VAR-202112-2396
Vulnerability from variot - Updated: 2023-12-18 13:27Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.58, R7500v2 before 1.0.3.48, R7800 before 1.0.2.68, R8900 before 1.0.5.2, R9000 before 1.0.5.2, RAX120 before 1.0.1.108, and XR700 before 1.0.1.20. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects D7800 prior to 1.0.1.58, R7500v2 prior to 1.0.3.48, R7800 prior to 1.0.2.68, R8900 prior to 1.0.5.2, R9000 prior to 1.0.5.2, RAX120 prior to 1.0.1.108, and XR700 prior to 1.0.1.20
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202112-2396",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "d7800",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.1.58"
},
{
"model": "rax120",
"scope": "lte",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.1.108"
},
{
"model": "r7800",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.2.68"
},
{
"model": "r8900",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.5.2"
},
{
"model": "xr700",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.1.20"
},
{
"model": "r7500v2",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.3.48"
},
{
"model": "r9000",
"scope": "lt",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.5.2"
},
{
"model": "r7800",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "r8900",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "r7500v2",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "d7800",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "rax120",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "xr700",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "r9000",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-016928"
},
{
"db": "NVD",
"id": "CVE-2021-45552"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.0.1.58",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:netgear:r7500v2_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.0.3.48",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:netgear:r7500v2:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.0.2.68",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.0.5.2",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.0.5.2",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:netgear:rax120_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "1.0.1.108",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:netgear:rax120:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:netgear:xr700_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.0.1.20",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:netgear:xr700:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2021-45552"
}
]
},
"cve": "CVE-2021-45552",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 6.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 6.5,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2021-45552",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.9,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "cve@mitre.org",
"availabilityImpact": "LOW",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 0.8,
"impactScore": 5.5,
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:L",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.2,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2021-45552",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "High",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2021-45552",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "cve@mitre.org",
"id": "CVE-2021-45552",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202112-2366",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2021-45552",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2021-45552"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-016928"
},
{
"db": "NVD",
"id": "CVE-2021-45552"
},
{
"db": "NVD",
"id": "CVE-2021-45552"
},
{
"db": "CNNVD",
"id": "CNNVD-202112-2366"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.58, R7500v2 before 1.0.3.48, R7800 before 1.0.2.68, R8900 before 1.0.5.2, R9000 before 1.0.5.2, RAX120 before 1.0.1.108, and XR700 before 1.0.1.20. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects D7800 prior to 1.0.1.58, R7500v2 prior to 1.0.3.48, R7800 prior to 1.0.2.68, R8900 prior to 1.0.5.2, R9000 prior to 1.0.5.2, RAX120 prior to 1.0.1.108, and XR700 prior to 1.0.1.20",
"sources": [
{
"db": "NVD",
"id": "CVE-2021-45552"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-016928"
},
{
"db": "VULMON",
"id": "CVE-2021-45552"
}
],
"trust": 1.71
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2021-45552",
"trust": 3.3
},
{
"db": "JVNDB",
"id": "JVNDB-2021-016928",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202112-2366",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2021-45552",
"trust": 0.1
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2021-45552"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-016928"
},
{
"db": "NVD",
"id": "CVE-2021-45552"
},
{
"db": "CNNVD",
"id": "CNNVD-202112-2366"
}
]
},
"id": "VAR-202112-2396",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.39687575142857145
},
"last_update_date": "2023-12-18T13:27:28.849000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0Routers,\u00a0PSV-2019-0199",
"trust": 0.8,
"url": "https://kb.netgear.com/000064071/security-advisory-for-post-authentication-command-injection-on-some-routers-psv-2019-0199"
},
{
"title": "Netgear NETGEAR Fixes for command injection vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177073"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-016928"
},
{
"db": "CNNVD",
"id": "CNNVD-202112-2366"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-77",
"trust": 1.0
},
{
"problemtype": "Command injection (CWE-77) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-016928"
},
{
"db": "NVD",
"id": "CVE-2021-45552"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "https://kb.netgear.com/000064071/security-advisory-for-post-authentication-command-injection-on-some-routers-psv-2019-0199"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2021-45552"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/77.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2021-45552"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-016928"
},
{
"db": "NVD",
"id": "CVE-2021-45552"
},
{
"db": "CNNVD",
"id": "CNNVD-202112-2366"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULMON",
"id": "CVE-2021-45552"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-016928"
},
{
"db": "NVD",
"id": "CVE-2021-45552"
},
{
"db": "CNNVD",
"id": "CNNVD-202112-2366"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-12-26T00:00:00",
"db": "VULMON",
"id": "CVE-2021-45552"
},
{
"date": "2022-12-27T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2021-016928"
},
{
"date": "2021-12-26T01:15:15.460000",
"db": "NVD",
"id": "CVE-2021-45552"
},
{
"date": "2021-12-26T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202112-2366"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-01-04T00:00:00",
"db": "VULMON",
"id": "CVE-2021-45552"
},
{
"date": "2022-12-27T03:14:00",
"db": "JVNDB",
"id": "JVNDB-2021-016928"
},
{
"date": "2022-01-04T21:54:36.813000",
"db": "NVD",
"id": "CVE-2021-45552"
},
{
"date": "2022-01-05T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202112-2366"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202112-2366"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-016928"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "command injection",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202112-2366"
}
],
"trust": 0.6
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…