VAR-202208-0251
Vulnerability from variot - Updated: 2023-12-18 11:55Cleartext transmission of sensitive information vulnerability in authentication management in Synology Note Station Client before 2.2.2-609 allows man-in-the-middle attackers to obtain sensitive information via unspecified vectors. Synology Inc
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202208-0251",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "note station",
"scope": "lt",
"trust": 1.0,
"vendor": "synology",
"version": "2.2.2-609"
},
{
"model": "note station",
"scope": "eq",
"trust": 0.8,
"vendor": "synology",
"version": null
},
{
"model": "note station",
"scope": null,
"trust": 0.8,
"vendor": "synology",
"version": null
},
{
"model": "note station",
"scope": "eq",
"trust": 0.8,
"vendor": "synology",
"version": "2.2.2-609"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-014124"
},
{
"db": "NVD",
"id": "CVE-2022-27619"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:synology:note_station:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2.2.2-609",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2022-27619"
}
]
},
"cve": "CVE-2022-27619",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.2,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
{
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"author": "security@synology.com",
"availabilityImpact": "NONE",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.2,
"impactScore": 4.0,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
},
{
"attackComplexity": "High",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 5.9,
"baseSeverity": "Medium",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2022-27619",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2022-27619",
"trust": 1.8,
"value": "MEDIUM"
},
{
"author": "security@synology.com",
"id": "CVE-2022-27619",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202208-2049",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-014124"
},
{
"db": "NVD",
"id": "CVE-2022-27619"
},
{
"db": "NVD",
"id": "CVE-2022-27619"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2049"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Cleartext transmission of sensitive information vulnerability in authentication management in Synology Note Station Client before 2.2.2-609 allows man-in-the-middle attackers to obtain sensitive information via unspecified vectors. Synology Inc",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-27619"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014124"
},
{
"db": "VULHUB",
"id": "VHN-418272"
},
{
"db": "VULMON",
"id": "CVE-2022-27619"
}
],
"trust": 1.8
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-27619",
"trust": 3.4
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014124",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2049",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-418272",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2022-27619",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-418272"
},
{
"db": "VULMON",
"id": "CVE-2022-27619"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014124"
},
{
"db": "NVD",
"id": "CVE-2022-27619"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2049"
}
]
},
"id": "VAR-202208-0251",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-418272"
}
],
"trust": 0.01
},
"last_update_date": "2023-12-18T11:55:46.277000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Synology Note Station Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=203488"
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-2049"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-319",
"trust": 1.1
},
{
"problemtype": "Sending important information in clear text (CWE-319) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-418272"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014124"
},
{
"db": "NVD",
"id": "CVE-2022-27619"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.6,
"url": "https://www.synology.com/security/advisory/synology_sa_22_12"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-27619"
},
{
"trust": 0.6,
"url": "https://vigilance.fr/vulnerability/synology-dsm-man-in-the-middle-via-note-station-client-38978"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-27619/"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/319.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-418272"
},
{
"db": "VULMON",
"id": "CVE-2022-27619"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014124"
},
{
"db": "NVD",
"id": "CVE-2022-27619"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2049"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-418272"
},
{
"db": "VULMON",
"id": "CVE-2022-27619"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-014124"
},
{
"db": "NVD",
"id": "CVE-2022-27619"
},
{
"db": "CNNVD",
"id": "CNNVD-202208-2049"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-08-03T00:00:00",
"db": "VULHUB",
"id": "VHN-418272"
},
{
"date": "2022-08-03T00:00:00",
"db": "VULMON",
"id": "CVE-2022-27619"
},
{
"date": "2023-09-14T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-014124"
},
{
"date": "2022-08-03T03:15:08.227000",
"db": "NVD",
"id": "CVE-2022-27619"
},
{
"date": "2022-08-03T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202208-2049"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-08-09T00:00:00",
"db": "VULHUB",
"id": "VHN-418272"
},
{
"date": "2022-08-03T00:00:00",
"db": "VULMON",
"id": "CVE-2022-27619"
},
{
"date": "2023-09-14T08:12:00",
"db": "JVNDB",
"id": "JVNDB-2022-014124"
},
{
"date": "2022-08-09T13:14:03.220000",
"db": "NVD",
"id": "CVE-2022-27619"
},
{
"date": "2022-08-10T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202208-2049"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-2049"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Synology\u00a0Inc.\u00a0 of \u00a0Note\u00a0Station\u00a0 Vulnerability in plaintext transmission of important information in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-014124"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "other",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202208-2049"
}
],
"trust": 0.6
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…