VAR-202312-0238
Vulnerability from variot - Updated: 2024-05-14 19:25A vulnerability has been identified in Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 7), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an improper input validation vulnerability that could allow an attacker to bring the service into a Denial-of-Service state by sending a specifically crafted message to 4004/tcp. The corresponding service is auto-restarted after the crash is detected by a watchdog. Opcenter Quality , SIMATIC PCS neo , sinumerik integrate runmyhmi /automotive Unspecified vulnerabilities exist in multiple Siemens products.Service operation interruption (DoS) It may be in a state. Opcenter Quality is a quality management system (QMS) that enables organizations to ensure compliance, optimize quality, reduce defect and rework costs, and achieve operational excellence by increasing process stability. SIMATIC PCS neo is a distributed control system (DCS). The SINUMERIK integrated product suite facilitates simple networking of machine tools in IT in production environments. User Management Component (UMC) is an integrated component that enables system-wide centralized maintenance of users.
There is an improper input validation vulnerability in Siemens User Management Component (UMC)
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202312-0238",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "simatic pcs neo",
"scope": "lt",
"trust": 1.6,
"vendor": "siemens",
"version": "4.1"
},
{
"model": "totally integrated automation portal",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "18"
},
{
"model": "opcenter quality",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "sinumerik integrate runmyhmi \\/automotive",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "totally integrated automation portal",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "14.0"
},
{
"model": "totally integrated automation portal",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "17"
},
{
"model": "totally integrated automation portal",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "18"
},
{
"model": "totally integrated automation portal",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "totally integrated automation portal",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "15"
},
{
"model": "totally integrated automation portal",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "16"
},
{
"model": "totally integrated automation portal",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "15"
},
{
"model": "totally integrated automation portal",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "17"
},
{
"model": "totally integrated automation portal",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "16"
},
{
"model": "simatic pcs neo",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "opcenter quality",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "totally integrated automation portal",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "sinumerik integrate runmyhmi /automotive",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "totally integrated automation portal",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v16"
},
{
"model": "totally integrated automation portal",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v17"
},
{
"model": "totally integrated automation portal",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v14"
},
{
"model": "opcenter quality",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "sinumerik integrate runmyhmi /automotive",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "totally integrated automation portal update",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v18\u003cv183"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-97279"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-019619"
},
{
"db": "NVD",
"id": "CVE-2023-46285"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:totally_integrated_automation_portal:18:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "4.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:totally_integrated_automation_portal:18:update_1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "16",
"versionStartIncluding": "15",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "17",
"versionStartIncluding": "16",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:totally_integrated_automation_portal:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:opcenter_quality:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "18",
"versionStartIncluding": "17",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:totally_integrated_automation_portal:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "15",
"versionStartIncluding": "14.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:sinumerik_integrate_runmyhmi_\\/automotive:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-46285"
}
]
},
"cve": "CVE-2023-46285",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2023-97279",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "productcert@siemens.com",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "JVNDB-2023-019619",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "productcert@siemens.com",
"id": "CVE-2023-46285",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "OTHER",
"id": "JVNDB-2023-019619",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2023-97279",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-97279"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-019619"
},
{
"db": "NVD",
"id": "CVE-2023-46285"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in Opcenter Quality (All versions \u003c V2312), SIMATIC PCS neo (All versions \u003c V4.1), SINEC NMS (All versions \u003c V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 7), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 3). The affected application contains an improper input validation vulnerability that could allow an attacker to bring the service into a Denial-of-Service state by sending a specifically crafted message to 4004/tcp. The corresponding service is auto-restarted after the crash is detected by a watchdog. Opcenter Quality , SIMATIC PCS neo , sinumerik integrate runmyhmi /automotive Unspecified vulnerabilities exist in multiple Siemens products.Service operation interruption (DoS) It may be in a state. Opcenter Quality is a quality management system (QMS) that enables organizations to ensure compliance, optimize quality, reduce defect and rework costs, and achieve operational excellence by increasing process stability. SIMATIC PCS neo is a distributed control system (DCS). The SINUMERIK integrated product suite facilitates simple networking of machine tools in IT in production environments. User Management Component (UMC) is an integrated component that enables system-wide centralized maintenance of users. \n\r\n\r\nThere is an improper input validation vulnerability in Siemens User Management Component (UMC)",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-46285"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-019619"
},
{
"db": "CNVD",
"id": "CNVD-2023-97279"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-46285",
"trust": 3.2
},
{
"db": "SIEMENS",
"id": "SSA-999588",
"trust": 2.4
},
{
"db": "ICS CERT",
"id": "ICSA-23-348-03",
"trust": 0.8
},
{
"db": "JVN",
"id": "JVNVU98271228",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2023-019619",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2023-97279",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-97279"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-019619"
},
{
"db": "NVD",
"id": "CVE-2023-46285"
}
]
},
"id": "VAR-202312-0238",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-97279"
}
],
"trust": 1.2076923
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-97279"
}
]
},
"last_update_date": "2024-05-14T19:25:50.562000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Siemens User Management Component (UMC) Improper Input Validation Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/500461"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-97279"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "NVD-CWE-noinfo",
"trust": 1.0
},
{
"problemtype": "Lack of information (CWE-noinfo) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-019619"
},
{
"db": "NVD",
"id": "CVE-2023-46285"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf"
},
{
"trust": 1.6,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-999588.html"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu98271228/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-46285"
},
{
"trust": 0.8,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-348-03"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-97279"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-019619"
},
{
"db": "NVD",
"id": "CVE-2023-46285"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2023-97279"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-019619"
},
{
"db": "NVD",
"id": "CVE-2023-46285"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-12-15T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-97279"
},
{
"date": "2024-01-15T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-019619"
},
{
"date": "2023-12-12T12:15:14.477000",
"db": "NVD",
"id": "CVE-2023-46285"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-12-13T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-97279"
},
{
"date": "2024-01-15T02:22:00",
"db": "JVNDB",
"id": "JVNDB-2023-019619"
},
{
"date": "2024-05-14T16:15:45.917000",
"db": "NVD",
"id": "CVE-2023-46285"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Vulnerabilities in multiple Siemens products",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-019619"
}
],
"trust": 0.8
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.