var-202112-2414
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects AC2100 before 1.2.0.88, AC2400 before 1.2.0.88, AC2600 before 1.2.0.88, D7000 before 1.0.1.82, R6220 before 1.1.0.110, R6230 before 1.1.0.110, R6260 before 1.1.0.84, R6330 before 1.1.0.84, R6350 before 1.1.0.84, R6700v2 before 1.2.0.88, R6800 before 1.2.0.88, R6850 before 1.1.0.84, R6900v2 before 1.2.0.88, R7200 before 1.2.0.88, R7350 before 1.2.0.88, R7400 before 1.2.0.88, and R7450 before 1.2.0.88. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects AC2100 prior to 1.2.0.88, AC2400 prior to 1.2.0.88, AC2600 prior to 1.2.0.88, D7000 prior to 1.0.1.82, R6220 prior to 1.1.0.110, R6230 prior to 1.1.0.110, R6260 prior to 1.1.0.84, R6330 prior to 1.1.0.84, R6350 prior to 1.1.0.84, R6700v2 prior to 1.2.0.88, R6800 prior to 1.2.0.88, R6850 prior to 1.1.0.84, R6900v2 prior to 1.2.0.88, R7200 prior to 1.2.0.88, R7350 prior to 1.2.0.88, R7400 prior to 1.2.0.88, and R7450 prior to 1.2.0.88
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", affected_products: { "@id": "https://www.variotdbs.pl/ref/affected_products", }, configurations: { "@id": "https://www.variotdbs.pl/ref/configurations", }, credits: { "@id": "https://www.variotdbs.pl/ref/credits", }, cvss: { "@id": "https://www.variotdbs.pl/ref/cvss/", }, description: { "@id": "https://www.variotdbs.pl/ref/description/", }, exploit_availability: { "@id": "https://www.variotdbs.pl/ref/exploit_availability/", }, external_ids: { "@id": "https://www.variotdbs.pl/ref/external_ids/", }, iot: { "@id": "https://www.variotdbs.pl/ref/iot/", }, iot_taxonomy: { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/", }, patch: { "@id": "https://www.variotdbs.pl/ref/patch/", }, problemtype_data: { "@id": "https://www.variotdbs.pl/ref/problemtype_data/", }, references: { "@id": "https://www.variotdbs.pl/ref/references/", }, sources: { "@id": "https://www.variotdbs.pl/ref/sources/", }, sources_release_date: { "@id": "https://www.variotdbs.pl/ref/sources_release_date/", }, sources_update_date: { "@id": "https://www.variotdbs.pl/ref/sources_update_date/", }, threat_type: { "@id": "https://www.variotdbs.pl/ref/threat_type/", }, title: { "@id": "https://www.variotdbs.pl/ref/title/", }, type: { "@id": "https://www.variotdbs.pl/ref/type/", }, }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2414", affected_products: { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", data: { "@container": "@list", }, sources: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", }, "@id": "https://www.variotdbs.pl/ref/sources", }, }, data: [ { model: "r6330", scope: "lt", trust: 1, vendor: "netgear", version: "1.1.0.84", }, { model: "ac2600", scope: "lt", trust: 1, vendor: "netgear", version: "1.2.0.88", }, { model: "r6700v2", scope: "lt", trust: 1, vendor: "netgear", version: "1.2.0.88", }, { model: "r6850", scope: "lt", trust: 1, vendor: "netgear", version: "1.1.0.84", }, { model: "r6800", scope: "lt", trust: 1, vendor: "netgear", version: "1.2.0.88", }, { model: "r7400", scope: "lt", trust: 1, vendor: "netgear", version: "1.2.0.88", }, { model: "r7200", scope: "lt", trust: 1, vendor: "netgear", version: "1.2.0.88", }, { model: "ac2100", scope: "lt", trust: 1, vendor: "netgear", version: "1.2.0.88", }, { model: "r6260", scope: "lt", trust: 1, vendor: "netgear", version: "1.1.0.84", }, { model: "r6900v2", scope: "lt", trust: 1, vendor: "netgear", version: "1.2.0.88", }, { model: "d7000", scope: "lt", trust: 1, vendor: "netgear", version: "1.0.1.82", }, { model: "r6220", scope: "lt", trust: 1, vendor: "netgear", version: "1.1.0.110", }, { model: "r6230", scope: "lt", trust: 1, vendor: "netgear", version: "1.1.0.110", }, { model: "r6350", scope: "lt", trust: 1, vendor: "netgear", version: "1.1.0.84", }, { model: "ac2400", scope: "lt", trust: 1, vendor: "netgear", version: "1.2.0.88", }, { model: "r7450", scope: "lt", trust: 1, vendor: "netgear", version: "1.2.0.88", }, { model: "r7350", scope: "lt", trust: 1, vendor: "netgear", version: "1.2.0.88", }, { model: "d7000", scope: null, trust: 0.8, vendor: "ネットギア", version: null, }, { model: "r6230", scope: null, trust: 0.8, vendor: "ネットギア", version: null, }, { model: "r6260", scope: null, trust: 0.8, vendor: "ネットギア", version: null, }, { model: "r6330", scope: null, trust: 0.8, vendor: "ネットギア", version: null, }, { model: "ac2600", scope: null, trust: 0.8, vendor: "ネットギア", version: null, }, { model: "ac2100", scope: null, trust: 0.8, vendor: "ネットギア", version: null, }, { model: "r6700v2", scope: null, trust: 0.8, vendor: "ネットギア", version: null, }, { model: "r6220", scope: null, trust: 0.8, vendor: "ネットギア", version: null, }, { model: "ac2400", scope: null, trust: 0.8, vendor: "ネットギア", version: null, }, { model: "r6350", scope: null, trust: 0.8, vendor: "ネットギア", version: null, }, ], sources: [ { db: "JVNDB", id: "JVNDB-2021-017287", }, { db: "NVD", id: "CVE-2021-45534", }, ], }, configurations: { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", children: { "@container": "@list", }, cpe_match: { "@container": "@list", }, data: { "@container": "@list", }, nodes: { "@container": "@list", }, }, data: [ { CVE_data_version: "4.0", nodes: [ { children: [ { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:o:netgear:ac2100_firmware:*:*:*:*:*:*:*:*", cpe_name: [], versionEndExcluding: "1.2.0.88", vulnerable: true, }, ], operator: "OR", }, { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:h:netgear:ac2100:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, ], operator: "OR", }, ], cpe_match: [], operator: "AND", }, { children: [ { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:o:netgear:ac2400_firmware:*:*:*:*:*:*:*:*", cpe_name: [], versionEndExcluding: "1.2.0.88", vulnerable: true, }, ], operator: "OR", }, { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:h:netgear:ac2400:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, ], operator: "OR", }, ], cpe_match: [], operator: "AND", }, { children: [ { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:o:netgear:ac2600_firmware:*:*:*:*:*:*:*:*", cpe_name: [], versionEndExcluding: "1.2.0.88", vulnerable: true, }, ], operator: "OR", }, { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:h:netgear:ac2600:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, ], operator: "OR", }, ], cpe_match: [], operator: "AND", }, { children: [ { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:o:netgear:d7000_firmware:*:*:*:*:*:*:*:*", cpe_name: [], versionEndExcluding: "1.0.1.82", vulnerable: true, }, ], operator: "OR", }, { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:h:netgear:d7000:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, ], operator: "OR", }, ], cpe_match: [], operator: "AND", }, { children: [ { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:o:netgear:r6220_firmware:*:*:*:*:*:*:*:*", cpe_name: [], versionEndExcluding: "1.1.0.110", vulnerable: true, }, ], operator: "OR", }, { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:h:netgear:r6220:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, ], operator: "OR", }, ], cpe_match: [], operator: "AND", }, { children: [ { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:o:netgear:r6230_firmware:*:*:*:*:*:*:*:*", cpe_name: [], versionEndExcluding: "1.1.0.110", vulnerable: true, }, ], operator: "OR", }, { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:h:netgear:r6230:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, ], operator: "OR", }, ], cpe_match: [], operator: "AND", }, { children: [ { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:o:netgear:r6260_firmware:*:*:*:*:*:*:*:*", cpe_name: [], versionEndExcluding: "1.1.0.84", vulnerable: true, }, ], operator: "OR", }, { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:h:netgear:r6260:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, ], operator: "OR", }, ], cpe_match: [], operator: "AND", }, { children: [ { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:o:netgear:r6330_firmware:*:*:*:*:*:*:*:*", cpe_name: [], versionEndExcluding: "1.1.0.84", vulnerable: true, }, ], operator: "OR", }, { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:h:netgear:r6330:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, ], operator: "OR", }, ], cpe_match: [], operator: "AND", }, { children: [ { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:o:netgear:r6350_firmware:*:*:*:*:*:*:*:*", cpe_name: [], versionEndExcluding: "1.1.0.84", vulnerable: true, }, ], operator: "OR", }, { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:h:netgear:r6350:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, ], operator: "OR", }, ], cpe_match: [], operator: "AND", }, { children: [ { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:o:netgear:r6700v2_firmware:*:*:*:*:*:*:*:*", cpe_name: [], versionEndExcluding: "1.2.0.88", vulnerable: true, }, ], operator: "OR", }, { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:h:netgear:r6700v2:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, ], operator: "OR", }, ], cpe_match: [], operator: "AND", }, { children: [ { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:o:netgear:r6800_firmware:*:*:*:*:*:*:*:*", cpe_name: [], versionEndExcluding: "1.2.0.88", vulnerable: true, }, ], operator: "OR", }, { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:h:netgear:r6800:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, ], operator: "OR", }, ], cpe_match: [], operator: "AND", }, { children: [ { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:o:netgear:r6850_firmware:*:*:*:*:*:*:*:*", cpe_name: [], versionEndExcluding: "1.1.0.84", vulnerable: true, }, ], operator: "OR", }, { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:h:netgear:r6850:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, ], operator: "OR", }, ], cpe_match: [], operator: "AND", }, { children: [ { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:o:netgear:r6900v2_firmware:*:*:*:*:*:*:*:*", cpe_name: [], versionEndExcluding: "1.2.0.88", vulnerable: true, }, ], operator: "OR", }, { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:h:netgear:r6900v2:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, ], operator: "OR", }, ], cpe_match: [], operator: "AND", }, { children: [ { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:o:netgear:r7200_firmware:*:*:*:*:*:*:*:*", cpe_name: [], versionEndExcluding: "1.2.0.88", vulnerable: true, }, ], operator: "OR", }, { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:h:netgear:r7200:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, ], operator: "OR", }, ], cpe_match: [], operator: "AND", }, { children: [ { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:o:netgear:r7350_firmware:*:*:*:*:*:*:*:*", cpe_name: [], versionEndExcluding: "1.2.0.88", vulnerable: true, }, ], operator: "OR", }, { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:h:netgear:r7350:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, ], operator: "OR", }, ], cpe_match: [], operator: "AND", }, { children: [ { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:o:netgear:r7400_firmware:*:*:*:*:*:*:*:*", cpe_name: [], versionEndExcluding: "1.2.0.88", vulnerable: true, }, ], operator: "OR", }, { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:h:netgear:r7400:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, ], operator: "OR", }, ], cpe_match: [], operator: "AND", }, { children: [ { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:o:netgear:r7450_firmware:*:*:*:*:*:*:*:*", cpe_name: [], versionEndExcluding: "1.2.0.88", vulnerable: true, }, ], operator: "OR", }, { children: [], cpe_match: [ { cpe23Uri: "cpe:2.3:h:netgear:r7450:-:*:*:*:*:*:*:*", cpe_name: [], vulnerable: false, }, ], operator: "OR", }, ], cpe_match: [], operator: "AND", }, ], }, ], sources: [ { db: "NVD", id: "CVE-2021-45534", }, ], }, cve: "CVE-2021-45534", cvss: { "@context": { cvssV2: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#", }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2", }, cvssV3: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#", }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/", }, severity: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#", }, "@id": "https://www.variotdbs.pl/ref/cvss/severity", }, sources: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", }, "@id": "https://www.variotdbs.pl/ref/sources", }, }, data: [ { cvssV2: [ { acInsufInfo: false, accessComplexity: "LOW", accessVector: "NETWORK", authentication: "SINGLE", author: "NVD", availabilityImpact: "PARTIAL", baseScore: 6.5, confidentialityImpact: "PARTIAL", exploitabilityScore: 8, impactScore: 6.4, integrityImpact: "PARTIAL", obtainAllPrivilege: false, obtainOtherPrivilege: false, obtainUserPrivilege: false, severity: "MEDIUM", trust: 1, userInteractionRequired: false, vectorString: "AV:N/AC:L/Au:S/C:P/I:P/A:P", version: "2.0", }, { acInsufInfo: null, accessComplexity: "Low", accessVector: "Network", authentication: "Single", author: "NVD", availabilityImpact: "Partial", baseScore: 6.5, confidentialityImpact: "Partial", exploitabilityScore: null, id: "CVE-2021-45534", impactScore: null, integrityImpact: "Partial", obtainAllPrivilege: null, obtainOtherPrivilege: null, obtainUserPrivilege: null, severity: "Medium", trust: 0.9, userInteractionRequired: null, vectorString: "AV:N/AC:L/Au:S/C:P/I:P/A:P", version: "2.0", }, ], cvssV3: [ { attackComplexity: "LOW", attackVector: "LOCAL", author: "NVD", availabilityImpact: "HIGH", baseScore: 7.8, baseSeverity: "HIGH", confidentialityImpact: "HIGH", exploitabilityScore: 1.8, impactScore: 5.9, integrityImpact: "HIGH", privilegesRequired: "LOW", scope: "UNCHANGED", trust: 2, userInteraction: "NONE", vectorString: "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", version: "3.1", }, { attackComplexity: "Low", attackVector: "Local", author: "OTHER", availabilityImpact: "High", baseScore: 7.8, baseSeverity: "High", confidentialityImpact: "High", exploitabilityScore: null, id: "JVNDB-2021-017287", impactScore: null, integrityImpact: "High", privilegesRequired: "Low", scope: "Unchanged", trust: 0.8, userInteraction: "None", vectorString: "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", version: "3.0", }, ], severity: [ { author: "NVD", id: "CVE-2021-45534", trust: 1.8, value: "HIGH", }, { author: "cve@mitre.org", id: "CVE-2021-45534", trust: 1, value: "HIGH", }, { author: "CNNVD", id: "CNNVD-202112-2347", trust: 0.6, value: "HIGH", }, { author: "VULMON", id: "CVE-2021-45534", trust: 0.1, value: "MEDIUM", }, ], }, ], sources: [ { db: "VULMON", id: "CVE-2021-45534", }, { db: "JVNDB", id: "JVNDB-2021-017287", }, { db: "NVD", id: "CVE-2021-45534", }, { db: "NVD", id: "CVE-2021-45534", }, { db: "CNNVD", id: "CNNVD-202112-2347", }, ], }, description: { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", sources: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", }, }, }, data: "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects AC2100 before 1.2.0.88, AC2400 before 1.2.0.88, AC2600 before 1.2.0.88, D7000 before 1.0.1.82, R6220 before 1.1.0.110, R6230 before 1.1.0.110, R6260 before 1.1.0.84, R6330 before 1.1.0.84, R6350 before 1.1.0.84, R6700v2 before 1.2.0.88, R6800 before 1.2.0.88, R6850 before 1.1.0.84, R6900v2 before 1.2.0.88, R7200 before 1.2.0.88, R7350 before 1.2.0.88, R7400 before 1.2.0.88, and R7450 before 1.2.0.88. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects AC2100 prior to 1.2.0.88, AC2400 prior to 1.2.0.88, AC2600 prior to 1.2.0.88, D7000 prior to 1.0.1.82, R6220 prior to 1.1.0.110, R6230 prior to 1.1.0.110, R6260 prior to 1.1.0.84, R6330 prior to 1.1.0.84, R6350 prior to 1.1.0.84, R6700v2 prior to 1.2.0.88, R6800 prior to 1.2.0.88, R6850 prior to 1.1.0.84, R6900v2 prior to 1.2.0.88, R7200 prior to 1.2.0.88, R7350 prior to 1.2.0.88, R7400 prior to 1.2.0.88, and R7450 prior to 1.2.0.88", sources: [ { db: "NVD", id: "CVE-2021-45534", }, { db: "JVNDB", id: "JVNDB-2021-017287", }, { db: "VULMON", id: "CVE-2021-45534", }, ], trust: 1.71, }, external_ids: { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", data: { "@container": "@list", }, sources: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", }, }, }, data: [ { db: "NVD", id: "CVE-2021-45534", trust: 3.3, }, { db: "JVNDB", id: "JVNDB-2021-017287", trust: 0.8, }, { db: "CNNVD", id: "CNNVD-202112-2347", trust: 0.6, }, { db: "VULMON", id: "CVE-2021-45534", trust: 0.1, }, ], sources: [ { db: "VULMON", id: "CVE-2021-45534", }, { db: "JVNDB", id: "JVNDB-2021-017287", }, { db: "NVD", id: "CVE-2021-45534", }, { db: "CNNVD", id: "CNNVD-202112-2347", }, ], }, id: "VAR-202112-2414", iot: { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", sources: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", }, }, }, data: true, sources: [ { db: "VARIoT devices database", id: null, }, ], trust: 0.48174049499999994, }, last_update_date: "2023-12-18T12:42:08.867000Z", patch: { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", data: { "@container": "@list", }, sources: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", }, }, }, data: [ { title: "Security Advisory for Post-Authentication Command Injection on Some Routers and DSL Modem Routers, PSV-2021-0172", trust: 0.8, url: "https://kb.netgear.com/000064406/security-advisory-for-post-authentication-command-injection-on-some-routers-and-dsl-modem-routers-psv-2021-0172", }, { title: "Netgear NETGEAR Security vulnerabilities", trust: 0.6, url: "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=176381", }, ], sources: [ { db: "JVNDB", id: "JVNDB-2021-017287", }, { db: "CNNVD", id: "CNNVD-202112-2347", }, ], }, problemtype_data: { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", sources: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", }, }, }, data: [ { problemtype: "CWE-77", trust: 1, }, { problemtype: "Command injection (CWE-77) [NVD evaluation ]", trust: 0.8, }, ], sources: [ { db: "JVNDB", id: "JVNDB-2021-017287", }, { db: "NVD", id: "CVE-2021-45534", }, ], }, references: { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", data: { "@container": "@list", }, sources: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", }, }, }, data: [ { trust: 1.7, url: "https://immersivelabs.com/resources/blog/netgear-vulnerabilities-could-put-small-business-routers-at-risk/", }, { trust: 1.7, url: "https://kb.netgear.com/000064406/security-advisory-for-post-authentication-command-injection-on-some-routers-and-dsl-modem-routers-psv-2021-0172", }, { trust: 1.4, url: "https://nvd.nist.gov/vuln/detail/cve-2021-45534", }, { trust: 0.1, url: "https://cwe.mitre.org/data/definitions/77.html", }, { trust: 0.1, url: "https://nvd.nist.gov", }, ], sources: [ { db: "VULMON", id: "CVE-2021-45534", }, { db: "JVNDB", id: "JVNDB-2021-017287", }, { db: "NVD", id: "CVE-2021-45534", }, { db: "CNNVD", id: "CNNVD-202112-2347", }, ], }, sources: { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", data: { "@container": "@list", }, }, data: [ { db: "VULMON", id: "CVE-2021-45534", }, { db: "JVNDB", id: "JVNDB-2021-017287", }, { db: "NVD", id: "CVE-2021-45534", }, { db: "CNNVD", id: "CNNVD-202112-2347", }, ], }, sources_release_date: { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", data: { "@container": "@list", }, }, data: [ { date: "2021-12-26T00:00:00", db: "VULMON", id: "CVE-2021-45534", }, { date: "2023-01-13T00:00:00", db: "JVNDB", id: "JVNDB-2021-017287", }, { date: "2021-12-26T01:15:14.600000", db: "NVD", id: "CVE-2021-45534", }, { date: "2021-12-26T00:00:00", db: "CNNVD", id: "CNNVD-202112-2347", }, ], }, sources_update_date: { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", data: { "@container": "@list", }, }, data: [ { date: "2022-01-07T00:00:00", db: "VULMON", id: "CVE-2021-45534", }, { date: "2023-01-13T05:03:00", db: "JVNDB", id: "JVNDB-2021-017287", }, { date: "2022-01-07T19:38:30.217000", db: "NVD", id: "CVE-2021-45534", }, { date: "2022-01-10T00:00:00", db: "CNNVD", id: "CNNVD-202112-2347", }, ], }, threat_type: { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", sources: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", }, }, }, data: "local", sources: [ { db: "CNNVD", id: "CNNVD-202112-2347", }, ], trust: 0.6, }, title: { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", sources: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", }, }, }, data: "plural NETGEAR Command injection vulnerability in device", sources: [ { db: "JVNDB", id: "JVNDB-2021-017287", }, ], trust: 0.8, }, type: { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", sources: { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", }, }, }, data: "command injection", sources: [ { db: "CNNVD", id: "CNNVD-202112-2347", }, ], trust: 0.6, }, }
Log in or create an account to share your comment.
This schema specifies the format of a comment related to a security advisory.
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.