var-202205-0172
Vulnerability from variot
Tenda AC15 US_AC15V1.0BR_V15.03.05.20_multi_TDE01.bin is vulnerable to Buffer Overflow. The stack overflow vulnerability lies in the /goform/setpptpservercfg interface of the web. The sent post data startip and endip are copied to the stack using the sanf function, resulting in stack overflow. Similarly, this vulnerability can be used together with CVE-2021-44971. Shenzhen Tenda Technology Co.,Ltd. of AC15 A vulnerability exists in the firmware regarding resource allocation without limits or throttling.Service operation interruption (DoS) It may be in a state.
Tenda AC15 has security flaws that can be exploited by attackers to cause stack overflow
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202205-0172", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ac15", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "15.03.05.20_multi_tde01" }, { "model": "ac15", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac15", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "ac15", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "ac15 firmware 15.03.05.20 multi tde01" }, { "model": "ac15 15.03.05.20 multi tde01", "scope": null, "trust": 0.6, "vendor": "tenda", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-38165" }, { "db": "JVNDB", "id": "JVNDB-2022-009240" }, { "db": "NVD", "id": "CVE-2022-28556" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.20_multi_tde01:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:tenda:ac15:1.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2022-28556" } ] }, "cve": "CVE-2022-28556", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "impactScore": 2.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.0, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2022-28556", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2022-38165", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2022-28556", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2022-28556", "trust": 1.8, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2022-38165", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202205-2140", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2022-28556", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-38165" }, { "db": "VULMON", "id": "CVE-2022-28556" }, { "db": "JVNDB", "id": "JVNDB-2022-009240" }, { "db": "NVD", "id": "CVE-2022-28556" }, { "db": "CNNVD", "id": "CNNVD-202205-2140" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda AC15 US_AC15V1.0BR_V15.03.05.20_multi_TDE01.bin is vulnerable to Buffer Overflow. The stack overflow vulnerability lies in the /goform/setpptpservercfg interface of the web. The sent post data startip and endip are copied to the stack using the sanf function, resulting in stack overflow. Similarly, this vulnerability can be used together with CVE-2021-44971. Shenzhen Tenda Technology Co.,Ltd. of AC15 A vulnerability exists in the firmware regarding resource allocation without limits or throttling.Service operation interruption (DoS) It may be in a state. \n\r\n\r\nTenda AC15 has security flaws that can be exploited by attackers to cause stack overflow", "sources": [ { "db": "NVD", "id": "CVE-2022-28556" }, { "db": "JVNDB", "id": "JVNDB-2022-009240" }, { "db": "CNVD", "id": "CNVD-2022-38165" }, { "db": "VULMON", "id": "CVE-2022-28556" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-28556", "trust": 3.9 }, { "db": "JVNDB", "id": "JVNDB-2022-009240", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2022-38165", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202205-2140", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2022-28556", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-38165" }, { "db": "VULMON", "id": "CVE-2022-28556" }, { "db": "JVNDB", "id": "JVNDB-2022-009240" }, { "db": "NVD", "id": "CVE-2022-28556" }, { "db": "CNNVD", "id": "CNNVD-202205-2140" } ] }, "id": "VAR-202205-0172", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2022-38165" } ], "trust": 1.3462292 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-38165" } ] }, "last_update_date": "2023-12-18T11:56:07.805000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Tenda AC15 Buffer Overflow Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/333211" }, { "title": "Tenda AC15 Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=192829" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-38165" }, { "db": "CNNVD", "id": "CNNVD-202205-2140" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Allocation of resources without limits or throttling (CWE-770) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-009240" }, { "db": "NVD", "id": "CVE-2022-28556" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://github.com/doudoudedi/tendaac15_vul/blob/main/tendaac15-vul.md" }, { "trust": 1.2, "url": "https://cxsecurity.com/cveshow/cve-2022-28556/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2022-28556" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/770.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-38165" }, { "db": "VULMON", "id": "CVE-2022-28556" }, { "db": "JVNDB", "id": "JVNDB-2022-009240" }, { "db": "NVD", "id": "CVE-2022-28556" }, { "db": "CNNVD", "id": "CNNVD-202205-2140" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2022-38165" }, { "db": "VULMON", "id": "CVE-2022-28556" }, { "db": "JVNDB", "id": "JVNDB-2022-009240" }, { "db": "NVD", "id": "CVE-2022-28556" }, { "db": "CNNVD", "id": "CNNVD-202205-2140" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-05-20T00:00:00", "db": "CNVD", "id": "CNVD-2022-38165" }, { "date": "2022-05-04T00:00:00", "db": "VULMON", "id": "CVE-2022-28556" }, { "date": "2023-08-03T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-009240" }, { "date": "2022-05-04T16:15:08.647000", "db": "NVD", "id": "CVE-2022-28556" }, { "date": "2022-05-04T00:00:00", "db": "CNNVD", "id": "CNNVD-202205-2140" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-05-19T00:00:00", "db": "CNVD", "id": "CNVD-2022-38165" }, { "date": "2022-05-13T00:00:00", "db": "VULMON", "id": "CVE-2022-28556" }, { "date": "2023-08-03T08:30:00", "db": "JVNDB", "id": "JVNDB-2022-009240" }, { "date": "2023-08-08T14:21:49.707000", "db": "NVD", "id": "CVE-2022-28556" }, { "date": "2022-05-16T00:00:00", "db": "CNNVD", "id": "CNNVD-202205-2140" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202205-2140" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC15\u00a0 Unlimited or Throttling Resource Allocation Vulnerability in Firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-009240" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202205-2140" } ], "trust": 0.6 } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.