VAR-202302-0666
Vulnerability from variot - Updated: 2023-12-18 12:33If an attacker were to access memory locations of LS ELECTRIC XBC-DN32U with operating system version 01.80 that are outside of the communication buffer, the device stops operating. This could allow an attacker to cause a denial-of-service condition. ls-electric of xbc-dn32u A firmware vulnerability exists regarding access to memory areas after the end of a buffer.Service operation interruption (DoS) It may be in a state. LS ELECTRIC XBC-DN32U is a PLC programmable logic controller produced by LS ELECTRIC in Korea.
There is a denial of service vulnerability in LS ELECTRIC XBC-DN32U
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202302-0666",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "xbc-dn32u",
"scope": "eq",
"trust": 1.0,
"vendor": "ls electric",
"version": "01.80"
},
{
"model": "xbc-dn32u",
"scope": "eq",
"trust": 0.8,
"vendor": "ls electric",
"version": "xbc-dn32u firmware 01.80"
},
{
"model": "xbc-dn32u",
"scope": "eq",
"trust": 0.8,
"vendor": "ls electric",
"version": null
},
{
"model": "xbc-dn32u",
"scope": null,
"trust": 0.8,
"vendor": "ls electric",
"version": null
},
{
"model": "electric xbc-dn32u",
"scope": "eq",
"trust": 0.6,
"vendor": "ls",
"version": "01.80"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-21683"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-004164"
},
{
"db": "NVD",
"id": "CVE-2023-0103"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:ls-electric:xbc-dn32u_firmware:01.80:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:ls-electric:xbc-dn32u:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-0103"
}
]
},
"cve": "CVE-2023-0103",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2023-21683",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2023-0103",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-0103",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "ics-cert@hq.dhs.gov",
"id": "CVE-2023-0103",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2023-21683",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202302-1275",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-21683"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-004164"
},
{
"db": "NVD",
"id": "CVE-2023-0103"
},
{
"db": "NVD",
"id": "CVE-2023-0103"
},
{
"db": "CNNVD",
"id": "CNNVD-202302-1275"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "If an attacker were to access memory locations of LS ELECTRIC XBC-DN32U with operating system version 01.80 that are outside of the communication buffer, the device stops operating. This could allow an attacker to cause a denial-of-service condition. ls-electric of xbc-dn32u A firmware vulnerability exists regarding access to memory areas after the end of a buffer.Service operation interruption (DoS) It may be in a state. LS ELECTRIC XBC-DN32U is a PLC programmable logic controller produced by LS ELECTRIC in Korea. \n\r\n\r\nThere is a denial of service vulnerability in LS ELECTRIC XBC-DN32U",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-0103"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-004164"
},
{
"db": "CNVD",
"id": "CNVD-2023-21683"
},
{
"db": "VULMON",
"id": "CVE-2023-0103"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-0103",
"trust": 3.9
},
{
"db": "ICS CERT",
"id": "ICSA-23-040-02",
"trust": 3.1
},
{
"db": "JVN",
"id": "JVNVU97136726",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2023-004164",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2023-21683",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202302-1275",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-0103",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-21683"
},
{
"db": "VULMON",
"id": "CVE-2023-0103"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-004164"
},
{
"db": "NVD",
"id": "CVE-2023-0103"
},
{
"db": "CNNVD",
"id": "CNNVD-202302-1275"
}
]
},
"id": "VAR-202302-0666",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-21683"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-21683"
}
]
},
"last_update_date": "2023-12-18T12:33:59.472000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-788",
"trust": 1.0
},
{
"problemtype": "Access to the memory area after the end of the buffer (CWE-788) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-004164"
},
{
"db": "NVD",
"id": "CVE-2023-0103"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.3,
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-040-02"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu97136726/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-0103"
},
{
"trust": 0.8,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-040-02"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2023-0103/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-21683"
},
{
"db": "VULMON",
"id": "CVE-2023-0103"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-004164"
},
{
"db": "NVD",
"id": "CVE-2023-0103"
},
{
"db": "CNNVD",
"id": "CNNVD-202302-1275"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2023-21683"
},
{
"db": "VULMON",
"id": "CVE-2023-0103"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-004164"
},
{
"db": "NVD",
"id": "CVE-2023-0103"
},
{
"db": "CNNVD",
"id": "CNNVD-202302-1275"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-03-29T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-21683"
},
{
"date": "2023-10-26T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-004164"
},
{
"date": "2023-02-15T18:15:11.590000",
"db": "NVD",
"id": "CVE-2023-0103"
},
{
"date": "2023-02-15T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202302-1275"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-03-29T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-21683"
},
{
"date": "2023-10-26T05:07:00",
"db": "JVNDB",
"id": "JVNDB-2023-004164"
},
{
"date": "2023-11-07T03:59:39.707000",
"db": "NVD",
"id": "CVE-2023-0103"
},
{
"date": "2023-02-27T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202302-1275"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202302-1275"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "ls-electric\u00a0 of \u00a0xbc-dn32u\u00a0 Vulnerability in firmware related to accessing memory area after buffer end",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-004164"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "other",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202302-1275"
}
],
"trust": 0.6
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…