VAR-202307-0573
Vulnerability from variot - Updated: 2024-01-21 21:18A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0002). The affected application is vulnerable to stack-based buffer overflow while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21060). Siemens' tecnomatix Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of SPP files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. Siemens Tecnomatix Plant Simulation is an industrial control device of Siemens, Germany. It uses discrete event simulation to analyze and optimize production volume, thereby improving the performance of manufacturing systems
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202307-0573",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "tecnomatix",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2302.0002"
},
{
"model": "tecnomatix",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2201.0008"
},
{
"model": "tecnomatix",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "2201"
},
{
"model": "tecnomatix",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "2302"
},
{
"model": "tecnomatix",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "tecnomatix",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": "2302 that\u0027s all 2302.0002"
},
{
"model": "tecnomatix",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": "2201 that\u0027s all 2201.0008"
},
{
"model": "tecnomatix",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "tecnomatix plant simulation",
"scope": null,
"trust": 0.7,
"vendor": "siemens",
"version": null
},
{
"model": "tecnomatix plant simulation",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v2201\u003cv2201.0008"
},
{
"model": "tecnomatix plant simulation",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v2302\u003cv2302.0002"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-1573"
},
{
"db": "CNVD",
"id": "CNVD-2023-56535"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021701"
},
{
"db": "NVD",
"id": "CVE-2023-37375"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:tecnomatix:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2302.0002",
"versionStartIncluding": "2302",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:tecnomatix:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2201.0008",
"versionStartIncluding": "2201",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-37375"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Simon Janz (@esj4y)",
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-1573"
}
],
"trust": 0.7
},
"cve": "CVE-2023-37375",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.9,
"id": "CNVD-2023-56535",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-37375",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "ZDI",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"id": "CVE-2023-37375",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 0.7,
"userInteraction": "REQUIRED",
"vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-37375",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "productcert@siemens.com",
"id": "CVE-2023-37375",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "ZDI",
"id": "CVE-2023-37375",
"trust": 0.7,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2023-56535",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202307-726",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-1573"
},
{
"db": "CNVD",
"id": "CNVD-2023-56535"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021701"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-726"
},
{
"db": "NVD",
"id": "CVE-2023-37375"
},
{
"db": "NVD",
"id": "CVE-2023-37375"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0008), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0002). The affected application is vulnerable to stack-based buffer overflow while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21060). Siemens\u0027 tecnomatix Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of SPP files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. Siemens Tecnomatix Plant Simulation is an industrial control device of Siemens, Germany. It uses discrete event simulation to analyze and optimize production volume, thereby improving the performance of manufacturing systems",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-37375"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021701"
},
{
"db": "ZDI",
"id": "ZDI-23-1573"
},
{
"db": "CNVD",
"id": "CNVD-2023-56535"
},
{
"db": "VULMON",
"id": "CVE-2023-37375"
}
],
"trust": 2.88
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-37375",
"trust": 4.6
},
{
"db": "SIEMENS",
"id": "SSA-764801",
"trust": 3.1
},
{
"db": "JVN",
"id": "JVNVU95292697",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021701",
"trust": 0.8
},
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-21060",
"trust": 0.7
},
{
"db": "ZDI",
"id": "ZDI-23-1573",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2023-56535",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202307-726",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-37375",
"trust": 0.1
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-1573"
},
{
"db": "CNVD",
"id": "CNVD-2023-56535"
},
{
"db": "VULMON",
"id": "CVE-2023-37375"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021701"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-726"
},
{
"db": "NVD",
"id": "CVE-2023-37375"
}
]
},
"id": "VAR-202307-0573",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-56535"
}
],
"trust": 1.020371905
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-56535"
}
]
},
"last_update_date": "2024-01-21T21:18:17.177000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Siemens has issued an update to correct this vulnerability.",
"trust": 0.7,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-764801.html"
},
{
"title": "Patch for Siemens Tecnomatix Plant Simulation Stack Buffer Overflow Vulnerability (CNVD-2023-56535)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/443041"
},
{
"title": "Siemens Tecnomatix Plant Simulation Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=246649"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-1573"
},
{
"db": "CNVD",
"id": "CNVD-2023-56535"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-726"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021701"
},
{
"db": "NVD",
"id": "CVE-2023-37375"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-764801.pdf"
},
{
"trust": 1.3,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-764801.html"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu95292697/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-37375"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2023-37375/"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-1573"
},
{
"db": "CNVD",
"id": "CNVD-2023-56535"
},
{
"db": "VULMON",
"id": "CVE-2023-37375"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021701"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-726"
},
{
"db": "NVD",
"id": "CVE-2023-37375"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "ZDI",
"id": "ZDI-23-1573"
},
{
"db": "CNVD",
"id": "CNVD-2023-56535"
},
{
"db": "VULMON",
"id": "CVE-2023-37375"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021701"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-726"
},
{
"db": "NVD",
"id": "CVE-2023-37375"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-10-19T00:00:00",
"db": "ZDI",
"id": "ZDI-23-1573"
},
{
"date": "2023-07-17T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-56535"
},
{
"date": "2023-07-11T00:00:00",
"db": "VULMON",
"id": "CVE-2023-37375"
},
{
"date": "2024-01-19T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-021701"
},
{
"date": "2023-07-11T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202307-726"
},
{
"date": "2023-07-11T10:15:11.813000",
"db": "NVD",
"id": "CVE-2023-37375"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-10-19T00:00:00",
"db": "ZDI",
"id": "ZDI-23-1573"
},
{
"date": "2023-07-17T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-56535"
},
{
"date": "2023-07-11T00:00:00",
"db": "VULMON",
"id": "CVE-2023-37375"
},
{
"date": "2024-01-19T08:06:00",
"db": "JVNDB",
"id": "JVNDB-2023-021701"
},
{
"date": "2023-07-19T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202307-726"
},
{
"date": "2023-07-18T14:55:14.487000",
"db": "NVD",
"id": "CVE-2023-37375"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-726"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens\u0027 \u00a0tecnomatix\u00a0 Out-of-bounds write vulnerability in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021701"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-726"
}
],
"trust": 0.6
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.