var-202208-0305
Vulnerability from variot

Contiki-NG is an open-source, cross-platform operating system for IoT devices. In the RPL-Classic routing protocol implementation in the Contiki-NG operating system, an incoming DODAG Information Option (DIO) control message can contain a prefix information option with a length parameter. The value of the length parameter is not validated, however, and it is possible to cause a buffer overflow when copying the prefix in the set_ip_from_prefix function. This vulnerability affects anyone running a Contiki-NG version prior to 4.7 that can receive RPL DIO messages from external parties. To obtain a patched version, users should upgrade to Contiki-NG 4.7 or later. There are no workarounds for this issue. Contiki-NG Exists in a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. There is a security vulnerability in the version before Contiki-NG 4.7. An attacker exploiting this vulnerability can cause a buffer overflow

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202208-0305",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "contiki-ng",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "contiki ng",
        "version": "4.7"
      },
      {
        "model": "contiki-ng",
        "scope": null,
        "trust": 0.8,
        "vendor": "contiki ng",
        "version": null
      },
      {
        "model": "contiki-ng",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "contiki ng",
        "version": null
      },
      {
        "model": "contiki-ng",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "contiki ng",
        "version": "4.7"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014245"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-35927"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:o:contiki-ng:contiki-ng:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "4.7",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-35927"
      }
    ]
  },
  "cve": "CVE-2022-35927",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "author": "security-advisories@github.com",
            "availabilityImpact": "HIGH",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.2,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-35927",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2022-35927",
            "trust": 1.8,
            "value": "CRITICAL"
          },
          {
            "author": "security-advisories@github.com",
            "id": "CVE-2022-35927",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202208-2177",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014245"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-35927"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-35927"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-2177"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Contiki-NG is an open-source, cross-platform operating system for IoT devices. In the RPL-Classic routing protocol implementation in the Contiki-NG operating system, an incoming DODAG Information Option (DIO) control message can contain a prefix information option with a length parameter. The value of the length parameter is not validated, however, and it is possible to cause a buffer overflow when copying the prefix in the set_ip_from_prefix function. This vulnerability affects anyone running a Contiki-NG version prior to 4.7 that can receive RPL DIO messages from external parties. To obtain a patched version, users should upgrade to Contiki-NG 4.7 or later. There are no workarounds for this issue. Contiki-NG Exists in a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. \nThere is a security vulnerability in the version before Contiki-NG 4.7. An attacker exploiting this vulnerability can cause a buffer overflow",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-35927"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014245"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-2177"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-35927"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-35927",
        "trust": 3.3
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014245",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-2177",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-35927",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2022-35927"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014245"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-35927"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-2177"
      }
    ]
  },
  "id": "VAR-202208-0305",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.48177084
  },
  "last_update_date": "2023-12-18T12:48:34.957000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Contiki-NG Security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=203976"
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-2177"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-120",
        "trust": 1.0
      },
      {
        "problemtype": "Classic buffer overflow (CWE-120) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014245"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-35927"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://github.com/contiki-ng/contiki-ng/pull/1589/commits/4fffab0e632c4d01910fa957d1fd9ef321eb87d2"
      },
      {
        "trust": 2.5,
        "url": "https://github.com/contiki-ng/contiki-ng/security/advisories/ghsa-9rm9-3phh-p4wm"
      },
      {
        "trust": 1.9,
        "url": "https://github.com/contiki-ng/contiki-ng/pull/1589"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-35927"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-35927/"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2022-35927"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014245"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-35927"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-2177"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULMON",
        "id": "CVE-2022-35927"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014245"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-35927"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-2177"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-08-04T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-35927"
      },
      {
        "date": "2023-09-15T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-014245"
      },
      {
        "date": "2022-08-04T21:15:08.103000",
        "db": "NVD",
        "id": "CVE-2022-35927"
      },
      {
        "date": "2022-08-04T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202208-2177"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-08-04T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-35927"
      },
      {
        "date": "2023-09-15T08:07:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-014245"
      },
      {
        "date": "2022-08-11T15:14:11.733000",
        "db": "NVD",
        "id": "CVE-2022-35927"
      },
      {
        "date": "2022-08-12T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202208-2177"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-2177"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Contiki-NG\u00a0 Classic buffer overflow vulnerability in",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-014245"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-2177"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.