var-202203-0587
Vulnerability from variot
Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetStaticRoutecfg function. The Tenda AC9 is a wireless router from the Chinese company Tenda.
There is a buffer overflow vulnerability in Tenda AC9 15.03.2.21. The vulnerability arises from the fact that when the list parameter in the SetStaticRoutecfg function performs operations on memory, the data boundary is not properly verified. An attacker can exploit this vulnerability to execute arbitrary commands
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202203-0587", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac9", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.2.21" }, { "model": "ac9", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "v15.03.2.21" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-26244" }, { "db": "NVD", "id": "CVE-2022-25435" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:tenda:ac9_firmware:15.03.2.21:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2022-25435" } ] }, "cve": "CVE-2022-25435", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2022-26244", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "NVD", "id": "CVE-2022-25435", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNVD", "id": "CNVD-2022-26244", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202203-1852", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-26244" }, { "db": "NVD", "id": "CVE-2022-25435" }, { "db": "CNNVD", "id": "CNNVD-202203-1852" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC9 v15.03.2.21 was discovered to contain a stack overflow via the list parameter in the SetStaticRoutecfg function. The Tenda AC9 is a wireless router from the Chinese company Tenda. \n\r\n\r\nThere is a buffer overflow vulnerability in Tenda AC9 15.03.2.21. The vulnerability arises from the fact that when the list parameter in the SetStaticRoutecfg function performs operations on memory, the data boundary is not properly verified. An attacker can exploit this vulnerability to execute arbitrary commands", "sources": [ { "db": "NVD", "id": "CVE-2022-25435" }, { "db": "CNVD", "id": "CNVD-2022-26244" } ], "trust": 1.44 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-25435", "trust": 2.2 }, { "db": "CNVD", "id": "CNVD-2022-26244", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202203-1852", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-26244" }, { "db": "NVD", "id": "CVE-2022-25435" }, { "db": "CNNVD", "id": "CNNVD-202203-1852" } ] }, "id": "VAR-202203-0587", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2022-26244" } ], "trust": 1.04830826 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-26244" } ] }, "last_update_date": "2023-12-18T13:22:31.312000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Tenda AC9 Buffer Overflow Vulnerability (CNVD-2022-26244)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/328721" }, { "title": "Tenda AC9 Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=186933" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-26244" }, { "db": "CNNVD", "id": "CNNVD-202203-1852" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2022-25435" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.2, "url": "https://github.com/ephaha/iot_vuln/tree/main/tenda/ac9/7" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-25435/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-26244" }, { "db": "NVD", "id": "CVE-2022-25435" }, { "db": "CNNVD", "id": "CNNVD-202203-1852" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2022-26244" }, { "db": "NVD", "id": "CVE-2022-25435" }, { "db": "CNNVD", "id": "CNNVD-202203-1852" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-04-06T00:00:00", "db": "CNVD", "id": "CNVD-2022-26244" }, { "date": "2022-03-18T21:15:08.130000", "db": "NVD", "id": "CVE-2022-25435" }, { "date": "2022-03-18T00:00:00", "db": "CNNVD", "id": "CNNVD-202203-1852" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-04-06T00:00:00", "db": "CNVD", "id": "CNVD-2022-26244" }, { "date": "2023-08-08T14:21:49.707000", "db": "NVD", "id": "CVE-2022-25435" }, { "date": "2022-03-28T00:00:00", "db": "CNNVD", "id": "CNNVD-202203-1852" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202203-1852" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC9 Buffer Overflow Vulnerability (CNVD-2022-26244)", "sources": [ { "db": "CNVD", "id": "CNVD-2022-26244" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202203-1852" } ], "trust": 0.6 } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.