Common Weakness Enumeration

CWE-306

Allowed

Missing Authentication for Critical Function

Abstraction: Base · Status: Draft

The product does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources.

3492 vulnerabilities reference this CWE, most recent first.

CVE-2024-9137 (GCVE-0-2024-9137)

Vulnerability from cvelistv5 – Published: 2024-10-14 08:09 – Updated: 2025-09-19 08:08
VLAI
Title
Moxa Service Missing Authentication for Critical Function
Summary
The affected product lacks an authentication check when sending commands to the server via the Moxa service. This vulnerability allows an attacker to execute specified commands, potentially leading to unauthorized downloads or uploads of configuration files and system compromise.
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-306 - Missing Authentication for Critical Function
Assigner
Impacted products
Vendor Product Version
Moxa EDR-8010 Series Affected: 1.0 , ≤ 3.12.1 (custom)
Create a notification for this product.
Moxa EDR-G9004 Series Affected: 1.0 , ≤ 3.12.1 (custom)
Create a notification for this product.
Moxa EDR-G9010 Series Affected: 1.0 , ≤ 3.12.1 (custom)
Create a notification for this product.
Moxa EDF-G1002-BP Series Affected: 1.0 , ≤ 3.12.1 (custom)
Create a notification for this product.
Moxa NAT-102 Series Affected: 1.0 , ≤ 1.0.5 (custom)
Create a notification for this product.
Moxa OnCell G4302-LTE4 Series Affected: 1.0 , ≤ 3.9 (custom)
Create a notification for this product.
Moxa TN-4900 Series Affected: 1.0 , ≤ 3.6 (custom)
Create a notification for this product.
Moxa EDS-608 Series Affected: 1.0 , ≤ 3.12 (custom)
Create a notification for this product.
Moxa EDS-611 Series Affected: 1.0 , ≤ 3.12 (custom)
Create a notification for this product.
Moxa EDS-616 Series Affected: 1.0 , ≤ 3.12 (custom)
Create a notification for this product.
Moxa EDS-619 Series Affected: 1.0 , ≤ 3.12 (custom)
Create a notification for this product.
Moxa EDS-405A Series Affected: 1.0 , ≤ 3.14 (custom)
Unaffected: 3.14.4 (custom)
Create a notification for this product.
Moxa EDS-408A Series Affected: 1.0 , ≤ 3.12 (custom)
Unaffected: 3.14.6 (custom)
Create a notification for this product.
Moxa EDS-505A Series Affected: 1.0 , ≤ 3.11 (custom)
Create a notification for this product.
Moxa EDS-508A Series Affected: 1.0 , ≤ 3.11 (custom)
Create a notification for this product.
Moxa EDS-510A Series Affected: 1.0 , ≤ 3.12 (custom)
Create a notification for this product.
Moxa EDS-516A Series Affected: 1.0 , ≤ 3.11 (custom)
Create a notification for this product.
Moxa EDS-518A Series Affected: 1.0 , ≤ 3.11 (custom)
Create a notification for this product.
Moxa EDS-G509 Series Affected: 1.0 , ≤ 3.10 (custom)
Create a notification for this product.
Moxa EDS-P510 Series Affected: 1.0 , ≤ 3.11 (custom)
Create a notification for this product.
Moxa EDS-P510A Series Affected: 1.0 , ≤ 3.11 (custom)
Create a notification for this product.
Moxa EDS-510E Series Affected: 1.0 , ≤ 5.5 (custom)
Create a notification for this product.
Moxa EDS-518E Series Affected: 1.0 , ≤ 6.3 (custom)
Create a notification for this product.
Moxa EDS-528E Series Affected: 1.0 , ≤ 6.3 (custom)
Create a notification for this product.
Moxa EDS-G508E Series Affected: 1.0 , ≤ 6.4 (custom)
Create a notification for this product.
Moxa EDS-G512E Series Affected: 1.0 , ≤ 6.4 (custom)
Create a notification for this product.
Moxa EDS-G516E Series Affected: 1.0 , ≤ 6.4 (custom)
Create a notification for this product.
Moxa EDS-P506E Series Affected: 1.0 , ≤ 5.8 (custom)
Create a notification for this product.
Moxa ICS-G7526A Series Affected: 1.0 , ≤ 5.10 (custom)
Create a notification for this product.
Moxa ICS-G7528A Series Affected: 1.0 , ≤ 5.10 (custom)
Create a notification for this product.
Moxa ICS-G7748A Series Affected: 1.0 , ≤ 5.9 (custom)
Create a notification for this product.
Moxa ICS-G7750A Series Affected: 1.0 , ≤ 5.9 (custom)
Create a notification for this product.
Moxa ICS-G7752A Series Affected: 1.0 , ≤ 5.9 (custom)
Create a notification for this product.
Moxa ICS-G7826A Series Affected: 1.0 , ≤ 5.10 (custom)
Create a notification for this product.
Moxa ICS-G7828A Series Affected: 1.0 , ≤ 5.10 (custom)
Create a notification for this product.
Moxa ICS-G7848A Series Affected: 1.0 , ≤ 5.9 (custom)
Create a notification for this product.
Moxa ICS-G7850A Series Affected: 1.0 , ≤ 5.9 (custom)
Create a notification for this product.
Moxa ICS-G7852A Series Affected: 1.0 , ≤ 5.9 (custom)
Create a notification for this product.
Moxa IKS-G6524A Series Affected: 1.0 , ≤ 5.10 (custom)
Create a notification for this product.
Moxa IKS-6726A Series Affected: 1.0 , ≤ 5.9 (custom)
Create a notification for this product.
Moxa IKS-6728A Series Affected: 1.0 , ≤ 5.9 (custom)
Create a notification for this product.
Moxa IKS-G6824A Series Affected: 1.0 , ≤ 5.10 (custom)
Create a notification for this product.
Moxa SDS-3006 Series Affected: 1.0 , ≤ 3.0 (custom)
Create a notification for this product.
Moxa SDS-3008 Series Affected: 1.0 , ≤ 3.0 (custom)
Create a notification for this product.
Moxa SDS-3010 Series Affected: 1.0 , ≤ 3.0 (custom)
Create a notification for this product.
Moxa SDS-3016 Series Affected: 1.0 , ≤ 3.0 (custom)
Create a notification for this product.
Moxa SDS-G3006 Series Affected: 1.0 , ≤ 3.0 (custom)
Create a notification for this product.
Moxa SDS-G3008 Series Affected: 1.0 , ≤ 3.0 (custom)
Create a notification for this product.
Moxa SDS-G3010 Series Affected: 1.0 , ≤ 3.0 (custom)
Create a notification for this product.
Moxa SDS-G3016 Series Affected: 1.0 , ≤ 3.0 (custom)
Create a notification for this product.
Moxa PT-7728 Series Affected: 1.0 , ≤ 3.9 (custom)
Create a notification for this product.
Moxa PT-7828 Series Affected: 1.0 , ≤ 4.0 (custom)
Create a notification for this product.
Moxa PT-G503 Series Affected: 1.0 , ≤ 5.3 (custom)
Create a notification for this product.
Moxa PT-G510 Series Affected: 1.0 , ≤ 6.5 (custom)
Create a notification for this product.
Moxa PT-G7728 Series Affected: 1.0 , ≤ 6.4 (custom)
Create a notification for this product.
Moxa PT-G7828 Series Affected: 1.0 , ≤ 6.4 (custom)
Create a notification for this product.
Moxa TN-4500A Series Affected: 1.0 , ≤ 3.13 (custom)
Create a notification for this product.
Moxa TN-5500A Series Affected: 1.0 , ≤ 3.13 (custom)
Create a notification for this product.
Moxa TN-G4500 Series Affected: 1.0 , ≤ 5.5 (custom)
Create a notification for this product.
Moxa TN-G6500 Series Affected: 1.0 , ≤ 5.5 (custom)
Create a notification for this product.
moxa edr-g9010 Affected: 1.0 , ≤ 3.12.1 (custom)
    cpe:2.3:a:moxa:edr-g9010:*:*:*:*:*:*:*:*
Create a notification for this product.
moxa nat-102 Affected: 1.0 , ≤ 1.0.5 (custom)
    cpe:2.3:a:moxa:nat-102:*:*:*:*:*:*:*:*
Create a notification for this product.
moxa tn-4900 Affected: 1.0 , ≤ 3.6 (custom)
    cpe:2.3:a:moxa:tn-4900:*:*:*:*:*:*:*:*
Create a notification for this product.
moxa oncell_g4302-lte4 Affected: 1.0 , ≤ 3.9 (custom)
    cpe:2.3:a:moxa:oncell_g4302-lte4:*:*:*:*:*:*:*:*
Create a notification for this product.
moxa edf-g1002-bp Affected: 1.0 , ≤ 3.12.1 (custom)
    cpe:2.3:a:moxa:edf-g1002-bp:*:*:*:*:*:*:*:*
Create a notification for this product.
moxa edr-g9004 Affected: 1.0 , ≤ 3.12.1 (custom)
    cpe:2.3:a:moxa:edr-g9004:*:*:*:*:*:*:*:*
Create a notification for this product.
moxa edr-8010 Affected: 1.0 , ≤ 3.12.1 (custom)
    cpe:2.3:a:moxa:edr-8010:*:*:*:*:*:*:*:*
Create a notification for this product.
Date Public
2024-10-14 08:07
Credits
Lars Haulin
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:moxa:edr-g9010:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "edr-g9010",
            "vendor": "moxa",
            "versions": [
              {
                "lessThanOrEqual": "3.12.1",
                "status": "affected",
                "version": "1.0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:moxa:nat-102:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "nat-102",
            "vendor": "moxa",
            "versions": [
              {
                "lessThanOrEqual": "1.0.5",
                "status": "affected",
                "version": "1.0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:moxa:tn-4900:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "tn-4900",
            "vendor": "moxa",
            "versions": [
              {
                "lessThanOrEqual": "3.6",
                "status": "affected",
                "version": "1.0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:moxa:oncell_g4302-lte4:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "oncell_g4302-lte4",
            "vendor": "moxa",
            "versions": [
              {
                "lessThanOrEqual": "3.9",
                "status": "affected",
                "version": "1.0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:moxa:edf-g1002-bp:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "edf-g1002-bp",
            "vendor": "moxa",
            "versions": [
              {
                "lessThanOrEqual": "3.12.1",
                "status": "affected",
                "version": "1.0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:moxa:edr-g9004:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "edr-g9004",
            "vendor": "moxa",
            "versions": [
              {
                "lessThanOrEqual": "3.12.1",
                "status": "affected",
                "version": "1.0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:moxa:edr-8010:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "edr-8010",
            "vendor": "moxa",
            "versions": [
              {
                "lessThanOrEqual": "3.12.1",
                "status": "affected",
                "version": "1.0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-9137",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-14T15:27:27.483068Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-15T14:32:26.853Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "EDR-8010 Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "3.12.1",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EDR-G9004 Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "3.12.1",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EDR-G9010 Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "3.12.1",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EDF-G1002-BP Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "3.12.1",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "NAT-102 Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "1.0.5",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "OnCell G4302-LTE4 Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "3.9",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TN-4900 Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "3.6",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EDS-608 Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "3.12",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EDS-611 Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "3.12",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EDS-616 Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "3.12",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EDS-619 Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "3.12",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EDS-405A Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "3.14",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            },
            {
              "status": "unaffected",
              "version": "3.14.4",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EDS-408A Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "3.12",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            },
            {
              "status": "unaffected",
              "version": "3.14.6",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EDS-505A Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "3.11",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EDS-508A Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "3.11",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EDS-510A Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "3.12",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EDS-516A Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "3.11",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EDS-518A Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "3.11",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EDS-G509 Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "3.10",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EDS-P510 Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "3.11",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EDS-P510A Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "3.11",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EDS-510E Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "5.5",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EDS-518E Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "6.3",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EDS-528E Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "6.3",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EDS-G508E Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "6.4",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EDS-G512E Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "6.4",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EDS-G516E Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "6.4",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EDS-P506E Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "5.8",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ICS-G7526A Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "5.10",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ICS-G7528A Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "5.10",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ICS-G7748A Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "5.9",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ICS-G7750A Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "5.9",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ICS-G7752A Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "5.9",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ICS-G7826A Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "5.10",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ICS-G7828A Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "5.10",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ICS-G7848A Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "5.9",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ICS-G7850A Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "5.9",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ICS-G7852A Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "5.9",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "IKS-G6524A Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "5.10",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "IKS-6726A Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "5.9",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "IKS-6728A Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "5.9",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "IKS-G6824A Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "5.10",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "SDS-3006 Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "3.0",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "SDS-3008 Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "3.0",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "SDS-3010 Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "3.0",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "SDS-3016 Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "3.0",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "SDS-G3006 Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "3.0",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "SDS-G3008 Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "3.0",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "SDS-G3010 Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "3.0",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "SDS-G3016 Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "3.0",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PT-7728 Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "3.9",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PT-7828 Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "4.0",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PT-G503 Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "5.3",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PT-G510 Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "6.5",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PT-G7728 Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "6.4",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PT-G7828 Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "6.4",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TN-4500A Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "3.13",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TN-5500A Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "3.13",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TN-G4500 Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "5.5",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TN-G6500 Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "5.5",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Lars Haulin"
        }
      ],
      "datePublic": "2024-10-14T08:07:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eThe affected product lacks an authentication check when sending commands to the server via the Moxa service. This vulnerability allows an attacker to execute specified commands, potentially leading to unauthorized downloads or uploads of configuration files and system compromise.\u003c/p\u003e"
            }
          ],
          "value": "The affected product lacks an authentication check when sending commands to the server via the Moxa service. This vulnerability allows an attacker to execute specified commands, potentially leading to unauthorized downloads or uploads of configuration files and system compromise."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-216",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-216 Communication Channel Manipulation"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.4,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-19T08:08:52.357Z",
        "orgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
        "shortName": "Moxa"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-241154-missing-authentication-and-os-command-injection-vulnerabilities-in-routers-and-network-security-appliances"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-241156-cve-2024-9137-missing-authentication-vulnerability-in-ethernet-switches"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Please refer to the security advisories:\u003cbr\u003e\u003cul\u003e\u003cli\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.moxa.com/en/support/product-support/security-advisory/mpsa-241154-missing-authentication-and-os-command-injection-vulnerabilities-in-routers-and-network-security-appliances\"\u003eMissing Authentication and OS Command Injection Vulnerabilities in Cellular Routers, Secure Routers, and Network Security Appliances\u003c/a\u003e\u003cbr\u003e\u003c/li\u003e\u003cli\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.moxa.com/en/support/product-support/security-advisory/mpsa-241156-cve-2024-9137-missing-authentication-vulnerability-in-ethernet-switches\"\u003eCVE-2024-9137: Missing Authentication Vulnerability in Ethernet Switches\u003c/a\u003e\u003cbr\u003e\u003c/li\u003e\u003c/ul\u003e"
            }
          ],
          "value": "Please refer to the security advisories:\n  *   Missing Authentication and OS Command Injection Vulnerabilities in Cellular Routers, Secure Routers, and Network Security Appliances https://www.moxa.com/en/support/product-support/security-advisory/mpsa-241154-missing-authentication-and-os-command-injection-vulnerabilities-in-routers-and-network-security-appliances \n\n  *   CVE-2024-9137: Missing Authentication Vulnerability in Ethernet Switches https://www.moxa.com/en/support/product-support/security-advisory/mpsa-241156-cve-2024-9137-missing-authentication-vulnerability-in-ethernet-switches"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Moxa Service Missing Authentication for Critical Function",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eTo mitigate the risks associated with this vulnerability, we recommend the following actions:\u003c/p\u003e\u003cul\u003e\u003cli\u003eDisable Moxa Service and Moxa Service (Encrypted) temporarily if they are not required for operations. This will minimize potential attack vectors until a patch or updated firmware is applied.\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eRefer to the \u003cem\u003eGeneral Security Best Practices\u003c/em\u003e\u0026nbsp;section to further strengthen your security posture.\u003c/p\u003e"
            }
          ],
          "value": "To mitigate the risks associated with this vulnerability, we recommend the following actions:\n\n  *  Disable Moxa Service and Moxa Service (Encrypted) temporarily if they are not required for operations. This will minimize potential attack vectors until a patch or updated firmware is applied.\n\n\nRefer to the General Security Best Practices\u00a0section to further strengthen your security posture."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
    "assignerShortName": "Moxa",
    "cveId": "CVE-2024-9137",
    "datePublished": "2024-10-14T08:09:22.689Z",
    "dateReserved": "2024-09-24T07:11:35.456Z",
    "dateUpdated": "2025-09-19T08:08:52.357Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-9062 (GCVE-0-2024-9062)

Vulnerability from cvelistv5 – Published: 2025-06-10 23:25 – Updated: 2025-06-11 13:41
VLAI
Title
macOS Archify: Local Privilege Escalation
Summary
The Archify application contains a local privilege escalation vulnerability due to insufficient client validation in its privileged helper tool, com.oct4pie.archifyhelper, which is exposed via XPC. Archify follows the "factored applications" model, delegating privileged operations—such as arbitrary file deletion and file permission changes—to this helper running as root. However, the helper does not verify the code signature, entitlements, or signing flags of the connecting client. Although macOS provides secure validation mechanisms like auditToken, these are not implemented. As a result, any local process can establish a connection to the helper and invoke privileged functionality, leading to unauthorized execution of actions with root-level privileges.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-306 - Missing Authentication for Critical Function
Assigner
Impacted products
Vendor Product Version
Archify Archify Affected: 0 , ≤ 1.3.1 (semver)
Create a notification for this product.
Credits
Carlos Garrido of Pentraze Cybersecurity
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-9062",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-11T13:41:01.210655Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-11T13:41:12.653Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "packageName": "com.oct4pie.archifyhelper",
          "platforms": [
            "MacOS"
          ],
          "product": "Archify",
          "repo": "https://github.com/Oct4Pie/archify",
          "vendor": "Archify",
          "versions": [
            {
              "lessThanOrEqual": "1.3.1",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Carlos Garrido of Pentraze Cybersecurity"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The Archify application contains a local privilege escalation vulnerability due to insufficient client validation in its privileged helper tool, com.oct4pie.archifyhelper, which is exposed via XPC. Archify follows the \"factored applications\" model, delegating privileged operations\u2014such as arbitrary file deletion and file permission changes\u2014to this helper running as root. However, the helper does not verify the code signature, entitlements, or signing flags of the connecting client. Although macOS provides secure validation mechanisms like auditToken, these are not implemented. As a result, any local process can establish a connection to the helper and invoke privileged functionality, leading to unauthorized execution of actions with root-level privileges."
            }
          ],
          "value": "The Archify application contains a local privilege escalation vulnerability due to insufficient client validation in its privileged helper tool, com.oct4pie.archifyhelper, which is exposed via XPC. Archify follows the \"factored applications\" model, delegating privileged operations\u2014such as arbitrary file deletion and file permission changes\u2014to this helper running as root. However, the helper does not verify the code signature, entitlements, or signing flags of the connecting client. Although macOS provides secure validation mechanisms like auditToken, these are not implemented. As a result, any local process can establish a connection to the helper and invoke privileged functionality, leading to unauthorized execution of actions with root-level privileges."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-233",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-233 Privilege Escalation"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-10T23:25:30.420Z",
        "orgId": "41c37e40-543d-43a2-b660-2fee83ea851a",
        "shortName": "Pentraze"
      },
      "references": [
        {
          "url": "https://pentraze.com/"
        },
        {
          "url": "https://pentraze.com/vulnerability-reports/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "macOS Archify: Local Privilege Escalation",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "41c37e40-543d-43a2-b660-2fee83ea851a",
    "assignerShortName": "Pentraze",
    "cveId": "CVE-2024-9062",
    "datePublished": "2025-06-10T23:25:30.420Z",
    "dateReserved": "2024-09-20T21:49:17.091Z",
    "dateUpdated": "2025-06-11T13:41:12.653Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-8956 (GCVE-0-2024-8956)

Vulnerability from cvelistv5 – Published: 2024-09-17 19:59 – Updated: 2025-11-22 12:09 X_Known Exploited Vulnerability
VLAI
Title
PTZOptics NDI and SDI Cameras /cgi-bin/param.cgi Insufficient Authentication
Summary
PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an insufficient authentication issue. The camera does not properly enforce authentication to /cgi-bin/param.cgi when requests are sent without an HTTP Authorization header. The result is a remote and unauthenticated attacker can leak sensitive data such as usernames, password hashes, and configurations details. Additionally, the attacker can update individual configuration values or overwrite the whole file.
SSVC
Exploitation: active Automatable: yes Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-306 - Missing Authentication for Critical Function
Assigner
References
Impacted products
Vendor Product Version
PTZOptics PT30X-SDI Affected: 0 , < 6.3.40 (semver)
Create a notification for this product.
PTZOptics PT30X-NDI Affected: 0 , < 6.3.40 (semver)
Create a notification for this product.
ptzoptics pt30x-sdi_firmware Affected: 0 , < 6.3.40 (custom)
    cpe:2.3:o:ptzoptics:pt30x-sdi_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
ptzoptics pt30x-ndi-xx-g2_firmware Affected: 0 , < 6.3.40 (custom)
    cpe:2.3:o:ptzoptics:pt30x-ndi-xx-g2_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
Konstantin Lazarev of GreyNoise
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:ptzoptics:pt30x-sdi_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "pt30x-sdi_firmware",
            "vendor": "ptzoptics",
            "versions": [
              {
                "lessThan": "6.3.40",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:ptzoptics:pt30x-ndi-xx-g2_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "pt30x-ndi-xx-g2_firmware",
            "vendor": "ptzoptics",
            "versions": [
              {
                "lessThan": "6.3.40",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-8956",
                "options": [
                  {
                    "Exploitation": "active"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-08T15:54:06.883084Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          },
          {
            "other": {
              "content": {
                "dateAdded": "2024-11-04",
                "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2024-8956"
              },
              "type": "kev"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-21T22:55:44.402Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "technical-description",
              "third-party-advisory",
              "exploit"
            ],
            "url": "https://www.labs.greynoise.io/grimoire/2024-10-31-sift-0-day-rce/"
          },
          {
            "tags": [
              "third-party-advisory"
            ],
            "url": "https://www.greynoise.io/blog/greynoise-intelligence-discovers-zero-day-vulnerabilities-in-live-streaming-cameras-with-the-help-of-ai"
          },
          {
            "tags": [
              "government-resource"
            ],
            "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2024-8956"
          }
        ],
        "timeline": [
          {
            "lang": "en",
            "time": "2024-11-04T00:00:00.000Z",
            "value": "CVE-2024-8956 added to CISA KEV"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PT30X-SDI",
          "vendor": "PTZOptics",
          "versions": [
            {
              "lessThan": "6.3.40",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PT30X-NDI",
          "vendor": "PTZOptics",
          "versions": [
            {
              "lessThan": "6.3.40",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:ptzoptics:pt30x-sdi:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "6.3.40",
                  "versionStartIncluding": "0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "OR"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:ptzoptics:pt30x-ndi-xx-g2:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "6.3.40",
                  "versionStartIncluding": "0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "OR"
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Konstantin Lazarev of GreyNoise"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an insufficient authentication issue. The camera does not properly enforce authentication to /cgi-bin/param.cgi when requests are sent without an HTTP Authorization header. The result is a remote and unauthenticated attacker can leak sensitive data such as usernames, password hashes, and configurations details. Additionally, the attacker can update individual configuration values or overwrite the whole file.\u003cbr\u003e"
            }
          ],
          "value": "PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an insufficient authentication issue. The camera does not properly enforce authentication to /cgi-bin/param.cgi when requests are sent without an HTTP Authorization header. The result is a remote and unauthenticated attacker can leak sensitive data such as usernames, password hashes, and configurations details. Additionally, the attacker can update individual configuration values or overwrite the whole file."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-114",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-114 Authentication Abuse"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-22T12:09:58.681Z",
        "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "shortName": "VulnCheck"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://ptzoptics.com/firmware-changelog/"
        },
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vulncheck.com/advisories/ptzoptics-insufficient-auth"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "tags": [
        "x_known-exploited-vulnerability"
      ],
      "title": "PTZOptics NDI and SDI Cameras /cgi-bin/param.cgi Insufficient Authentication",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
    "assignerShortName": "VulnCheck",
    "cveId": "CVE-2024-8956",
    "datePublished": "2024-09-17T19:59:27.205Z",
    "dateReserved": "2024-09-17T19:08:47.005Z",
    "dateUpdated": "2025-11-22T12:09:58.681Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2024-8751 (GCVE-0-2024-8751)

Vulnerability from cvelistv5 – Published: 2024-09-12 21:38 – Updated: 2026-07-16 09:48
VLAI
Title
CVE-2024-8751
Summary
A vulnerability allows a remote unauthenticated attacker to modify the prod uct’s IP address over the Sopas ET interface. This can lead to a Denial of Service attack.
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-306 - Missing Authentication for Critical Function
Assigner
Impacted products
Vendor Product Version
Endress+Hauser MSC800 Affected: V1.0 , ≤ <=V4.25 (custom)
Affected: S1.0 , ≤ <=S2.93.19 (custom)
Create a notification for this product.
Endress+Hauser MARSIC200 Affected: all versions (custom)
Create a notification for this product.
Endress+Hauser MARSIC280 Affected: all versions (custom)
Create a notification for this product.
Endress+Hauser MARSIC300 Affected: all versions (custom)
Create a notification for this product.
Endress+Hauser MCS100FT Affected: all versions (custom)
Create a notification for this product.
Endress+Hauser MCS200HW Affected: all versions (custom)
Create a notification for this product.
Endress+Hauser MCS300P Affected: all versions (custom)
Create a notification for this product.
Endress+Hauser MERCEM300Z Affected: all versions (custom)
Create a notification for this product.
Endress+Hauser SAM800 Affected: all versions (custom)
Create a notification for this product.
Endress+Hauser SIPROCESS Affected: all versions (custom)
Create a notification for this product.
Endress+Hauser GMS800 Affected: all versions (custom)
Create a notification for this product.
Endress+Hauser GMS800 FIDOR Affected: all versions (custom)
Create a notification for this product.
Endress+Hauser GM32 Affected: all versions (custom)
Create a notification for this product.
Endress+Hauser VICOTEC320 Affected: all versions (custom)
Create a notification for this product.
Endress+Hauser MCU ETH-Service and Modbus-TCP Module Affected: all versions (custom)
Create a notification for this product.
Endress+Hauser FLPS Affected: all versions (custom)
Create a notification for this product.
Endress+Hauser MES1B B&B Converter Affected: all versions (custom)
Create a notification for this product.
sick msc800_firmware Affected: 1.0 , ≤ 4.25 (custom)
Affected: 1.0 , ≤ s2.93.19 (custom)
    cpe:2.3:o:sick:msc800_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Date Public
2024-09-12 21:33
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:sick:msc800_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "msc800_firmware",
            "vendor": "sick",
            "versions": [
              {
                "lessThanOrEqual": "4.25",
                "status": "affected",
                "version": "1.0",
                "versionType": "custom"
              },
              {
                "lessThanOrEqual": "s2.93.19",
                "status": "affected",
                "version": "1.0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-8751",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-13T13:53:13.856056Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-13T14:02:19.375Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "MSC800",
          "vendor": "Endress+Hauser",
          "versions": [
            {
              "lessThanOrEqual": "\u003c=V4.25",
              "status": "affected",
              "version": "V1.0",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "\u003c=S2.93.19",
              "status": "affected",
              "version": "S1.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "MARSIC200",
          "vendor": "Endress+Hauser",
          "versions": [
            {
              "status": "affected",
              "version": "all versions",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "MARSIC280",
          "vendor": "Endress+Hauser",
          "versions": [
            {
              "status": "affected",
              "version": "all versions",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "MARSIC300",
          "vendor": "Endress+Hauser",
          "versions": [
            {
              "status": "affected",
              "version": "all versions",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "MCS100FT",
          "vendor": "Endress+Hauser",
          "versions": [
            {
              "status": "affected",
              "version": "all versions",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "MCS200HW",
          "vendor": "Endress+Hauser",
          "versions": [
            {
              "status": "affected",
              "version": "all versions",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "MCS300P",
          "vendor": "Endress+Hauser",
          "versions": [
            {
              "status": "affected",
              "version": "all versions",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "MERCEM300Z",
          "vendor": "Endress+Hauser",
          "versions": [
            {
              "status": "affected",
              "version": "all versions",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "SAM800",
          "vendor": "Endress+Hauser",
          "versions": [
            {
              "status": "affected",
              "version": "all versions",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "SIPROCESS",
          "vendor": "Endress+Hauser",
          "versions": [
            {
              "status": "affected",
              "version": "all versions",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "GMS800",
          "vendor": "Endress+Hauser",
          "versions": [
            {
              "status": "affected",
              "version": "all versions",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "GMS800 FIDOR",
          "vendor": "Endress+Hauser",
          "versions": [
            {
              "status": "affected",
              "version": "all versions",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "GM32",
          "vendor": "Endress+Hauser",
          "versions": [
            {
              "status": "affected",
              "version": "all versions",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "VICOTEC320",
          "vendor": "Endress+Hauser",
          "versions": [
            {
              "status": "affected",
              "version": "all versions",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "MCU ETH-Service and Modbus-TCP Module",
          "vendor": "Endress+Hauser",
          "versions": [
            {
              "status": "affected",
              "version": "all versions",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "FLPS",
          "vendor": "Endress+Hauser",
          "versions": [
            {
              "status": "affected",
              "version": "all versions",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "MES1B B\u0026B Converter",
          "vendor": "Endress+Hauser",
          "versions": [
            {
              "status": "affected",
              "version": "all versions",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2024-09-12T21:33:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A vulnerability allows a remote unauthenticated attacker to modify the prod\nuct\u2019s IP address over the Sopas ET interface. This can lead to a Denial of Service attack.\u0026nbsp;\u003cbr\u003e"
            }
          ],
          "value": "A vulnerability allows a remote unauthenticated attacker to modify the prod\nuct\u2019s IP address over the Sopas ET interface. This can lead to a Denial of Service attack."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-07-16T09:48:36.996Z",
        "orgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
        "shortName": "SICK AG"
      },
      "references": [
        {
          "tags": [
            "x_SICK PSIRT Website"
          ],
          "url": "https://sick.com/psirt"
        },
        {
          "tags": [
            "x_SICK Operating Guidelines"
          ],
          "url": "https://cdn.sick.com/media/docs/1/11/411/Special_information_CYBERSECURITY_BY_SICK_en_IM0084411.PDF"
        },
        {
          "tags": [
            "x_ICS-CERT recommended practices on Industrial Security"
          ],
          "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
        },
        {
          "tags": [
            "x_CVSS v3.1 Calculator"
          ],
          "url": "https://www.first.org/cvss/calculator/3.1"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.sick.com/.well-known/csaf/white/2024/sca-2024-0002.pdf"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.sick.com/.well-known/csaf/white/2026/sca-2026-0009.pdf"
        },
        {
          "tags": [
            "x_The canonical URL"
          ],
          "url": "https://www.sick.com/.well-known/csaf/white/2024/sca-2024-0002.json"
        },
        {
          "tags": [
            "x_The canonical URL"
          ],
          "url": "https://www.sick.com/.well-known/csaf/white/2026/sca-2026-0009.json"
        },
        {
          "tags": [
            "x_Endress+Hauser"
          ],
          "url": "https://www.endress.com"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "For Endress+Hauser MSC800FT: Customers who use the version \u0026lt;=V4.25 are strongly recommended to upgrade to the latest\nrelease V4.26\n\n\u003cbr\u003e"
            }
          ],
          "value": "For Endress+Hauser MSC800FT: Customers who use the version \u003c=V4.25 are strongly recommended to upgrade to the latest\nrelease V4.26"
        },
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "For Endress+Hauser MSC800FT: Customers who use the version \u0026lt;=S2.93.19 are strongly recommended to upgrade to the\nlatest release S2.93.20.\n\n\u003cbr\u003e"
            }
          ],
          "value": "For Endress+Hauser MSC800FT: Customers who use the version \u003c=S2.93.19 are strongly recommended to upgrade to the\nlatest release S2.93.20."
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "timeline": [
        {
          "lang": "en",
          "time": "2024-09-12T21:36:00.000Z",
          "value": "1: Initial version"
        },
        {
          "lang": "en",
          "time": "2026-07-16T10:00:00.000Z",
          "value": "2: Added more products"
        }
      ],
      "title": "CVE-2024-8751",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eFor Endress+Hauser\u0026nbsp;MARSIC200, MARSIC280, MARSIC300, MCS100FT, MCS200HW, MCS300P, MERCEM300Z, SAM800, SIPROCESS, GMS800, GMS800 FIDOR, GM32, VICOTEC320, MCU ETH-Service and Modbus-TCP Module, FLPS, MES1B B\u0026amp;B Converter:\u0026nbsp; Please make sure that only trusted entities have access to the device. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The \u201dICS-CERT recommended practices on Industrial Security\u201d could help to implement the general security practices.\u003c/p\u003e"
            }
          ],
          "value": "For Endress+Hauser\u00a0MARSIC200, MARSIC280, MARSIC300, MCS100FT, MCS200HW, MCS300P, MERCEM300Z, SAM800, SIPROCESS, GMS800, GMS800 FIDOR, GM32, VICOTEC320, MCU ETH-Service and Modbus-TCP Module, FLPS, MES1B B\u0026B Converter:\u00a0 Please make sure that only trusted entities have access to the device. Furthermore, you should apply the following General Security Measures when operating the product to mitigate the associated security risk. The \u201dICS-CERT recommended practices on Industrial Security\u201d could help to implement the general security practices."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
    "assignerShortName": "SICK AG",
    "cveId": "CVE-2024-8751",
    "datePublished": "2024-09-12T21:38:37.516Z",
    "dateReserved": "2024-09-12T13:17:03.176Z",
    "dateUpdated": "2026-07-16T09:48:36.996Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2024-8584 (GCVE-0-2024-8584)

Vulnerability from cvelistv5 – Published: 2024-09-09 02:57 – Updated: 2025-02-21 16:54
VLAI
Title
LEARNING DIGITAL Orca HCM - Missing Authentication
Summary
Orca HCM from LEARNING DIGITAL has an Missing Authentication vulnerability, allowing unauthenticated remote attacker to exploit this functionality to create an account with administrator privilege and subsequently use it to log in.
SSVC
Exploitation: none Automatable: yes Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-306 - Missing Authentication for Critical Function
Assigner
References
Impacted products
Vendor Product Version
LEARNING DIGITAL Orca HCM Affected: 0 , < 11.0 (custom)
Create a notification for this product.
learningdigital orca_hcm Affected: 0 , < 11.0 (custom)
    cpe:2.3:a:learningdigital:orca_hcm:*:*:*:*:*:*:*:*
Create a notification for this product.
Date Public
2024-09-09 02:55
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:learningdigital:orca_hcm:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "orca_hcm",
            "vendor": "learningdigital",
            "versions": [
              {
                "lessThan": "11.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-8584",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-09T13:38:38.578462Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-21T16:54:03.087Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Orca HCM",
          "vendor": "LEARNING DIGITAL",
          "versions": [
            {
              "lessThan": "11.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2024-09-09T02:55:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eOrca HCM from LEARNING DIGITAL has an Missing Authentication vulnerability, allowing unauthenticated remote attacker to exploit this functionality to create an account with administrator privilege and subsequently use it to log in.\u003c/span\u003e"
            }
          ],
          "value": "Orca HCM from LEARNING DIGITAL has an Missing Authentication vulnerability, allowing unauthenticated remote attacker to exploit this functionality to create an account with administrator privilege and subsequently use it to log in."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-1",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-1 Accessing Functionality Not Properly Constrained by ACLs"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-17T03:24:53.774Z",
        "orgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
        "shortName": "twcert"
      },
      "references": [
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://www.twcert.org.tw/tw/cp-132-8039-24e48-1.html"
        },
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://www.twcert.org.tw/en/cp-139-8040-948ef-2.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u0026nbsp; Update to version 11.0 or later"
            }
          ],
          "value": "Update to version 11.0 or later"
        }
      ],
      "source": {
        "advisory": "TVN-202409001",
        "discovery": "EXTERNAL"
      },
      "title": "LEARNING DIGITAL Orca HCM - Missing Authentication",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
    "assignerShortName": "twcert",
    "cveId": "CVE-2024-8584",
    "datePublished": "2024-09-09T02:57:22.560Z",
    "dateReserved": "2024-09-09T02:28:07.857Z",
    "dateUpdated": "2025-02-21T16:54:03.087Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-8530 (GCVE-0-2024-8530)

Vulnerability from cvelistv5 – Published: 2024-10-11 13:55 – Updated: 2024-10-17 19:54
VLAI
Summary
CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause exposure of private data when an already generated “logcaptures” archive is accessed directly by HTTPS.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-306 - Missing Authentication for Critical Function
Assigner
Impacted products
Vendor Product Version
Schneider Electric Data Center Expert Affected: Versions 8.1.1.3 and prior
Create a notification for this product.
schneider-electric data_center_expert Affected: 0 , ≤ 8.1.1.3 (custom)
    cpe:2.3:a:schneider-electric:data_center_expert:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:schneider-electric:data_center_expert:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "data_center_expert",
            "vendor": "schneider-electric",
            "versions": [
              {
                "lessThanOrEqual": "8.1.1.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-8530",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-11T16:40:33.042914Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-17T19:54:14.904Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Data Center Expert",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Versions 8.1.1.3 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE-306: Missing Authentication for Critical Function vulnerability exists that could\ncause exposure of private data when an already generated \u201clogcaptures\u201d archive is accessed\ndirectly by HTTPS."
            }
          ],
          "value": "CWE-306: Missing Authentication for Critical Function vulnerability exists that could\ncause exposure of private data when an already generated \u201clogcaptures\u201d archive is accessed\ndirectly by HTTPS."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-11T13:55:30.353Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-282-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-282-01.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2024-8530",
    "datePublished": "2024-10-11T13:55:30.353Z",
    "dateReserved": "2024-09-06T16:49:22.117Z",
    "dateUpdated": "2024-10-17T19:54:14.904Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-8456 (GCVE-0-2024-8456)

Vulnerability from cvelistv5 – Published: 2024-09-30 07:35 – Updated: 2024-09-30 16:51
VLAI
Title
PLANET Technology switch devices - Missing Authentication for multiple HTTP routes
Summary
Certain switch models from PLANET Technology lack proper access control in firmware upload and download functionality, allowing unauthenticated remote attackers to download and upload firmware and system configurations, ultimately gaining full control of the devices.
SSVC
Exploitation: none Automatable: yes Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-306 - Missing Authentication for Critical Function
Assigner
References
Impacted products
Vendor Product Version
PLANET Technology GS-4210-24PL4C hardware 2.0 Affected: 0 , < 2.305b240719 (custom)
Create a notification for this product.
PLANET Technology GS-4210-24P2S hardware 3.0 Affected: 0 , < 3.305b240802 (custom)
Create a notification for this product.
planet_technology_corp gs-4210-24pl4c_hardware_2.0 Affected: 0 , < 2.305b240719 (custom)
    cpe:2.3:a:planet_technology_corp:gs-4210-24pl4c_hardware_2.0:*:*:*:*:*:*:*:*
Create a notification for this product.
planet_technology_corp gs-4210-24pl4c_hardware_3.0 Affected: 0 , < 3.305b240802 (custom)
    cpe:2.3:a:planet_technology_corp:gs-4210-24pl4c_hardware_3.0:*:*:*:*:*:*:*:*
Create a notification for this product.
Date Public
2024-09-30 07:31
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:planet_technology_corp:gs-4210-24pl4c_hardware_2.0:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "gs-4210-24pl4c_hardware_2.0",
            "vendor": "planet_technology_corp",
            "versions": [
              {
                "lessThan": "2.305b240719",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:planet_technology_corp:gs-4210-24pl4c_hardware_3.0:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "gs-4210-24pl4c_hardware_3.0",
            "vendor": "planet_technology_corp",
            "versions": [
              {
                "lessThan": "3.305b240802",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-8456",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-30T16:49:32.437217Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-30T16:51:08.872Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "GS-4210-24PL4C hardware 2.0",
          "vendor": "PLANET Technology",
          "versions": [
            {
              "lessThan": "2.305b240719",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GS-4210-24P2S hardware 3.0",
          "vendor": "PLANET Technology",
          "versions": [
            {
              "lessThan": "3.305b240802",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2024-09-30T07:31:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eCertain switch models from PLANET Technology lack proper access control in firmware upload and download functionality, allowing unauthenticated remote attackers to download and upload firmware and system configurations, ultimately gaining full control of the devices.\u003c/span\u003e"
            }
          ],
          "value": "Certain switch models from PLANET Technology lack proper access control in firmware upload and download functionality, allowing unauthenticated remote attackers to download and upload firmware and system configurations, ultimately gaining full control of the devices."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-1",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-1 Accessing Functionality Not Properly Constrained by ACLs"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-30T07:35:04.179Z",
        "orgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
        "shortName": "twcert"
      },
      "references": [
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://www.twcert.org.tw/tw/cp-132-8061-91872-1.html"
        },
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://www.twcert.org.tw/en/cp-139-8062-92f17-2.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Update firmware of GS-4210-24PL4C hardware 2.0 to version 2.305b240719 or later.\u003cbr\u003eUpdate firmware of GS-4210-24P2S hardware 3.0 to version 3.305b240802 or later."
            }
          ],
          "value": "Update firmware of GS-4210-24PL4C hardware 2.0 to version 2.305b240719 or later.\nUpdate firmware of GS-4210-24P2S hardware 3.0 to version 3.305b240802 or later."
        }
      ],
      "source": {
        "advisory": "TVN-202409012",
        "discovery": "EXTERNAL"
      },
      "title": "PLANET Technology switch devices - Missing Authentication for multiple HTTP routes",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
    "assignerShortName": "twcert",
    "cveId": "CVE-2024-8456",
    "datePublished": "2024-09-30T07:35:04.179Z",
    "dateReserved": "2024-09-05T02:53:09.094Z",
    "dateUpdated": "2024-09-30T16:51:08.872Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-8419 (GCVE-0-2024-8419)

Vulnerability from cvelistv5 – Published: 2025-06-30 09:39 – Updated: 2026-02-16 15:43
VLAI
Title
Improper Access Control vulnerability in AC4xxS devices
Summary
The endpoint hosts a script that allows an unauthorized remote attacker to put the system in a fail-safe state over the network due to missing authentication.
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-306 - Missing Authentication for Critical Function
Assigner
References
Impacted products
Vendor Product Version
ifm electronic GmbH ifm Smart PLC AC402s Affected: 4.04 , < 4.3.17 (semver)
Affected: 6.1.8
Create a notification for this product.
ifm electronic GmbH ifm Smart PLC AC422s Affected: 4.04 , < 4.3.17 (semver)
Affected: 6.1.8
Create a notification for this product.
ifm electronic GmbH ifm Smart PLC AC424s Affected: 4.04 , < 4.3.17 (semver)
Affected: 6.1.8
Create a notification for this product.
ifm electronic GmbH ifm Smart PLC AC432s Affected: 4.04 , < 4.3.17 (semver)
Affected: 6.1.8
Create a notification for this product.
ifm electronic GmbH ifm Smart PLC AC434s Affected: 4.04 , < 4.3.17 (semver)
Affected: 6.1.8
Create a notification for this product.
Credits
Dmytro Kryhin National Technical University of Ukraine “Igor Sikorsky Kyiv Polytechnic Institute”
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-8419",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-30T15:01:59.417077Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-30T15:07:50.934Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "ifm Smart PLC AC402s",
          "vendor": "ifm electronic GmbH",
          "versions": [
            {
              "lessThan": "4.3.17",
              "status": "affected",
              "version": "4.04",
              "versionType": "semver"
            },
            {
              "status": "affected",
              "version": "6.1.8"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ifm Smart PLC AC422s",
          "vendor": "ifm electronic GmbH",
          "versions": [
            {
              "lessThan": "4.3.17",
              "status": "affected",
              "version": "4.04",
              "versionType": "semver"
            },
            {
              "status": "affected",
              "version": "6.1.8"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ifm Smart PLC AC424s",
          "vendor": "ifm electronic GmbH",
          "versions": [
            {
              "lessThan": "4.3.17",
              "status": "affected",
              "version": "4.04",
              "versionType": "semver"
            },
            {
              "status": "affected",
              "version": "6.1.8"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ifm Smart PLC AC432s",
          "vendor": "ifm electronic GmbH",
          "versions": [
            {
              "lessThan": "4.3.17",
              "status": "affected",
              "version": "4.04",
              "versionType": "semver"
            },
            {
              "status": "affected",
              "version": "6.1.8"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ifm Smart PLC AC434s",
          "vendor": "ifm electronic GmbH",
          "versions": [
            {
              "lessThan": "4.3.17",
              "status": "affected",
              "version": "4.04",
              "versionType": "semver"
            },
            {
              "status": "affected",
              "version": "6.1.8"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Dmytro Kryhin"
        },
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "National Technical University of Ukraine \u201cIgor Sikorsky Kyiv Polytechnic Institute\u201d"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The endpoint hosts a script that allows an unauthorized remote attacker to put the system in a fail-safe state over the network due to missing authentication."
            }
          ],
          "value": "The endpoint hosts a script that allows an unauthorized remote attacker to put the system in a fail-safe state over the network due to missing authentication."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-02-16T15:43:48.124Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://cert.vde.com/en/advisories/VDE-2024-061"
        }
      ],
      "source": {
        "advisory": "VDE-2024-061",
        "defect": [
          "CERT@VDE#641687"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "Improper Access Control vulnerability in AC4xxS devices",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2024-8419",
    "datePublished": "2025-06-30T09:39:50.792Z",
    "dateReserved": "2024-09-04T11:25:22.338Z",
    "dateUpdated": "2026-02-16T15:43:48.124Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2024-8321 (GCVE-0-2024-8321)

Vulnerability from cvelistv5 – Published: 2024-09-10 20:54 – Updated: 2024-09-11 15:20
VLAI
Summary
Missing authentication in Network Isolation of Ivanti EPM before 2022 SU6, or the 2024 September update allows a remote unauthenticated attacker to isolate managed devices from the network.
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-306 - Missing Authentication for Critical Function
Assigner
Impacted products
Vendor Product Version
Ivanti Endpoint Manager Unaffected: 2022 SU6 (custom)
Unaffected: 2024 September Security Update (custom)
Create a notification for this product.
ivanti endpoint_manager Unaffected: 0 , < 2022_su6 (custom)
Unaffected: 2024 , < 2024_september_security_update (custom)
    cpe:2.3:a:ivanti:endpoint_manager:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:ivanti:endpoint_manager:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "affected",
            "product": "endpoint_manager",
            "vendor": "ivanti",
            "versions": [
              {
                "lessThan": "2022_su6",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              },
              {
                "lessThan": "2024_september_security_update",
                "status": "unaffected",
                "version": "2024",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-8321",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-11T14:15:05.575432Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-11T15:20:28.646Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Endpoint Manager",
          "vendor": "Ivanti",
          "versions": [
            {
              "status": "unaffected",
              "version": "2022 SU6",
              "versionType": "custom"
            },
            {
              "status": "unaffected",
              "version": "2024 September Security Update",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eMissing authentication in Network Isolation of Ivanti EPM before 2022 SU6, or the 2024 September update allows a remote unauthenticated attacker to isolate managed devices from the network.\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;\u003c/span\u003e"
            }
          ],
          "value": "Missing authentication in Network Isolation of Ivanti EPM before 2022 SU6, or the 2024 September update allows a remote unauthenticated attacker to isolate managed devices from the network."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-180",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-180 Exploiting Incorrectly Configured Access Control Security Levels"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-10T20:54:02.772Z",
        "orgId": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
        "shortName": "ivanti"
      },
      "references": [
        {
          "url": "https://forums.ivanti.com/s/article/Security-Advisory-EPM-September-2024-for-EPM-2024-and-EPM-2022"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
    "assignerShortName": "ivanti",
    "cveId": "CVE-2024-8321",
    "datePublished": "2024-09-10T20:54:02.772Z",
    "dateReserved": "2024-08-29T19:19:19.784Z",
    "dateUpdated": "2024-09-11T15:20:28.646Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-8320 (GCVE-0-2024-8320)

Vulnerability from cvelistv5 – Published: 2024-09-10 20:52 – Updated: 2024-09-11 15:19
VLAI
Summary
Missing authentication in Network Isolation of Ivanti EPM before 2022 SU6, or the 2024 September update allows a remote unauthenticated attacker to spoof Network Isolation status of managed devices.
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-306 - Missing Authentication for Critical Function
Assigner
Impacted products
Vendor Product Version
Ivanti Endpoint Manager Unaffected: 2022 SU6 (custom)
Unaffected: 2024 September Security Update (custom)
Create a notification for this product.
ivanti automation Unaffected: 0 , < 2022_su6 (custom)
Unaffected: 2024 , < 2024_september_security_update (custom)
    cpe:2.3:a:ivanti:automation:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:ivanti:automation:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "affected",
            "product": "automation",
            "vendor": "ivanti",
            "versions": [
              {
                "lessThan": "2022_su6",
                "status": "unaffected",
                "version": "0",
                "versionType": "custom"
              },
              {
                "lessThan": "2024_september_security_update",
                "status": "unaffected",
                "version": "2024",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-8320",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-11T14:31:35.357495Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-11T15:19:03.245Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Endpoint Manager",
          "vendor": "Ivanti",
          "versions": [
            {
              "status": "unaffected",
              "version": "2022 SU6",
              "versionType": "custom"
            },
            {
              "status": "unaffected",
              "version": "2024 September Security Update",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eMissing authentication in Network Isolation of Ivanti EPM before 2022 SU6, or the 2024 September update allows a remote unauthenticated attacker to spoof Network Isolation status of managed devices.\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;\u003c/span\u003e"
            }
          ],
          "value": "Missing authentication in Network Isolation of Ivanti EPM before 2022 SU6, or the 2024 September update allows a remote unauthenticated attacker to spoof Network Isolation status of managed devices."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-148",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-148 Content Spoofing"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-10T20:52:31.146Z",
        "orgId": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
        "shortName": "ivanti"
      },
      "references": [
        {
          "url": "https://forums.ivanti.com/s/article/Security-Advisory-EPM-September-2024-for-EPM-2024-and-EPM-2022"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "3c1d8aa1-5a33-4ea4-8992-aadd6440af75",
    "assignerShortName": "ivanti",
    "cveId": "CVE-2024-8320",
    "datePublished": "2024-09-10T20:52:31.146Z",
    "dateReserved": "2024-08-29T19:19:18.232Z",
    "dateUpdated": "2024-09-11T15:19:03.245Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation
Architecture and Design
  • Divide the software into anonymous, normal, privileged, and administrative areas. Identify which of these areas require a proven user identity, and use a centralized authentication capability.
  • Identify all potential communication channels, or other means of interaction with the software, to ensure that all channels are appropriately protected, including those channels that are assumed to be accessible only by authorized parties. Developers sometimes perform authentication at the primary channel, but open up a secondary channel that is assumed to be private. For example, a login mechanism may be listening on one network port, but after successful authentication, it may open up a second port where it waits for the connection, but avoids authentication because it assumes that only the authenticated party will connect to the port.
  • In general, if the software or protocol allows a single session or user state to persist across multiple connections or channels, authentication and appropriate credential management need to be used throughout.
Mitigation MIT-15
Architecture and Design

For any security checks that are performed on the client side, ensure that these checks are duplicated on the server side, in order to avoid CWE-602. Attackers can bypass the client-side checks by modifying values after the checks have been performed, or by changing the client to remove the client-side checks entirely. Then, these modified values would be submitted to the server.

Mitigation
Architecture and Design
  • Where possible, avoid implementing custom, "grow-your-own" authentication routines and consider using authentication capabilities as provided by the surrounding framework, operating system, or environment. These capabilities may avoid common weaknesses that are unique to authentication; support automatic auditing and tracking; and make it easier to provide a clear separation between authentication tasks and authorization tasks.
  • In environments such as the World Wide Web, the line between authentication and authorization is sometimes blurred. If custom authentication routines are required instead of those provided by the server, then these routines must be applied to every single page, since these pages could be requested directly.
Mitigation MIT-4.5
Architecture and Design

Strategy: Libraries or Frameworks

  • Use a vetted library or framework that does not allow this weakness to occur or provides constructs that make this weakness easier to avoid.
  • For example, consider using libraries with authentication capabilities such as OpenSSL or the ESAPI Authenticator [REF-45].
Mitigation
Implementation System Configuration Operation

When storing data in the cloud (e.g., S3 buckets, Azure blobs, Google Cloud Storage, etc.), use the provider's controls to require strong authentication for users who should be allowed to access the data [REF-1297] [REF-1298] [REF-1302].

CAPEC-12: Choosing Message Identifier

This pattern of attack is defined by the selection of messages distributed via multicast or public information channels that are intended for another client by determining the parameter value assigned to that client. This attack allows the adversary to gain access to potentially privileged information, and to possibly perpetrate other attacks through the distribution means by impersonation. If the channel/message being manipulated is an input rather than output mechanism for the system, (such as a command bus), this style of attack could be used to change the adversary's identifier to more a privileged one.

CAPEC-166: Force the System to Reset Values

An attacker forces the target into a previous state in order to leverage potential weaknesses in the target dependent upon a prior configuration or state-dependent factors. Even in cases where an attacker may not be able to directly control the configuration of the targeted application, they may be able to reset the configuration to a prior state since many applications implement reset functions.

CAPEC-216: Communication Channel Manipulation

An adversary manipulates a setting or parameter on communications channel in order to compromise its security. This can result in information exposure, insertion/removal of information from the communications stream, and/or potentially system compromise.

CAPEC-36: Using Unpublished Interfaces or Functionality

An adversary searches for and invokes interfaces or functionality that the target system designers did not intend to be publicly available. If interfaces fail to authenticate requests, the attacker may be able to invoke functionality they are not authorized for.

CAPEC-62: Cross Site Request Forgery

An attacker crafts malicious web links and distributes them (via web pages, email, etc.), typically in a targeted manner, hoping to induce users to click on the link and execute the malicious action against some third-party application. If successful, the action embedded in the malicious link will be processed and accepted by the targeted application with the users' privilege level. This type of attack leverages the persistence and implicit trust placed in user session cookies by many web applications today. In such an architecture, once the user authenticates to an application and a session cookie is created on the user's system, all following transactions for that session are authenticated using that cookie including potential actions initiated by an attacker and simply "riding" the existing session cookie.