var-202312-0238
Vulnerability from variot
A vulnerability has been identified in Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 7), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an improper input validation vulnerability that could allow an attacker to bring the service into a Denial-of-Service state by sending a specifically crafted message to 4004/tcp. The corresponding service is auto-restarted after the crash is detected by a watchdog. Opcenter Quality , SIMATIC PCS neo , sinumerik integrate runmyhmi /automotive Unspecified vulnerabilities exist in multiple Siemens products.Service operation interruption (DoS) It may be in a state. Opcenter Quality is a quality management system (QMS) that enables organizations to ensure compliance, optimize quality, reduce defect and rework costs, and achieve operational excellence by increasing process stability. SIMATIC PCS neo is a distributed control system (DCS). The SINUMERIK integrated product suite facilitates simple networking of machine tools in IT in production environments. User Management Component (UMC) is an integrated component that enables system-wide centralized maintenance of users.
There is an improper input validation vulnerability in Siemens User Management Component (UMC)
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202312-0238", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic pcs neo", "scope": "lt", "trust": 1.6, "vendor": "siemens", "version": "4.1" }, { "model": "totally integrated automation portal", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "18" }, { "model": "opcenter quality", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "sinumerik integrate runmyhmi \\/automotive", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "totally integrated automation portal", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "14.0" }, { "model": "totally integrated automation portal", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "17" }, { "model": "totally integrated automation portal", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "18" }, { "model": "totally integrated automation portal", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "totally integrated automation portal", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "15" }, { "model": "totally integrated automation portal", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "totally integrated automation portal", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "15" }, { "model": "totally integrated automation portal", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "17" }, { "model": "totally integrated automation portal", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "simatic pcs neo", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "opcenter quality", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "totally integrated automation portal", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "sinumerik integrate runmyhmi /automotive", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "totally integrated automation portal", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v16" }, { "model": "totally integrated automation portal", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v17" }, { "model": "totally integrated automation portal", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v14" }, { "model": "opcenter quality", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "sinumerik integrate runmyhmi /automotive", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "totally integrated automation portal update", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v18\u003cv183" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-97279" }, { "db": "JVNDB", "id": "JVNDB-2023-019619" }, { "db": "NVD", "id": "CVE-2023-46285" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:totally_integrated_automation_portal:18:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:totally_integrated_automation_portal:18:update_1:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "16", "versionStartIncluding": "15", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "17", "versionStartIncluding": "16", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:totally_integrated_automation_portal:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:opcenter_quality:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "18", "versionStartIncluding": "17", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "15", "versionStartIncluding": "14.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:sinumerik_integrate_runmyhmi_\\/automotive:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2023-46285" } ] }, "cve": "CVE-2023-46285", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2023-97279", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "productcert@siemens.com", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "OTHER", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2023-019619", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "productcert@siemens.com", "id": "CVE-2023-46285", "trust": 1.0, "value": "HIGH" }, { "author": "OTHER", "id": "JVNDB-2023-019619", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2023-97279", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-97279" }, { "db": "JVNDB", "id": "JVNDB-2023-019619" }, { "db": "NVD", "id": "CVE-2023-46285" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in Opcenter Quality (All versions \u003c V2312), SIMATIC PCS neo (All versions \u003c V4.1), SINEC NMS (All versions \u003c V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 7), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). The affected application contains an improper input validation vulnerability that could allow an attacker to bring the service into a Denial-of-Service state by sending a specifically crafted message to 4004/tcp. The corresponding service is auto-restarted after the crash is detected by a watchdog. Opcenter Quality , SIMATIC PCS neo , sinumerik integrate runmyhmi /automotive Unspecified vulnerabilities exist in multiple Siemens products.Service operation interruption (DoS) It may be in a state. Opcenter Quality is a quality management system (QMS) that enables organizations to ensure compliance, optimize quality, reduce defect and rework costs, and achieve operational excellence by increasing process stability. SIMATIC PCS neo is a distributed control system (DCS). The SINUMERIK integrated product suite facilitates simple networking of machine tools in IT in production environments. User Management Component (UMC) is an integrated component that enables system-wide centralized maintenance of users. \n\r\n\r\nThere is an improper input validation vulnerability in Siemens User Management Component (UMC)", "sources": [ { "db": "NVD", "id": "CVE-2023-46285" }, { "db": "JVNDB", "id": "JVNDB-2023-019619" }, { "db": "CNVD", "id": "CNVD-2023-97279" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-46285", "trust": 3.2 }, { "db": "SIEMENS", "id": "SSA-999588", "trust": 2.4 }, { "db": "ICS CERT", "id": "ICSA-23-348-03", "trust": 0.8 }, { "db": "JVN", "id": "JVNVU98271228", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2023-019619", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2023-97279", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-97279" }, { "db": "JVNDB", "id": "JVNDB-2023-019619" }, { "db": "NVD", "id": "CVE-2023-46285" } ] }, "id": "VAR-202312-0238", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-97279" } ], "trust": 1.2076923 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-97279" } ] }, "last_update_date": "2024-05-14T19:25:50.562000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Siemens User Management Component (UMC) Improper Input Validation Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/500461" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-97279" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "Lack of information (CWE-noinfo) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-019619" }, { "db": "NVD", "id": "CVE-2023-46285" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf" }, { "trust": 1.6, "url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu98271228/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-46285" }, { "trust": 0.8, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-348-03" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-97279" }, { "db": "JVNDB", "id": "JVNDB-2023-019619" }, { "db": "NVD", "id": "CVE-2023-46285" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-97279" }, { "db": "JVNDB", "id": "JVNDB-2023-019619" }, { "db": "NVD", "id": "CVE-2023-46285" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-15T00:00:00", "db": "CNVD", "id": "CNVD-2023-97279" }, { "date": "2024-01-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-019619" }, { "date": "2023-12-12T12:15:14.477000", "db": "NVD", "id": "CVE-2023-46285" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-13T00:00:00", "db": "CNVD", "id": "CNVD-2023-97279" }, { "date": "2024-01-15T02:22:00", "db": "JVNDB", "id": "JVNDB-2023-019619" }, { "date": "2024-05-14T16:15:45.917000", "db": "NVD", "id": "CVE-2023-46285" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Vulnerabilities in multiple Siemens products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-019619" } ], "trust": 0.8 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.