var-202402-1389
Vulnerability from variot
A vulnerability has been identified in OpenPCS 7 V9.1 (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC WinCC Runtime Professional V18 (All versions), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions < V8.0 Update 4). The implementation of the RPC (Remote Procedure call) communication protocol in the affected products do not properly handle certain malformed RPC messages. An attacker could use this vulnerability to cause a denial of service condition in the RPC server. SIMATIC PCS 7 is a distributed control system (DCS) that integrates SIMATIC WinCC, SIMATIC Batch, SIMATIC Route control, OpenPCS 7 and other components. SIMATIC WinCC is a supervisory control and data acquisition (SCADA) system. SIMATIC WinCC Runtime Professional is a visual runtime platform for operator control and monitoring of machines and plants
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202402-1389", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic wincc", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v7.4" }, { "model": "simatic pcs", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "7v9.1" }, { "model": "openpcs", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "79.1" }, { "model": "simatic batch", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "9.1" }, { "model": "simatic route control", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "9.1" }, { "model": "simatic wincc runtime professional", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v18" }, { "model": "simatic wincc runtime professional", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v19" }, { "model": "simatic wincc sp2 update", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "7.515" }, { "model": "simatic wincc sp4", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "8.0" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-09314" } ] }, "cve": "CVE-2023-48364", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 6.1, "confidentialityImpact": "NONE", "exploitabilityScore": 6.5, "id": "CNVD-2024-09314", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "productcert@siemens.com", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "exploitabilityScore": 2.8, "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } ], "severity": [ { "author": "productcert@siemens.com", "id": "CVE-2023-48364", "trust": 1.0, "value": "MEDIUM" }, { "author": "CNVD", "id": "CNVD-2024-09314", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-09314" }, { "db": "NVD", "id": "CVE-2023-48364" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in OpenPCS 7 V9.1 (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC WinCC Runtime Professional V18 (All versions), SIMATIC WinCC Runtime Professional V19 (All versions \u003c V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions \u003c V8.0 Update 4). The implementation of the RPC (Remote Procedure call) communication protocol in the affected products do not properly handle certain malformed RPC messages. An attacker could use this vulnerability to cause a denial of service condition in the RPC server. SIMATIC PCS 7 is a distributed control system (DCS) that integrates SIMATIC WinCC, SIMATIC Batch, SIMATIC Route control, OpenPCS 7 and other components. SIMATIC WinCC is a supervisory control and data acquisition (SCADA) system. SIMATIC WinCC Runtime Professional is a visual runtime platform for operator control and monitoring of machines and plants", "sources": [ { "db": "NVD", "id": "CVE-2023-48364" }, { "db": "CNVD", "id": "CNVD-2024-09314" }, { "db": "VULMON", "id": "CVE-2023-48364" } ], "trust": 1.53 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-48364", "trust": 1.7 }, { "db": "SIEMENS", "id": "SSA-753746", "trust": 1.7 }, { "db": "CNVD", "id": "CNVD-2024-09314", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-24-046-12", "trust": 0.1 }, { "db": "VULMON", "id": "CVE-2023-48364", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-09314" }, { "db": "VULMON", "id": "CVE-2023-48364" }, { "db": "NVD", "id": "CVE-2023-48364" } ] }, "id": "VAR-202402-1389", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-09314" } ], "trust": 1.2508139042857143 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-09314" } ] }, "last_update_date": "2024-06-11T23:02:19.962000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Null pointer dereference vulnerability (CNVD-2024-09314) in multiple Siemens products", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/526516" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-09314" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-476", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2023-48364" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/html/ssa-753746.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-046-12" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-09314" }, { "db": "VULMON", "id": "CVE-2023-48364" }, { "db": "NVD", "id": "CVE-2023-48364" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-09314" }, { "db": "VULMON", "id": "CVE-2023-48364" }, { "db": "NVD", "id": "CVE-2023-48364" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-02-23T00:00:00", "db": "CNVD", "id": "CNVD-2024-09314" }, { "date": "2024-02-13T00:00:00", "db": "VULMON", "id": "CVE-2023-48364" }, { "date": "2024-02-13T09:15:45.980000", "db": "NVD", "id": "CVE-2023-48364" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-02-21T00:00:00", "db": "CNVD", "id": "CNVD-2024-09314" }, { "date": "2024-02-13T00:00:00", "db": "VULMON", "id": "CVE-2023-48364" }, { "date": "2024-06-11T12:15:13.600000", "db": "NVD", "id": "CVE-2023-48364" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Null pointer dereference vulnerability (CNVD-2024-09314) in multiple Siemens products", "sources": [ { "db": "CNVD", "id": "CNVD-2024-09314" } ], "trust": 0.6 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.