CWE-312
AllowedCleartext Storage of Sensitive Information
Abstraction: Base · Status: Draft
The product stores sensitive information in cleartext within a resource that might be accessible to another control sphere.
1017 vulnerabilities reference this CWE, most recent first.
CVE-2020-7513 (GCVE-0-2020-7513)
Vulnerability from cvelistv5 – Published: 2020-06-16 19:45 – Updated: 2024-08-04 09:33- CWE-312 - Cleartext Storage of Sensitive Information
| URL | Tags |
|---|---|
| https://www.se.com/ww/en/download/document/SEVD-2… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Easergy T300 (Firmware version 1.5.2 and older) |
Affected:
Easergy T300 (Firmware version 1.5.2 and older)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:19.702Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-161-04"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Easergy T300 (Firmware version 1.5.2 and older)",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Easergy T300 (Firmware version 1.5.2 and older)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-312: Cleartext Storage of Sensitive Information vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to intercept traffic and read configuration data."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312: Cleartext Storage of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-06-16T19:45:31.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-161-04"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-7513",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Easergy T300 (Firmware version 1.5.2 and older)",
"version": {
"version_data": [
{
"version_value": "Easergy T300 (Firmware version 1.5.2 and older)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-312: Cleartext Storage of Sensitive Information vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to intercept traffic and read configuration data."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-312: Cleartext Storage of Sensitive Information"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-161-04",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-161-04"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2020-7513",
"datePublished": "2020-06-16T19:45:31.000Z",
"dateReserved": "2020-01-21T00:00:00.000Z",
"dateUpdated": "2024-08-04T09:33:19.702Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-6980 (GCVE-0-2020-6980)
Vulnerability from cvelistv5 – Published: 2020-03-16 15:36 – Updated: 2024-08-04 09:18- CWE-312 - CLEARTEXT STORAGE OF SENSITIVE INFORMATION CWE-312
| URL | Tags |
|---|---|
| https://www.us-cert.gov/ics/advisories/icsa-20-070-06 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior |
Affected:
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:18:02.979Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-070-06"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, If Simple Mail Transfer Protocol (SMTP) account data is saved in RSLogix 500, a local attacker with access to a victim\u2019s project may be able to gather SMTP server authentication data as it is written to the project file in cleartext."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CLEARTEXT STORAGE OF SENSITIVE INFORMATION CWE-312",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-03-16T15:36:51.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-070-06"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-6980",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior",
"version": {
"version_data": [
{
"version_value": "Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, If Simple Mail Transfer Protocol (SMTP) account data is saved in RSLogix 500, a local attacker with access to a victim\u2019s project may be able to gather SMTP server authentication data as it is written to the project file in cleartext."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CLEARTEXT STORAGE OF SENSITIVE INFORMATION CWE-312"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-070-06",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-070-06"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-6980",
"datePublished": "2020-03-16T15:36:51.000Z",
"dateReserved": "2020-01-14T00:00:00.000Z",
"dateUpdated": "2024-08-04T09:18:02.979Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-5723 (GCVE-0-2020-5723)
Vulnerability from cvelistv5 – Published: 2020-03-30 19:03 – Updated: 2024-08-04 08:39- CWE-312 - Cleartext Password Storage (CWE-312)
| URL | Tags |
|---|---|
| https://www.tenable.com/security/research/tra-2020-17 | x_refsource_CONFIRM |
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Grandstream UCM6200 series |
Affected:
1.0.20.20 and below
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T08:39:25.688Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2020-17"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Grandstream UCM6200 series",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "1.0.20.20 and below"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The UCM6200 series 1.0.20.22 and below stores unencrypted user passwords in an SQLite database. This could allow an attacker to retrieve all passwords and possibly gain elevated privileges."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "Cleartext Password Storage (CWE-312)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-03-30T19:03:22.000Z",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.tenable.com/security/research/tra-2020-17"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2020-5723",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Grandstream UCM6200 series",
"version": {
"version_data": [
{
"version_value": "1.0.20.20 and below"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The UCM6200 series 1.0.20.22 and below stores unencrypted user passwords in an SQLite database. This could allow an attacker to retrieve all passwords and possibly gain elevated privileges."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Cleartext Password Storage (CWE-312)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2020-17",
"refsource": "CONFIRM",
"url": "https://www.tenable.com/security/research/tra-2020-17"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2020-5723",
"datePublished": "2020-03-30T19:03:22.000Z",
"dateReserved": "2020-01-06T00:00:00.000Z",
"dateUpdated": "2024-08-04T08:39:25.688Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-25279 (GCVE-0-2019-25279)
Vulnerability from cvelistv5 – Published: 2026-01-07 23:10 – Updated: 2026-07-15 01:23- CWE-312 - Cleartext Storage of Sensitive Information
| URL | Tags |
|---|---|
| https://www.zeroscience.mk/en/vulnerabilities/ZSL… | third-party-advisory |
| https://exchange.xforce.ibmcloud.com/vulnerabilit… | vdb-entry |
| https://packetstormsecurity.com/files/153501 | exploit |
| Vendor | Product | Version | |
|---|---|---|---|
| iWT Ltd. | FaceSentry Access Control System |
Affected:
6.4.8 build 264
Affected: 5.7.2 build 568 Affected: 5.7.0 build 539 |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2019-25279",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-08T19:25:26.147172Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-08T19:25:30.795Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "FaceSentry Access Control System",
"vendor": "iWT Ltd.",
"versions": [
{
"status": "affected",
"version": "6.4.8 build 264"
},
{
"status": "affected",
"version": "5.7.2 build 568"
},
{
"status": "affected",
"version": "5.7.0 build 539"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:iwt:facesentry_access_control_system:6.4.8_build_264:*:*:*:*:*:*:*",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:iwt:facesentry_access_control_system:5.7.2_build_568:*:*:*:*:*:*:*",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:iwt:facesentry_access_control_system:5.7.0_build_539:*:*:*:*:*:*:*",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "LiquidWorm as Gjoko Krstic of Zero Science Lab"
}
],
"datePublic": "2019-06-30T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "FaceSentry Access Control System 6.4.8 contains a cleartext password storage vulnerability that allows attackers to access unencrypted credentials in the device\u0027s SQLite database. Attackers can directly read sensitive login information stored in /faceGuard/database/FaceSentryWeb.sqlite without additional authentication."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS"
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "Cleartext Storage of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-15T01:23:45.741Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"name": "Zero Science Lab Vulnerability Advisory",
"tags": [
"third-party-advisory"
],
"url": "https://www.zeroscience.mk/en/vulnerabilities/ZSL-2019-5529.php"
},
{
"name": "IBM X-Force Exchange Vulnerability Entry",
"tags": [
"vdb-entry"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/163190"
},
{
"name": "Packet Storm Security Exploit Entry",
"tags": [
"exploit"
],
"url": "https://packetstormsecurity.com/files/153501"
}
],
"title": "FaceSentry Access Control System 6.4.8 Cleartext Password Storage Vulnerability",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2019-25279",
"datePublished": "2026-01-07T23:10:00.907Z",
"dateReserved": "2026-01-06T16:07:08.526Z",
"dateUpdated": "2026-07-15T01:23:45.741Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2019-18238 (GCVE-0-2019-18238)
Vulnerability from cvelistv5 – Published: 2020-02-26 21:19 – Updated: 2024-08-05 01:47- CWE-312 - CLEARTEXT STORAGE OF SENSITIVE INFORMATION CWE-312
| URL | Tags |
|---|---|
| https://www.us-cert.gov/ics/advisories/icsa-20-056-02 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Moxa ioLogik 2500 series firmware, Version 3.0 or lower, IOxpress configuration utility, Version 2.3.0 or lower |
Affected:
Moxa ioLogik 2500 series firmware, Version 3.0 or lower, IOxpress configuration utility, Version 2.3.0 or lower
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T01:47:14.071Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Moxa ioLogik 2500 series firmware, Version 3.0 or lower, IOxpress configuration utility, Version 2.3.0 or lower",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Moxa ioLogik 2500 series firmware, Version 3.0 or lower, IOxpress configuration utility, Version 2.3.0 or lower"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In Moxa ioLogik 2500 series firmware, Version 3.0 or lower, and IOxpress configuration utility, Version 2.3.0 or lower, sensitive information is stored in configuration files without encryption, which may allow an attacker to access an administrative account."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CLEARTEXT STORAGE OF SENSITIVE INFORMATION CWE-312",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-03-24T16:45:16.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-02"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2019-18238",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Moxa ioLogik 2500 series firmware, Version 3.0 or lower, IOxpress configuration utility, Version 2.3.0 or lower",
"version": {
"version_data": [
{
"version_value": "Moxa ioLogik 2500 series firmware, Version 3.0 or lower, IOxpress configuration utility, Version 2.3.0 or lower"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In Moxa ioLogik 2500 series firmware, Version 3.0 or lower, and IOxpress configuration utility, Version 2.3.0 or lower, sensitive information is stored in configuration files without encryption, which may allow an attacker to access an administrative account."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CLEARTEXT STORAGE OF SENSITIVE INFORMATION CWE-312"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-056-02",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-02"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2019-18238",
"datePublished": "2020-02-26T21:19:56.000Z",
"dateReserved": "2019-10-22T00:00:00.000Z",
"dateUpdated": "2024-08-05T01:47:14.071Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-14890 (GCVE-0-2019-14890)
Vulnerability from cvelistv5 – Published: 2019-11-26 06:46 – Updated: 2024-08-05 00:26| URL | Tags |
|---|---|
| https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T00:26:39.098Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2019-14890"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Tower",
"vendor": "[UNKNOWN]",
"versions": [
{
"status": "affected",
"version": "3.6.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Ansible Tower before 3.6.1 where an attacker with low privilege could retrieve usernames and passwords credentials from the new RHSM saved in plain text into the database at \u0027/api/v2/config\u0027 when applying the Ansible Tower license."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-12-02T14:17:50.000Z",
"orgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
"shortName": "redhat"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2019-14890"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secalert@redhat.com",
"ID": "CVE-2019-14890",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Tower",
"version": {
"version_data": [
{
"version_value": "3.6.1"
}
]
}
}
]
},
"vendor_name": "[UNKNOWN]"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability was found in Ansible Tower before 3.6.1 where an attacker with low privilege could retrieve usernames and passwords credentials from the new RHSM saved in plain text into the database at \u0027/api/v2/config\u0027 when applying the Ansible Tower license."
}
]
},
"impact": {
"cvss": [
[
{
"vectorString": "8.4/CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:N",
"version": "3.0"
}
]
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-312"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2019-14890",
"refsource": "CONFIRM",
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2019-14890"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
"assignerShortName": "redhat",
"cveId": "CVE-2019-14890",
"datePublished": "2019-11-26T06:46:17.000Z",
"dateReserved": "2019-08-10T00:00:00.000Z",
"dateUpdated": "2024-08-05T00:26:39.098Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-14886 (GCVE-0-2019-14886)
Vulnerability from cvelistv5 – Published: 2020-03-05 00:00 – Updated: 2024-08-05 00:26| Vendor | Product | Version | |
|---|---|---|---|
| Red Hat | Business-central |
Affected:
versions of Business-central as shipped in rhdm-7.5.1 and rhpam-7.5.1
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T00:26:39.178Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2019-14886"
},
{
"tags": [
"x_transferred"
],
"url": "https://groups.google.com/forum/?utm_medium=email\u0026utm_source=footer#%21msg/jbpm-usage/74pSuwfGKRU/0oXpmRScBQAJ"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Business-central",
"vendor": "Red Hat",
"versions": [
{
"status": "affected",
"version": "versions of Business-central as shipped in rhdm-7.5.1 and rhpam-7.5.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in business-central, as shipped in rhdm-7.5.1 and rhpam-7.5.1, where encoded passwords are stored in errai_security_context. The encoding used for storing the passwords is Base64, not an encryption algorithm, and any recovery of these passwords could lead to user passwords being exposed."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-10-07T00:00:00.000Z",
"orgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
"shortName": "redhat"
},
"references": [
{
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2019-14886"
},
{
"url": "https://groups.google.com/forum/?utm_medium=email\u0026utm_source=footer#%21msg/jbpm-usage/74pSuwfGKRU/0oXpmRScBQAJ"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
"assignerShortName": "redhat",
"cveId": "CVE-2019-14886",
"datePublished": "2020-03-05T00:00:00.000Z",
"dateReserved": "2019-08-10T00:00:00.000Z",
"dateUpdated": "2024-08-05T00:26:39.178Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-14825 (GCVE-0-2019-14825)
Vulnerability from cvelistv5 – Published: 2019-11-25 00:00 – Updated: 2024-08-05 00:26{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T00:26:39.129Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2019-14825"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "katello",
"vendor": "Red Hat",
"versions": [
{
"status": "affected",
"version": "katello versions 3.x.x.x before katello 3.12.0.9"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A cleartext password storage issue was discovered in Katello, versions 3.x.x.x before katello 3.12.0.9. Registry credentials used during container image discovery were inadvertently logged without being masked. This flaw could expose the registry credentials to other privileged users."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:N/A:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-10-07T00:00:00.000Z",
"orgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
"shortName": "redhat"
},
"references": [
{
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2019-14825"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
"assignerShortName": "redhat",
"cveId": "CVE-2019-14825",
"datePublished": "2019-11-25T00:00:00.000Z",
"dateReserved": "2019-08-10T00:00:00.000Z",
"dateUpdated": "2024-08-05T00:26:39.129Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6549 (GCVE-0-2019-6549)
Vulnerability from cvelistv5 – Published: 2019-02-12 18:00 – Updated: 2024-09-16 22:30- CWE-312 - CLEARTEXT STORAGE OF SENSITIVE INFORMATION CWE-312
| URL | Tags |
|---|---|
| https://ics-cert.us-cert.gov/advisories/ICSA-19-036-05 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| ICS-CERT | PR100088 Modbus gateway |
Affected:
All versions prior to Release R02 (or Software Version 1.1.13166)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:23:21.488Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-036-05"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "PR100088 Modbus gateway",
"vendor": "ICS-CERT",
"versions": [
{
"status": "affected",
"version": "All versions prior to Release R02 (or Software Version 1.1.13166)"
}
]
}
],
"datePublic": "2019-02-05T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "An attacker could retrieve plain-text credentials stored in a XML file on PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166) through FTP."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CLEARTEXT STORAGE OF SENSITIVE INFORMATION CWE-312",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-02-12T17:57:01.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-036-05"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2019-02-05T00:00:00",
"ID": "CVE-2019-6549",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PR100088 Modbus gateway",
"version": {
"version_data": [
{
"version_value": "All versions prior to Release R02 (or Software Version 1.1.13166)"
}
]
}
}
]
},
"vendor_name": "ICS-CERT"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An attacker could retrieve plain-text credentials stored in a XML file on PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166) through FTP."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CLEARTEXT STORAGE OF SENSITIVE INFORMATION CWE-312"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-036-05",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-036-05"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2019-6549",
"datePublished": "2019-02-12T18:00:00.000Z",
"dateReserved": "2019-01-22T00:00:00.000Z",
"dateUpdated": "2024-09-16T22:30:41.714Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-3937 (GCVE-0-2019-3937)
Vulnerability from cvelistv5 – Published: 2019-04-30 20:38 – Updated: 2024-08-04 19:26- CWE-312 - Cleartext Storage
| URL | Tags |
|---|---|
| https://www.tenable.com/security/research/tra-2019-20 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Crestron | Crestron AirMedia |
Affected:
AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T19:26:27.781Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Crestron AirMedia",
"vendor": "Crestron",
"versions": [
{
"status": "affected",
"version": "AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 stores usernames, passwords, slideshow passcode, and other configuration options in cleartext in the file /tmp/scfgdndf. A local attacker can use this vulnerability to recover sensitive data."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312: Cleartext Storage",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-04-30T20:38:24.000Z",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2019-3937",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Crestron AirMedia",
"version": {
"version_data": [
{
"version_value": "AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2"
}
]
}
}
]
},
"vendor_name": "Crestron"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 stores usernames, passwords, slideshow passcode, and other configuration options in cleartext in the file /tmp/scfgdndf. A local attacker can use this vulnerability to recover sensitive data."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-312: Cleartext Storage"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2019-20",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2019-3937",
"datePublished": "2019-04-30T20:38:24.000Z",
"dateReserved": "2019-01-03T00:00:00.000Z",
"dateUpdated": "2024-08-04T19:26:27.781Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Mitigation
When storing data in the cloud (e.g., S3 buckets, Azure blobs, Google Cloud Storage, etc.), use the provider's controls to encrypt the data at rest. [REF-1297] [REF-1299] [REF-1301]
Mitigation
In some systems/environments such as cloud, the use of "double encryption" (at both the software and hardware layer) might be required, and the developer might be solely responsible for both layers, instead of shared responsibility with the administrator of the broader system/environment.
CAPEC-37: Retrieve Embedded Sensitive Data
An attacker examines a target system to find sensitive data that has been embedded within it. This information can reveal confidential contents, such as account numbers or individual keys/credentials that can be used as an intermediate step in a larger attack.