VAR-202402-1997

Vulnerability from variot - Updated: 2024-03-27 22:40

An issue was discovered in gui/util/qktxhandler.cpp in Qt before 5.15.17, 6.x before 6.2.12, 6.3.x through 6.5.x before 6.5.5, and 6.6.x before 6.6.2. A buffer overflow and application crash can occur via a crafted KTX image file. Tenda AC18 is a router made by the Chinese company Tenda.

There is a buffer overflow vulnerability in Tenda AC18 V15.03.05.05. The vulnerability is caused by the cmdinput parameter of the formexeCommand function in the /goform/execCommand file failing to correctly verify the length of the input data. A remote attacker can exploit this vulnerability to execute on the system. Arbitrary code or lead to denial of service attacks. DescriptionA flaw was found in Qt Base. This flaw allows an malicious user to use a specially crafted KTX image file to trigger a buffer overflow in the application reading it, leading to a denial of service.A flaw was found in Qt Base

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202402-1997",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac18",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "15.03.05.05"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      }
    ]
  },
  "cve": "CVE-2024-25580",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2024-14308",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [],
        "severity": [
          {
            "author": "CNVD",
            "id": "CNVD-2024-14308",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered in gui/util/qktxhandler.cpp in Qt before 5.15.17, 6.x before 6.2.12, 6.3.x through 6.5.x before 6.5.5, and 6.6.x before 6.6.2. A buffer overflow and application crash can occur via a crafted KTX image file. Tenda AC18 is a router made by the Chinese company Tenda. \n\r\n\r\nThere is a buffer overflow vulnerability in Tenda AC18 V15.03.05.05. The vulnerability is caused by the cmdinput parameter of the formexeCommand function in the /goform/execCommand file failing to correctly verify the length of the input data. A remote attacker can exploit this vulnerability to execute on the system. Arbitrary code or lead to denial of service attacks. Description\u003c!----\u003eA flaw was found in Qt Base. This flaw allows an malicious user to use a specially crafted KTX image file to trigger a buffer overflow in the application reading it, leading to a denial of service.A flaw was found in Qt Base",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-25580"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      },
      {
        "db": "VULMON",
        "id": "CVE-2024-25580"
      }
    ],
    "trust": 1.53
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-25580",
        "trust": 1.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2024-25580",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      },
      {
        "db": "VULMON",
        "id": "CVE-2024-25580"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-25580"
      }
    ]
  },
  "id": "VAR-202402-1997",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      }
    ],
    "trust": 1.00125
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      }
    ]
  },
  "last_update_date": "2024-03-27T22:40:17.658000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Tenda AC18 formexeCommand function buffer overflow vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/534891"
      },
      {
        "title": "Debian CVElist Bug Report Logs: qt6-base: CVE-2024-25580",
        "trust": 0.1,
        "url": "https://vulmon.com/vendoradvisory?qidtp=debian_cvelist_bugreportlogs\u0026qid=2ebf1524fcece0a7b0c6937e8d2445fe"
      },
      {
        "title": "Red Hat: ",
        "trust": 0.1,
        "url": "https://vulmon.com/vendoradvisory?qidtp=red_hat_cve_database\u0026qid=cve-2024-25580"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      },
      {
        "db": "VULMON",
        "id": "CVE-2024-25580"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.0,
        "url": "https://www.qt.io/blog/security-advisory-potential-buffer-overflow-when-reading-ktx-images"
      },
      {
        "trust": 0.7,
        "url": "https://access.redhat.com/security/cve/cve-2024-25580"
      },
      {
        "trust": 0.1,
        "url": "https://bugs.debian.org/cgi-bin/bugreport.cgi?bug=1064052"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      },
      {
        "db": "VULMON",
        "id": "CVE-2024-25580"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-25580"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      },
      {
        "db": "VULMON",
        "id": "CVE-2024-25580"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-25580"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-03-21T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      },
      {
        "date": "2024-03-27T03:15:12.007000",
        "db": "NVD",
        "id": "CVE-2024-25580"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-03-21T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      },
      {
        "date": "2024-03-27T12:29:30.307000",
        "db": "NVD",
        "id": "CVE-2024-25580"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC18 formexeCommand function buffer overflow vulnerability",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-14308"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…