "db": "CNNVD", "id": "CNNVD-202112-2466" } ] }, "id": "VAR-202112-2276", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.34626460400000003 }, "last_update_date": "2023-12-18T12:55:16.768000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Stored\u00a0Cross\u00a0Site\u00a0Scripting\u00a0on\u00a0Some\u00a0Routers,\u00a0PSV-2020-0003", "trust": 0.8, "url": "https://kb.netgear.com/000064456/security-advisory-for-stored-cross-site-scripting-on-some-routers-psv-2020-0003" }, { "title": "Netgear NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177025" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017024" }, { "db": "CNNVD", "id": "CNNVD-202112-2466" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-79", "trust": 1.0 }, { "problemtype": "Cross-site scripting (CWE-79) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017024" }, { "db": "NVD", "id": "CVE-2021-45673" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064456/security-advisory-for-stored-cross-site-scripting-on-some-routers-psv-2020-0003" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45673" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/79.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45673" }, { "db": "JVNDB", "id": "JVNDB-2021-017024" }, { "db": "NVD", "id": "CVE-2021-45673" }, { "db": "CNNVD", "id": "CNNVD-202112-2466" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45673" }, { "db": "JVNDB", "id": "JVNDB-2021-017024" }, { "db": "NVD", "id": "CVE-2021-45673" }, { "db": "CNNVD", "id": "CNNVD-202112-2466" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45673" }, { "date": "2022-12-27T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017024" }, { "date": "2021-12-26T01:15:21.150000", "db": "NVD", "id": "CVE-2021-45673" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2466" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-05T00:00:00", "db": "VULMON", "id": "CVE-2021-45673" }, { "date": "2022-12-27T08:59:00", "db": "JVNDB", "id": "JVNDB-2021-017024" }, { "date": "2022-01-05T15:06:22.840000", "db": "NVD", "id": "CVE-2021-45673" }, { "date": "2022-01-06T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2466" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2466" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Cross-site scripting vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017024" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "XSS", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2466" } ], "trust": 0.6 } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.