CVE-2020-6990 (GCVE-0-2020-6990)

Vulnerability from cvelistv5 – Published: 2020-03-16 15:39 – Updated: 2026-06-03 13:26
VLAI
Summary
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, The cryptographic key utilized to help protect the account password is hard coded into the RSLogix 500 binary file. An attacker could identify cryptographic keys and use it for further cryptographic attacks that could ultimately lead to a remote attacker gaining unauthorized access to the controller.
SSVC
Exploitation: none Automatable: yes Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-321 - USE OF HARD-CODED CRYPTOGRAPHIC KEY CWE-321
Assigner
References
Impacted products
Vendor Product Version
n/a Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior Affected: Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T09:18:02.522Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-20-070-06"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2020-6990",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-03T13:26:22.690361Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-03T13:26:25.620Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, The cryptographic key utilized to help protect the account password is hard coded into the RSLogix 500 binary file. An attacker could identify cryptographic keys and use it for further cryptographic attacks that could ultimately lead to a remote attacker gaining unauthorized access to the controller."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "USE OF HARD-CODED CRYPTOGRAPHIC KEY CWE-321",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-03-16T15:39:45.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-070-06"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2020-6990",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, The cryptographic key utilized to help protect the account password is hard coded into the RSLogix 500 binary file. An attacker could identify cryptographic keys and use it for further cryptographic attacks that could ultimately lead to a remote attacker gaining unauthorized access to the controller."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "USE OF HARD-CODED CRYPTOGRAPHIC KEY CWE-321"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsa-20-070-06",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-070-06"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-6990",
    "datePublished": "2020-03-16T15:39:45.000Z",
    "dateReserved": "2020-01-14T00:00:00.000Z",
    "dateUpdated": "2026-06-03T13:26:25.620Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2020-6983 (GCVE-0-2020-6983)

Vulnerability from cvelistv5 – Published: 2020-03-24 18:57 – Updated: 2024-08-04 09:18
VLAI
Summary
In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the affected products use a hard-coded cryptographic key, which increases the possibility that confidential data can be recovered.
Severity
No CVSS data available.
CWE
  • CWE-321 - USE OF HARD-CODED CRYPTOGRAPHIC KEY CWE-321
Assigner
References
Impacted products
Vendor Product Version
n/a Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower Affected: Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T09:18:02.537Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the affected products use a hard-coded cryptographic key, which increases the possibility that confidential data can be recovered."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "USE OF HARD-CODED CRYPTOGRAPHIC KEY CWE-321",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-03-24T18:57:14.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2020-6983",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the affected products use a hard-coded cryptographic key, which increases the possibility that confidential data can be recovered."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "USE OF HARD-CODED CRYPTOGRAPHIC KEY CWE-321"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-6983",
    "datePublished": "2020-03-24T18:57:14.000Z",
    "dateReserved": "2020-01-14T00:00:00.000Z",
    "dateUpdated": "2024-08-04T09:18:02.537Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-6979 (GCVE-0-2020-6979)

Vulnerability from cvelistv5 – Published: 2020-03-24 20:21 – Updated: 2024-08-04 09:18
VLAI
Summary
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, the affected products use a hard-coded cryptographic key, increasing the possibility that confidential data can be recovered.
Severity
No CVSS data available.
CWE
  • CWE-321 - USE OF HARD-CODED CRYPTOGRAPHIC KEY CWE-321
Assigner
References
Impacted products
Vendor Product Version
n/a Moxa EDS-G516E Series firmware, Version 5.2 or lower Affected: Moxa EDS-G516E Series firmware, Version 5.2 or lower
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T09:18:02.445Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-04"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Moxa EDS-G516E Series firmware, Version 5.2 or lower",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Moxa EDS-G516E Series firmware, Version 5.2 or lower"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "In Moxa EDS-G516E Series firmware, Version 5.2 or lower, the affected products use a hard-coded cryptographic key, increasing the possibility that confidential data can be recovered."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "USE OF HARD-CODED CRYPTOGRAPHIC KEY CWE-321",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-03-24T20:21:41.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-04"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2020-6979",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Moxa EDS-G516E Series firmware, Version 5.2 or lower",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Moxa EDS-G516E Series firmware, Version 5.2 or lower"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In Moxa EDS-G516E Series firmware, Version 5.2 or lower, the affected products use a hard-coded cryptographic key, increasing the possibility that confidential data can be recovered."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "USE OF HARD-CODED CRYPTOGRAPHIC KEY CWE-321"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsa-20-056-04",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-04"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-6979",
    "datePublished": "2020-03-24T20:21:41.000Z",
    "dateReserved": "2020-01-14T00:00:00.000Z",
    "dateUpdated": "2024-08-04T09:18:02.445Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-2500 (GCVE-0-2020-2500)

Vulnerability from cvelistv5 – Published: 2020-07-01 15:53 – Updated: 2024-08-04 07:09
VLAI
Summary
This improper access control vulnerability in Helpdesk allows attackers to get control of QNAP Kayako service. Attackers can access the sensitive data on QNAP Kayako server with API keys. We have replaced the API key to mitigate the vulnerability, and already fixed the issue in Helpdesk 3.0.1 and later versions.
CWE
  • CWE-284 - Improper Access Control
  • CWE-321 - Use of Hard-coded Cryptographic Key
  • CWE-798 - Use of Hard-coded Credentials
Assigner
References
Impacted products
Vendor Product Version
QNAP Systems Inc. Helpdesk Affected: unspecified , < 3.0.1 (custom)
Create a notification for this product.
Credits
Yoni Ramon, security researcher
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T07:09:54.662Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.qnap.com/zh-tw/security-advisory/qsa-20-03"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Helpdesk",
          "vendor": "QNAP Systems Inc.",
          "versions": [
            {
              "lessThan": "3.0.1",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Yoni Ramon, security researcher"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "This improper access control vulnerability in Helpdesk allows attackers to get control of QNAP Kayako service. Attackers can access the sensitive data on QNAP Kayako server with API keys. We have replaced the API key to mitigate the vulnerability, and already fixed the issue in Helpdesk 3.0.1 and later versions."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284 Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "CWE-321 Use of Hard-coded Cryptographic Key",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-798",
              "description": "CWE-798 Use of Hard-coded Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-07-01T15:53:50.000Z",
        "orgId": "2fd009eb-170a-4625-932b-17a53af1051f",
        "shortName": "qnap"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.qnap.com/zh-tw/security-advisory/qsa-20-03"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security@qnap.com",
          "ID": "CVE-2020-2500",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Helpdesk",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "3.0.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "QNAP Systems Inc."
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Yoni Ramon, security researcher"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "This improper access control vulnerability in Helpdesk allows attackers to get control of QNAP Kayako service. Attackers can access the sensitive data on QNAP Kayako server with API keys. We have replaced the API key to mitigate the vulnerability, and already fixed the issue in Helpdesk 3.0.1 and later versions."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284 Improper Access Control"
                }
              ]
            },
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-321 Use of Hard-coded Cryptographic Key"
                }
              ]
            },
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-798 Use of Hard-coded Credentials"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.qnap.com/zh-tw/security-advisory/qsa-20-03",
              "refsource": "MISC",
              "url": "https://www.qnap.com/zh-tw/security-advisory/qsa-20-03"
            }
          ]
        },
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2fd009eb-170a-4625-932b-17a53af1051f",
    "assignerShortName": "qnap",
    "cveId": "CVE-2020-2500",
    "datePublished": "2020-07-01T15:53:50.000Z",
    "dateReserved": "2019-12-09T00:00:00.000Z",
    "dateUpdated": "2024-08-04T07:09:54.662Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-1764 (GCVE-0-2020-1764)

Vulnerability from cvelistv5 – Published: 2020-03-26 11:16 – Updated: 2024-08-04 06:46
VLAI
Summary
A hard-coded cryptographic key vulnerability in the default configuration file was found in Kiali, all versions prior to 1.15.1. A remote attacker could abuse this flaw by creating their own JWT signed tokens and bypass Kiali authentication mechanisms, possibly gaining privileges to view and alter the Istio configuration.
CWE
Assigner
References
Impacted products
Vendor Product Version
Red Hat kiali Affected: all Kiali versions prior to 1.15.1
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T06:46:30.916Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://kiali.io/news/security-bulletins/kiali-security-001/"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2020-1764"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "kiali",
          "vendor": "Red Hat",
          "versions": [
            {
              "status": "affected",
              "version": "all Kiali versions prior to 1.15.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A hard-coded cryptographic key vulnerability in the default configuration file was found in Kiali, all versions prior to 1.15.1. A remote attacker could abuse this flaw by creating their own JWT signed tokens and bypass Kiali authentication mechanisms, possibly gaining privileges to view and alter the Istio configuration."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.6,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "CWE-321",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-03-26T11:16:09.000Z",
        "orgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
        "shortName": "redhat"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://kiali.io/news/security-bulletins/kiali-security-001/"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2020-1764"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secalert@redhat.com",
          "ID": "CVE-2020-1764",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "kiali",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "all Kiali versions prior to 1.15.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Red Hat"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A hard-coded cryptographic key vulnerability in the default configuration file was found in Kiali, all versions prior to 1.15.1. A remote attacker could abuse this flaw by creating their own JWT signed tokens and bypass Kiali authentication mechanisms, possibly gaining privileges to view and alter the Istio configuration."
            }
          ]
        },
        "impact": {
          "cvss": [
            [
              {
                "vectorString": "8.6/CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H",
                "version": "3.0"
              }
            ]
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-321"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kiali.io/news/security-bulletins/kiali-security-001/",
              "refsource": "MISC",
              "url": "https://kiali.io/news/security-bulletins/kiali-security-001/"
            },
            {
              "name": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2020-1764",
              "refsource": "CONFIRM",
              "url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2020-1764"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
    "assignerShortName": "redhat",
    "cveId": "CVE-2020-1764",
    "datePublished": "2020-03-26T11:16:09.000Z",
    "dateReserved": "2019-11-27T00:00:00.000Z",
    "dateUpdated": "2024-08-04T06:46:30.916Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-17098 (GCVE-0-2019-17098)

Vulnerability from cvelistv5 – Published: 2020-09-30 13:05 – Updated: 2024-09-17 03:28
VLAI
Title
Use of Hard-coded Cryptographic Key vulnerability in August Connect Wi-Fi Bridge App
Summary
Use of hard-coded cryptographic key vulnerability in August Connect Wi-Fi Bridge App, Connect Firmware allows an attacker to decrypt an intercepted payload containing the Wi-Fi network authentication credentials. This issue affects: August Connect Wi-Fi Bridge App version v10.11.0 and prior versions on Android. August Connect Firmware version 2.2.12 and prior versions.
CWE
  • CWE-321 - Use of Hard-coded Cryptographic Key
Assigner
References
Impacted products
Vendor Product Version
August Smart Lock and Connect Wi-Fi Bridge App Affected: unspecified , ≤ v10.11.0 (custom)
Create a notification for this product.
August Connect Firmware Affected: unspecified , ≤ 2.2.12 (custom)
Create a notification for this product.
Date Public
2020-09-30 00:00
Credits
Bitdefender Labs
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T01:33:16.921Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://labs.bitdefender.com/2020/08/smart-locks-not-so-smart-with-wi-fi-security/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "platforms": [
            "Android"
          ],
          "product": "Smart Lock and Connect Wi-Fi Bridge App",
          "vendor": "August",
          "versions": [
            {
              "lessThanOrEqual": "v10.11.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Connect Firmware",
          "vendor": "August",
          "versions": [
            {
              "lessThanOrEqual": "2.2.12",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Bitdefender Labs"
        }
      ],
      "datePublic": "2020-09-30T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Use of hard-coded cryptographic key vulnerability in August Connect Wi-Fi Bridge App, Connect Firmware allows an attacker to decrypt an intercepted payload containing the Wi-Fi network authentication credentials. This issue affects: August Connect Wi-Fi Bridge App version v10.11.0 and prior versions on Android. August Connect Firmware version 2.2.12 and prior versions."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 3.5,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "CWE-321 Use of Hard-coded Cryptographic Key",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-09-30T13:05:16.000Z",
        "orgId": "b3d5ebe7-963e-41fb-98e1-2edaeabb8f82",
        "shortName": "Bitdefender"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://labs.bitdefender.com/2020/08/smart-locks-not-so-smart-with-wi-fi-security/"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Updating the Android app fixes the issue."
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Use of Hard-coded Cryptographic Key vulnerability in August Connect Wi-Fi Bridge App",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve-requests@bitdefender.com",
          "DATE_PUBLIC": "2020-09-30T15:00:00.000Z",
          "ID": "CVE-2019-17098",
          "STATE": "PUBLIC",
          "TITLE": "Use of Hard-coded Cryptographic Key vulnerability in August Connect Wi-Fi Bridge App"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Smart Lock and Connect Wi-Fi Bridge App",
                      "version": {
                        "version_data": [
                          {
                            "platform": "Android",
                            "version_affected": "\u003c=",
                            "version_value": "v10.11.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Connect Firmware",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "2.2.12"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "August"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Bitdefender Labs"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Use of hard-coded cryptographic key vulnerability in August Connect Wi-Fi Bridge App, Connect Firmware allows an attacker to decrypt an intercepted payload containing the Wi-Fi network authentication credentials. This issue affects: August Connect Wi-Fi Bridge App version v10.11.0 and prior versions on Android. August Connect Firmware version 2.2.12 and prior versions."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 3.5,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-321 Use of Hard-coded Cryptographic Key"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://labs.bitdefender.com/2020/08/smart-locks-not-so-smart-with-wi-fi-security/",
              "refsource": "MISC",
              "url": "https://labs.bitdefender.com/2020/08/smart-locks-not-so-smart-with-wi-fi-security/"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Updating the Android app fixes the issue."
          }
        ],
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b3d5ebe7-963e-41fb-98e1-2edaeabb8f82",
    "assignerShortName": "Bitdefender",
    "cveId": "CVE-2019-17098",
    "datePublished": "2020-09-30T13:05:16.276Z",
    "dateReserved": "2019-10-02T00:00:00.000Z",
    "dateUpdated": "2024-09-17T03:28:08.464Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-13929 (GCVE-0-2019-13929)

Vulnerability from cvelistv5 – Published: 2019-10-10 13:49 – Updated: 2024-08-05 00:05
VLAI
Summary
A vulnerability has been identified in SIMATIC IT UADM (All versions < V1.3). An authenticated remote attacker with network access to port 1434/tcp of SIMATIC IT UADM could potentially recover a password that can be used to gain read and write access to the related TeamCenter station. The security vulnerability could be exploited only if the attacker is authenticated. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises the confidentiality of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.
Severity
No CVSS data available.
CWE
  • CWE-321 - Use of Hard-coded Cryptographic Key
Assigner
References
Impacted products
Vendor Product Version
Siemens AG SIMATIC IT UADM Affected: All versions < V1.3
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T00:05:43.943Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-984700.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC IT UADM",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.3"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC IT UADM (All versions \u003c V1.3). An authenticated remote attacker with network access to port 1434/tcp of SIMATIC IT UADM could potentially recover a password that can be used to gain read and write access to the related TeamCenter station. The security vulnerability could be exploited only if the attacker is authenticated. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises the confidentiality of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "CWE-321: Use of Hard-coded Cryptographic Key",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-10-10T13:49:24.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-984700.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2019-13929",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC IT UADM",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V1.3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SIMATIC IT UADM (All versions \u003c V1.3). An authenticated remote attacker with network access to port 1434/tcp of SIMATIC IT UADM could potentially recover a password that can be used to gain read and write access to the related TeamCenter station. The security vulnerability could be exploited only if the attacker is authenticated. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises the confidentiality of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-321: Use of Hard-coded Cryptographic Key"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-984700.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-984700.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-13929",
    "datePublished": "2019-10-10T13:49:24.000Z",
    "dateReserved": "2019-07-18T00:00:00.000Z",
    "dateUpdated": "2024-08-05T00:05:43.943Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-10990 (GCVE-0-2019-10990)

Vulnerability from cvelistv5 – Published: 2019-09-23 15:46 – Updated: 2026-06-02 20:07
VLAI
Summary
Red Lion Controls Crimson, version 3.0 and prior and version 3.1 prior to release 3112.00, uses a hard-coded password to encrypt protected files in transit and at rest, which may allow an attacker to access configuration files.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-321 - USE OF HARD-CODED CRYPTOGRAPHIC KEY CWE-321
Assigner
References
Impacted products
Vendor Product Version
n/a Red Lion Controls Crimson (Windows configuration software) Affected: Version 3.0 and prior, Version 3.1 prior to release 3112.00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T22:40:15.501Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-19-248-01"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2019-10990",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-02T20:06:57.948254Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-02T20:07:19.166Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Red Lion Controls Crimson (Windows configuration software)",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Version 3.0 and prior, Version 3.1 prior to release 3112.00"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Red Lion Controls Crimson, version 3.0 and prior and version 3.1 prior to release 3112.00, uses a hard-coded password to encrypt protected files in transit and at rest, which may allow an attacker to access configuration files."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "USE OF HARD-CODED CRYPTOGRAPHIC KEY CWE-321",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-09-23T15:46:43.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-19-248-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2019-10990",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Red Lion Controls Crimson (Windows configuration software)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Version 3.0 and prior, Version 3.1 prior to release 3112.00"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Red Lion Controls Crimson, version 3.0 and prior and version 3.1 prior to release 3112.00, uses a hard-coded password to encrypt protected files in transit and at rest, which may allow an attacker to access configuration files."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "USE OF HARD-CODED CRYPTOGRAPHIC KEY CWE-321"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsa-19-248-01",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsa-19-248-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2019-10990",
    "datePublished": "2019-09-23T15:46:43.000Z",
    "dateReserved": "2019-04-08T00:00:00.000Z",
    "dateUpdated": "2026-06-02T20:07:19.166Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2019-10963 (GCVE-0-2019-10963)

Vulnerability from cvelistv5 – Published: 2019-10-08 18:41 – Updated: 2024-08-04 22:40
VLAI
Summary
Moxa EDR 810, all versions 5.1 and prior, allows an unauthenticated attacker to be able to retrieve some log files from the device, which may allow sensitive information disclosure. Log files must have previously been exported by a legitimate user.
Severity
No CVSS data available.
CWE
  • CWE-321 - USE OF HARD-CODED CRYPTOGRAPHIC KEY CWE-321
Assigner
References
Impacted products
Vendor Product Version
n/a Moxa EDR 810 Affected: All versions 5.1 and prior
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T22:40:15.565Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-19-274-03"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://packetstormsecurity.com/files/154943/Moxa-EDR-810-Command-Injection-Information-Disclosure.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Moxa EDR 810",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "All versions 5.1 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Moxa EDR 810, all versions 5.1 and prior, allows an unauthenticated attacker to be able to retrieve some log files from the device, which may allow sensitive information disclosure. Log files must have previously been exported by a legitimate user."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "USE OF HARD-CODED CRYPTOGRAPHIC KEY CWE-321",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-10-23T19:06:27.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-19-274-03"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://packetstormsecurity.com/files/154943/Moxa-EDR-810-Command-Injection-Information-Disclosure.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2019-10963",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Moxa EDR 810",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions 5.1 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Moxa EDR 810, all versions 5.1 and prior, allows an unauthenticated attacker to be able to retrieve some log files from the device, which may allow sensitive information disclosure. Log files must have previously been exported by a legitimate user."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "USE OF HARD-CODED CRYPTOGRAPHIC KEY CWE-321"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsa-19-274-03",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsa-19-274-03"
            },
            {
              "name": "http://packetstormsecurity.com/files/154943/Moxa-EDR-810-Command-Injection-Information-Disclosure.html",
              "refsource": "MISC",
              "url": "http://packetstormsecurity.com/files/154943/Moxa-EDR-810-Command-Injection-Information-Disclosure.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2019-10963",
    "datePublished": "2019-10-08T18:41:43.000Z",
    "dateReserved": "2019-04-08T00:00:00.000Z",
    "dateUpdated": "2024-08-04T22:40:15.565Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-10920 (GCVE-0-2019-10920)

Vulnerability from cvelistv5 – Published: 2019-05-14 19:54 – Updated: 2024-08-04 22:40
VLAI
Summary
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Project data stored on the device, which is accessible via port 10005/tcp, can be decrypted due to a hardcoded encryption key. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
Severity
No CVSS data available.
CWE
  • CWE-321 - Use of Hard-coded Cryptographic Key
Assigner
References
Impacted products
Vendor Product Version
Siemens LOGO! 8 BM (incl. SIPLUS variants) Affected: All versions < V8.3
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T22:40:15.342Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "108382",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/108382"
          },
          {
            "name": "20190529 [SYSS-2019-012]: Siemens LOGO! 8 - Use of Hard-coded Cryptographic Key (CWE-321)",
            "tags": [
              "mailing-list",
              "x_refsource_BUGTRAQ",
              "x_transferred"
            ],
            "url": "https://seclists.org/bugtraq/2019/May/72"
          },
          {
            "name": "20190529 [SYSS-2019-012]: Siemens LOGO! 8 - Use of Hard-coded Cryptographic Key (CWE-321)",
            "tags": [
              "mailing-list",
              "x_refsource_FULLDISC",
              "x_transferred"
            ],
            "url": "http://seclists.org/fulldisclosure/2019/May/44"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-542701.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://packetstormsecurity.com/files/153122/Siemens-LOGO-8-Hard-Coded-Cryptographic-Key.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "LOGO! 8 BM (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.3"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions \u003c V8.3). Project data stored on the device, which is accessible via port 10005/tcp, can be decrypted due to a hardcoded encryption key. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "CWE-321: Use of Hard-coded Cryptographic Key",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-12-14T21:05:17.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "name": "108382",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/108382"
        },
        {
          "name": "20190529 [SYSS-2019-012]: Siemens LOGO! 8 - Use of Hard-coded Cryptographic Key (CWE-321)",
          "tags": [
            "mailing-list",
            "x_refsource_BUGTRAQ"
          ],
          "url": "https://seclists.org/bugtraq/2019/May/72"
        },
        {
          "name": "20190529 [SYSS-2019-012]: Siemens LOGO! 8 - Use of Hard-coded Cryptographic Key (CWE-321)",
          "tags": [
            "mailing-list",
            "x_refsource_FULLDISC"
          ],
          "url": "http://seclists.org/fulldisclosure/2019/May/44"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-542701.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://packetstormsecurity.com/files/153122/Siemens-LOGO-8-Hard-Coded-Cryptographic-Key.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2019-10920",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "LOGO! 8 BM (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions \u003c V8.3). Project data stored on the device, which is accessible via port 10005/tcp, can be decrypted due to a hardcoded encryption key. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-321: Use of Hard-coded Cryptographic Key"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "108382",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/108382"
            },
            {
              "name": "20190529 [SYSS-2019-012]: Siemens LOGO! 8 - Use of Hard-coded Cryptographic Key (CWE-321)",
              "refsource": "BUGTRAQ",
              "url": "https://seclists.org/bugtraq/2019/May/72"
            },
            {
              "name": "20190529 [SYSS-2019-012]: Siemens LOGO! 8 - Use of Hard-coded Cryptographic Key (CWE-321)",
              "refsource": "FULLDISC",
              "url": "http://seclists.org/fulldisclosure/2019/May/44"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-542701.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-542701.pdf"
            },
            {
              "name": "http://packetstormsecurity.com/files/153122/Siemens-LOGO-8-Hard-Coded-Cryptographic-Key.html",
              "refsource": "MISC",
              "url": "http://packetstormsecurity.com/files/153122/Siemens-LOGO-8-Hard-Coded-Cryptographic-Key.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-10920",
    "datePublished": "2019-05-14T19:54:48.000Z",
    "dateReserved": "2019-04-08T00:00:00.000Z",
    "dateUpdated": "2024-08-04T22:40:15.342Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation
Architecture and Design

Prevention schemes mirror that of hard-coded password storage.

No CAPEC attack patterns related to this CWE.