Common Weakness Enumeration

CWE-312

Allowed

Cleartext Storage of Sensitive Information

Abstraction: Base · Status: Draft

The product stores sensitive information in cleartext within a resource that might be accessible to another control sphere.

1017 vulnerabilities reference this CWE, most recent first.

CVE-2019-3753 (GCVE-0-2019-3753)

Vulnerability from cvelistv5 – Published: 2019-08-20 18:47 – Updated: 2024-09-16 20:48
VLAI
Summary
Dell EMC PowerConnect 8024, 7000, M6348, M6220, M8024 and M8024-K running firmware versions prior to 5.1.15.2 contain a plain-text password storage vulnerability. TACACS\Radius credentials are stored in plain text in the system settings menu. An authenticated malicious user with access to the system settings menu may obtain the exposed password to use it in further attacks.
CWE
  • CWE-312 - Cleartext Storage of Sensitive Information
Assigner
References
Impacted products
Vendor Product Version
Dell EMC PowerConnect 8024 Affected: unspecified , < 5.1.15.2 (custom)
Create a notification for this product.
Dell EMC PowerConnect 7000 Affected: unspecified , < 5.1.15.2 (custom)
Create a notification for this product.
Dell EMC PowerConnect M6348 Affected: unspecified , < 5.1.15.2 (custom)
Create a notification for this product.
Dell EMC PowerConnect M6220 Affected: unspecified , < 5.1.15.2 (custom)
Create a notification for this product.
Dell EMC PowerConnect M8024 Affected: unspecified , < 5.1.15.2 (custom)
Create a notification for this product.
Dell EMC PowerConnect M8024-K Affected: unspecified , < 5.1.15.2 (custom)
Create a notification for this product.
Date Public
2019-08-16 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T19:19:18.453Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/article/sln318359/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "PowerConnect 8024",
          "vendor": "Dell EMC",
          "versions": [
            {
              "lessThan": "5.1.15.2",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "PowerConnect 7000",
          "vendor": "Dell EMC",
          "versions": [
            {
              "lessThan": "5.1.15.2",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "PowerConnect M6348",
          "vendor": "Dell EMC",
          "versions": [
            {
              "lessThan": "5.1.15.2",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "PowerConnect M6220",
          "vendor": "Dell EMC",
          "versions": [
            {
              "lessThan": "5.1.15.2",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "PowerConnect M8024",
          "vendor": "Dell EMC",
          "versions": [
            {
              "lessThan": "5.1.15.2",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "PowerConnect  M8024-K",
          "vendor": "Dell EMC",
          "versions": [
            {
              "lessThan": "5.1.15.2",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2019-08-16T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC PowerConnect 8024, 7000, M6348, M6220, M8024 and M8024-K running firmware versions prior to 5.1.15.2 contain a plain-text password storage vulnerability. TACACS\\Radius credentials are stored in plain text in the system settings menu. An authenticated malicious user with access to the system settings menu may obtain the exposed password to use it in further attacks."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312 Cleartext Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-08-20T18:47:01.000Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.dell.com/support/article/sln318359/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.7"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2019-08-16T04:00:00.000Z",
          "ID": "CVE-2019-3753",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "PowerConnect 8024",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "5.1.15.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "PowerConnect 7000",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "5.1.15.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "PowerConnect M6348",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "5.1.15.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "PowerConnect M6220",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "5.1.15.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "PowerConnect M8024",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "5.1.15.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "PowerConnect  M8024-K",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "5.1.15.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell EMC"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC PowerConnect 8024, 7000, M6348, M6220, M8024 and M8024-K running firmware versions prior to 5.1.15.2 contain a plain-text password storage vulnerability. TACACS\\Radius credentials are stored in plain text in the system settings menu. An authenticated malicious user with access to the system settings menu may obtain the exposed password to use it in further attacks."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.7"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-312 Cleartext Storage of Sensitive Information"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/article/sln318359/",
              "refsource": "CONFIRM",
              "url": "https://www.dell.com/support/article/sln318359/"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2019-3753",
    "datePublished": "2019-08-20T18:47:01.835Z",
    "dateReserved": "2019-01-03T00:00:00.000Z",
    "dateUpdated": "2024-09-16T20:48:15.827Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-19009 (GCVE-0-2018-19009)

Vulnerability from cvelistv5 – Published: 2019-01-25 20:00 – Updated: 2024-09-16 23:21
VLAI
Summary
Pilz PNOZmulti Configurator prior to version 10.9 allows an authenticated attacker with local access to the system containing the PNOZmulti Configurator software to view sensitive credential data in clear-text. This sensitive data is applicable to only the PMI m107 diag HMI device. An attacker with access to this sensitive data and physical access to the PMI m107 diag can modify data on the HMI device.
Severity
No CVSS data available.
CWE
  • CWE-312 - CLEARTEXT STORAGE OF SENSITIVE INFORMATION CWE-312
Assigner
References
Impacted products
Vendor Product Version
Pilz Pilz PNOZmulti Configurator Affected: All versions prior to version 10.9
Create a notification for this product.
Date Public
2019-01-10 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T11:23:09.032Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-010-03"
          },
          {
            "name": "106529",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/106529"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Pilz PNOZmulti Configurator",
          "vendor": "Pilz",
          "versions": [
            {
              "status": "affected",
              "version": "All versions prior to version 10.9"
            }
          ]
        }
      ],
      "datePublic": "2019-01-10T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Pilz PNOZmulti Configurator prior to version 10.9 allows an authenticated attacker with local access to the system containing the PNOZmulti Configurator software to view sensitive credential data in clear-text. This sensitive data is applicable to only the PMI m107 diag HMI device. An attacker with access to this sensitive data and physical access to the PMI m107 diag can modify data on the HMI device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CLEARTEXT STORAGE OF SENSITIVE INFORMATION CWE-312",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-01-26T10:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-010-03"
        },
        {
          "name": "106529",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/106529"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2019-01-10T00:00:00",
          "ID": "CVE-2018-19009",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Pilz PNOZmulti Configurator",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions prior to version 10.9"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Pilz"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Pilz PNOZmulti Configurator prior to version 10.9 allows an authenticated attacker with local access to the system containing the PNOZmulti Configurator software to view sensitive credential data in clear-text. This sensitive data is applicable to only the PMI m107 diag HMI device. An attacker with access to this sensitive data and physical access to the PMI m107 diag can modify data on the HMI device."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CLEARTEXT STORAGE OF SENSITIVE INFORMATION CWE-312"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-010-03",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-010-03"
            },
            {
              "name": "106529",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/106529"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-19009",
    "datePublished": "2019-01-25T20:00:00.000Z",
    "dateReserved": "2018-11-06T00:00:00.000Z",
    "dateUpdated": "2024-09-16T23:21:02.043Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-16498 (GCVE-0-2018-16498)

Vulnerability from cvelistv5 – Published: 2021-05-26 18:45 – Updated: 2024-08-05 10:24
VLAI
Summary
In Versa Director, the unencrypted backup files stored on the Versa deployment contain credentials stored within configuration files. These credentials are for various application components such as SNMP, and SSL and Trust keystores.
Severity
No CVSS data available.
CWE
  • CWE-312 - Cleartext Storage of Sensitive Information (CWE-312)
Assigner
References
URL Tags
https://hackerone.com/reports/1168195 x_refsource_MISC
Impacted products
Vendor Product Version
n/a Versa Director Affected: Fixed Versions: 16.1R2S11, 20.2.2, 21.1.1, 21.2.1
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T10:24:32.800Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://hackerone.com/reports/1168195"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Versa Director",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Fixed Versions: 16.1R2S11, 20.2.2, 21.1.1, 21.2.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "In Versa Director, the unencrypted backup files stored on the Versa deployment contain credentials stored within configuration files. These credentials are for various application components such as SNMP, and SSL and Trust keystores."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "Cleartext Storage of Sensitive Information (CWE-312)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-05-26T18:45:50.000Z",
        "orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
        "shortName": "hackerone"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://hackerone.com/reports/1168195"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "support@hackerone.com",
          "ID": "CVE-2018-16498",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Versa Director",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Fixed Versions: 16.1R2S11, 20.2.2, 21.1.1, 21.2.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In Versa Director, the unencrypted backup files stored on the Versa deployment contain credentials stored within configuration files. These credentials are for various application components such as SNMP, and SSL and Trust keystores."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Cleartext Storage of Sensitive Information (CWE-312)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://hackerone.com/reports/1168195",
              "refsource": "MISC",
              "url": "https://hackerone.com/reports/1168195"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
    "assignerShortName": "hackerone",
    "cveId": "CVE-2018-16498",
    "datePublished": "2021-05-26T18:45:50.000Z",
    "dateReserved": "2018-09-04T00:00:00.000Z",
    "dateUpdated": "2024-08-05T10:24:32.800Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-10871 (GCVE-0-2018-10871)

Vulnerability from cvelistv5 – Published: 2018-07-18 13:00 – Updated: 2024-08-05 07:46
VLAI
Summary
389-ds-base before versions 1.3.8.5, 1.4.0.12 is vulnerable to a Cleartext Storage of Sensitive Information. By default, when the Replica and/or retroChangeLog plugins are enabled, 389-ds-base stores passwords in plaintext format in their respective changelog files. An attacker with sufficiently high privileges, such as root or Directory Manager, can query these files in order to retrieve plaintext passwords.
CWE
Assigner
References
Impacted products
Vendor Product Version
[UNKNOWN] 389-ds-base Affected: 389-ds-base 1.3.8.5
Affected: 389-ds-base 1.4.0.12
Create a notification for this product.
Date Public
2018-06-18 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T07:46:47.376Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2018-10871"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://pagure.io/389-ds-base/issue/49789"
          },
          {
            "name": "[debian-lts-announce] 20180830 [SECURITY] [DLA 1483-1] 389-ds-base security update",
            "tags": [
              "mailing-list",
              "x_refsource_MLIST",
              "x_transferred"
            ],
            "url": "https://lists.debian.org/debian-lts-announce/2018/08/msg00032.html"
          },
          {
            "name": "RHSA-2019:3401",
            "tags": [
              "vendor-advisory",
              "x_refsource_REDHAT",
              "x_transferred"
            ],
            "url": "https://access.redhat.com/errata/RHSA-2019:3401"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "389-ds-base",
          "vendor": "[UNKNOWN]",
          "versions": [
            {
              "status": "affected",
              "version": "389-ds-base 1.3.8.5"
            },
            {
              "status": "affected",
              "version": "389-ds-base 1.4.0.12"
            }
          ]
        }
      ],
      "datePublic": "2018-06-18T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "389-ds-base before versions 1.3.8.5, 1.4.0.12 is vulnerable to a Cleartext Storage of Sensitive Information. By default, when the Replica and/or retroChangeLog plugins are enabled, 389-ds-base stores passwords in plaintext format in their respective changelog files. An attacker with sufficiently high privileges, such as root or Directory Manager, can query these files in order to retrieve plaintext passwords."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 3.8,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-11-06T00:08:04.000Z",
        "orgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
        "shortName": "redhat"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2018-10871"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://pagure.io/389-ds-base/issue/49789"
        },
        {
          "name": "[debian-lts-announce] 20180830 [SECURITY] [DLA 1483-1] 389-ds-base security update",
          "tags": [
            "mailing-list",
            "x_refsource_MLIST"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2018/08/msg00032.html"
        },
        {
          "name": "RHSA-2019:3401",
          "tags": [
            "vendor-advisory",
            "x_refsource_REDHAT"
          ],
          "url": "https://access.redhat.com/errata/RHSA-2019:3401"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secalert@redhat.com",
          "ID": "CVE-2018-10871",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "389-ds-base",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "389-ds-base 1.3.8.5"
                          },
                          {
                            "version_value": "389-ds-base 1.4.0.12"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "[UNKNOWN]"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "389-ds-base before versions 1.3.8.5, 1.4.0.12 is vulnerable to a Cleartext Storage of Sensitive Information. By default, when the Replica and/or retroChangeLog plugins are enabled, 389-ds-base stores passwords in plaintext format in their respective changelog files. An attacker with sufficiently high privileges, such as root or Directory Manager, can query these files in order to retrieve plaintext passwords."
            }
          ]
        },
        "impact": {
          "cvss": [
            [
              {
                "vectorString": "3.8/CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:N",
                "version": "3.0"
              }
            ]
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-312"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2018-10871",
              "refsource": "CONFIRM",
              "url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2018-10871"
            },
            {
              "name": "https://pagure.io/389-ds-base/issue/49789",
              "refsource": "CONFIRM",
              "url": "https://pagure.io/389-ds-base/issue/49789"
            },
            {
              "name": "[debian-lts-announce] 20180830 [SECURITY] [DLA 1483-1] 389-ds-base security update",
              "refsource": "MLIST",
              "url": "https://lists.debian.org/debian-lts-announce/2018/08/msg00032.html"
            },
            {
              "name": "RHSA-2019:3401",
              "refsource": "REDHAT",
              "url": "https://access.redhat.com/errata/RHSA-2019:3401"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
    "assignerShortName": "redhat",
    "cveId": "CVE-2018-10871",
    "datePublished": "2018-07-18T13:00:00.000Z",
    "dateReserved": "2018-05-09T00:00:00.000Z",
    "dateUpdated": "2024-08-05T07:46:47.376Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-20040 (GCVE-0-2017-20040)

Vulnerability from cvelistv5 – Published: 2022-06-11 10:00 – Updated: 2025-04-15 14:26
VLAI
Title
SICUNET Access Controller Password Storage cleartext storage
Summary
A vulnerability was found in SICUNET Access Controller 0.32-05z. It has been declared as problematic. This vulnerability affects unknown code of the component Password Storage. The manipulation leads to weak encryption. Attacking locally is a requirement.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-312 - Cleartext Storage of Sensitive Information
Assigner
References
Impacted products
Vendor Product Version
SICUNET Access Controller Affected: 0.32-05z
Create a notification for this product.
Credits
Andrew Griffiths
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T21:45:25.213Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://seclists.org/fulldisclosure/2017/Mar/25"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.98908"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2017-20040",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-14T17:13:22.044387Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-15T14:26:44.752Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Access Controller",
          "vendor": "SICUNET",
          "versions": [
            {
              "status": "affected",
              "version": "0.32-05z"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Andrew Griffiths"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in SICUNET Access Controller 0.32-05z. It has been declared as problematic. This vulnerability affects unknown code of the component Password Storage. The manipulation leads to weak encryption. Attacking locally is a requirement."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312 Cleartext Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-06-11T10:00:26.000Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://seclists.org/fulldisclosure/2017/Mar/25"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://vuldb.com/?id.98908"
        }
      ],
      "title": "SICUNET Access Controller Password Storage cleartext storage",
      "x_generator": "vuldb.com",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cna@vuldb.com",
          "ID": "CVE-2017-20040",
          "REQUESTER": "cna@vuldb.com",
          "STATE": "PUBLIC",
          "TITLE": "SICUNET Access Controller Password Storage cleartext storage"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Access Controller",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "0.32-05z"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "SICUNET"
              }
            ]
          }
        },
        "credit": "Andrew Griffiths",
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability was found in SICUNET Access Controller 0.32-05z. It has been declared as problematic. This vulnerability affects unknown code of the component Password Storage. The manipulation leads to weak encryption. Attacking locally is a requirement."
            }
          ]
        },
        "generator": "vuldb.com",
        "impact": {
          "cvss": {
            "baseScore": "5.9",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-312 Cleartext Storage of Sensitive Information"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://seclists.org/fulldisclosure/2017/Mar/25",
              "refsource": "MISC",
              "url": "http://seclists.org/fulldisclosure/2017/Mar/25"
            },
            {
              "name": "https://vuldb.com/?id.98908",
              "refsource": "MISC",
              "url": "https://vuldb.com/?id.98908"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2017-20040",
    "datePublished": "2022-06-11T10:00:26.000Z",
    "dateReserved": "2022-06-05T00:00:00.000Z",
    "dateUpdated": "2025-04-15T14:26:44.752Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-9663 (GCVE-0-2017-9663)

Vulnerability from cvelistv5 – Published: 2018-01-09 21:00 – Updated: 2024-08-05 17:18
VLAI
Summary
An Cleartext Storage of Sensitive Information issue was discovered in General Motors (GM) and Shanghai OnStar (SOS) SOS iOS Client 7.1. Successful exploitation of this vulnerability may allow a remote attacker to access an encryption key that is stored in cleartext in memory.
Severity
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a General Motors and Shanghai OnStar (SOS) iOS Client Affected: General Motors and Shanghai OnStar (SOS) iOS Client
Date Public
2018-01-09 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T17:18:00.404Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-234-04"
          },
          {
            "name": "102481",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/102481"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "General Motors and Shanghai OnStar (SOS) iOS Client",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "General Motors and Shanghai OnStar (SOS) iOS Client"
            }
          ]
        }
      ],
      "datePublic": "2018-01-09T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An Cleartext Storage of Sensitive Information issue was discovered in General Motors (GM) and Shanghai OnStar (SOS) SOS iOS Client 7.1. Successful exploitation of this vulnerability may allow a remote attacker to access an encryption key that is stored in cleartext in memory."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-01-12T10:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-234-04"
        },
        {
          "name": "102481",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/102481"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-9663",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "General Motors and Shanghai OnStar (SOS) iOS Client",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "General Motors and Shanghai OnStar (SOS) iOS Client"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An Cleartext Storage of Sensitive Information issue was discovered in General Motors (GM) and Shanghai OnStar (SOS) SOS iOS Client 7.1. Successful exploitation of this vulnerability may allow a remote attacker to access an encryption key that is stored in cleartext in memory."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-312"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-234-04",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-234-04"
            },
            {
              "name": "102481",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/102481"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-9663",
    "datePublished": "2018-01-09T21:00:00.000Z",
    "dateReserved": "2017-06-14T00:00:00.000Z",
    "dateUpdated": "2024-08-05T17:18:00.404Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-9654 (GCVE-0-2017-9654)

Vulnerability from cvelistv5 – Published: 2018-04-24 15:00 – Updated: 2024-09-17 03:43
VLAI
Summary
The Philips DoseWise Portal web-based application versions 1.1.7.333 and 2.1.1.3069 stores login credentials in clear text within backend system files. CVSS v3 base score: 6.5, CVSS vector string: AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N.
Severity
No CVSS data available.
CWE
  • CWE-312 - Cleartext storage of sensitive information CWE-312
Assigner
References
Impacted products
Vendor Product Version
Philips DoseWise Portal Affected: 1.1.7.333
Affected: 2.1.1.3069
Create a notification for this product.
Date Public
2017-08-17 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T17:18:00.345Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "100471",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/100471"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-229-01"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.philips.com/productsecurity"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "DoseWise Portal",
          "vendor": "Philips",
          "versions": [
            {
              "status": "affected",
              "version": "1.1.7.333"
            },
            {
              "status": "affected",
              "version": "2.1.1.3069"
            }
          ]
        }
      ],
      "datePublic": "2017-08-17T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "The Philips DoseWise Portal web-based application versions 1.1.7.333 and 2.1.1.3069 stores login credentials in clear text within backend system files. CVSS v3 base score: 6.5, CVSS vector string: AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "Cleartext storage of sensitive information CWE-312",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-04-25T09:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "100471",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/100471"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-229-01"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.philips.com/productsecurity"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2017-08-17T00:00:00",
          "ID": "CVE-2017-9654",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "DoseWise Portal",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "1.1.7.333"
                          },
                          {
                            "version_value": "2.1.1.3069"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Philips"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The Philips DoseWise Portal web-based application versions 1.1.7.333 and 2.1.1.3069 stores login credentials in clear text within backend system files. CVSS v3 base score: 6.5, CVSS vector string: AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Cleartext storage of sensitive information CWE-312"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "100471",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/100471"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-229-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-17-229-01"
            },
            {
              "name": "http://www.philips.com/productsecurity",
              "refsource": "CONFIRM",
              "url": "http://www.philips.com/productsecurity"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-9654",
    "datePublished": "2018-04-24T15:00:00.000Z",
    "dateReserved": "2017-06-14T00:00:00.000Z",
    "dateUpdated": "2024-09-17T03:43:28.188Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-3214 (GCVE-0-2017-3214)

Vulnerability from cvelistv5 – Published: 2017-06-20 00:00 – Updated: 2024-08-05 14:16
VLAI
Summary
The Milwaukee ONE-KEY Android mobile application stores the master token in plaintext in the apk binary.
Severity
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
Milwaukee Tool ONE-KEY Affected: unspecified
Create a notification for this product.
Date Public
2017-06-19 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T14:16:28.243Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://duo.com/blog/bug-hunting-drilling-into-the-internet-of-things-iot"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "ONE-KEY",
          "vendor": "Milwaukee Tool",
          "versions": [
            {
              "status": "affected",
              "version": "unspecified"
            }
          ]
        }
      ],
      "datePublic": "2017-06-19T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "The Milwaukee ONE-KEY Android mobile application stores the master token in plaintext in the apk binary."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-06-19T23:57:01.000Z",
        "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "shortName": "certcc"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://duo.com/blog/bug-hunting-drilling-into-the-internet-of-things-iot"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cert@cert.org",
          "ID": "CVE-2017-3214",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "ONE-KEY",
                      "version": {
                        "version_data": [
                          {
                            "version_value": ""
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Milwaukee Tool"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The Milwaukee ONE-KEY Android mobile application stores the master token in plaintext in the apk binary."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-312"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://duo.com/blog/bug-hunting-drilling-into-the-internet-of-things-iot",
              "refsource": "MISC",
              "url": "https://duo.com/blog/bug-hunting-drilling-into-the-internet-of-things-iot"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
    "assignerShortName": "certcc",
    "cveId": "CVE-2017-3214",
    "datePublished": "2017-06-20T00:00:00.000Z",
    "dateReserved": "2016-12-05T00:00:00.000Z",
    "dateUpdated": "2024-08-05T14:16:28.243Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-2672 (GCVE-0-2017-2672)

Vulnerability from cvelistv5 – Published: 2018-06-21 13:00 – Updated: 2024-08-05 14:02
VLAI
Summary
A flaw was found in foreman before version 1.15 in the logging of adding and registering images. An attacker with access to the foreman log file would be able to view passwords for provisioned systems in the log file, allowing them to access those systems.
CWE
Assigner
References
Impacted products
Vendor Product Version
[UNKNOWN] foreman Affected: foreman 1.15
Create a notification for this product.
Date Public
2017-04-04 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T14:02:07.221Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://projects.theforeman.org/issues/19169"
          },
          {
            "name": "RHSA-2018:0336",
            "tags": [
              "vendor-advisory",
              "x_refsource_REDHAT",
              "x_transferred"
            ],
            "url": "https://access.redhat.com/errata/RHSA-2018:0336"
          },
          {
            "name": "97526",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/97526"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2017-2672"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "foreman",
          "vendor": "[UNKNOWN]",
          "versions": [
            {
              "status": "affected",
              "version": "foreman 1.15"
            }
          ]
        }
      ],
      "datePublic": "2017-04-04T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A flaw was found in foreman before version 1.15 in the logging of adding and registering images. An attacker with access to the foreman log file would be able to view passwords for provisioned systems in the log file, allowing them to access those systems."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-06-22T09:57:01.000Z",
        "orgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
        "shortName": "redhat"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://projects.theforeman.org/issues/19169"
        },
        {
          "name": "RHSA-2018:0336",
          "tags": [
            "vendor-advisory",
            "x_refsource_REDHAT"
          ],
          "url": "https://access.redhat.com/errata/RHSA-2018:0336"
        },
        {
          "name": "97526",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/97526"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2017-2672"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secalert@redhat.com",
          "ID": "CVE-2017-2672",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "foreman",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "foreman 1.15"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "[UNKNOWN]"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A flaw was found in foreman before version 1.15 in the logging of adding and registering images. An attacker with access to the foreman log file would be able to view passwords for provisioned systems in the log file, allowing them to access those systems."
            }
          ]
        },
        "impact": {
          "cvss": [
            [
              {
                "vectorString": "6.5/CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.0"
              }
            ]
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-312"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://projects.theforeman.org/issues/19169",
              "refsource": "CONFIRM",
              "url": "https://projects.theforeman.org/issues/19169"
            },
            {
              "name": "RHSA-2018:0336",
              "refsource": "REDHAT",
              "url": "https://access.redhat.com/errata/RHSA-2018:0336"
            },
            {
              "name": "97526",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/97526"
            },
            {
              "name": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2017-2672",
              "refsource": "CONFIRM",
              "url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2017-2672"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
    "assignerShortName": "redhat",
    "cveId": "CVE-2017-2672",
    "datePublished": "2018-06-21T13:00:00.000Z",
    "dateReserved": "2016-12-01T00:00:00.000Z",
    "dateUpdated": "2024-08-05T14:02:07.221Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2016-8366 (GCVE-0-2016-8366)

Vulnerability from cvelistv5 – Published: 2018-04-05 16:00 – Updated: 2024-09-16 21:08
VLAI
Summary
Webvisit in Phoenix Contact ILC PLCs offers a password macro to protect HMI pages on the PLC against casual or coincidental opening of HMI pages by the user. The password macro can be configured in a way that the password is stored and transferred in clear text.
Severity
No CVSS data available.
CWE
  • CWE-312 - Cleartext Storage of Sensitive Information
Assigner
References
Impacted products
Date Public
2016-11-08 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T02:20:30.995Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-313-01"
          },
          {
            "name": "45586",
            "tags": [
              "exploit",
              "x_refsource_EXPLOIT-DB",
              "x_transferred"
            ],
            "url": "https://www.exploit-db.com/exploits/45586/"
          },
          {
            "name": "94163",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/94163"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Phoenix Contact ILC PLCs",
          "vendor": "Phoenix Contact",
          "versions": [
            {
              "status": "affected",
              "version": "All ILC 1xx PLCs"
            }
          ]
        }
      ],
      "datePublic": "2016-11-08T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Webvisit in Phoenix Contact ILC PLCs offers a password macro to protect HMI pages on the PLC against casual or coincidental opening of HMI pages by the user. The password macro can be configured in a way that the password is stored and transferred in clear text."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312: Cleartext Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-13T09:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-313-01"
        },
        {
          "name": "45586",
          "tags": [
            "exploit",
            "x_refsource_EXPLOIT-DB"
          ],
          "url": "https://www.exploit-db.com/exploits/45586/"
        },
        {
          "name": "94163",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/94163"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2016-11-08T00:00:00",
          "ID": "CVE-2016-8366",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Phoenix Contact ILC PLCs",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All ILC 1xx PLCs"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Phoenix Contact"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Webvisit in Phoenix Contact ILC PLCs offers a password macro to protect HMI pages on the PLC against casual or coincidental opening of HMI pages by the user. The password macro can be configured in a way that the password is stored and transferred in clear text."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-312: Cleartext Storage of Sensitive Information"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-313-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-313-01"
            },
            {
              "name": "45586",
              "refsource": "EXPLOIT-DB",
              "url": "https://www.exploit-db.com/exploits/45586/"
            },
            {
              "name": "94163",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/94163"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2016-8366",
    "datePublished": "2018-04-05T16:00:00.000Z",
    "dateReserved": "2016-09-28T00:00:00.000Z",
    "dateUpdated": "2024-09-16T21:08:54.504Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation
Implementation System Configuration Operation

When storing data in the cloud (e.g., S3 buckets, Azure blobs, Google Cloud Storage, etc.), use the provider's controls to encrypt the data at rest. [REF-1297] [REF-1299] [REF-1301]

Mitigation
Implementation System Configuration Operation

In some systems/environments such as cloud, the use of "double encryption" (at both the software and hardware layer) might be required, and the developer might be solely responsible for both layers, instead of shared responsibility with the administrator of the broader system/environment.

CAPEC-37: Retrieve Embedded Sensitive Data

An attacker examines a target system to find sensitive data that has been embedded within it. This information can reveal confidential contents, such as account numbers or individual keys/credentials that can be used as an intermediate step in a larger attack.