Common Weakness Enumeration

CWE-321

Allowed

Use of Hard-coded Cryptographic Key

Abstraction: Variant · Status: Draft

The product uses a hard-coded, unchangeable cryptographic key.

503 vulnerabilities reference this CWE, most recent first.

CVE-2021-38461 (GCVE-0-2021-38461)

Vulnerability from cvelistv5 – Published: 2021-10-22 11:23 – Updated: 2024-09-16 21:56
VLAI
Title
AUVESY Versiondog
Summary
The affected product uses a hard-coded blowfish key for encryption/decryption processes. The key can be easily extracted from binaries.
CWE
  • CWE-321 - Use of Hard-coded Cryptographic Key
Assigner
References
Impacted products
Vendor Product Version
AUVESY Versiondog Affected: All , ≤ 8.0 (custom)
Create a notification for this product.
Date Public
2021-08-19 00:00
Credits
Amir Preminger of Claroty reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:44:22.933Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-292-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Versiondog",
          "vendor": "AUVESY",
          "versions": [
            {
              "lessThanOrEqual": "8.0",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Amir Preminger of Claroty reported these vulnerabilities to CISA."
        }
      ],
      "datePublic": "2021-08-19T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "The affected product uses a hard-coded blowfish key for encryption/decryption processes. The key can be easily extracted from binaries."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "CWE-321 Use of Hard-coded Cryptographic Key",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-10-22T11:23:18.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-292-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "AUVESY recommends upgrading Versiondog to Version 8.1 or later (login required)."
        }
      ],
      "source": {
        "advisory": "https://us-cert.cisa.gov/ics/advisories/icsa-21-292-01",
        "discovery": "UNKNOWN"
      },
      "title": "AUVESY Versiondog",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2021-08-19T15:34:00.000Z",
          "ID": "CVE-2021-38461",
          "STATE": "PUBLIC",
          "TITLE": "AUVESY Versiondog"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Versiondog",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "All",
                            "version_value": "8.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "AUVESY"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Amir Preminger of Claroty reported these vulnerabilities to CISA."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The affected product uses a hard-coded blowfish key for encryption/decryption processes. The key can be easily extracted from binaries."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-321 Use of Hard-coded Cryptographic Key"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-292-01",
              "refsource": "CONFIRM",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-292-01"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "AUVESY recommends upgrading Versiondog to Version 8.1 or later (login required)."
          }
        ],
        "source": {
          "advisory": "https://us-cert.cisa.gov/ics/advisories/icsa-21-292-01",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-38461",
    "datePublished": "2021-10-22T11:23:18.809Z",
    "dateReserved": "2021-08-10T00:00:00.000Z",
    "dateUpdated": "2024-09-16T21:56:39.301Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-32520 (GCVE-0-2021-32520)

Vulnerability from cvelistv5 – Published: 2021-07-07 14:12 – Updated: 2024-09-17 03:37
VLAI
Title
QSAN Storage Manager - Use of Hard-coded Cryptographic Key
Summary
Use of hard-coded cryptographic key vulnerability in QSAN Storage Manager allows attackers to obtain users’ credentials and related permissions. Suggest contacting with QSAN and refer to recommendations in QSAN Document.
CWE
  • CWE-321 - Use of Hard-coded Cryptographic Key
Assigner
References
Impacted products
Vendor Product Version
QSAN Storage Manager Affected: unspecified , ≤ 3.3.1 (custom)
Create a notification for this product.
Date Public
2021-07-07 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:25:29.769Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.twcert.org.tw/tw/cp-132-4876-8da07-1.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Storage Manager",
          "vendor": "QSAN",
          "versions": [
            {
              "lessThanOrEqual": "3.3.1",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-07-07T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Use of hard-coded cryptographic key vulnerability in QSAN Storage Manager allows attackers to obtain users\u2019 credentials and related permissions. Suggest contacting with QSAN and refer to recommendations in QSAN Document."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "CWE-321 Use of Hard-coded Cryptographic Key",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-07-22T10:32:45.000Z",
        "orgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
        "shortName": "twcert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.twcert.org.tw/tw/cp-132-4876-8da07-1.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Please refer to QSANS\u0027s recommended measures"
        }
      ],
      "source": {
        "advisory": "TVN-202104025",
        "discovery": "EXTERNAL"
      },
      "title": "QSAN Storage Manager - Use of Hard-coded Cryptographic Key",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "AKA": "TWCERT/CC",
          "ASSIGNER": "cve@cert.org.tw",
          "DATE_PUBLIC": "2021-07-07T11:33:00.000Z",
          "ID": "CVE-2021-32520",
          "STATE": "PUBLIC",
          "TITLE": "QSAN Storage Manager - Use of Hard-coded Cryptographic Key"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Storage Manager",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "3.3.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "QSAN"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Use of hard-coded cryptographic key vulnerability in QSAN Storage Manager allows attackers to obtain users\u2019 credentials and related permissions. Suggest contacting with QSAN and refer to recommendations in QSAN Document."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-321 Use of Hard-coded Cryptographic Key"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.twcert.org.tw/tw/cp-132-4876-8da07-1.html",
              "refsource": "MISC",
              "url": "https://www.twcert.org.tw/tw/cp-132-4876-8da07-1.html"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Please refer to QSANS\u0027s recommended measures"
          }
        ],
        "source": {
          "advisory": "TVN-202104025",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
    "assignerShortName": "twcert",
    "cveId": "CVE-2021-32520",
    "datePublished": "2021-07-07T14:12:01.681Z",
    "dateReserved": "2021-05-10T00:00:00.000Z",
    "dateUpdated": "2024-09-17T03:37:44.199Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-27481 (GCVE-0-2021-27481)

Vulnerability from cvelistv5 – Published: 2021-06-16 11:59 – Updated: 2024-08-03 20:48
VLAI
Summary
ZOLL Defibrillator Dashboard, v prior to 2.2, The affected products utilize an encryption key in the data exchange process, which is hardcoded. This could allow an attacker to gain access to sensitive information.
Severity
No CVSS data available.
CWE
  • CWE-321 - USE OF HARD-CODED CRYPTOGRAPHIC KEY CWE-321
Assigner
References
Impacted products
Vendor Product Version
n/a ZOLL Defibrillator Dashboard Affected: All versions prior to 2.2
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T20:48:17.256Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsma-21-161-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "ZOLL Defibrillator Dashboard",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "All versions prior to 2.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "ZOLL Defibrillator Dashboard, v prior to 2.2, The affected products utilize an encryption key in the data exchange process, which is hardcoded. This could allow an attacker to gain access to sensitive information."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "USE OF HARD-CODED CRYPTOGRAPHIC KEY CWE-321",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-06-16T11:59:39.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsma-21-161-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2021-27481",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "ZOLL Defibrillator Dashboard",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions prior to 2.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "ZOLL Defibrillator Dashboard, v prior to 2.2, The affected products utilize an encryption key in the data exchange process, which is hardcoded. This could allow an attacker to gain access to sensitive information."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "USE OF HARD-CODED CRYPTOGRAPHIC KEY CWE-321"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsma-21-161-01",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsma-21-161-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-27481",
    "datePublished": "2021-06-16T11:59:39.000Z",
    "dateReserved": "2021-02-19T00:00:00.000Z",
    "dateUpdated": "2024-08-03T20:48:17.256Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-27392 (GCVE-0-2021-27392)

Vulnerability from cvelistv5 – Published: 2021-04-22 20:42 – Updated: 2024-08-03 20:48
VLAI
Summary
A vulnerability has been identified in Siveillance Video Open Network Bridge (2020 R3), Siveillance Video Open Network Bridge (2020 R2), Siveillance Video Open Network Bridge (2020 R1), Siveillance Video Open Network Bridge (2019 R3), Siveillance Video Open Network Bridge (2019 R2), Siveillance Video Open Network Bridge (2019 R1), Siveillance Video Open Network Bridge (2018 R3), Siveillance Video Open Network Bridge (2018 R2). Affected Open Network Bridges store user credentials for the authentication between ONVIF clients and ONVIF server using a hard-coded key. The encrypted credentials can be retrieved via the MIP SDK. This could allow an authenticated remote attacker to retrieve and decrypt all credentials stored on the ONVIF server.
Severity
No CVSS data available.
CWE
  • CWE-321 - Use of Hard-coded Cryptographic Key
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T20:48:16.928Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-853866.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Siveillance Video Open Network Bridge",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "2020 R3"
            }
          ]
        },
        {
          "product": "Siveillance Video Open Network Bridge",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "2020 R2"
            }
          ]
        },
        {
          "product": "Siveillance Video Open Network Bridge",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "2020 R1"
            }
          ]
        },
        {
          "product": "Siveillance Video Open Network Bridge",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "2019 R3"
            }
          ]
        },
        {
          "product": "Siveillance Video Open Network Bridge",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "2019 R2"
            }
          ]
        },
        {
          "product": "Siveillance Video Open Network Bridge",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "2019 R1"
            }
          ]
        },
        {
          "product": "Siveillance Video Open Network Bridge",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "2018 R3"
            }
          ]
        },
        {
          "product": "Siveillance Video Open Network Bridge",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "2018 R2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Siveillance Video Open Network Bridge (2020 R3), Siveillance Video Open Network Bridge (2020 R2), Siveillance Video Open Network Bridge (2020 R1), Siveillance Video Open Network Bridge (2019 R3), Siveillance Video Open Network Bridge (2019 R2), Siveillance Video Open Network Bridge (2019 R1), Siveillance Video Open Network Bridge (2018 R3), Siveillance Video Open Network Bridge (2018 R2). Affected Open Network Bridges store user credentials for the authentication between ONVIF clients and ONVIF server using a hard-coded key. The encrypted credentials can be retrieved via the MIP SDK. This could allow an authenticated remote attacker to retrieve and decrypt all credentials stored on the ONVIF server."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "CWE-321: Use of Hard-coded Cryptographic Key",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-04-22T20:42:21.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-853866.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-27392",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Siveillance Video Open Network Bridge",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "2020 R3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Siveillance Video Open Network Bridge",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "2020 R2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Siveillance Video Open Network Bridge",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "2020 R1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Siveillance Video Open Network Bridge",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "2019 R3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Siveillance Video Open Network Bridge",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "2019 R2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Siveillance Video Open Network Bridge",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "2019 R1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Siveillance Video Open Network Bridge",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "2018 R3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Siveillance Video Open Network Bridge",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "2018 R2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Siveillance Video Open Network Bridge (2020 R3), Siveillance Video Open Network Bridge (2020 R2), Siveillance Video Open Network Bridge (2020 R1), Siveillance Video Open Network Bridge (2019 R3), Siveillance Video Open Network Bridge (2019 R2), Siveillance Video Open Network Bridge (2019 R1), Siveillance Video Open Network Bridge (2018 R3), Siveillance Video Open Network Bridge (2018 R2). Affected Open Network Bridges store user credentials for the authentication between ONVIF clients and ONVIF server using a hard-coded key. The encrypted credentials can be retrieved via the MIP SDK. This could allow an authenticated remote attacker to retrieve and decrypt all credentials stored on the ONVIF server."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-321: Use of Hard-coded Cryptographic Key"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-853866.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-853866.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-27392",
    "datePublished": "2021-04-22T20:42:21.000Z",
    "dateReserved": "2021-02-18T00:00:00.000Z",
    "dateUpdated": "2024-08-03T20:48:16.928Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-27389 (GCVE-0-2021-27389)

Vulnerability from cvelistv5 – Published: 2021-04-22 20:42 – Updated: 2024-08-03 20:48
VLAI
Summary
A vulnerability has been identified in Opcenter Quality (All versions < V12.2), QMS Automotive (All versions < V12.30). A private sign key is shipped with the product without adequate protection.
Severity
No CVSS data available.
CWE
  • CWE-321 - Use of Hard-coded Cryptographic Key
Assigner
References
Impacted products
Vendor Product Version
Siemens Opcenter Quality Affected: All versions < V12.2
Create a notification for this product.
Siemens QMS Automotive Affected: All versions < V12.30
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T20:48:16.625Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-788287.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Opcenter Quality",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V12.2"
            }
          ]
        },
        {
          "product": "QMS Automotive",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V12.30"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Opcenter Quality (All versions \u003c V12.2), QMS Automotive (All versions \u003c V12.30). A private sign key is shipped with the product without adequate protection."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "CWE-321: Use of Hard-coded Cryptographic Key",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-04-22T20:42:21.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-788287.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-27389",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Opcenter Quality",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V12.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "QMS Automotive",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V12.30"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Opcenter Quality (All versions \u003c V12.2), QMS Automotive (All versions \u003c V12.30). A private sign key is shipped with the product without adequate protection."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-321: Use of Hard-coded Cryptographic Key"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-788287.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-788287.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-27389",
    "datePublished": "2021-04-22T20:42:21.000Z",
    "dateReserved": "2021-02-18T00:00:00.000Z",
    "dateUpdated": "2024-08-03T20:48:16.625Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-23842 (GCVE-0-2021-23842)

Vulnerability from cvelistv5 – Published: 2022-01-19 20:38 – Updated: 2024-09-16 21:56
VLAI
Title
Use of Hard-coded Cryptographic Key
Summary
Communication to the AMC2 uses a state-of-the-art cryptographic algorithm for symmetric encryption called Blowfish. An attacker could retrieve the key from the firmware to decrypt network traffic between the AMC2 and the host system. Thus, an attacker can exploit this vulnerability to decrypt and modify network traffic, decrypt and further investigate the device\'s firmware file, and change the device configuration. The attacker needs to have access to the local network, typically even the same subnet.
CWE
  • CWE-321 - Use of Hard-coded Cryptographic Key
Assigner
References
Impacted products
Vendor Product Version
Bosch AMS Affected: unspecified , < 4.0 (custom)
Create a notification for this product.
Bosch APE Affected: unspecified , ≤ 3.8.x (custom)
Create a notification for this product.
Bosch BIS Affected: unspecified , < 4.9.1 (custom)
Create a notification for this product.
Bosch AMC2 Affected: all
Create a notification for this product.
Date Public
2022-01-19 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T19:14:09.336Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-940448-BT.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AMS",
          "vendor": "Bosch",
          "versions": [
            {
              "lessThan": "4.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "APE",
          "vendor": "Bosch",
          "versions": [
            {
              "lessThanOrEqual": "3.8.x",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "BIS",
          "vendor": "Bosch",
          "versions": [
            {
              "lessThan": "4.9.1",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "AMC2",
          "vendor": "Bosch",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        }
      ],
      "datePublic": "2022-01-19T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Communication to the AMC2 uses a state-of-the-art cryptographic algorithm for symmetric encryption called Blowfish. An attacker could retrieve the key from the firmware to decrypt network traffic between the AMC2 and the host system. Thus, an attacker can exploit this vulnerability to decrypt and modify network traffic, decrypt and further investigate the device\\\u0027s firmware file, and change the device configuration. The attacker needs to have access to the local network, typically even the same subnet."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "CWE-321 Use of Hard-coded Cryptographic Key",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-01-19T20:38:54.000Z",
        "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "shortName": "bosch"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-940448-BT.html"
        }
      ],
      "source": {
        "advisory": "BOSCH-SA-940448-BT",
        "discovery": "EXTERNAL"
      },
      "title": "Use of Hard-coded Cryptographic Key",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@bosch.com",
          "DATE_PUBLIC": "2022-01-19",
          "ID": "CVE-2021-23842",
          "STATE": "PUBLIC",
          "TITLE": "Use of Hard-coded Cryptographic Key"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "AMS",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APE",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "3.8.x"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "BIS",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.9.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "AMC2",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Bosch"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Communication to the AMC2 uses a state-of-the-art cryptographic algorithm for symmetric encryption called Blowfish. An attacker could retrieve the key from the firmware to decrypt network traffic between the AMC2 and the host system. Thus, an attacker can exploit this vulnerability to decrypt and modify network traffic, decrypt and further investigate the device\\\u0027s firmware file, and change the device configuration. The attacker needs to have access to the local network, typically even the same subnet."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-321 Use of Hard-coded Cryptographic Key"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-940448-BT.html",
              "refsource": "CONFIRM",
              "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-940448-BT.html"
            }
          ]
        },
        "source": {
          "advisory": "BOSCH-SA-940448-BT",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
    "assignerShortName": "bosch",
    "cveId": "CVE-2021-23842",
    "datePublished": "2022-01-19T20:38:54.368Z",
    "dateReserved": "2021-01-12T00:00:00.000Z",
    "dateUpdated": "2024-09-16T21:56:51.896Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-4228 (GCVE-0-2021-4228)

Vulnerability from cvelistv5 – Published: 2022-10-24 00:00 – Updated: 2025-05-05 20:28
VLAI
Title
Hard-coded TLS Certificate
Summary
Use of hard-coded TLS certificate by default allows an attacker to perform Man-in-the-Middle (MitM) attacks even in the presence of the HTTPS connection. This issue affects: Lanner Inc IAC-AST2500A standard firmware version 1.00.0.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-321 - Use of Hard-coded Cryptographic Key
Assigner
Impacted products
Vendor Product Version
Lanner Inc IAC-AST2500A Affected: 1.00.0
Create a notification for this product.
Credits
Andrea Palanca of Nozomi Networks found this bug during a security research activity.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T17:23:08.901Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/vulnerabilities-in-bmc-firmware-affect-ot-iot-device-security-part-1/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/labs/vulnerability-advisories/cve-2021-4228/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2021-4228",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-05T20:28:02.446069Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-05-05T20:28:17.148Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "IAC-AST2500A",
          "vendor": "Lanner Inc",
          "versions": [
            {
              "status": "affected",
              "version": "1.00.0"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Andrea Palanca of Nozomi Networks found this bug during a security research activity."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Use of hard-coded TLS certificate by default allows an attacker to perform Man-in-the-Middle (MitM) attacks even in the presence of the HTTPS connection. This issue affects: Lanner Inc IAC-AST2500A standard firmware version 1.00.0."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "CWE-321 Use of Hard-coded Cryptographic Key",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-01T00:00:00.000Z",
        "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "shortName": "Nozomi"
      },
      "references": [
        {
          "url": "https://www.nozominetworks.com/blog/vulnerabilities-in-bmc-firmware-affect-ot-iot-device-security-part-1/"
        },
        {
          "url": "https://www.nozominetworks.com/labs/vulnerability-advisories/cve-2021-4228/"
        }
      ],
      "source": {
        "advisory": "https://www.nozominetworks.com/labs/vulnerability-advisories/cve-2021-4228/",
        "discovery": "EXTERNAL"
      },
      "title": "Hard-coded TLS Certificate",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
    "assignerShortName": "Nozomi",
    "cveId": "CVE-2021-4228",
    "datePublished": "2022-10-24T00:00:00.000Z",
    "dateReserved": "2022-05-13T00:00:00.000Z",
    "dateUpdated": "2025-05-05T20:28:17.148Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-0266 (GCVE-0-2021-0266)

Vulnerability from cvelistv5 – Published: 2021-04-22 19:37 – Updated: 2024-09-17 03:13
VLAI
Title
cSRX: Use of Hard-coded Cryptographic Keys allows an attacker to take control of the device through device management services.
Summary
The use of multiple hard-coded cryptographic keys in cSRX Series software in Juniper Networks Junos OS allows an attacker to take control of any instance of a cSRX deployment through device management services. This issue affects: Juniper Networks Junos OS on cSRX Series: All versions prior to 20.2R3; 20.3 versions prior to 20.3R2; 20.4 versions prior to 20.4R2.
CWE
  • CWE-321 - Use of Hard-coded Cryptographic Keys
Assigner
References
URL Tags
https://kb.juniper.net/JSA11157 x_refsource_MISC
Impacted products
Vendor Product Version
Juniper Networks Junos OS Affected: unspecified , < 20.2R3 (custom)
Affected: 20.3 , < 20.3R2 (custom)
Affected: 20.4 , < 20.4R2 (custom)
Create a notification for this product.
Date Public
2021-04-14 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T15:32:10.505Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://kb.juniper.net/JSA11157"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "platforms": [
            "cSRX Series"
          ],
          "product": "Junos OS",
          "vendor": "Juniper Networks",
          "versions": [
            {
              "lessThan": "20.2R3",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            },
            {
              "lessThan": "20.3R2",
              "status": "affected",
              "version": "20.3",
              "versionType": "custom"
            },
            {
              "lessThan": "20.4R2",
              "status": "affected",
              "version": "20.4",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-04-14T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "The use of multiple hard-coded cryptographic keys in cSRX Series software in Juniper Networks Junos OS allows an attacker to take control of any instance of a cSRX deployment through device management services. This issue affects: Juniper Networks Junos OS on cSRX Series: All versions prior to 20.2R3; 20.3 versions prior to 20.3R2; 20.4 versions prior to 20.4R2."
        }
      ],
      "exploits": [
        {
          "lang": "en",
          "value": "Juniper SIRT is not aware of any malicious exploitation of this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "CWE-321 Use of Hard-coded Cryptographic Keys",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-04-22T19:37:23.000Z",
        "orgId": "8cbe9d5a-a066-4c94-8978-4b15efeae968",
        "shortName": "juniper"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://kb.juniper.net/JSA11157"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "The following software releases have been updated to resolve this specific issue: 20.2R3, 20.3R2, 20.4R2, 21.1R1, and all subsequent releases."
        }
      ],
      "source": {
        "advisory": "JSA11157",
        "defect": [
          "1564611"
        ],
        "discovery": "INTERNAL"
      },
      "title": "cSRX: Use of Hard-coded Cryptographic Keys allows an attacker to take control of the device through device management services.",
      "workarounds": [
        {
          "lang": "en",
          "value": "There are no viable workarounds for this issue. \n\nTo reduce the risk of exploitation of this issue, use access lists or firewall filters to limit access to the cSRX instance to only trusted administrative networks, hosts and users."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "sirt@juniper.net",
          "DATE_PUBLIC": "2021-04-14T16:00:00.000Z",
          "ID": "CVE-2021-0266",
          "STATE": "PUBLIC",
          "TITLE": "cSRX: Use of Hard-coded Cryptographic Keys allows an attacker to take control of the device through device management services."
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Junos OS",
                      "version": {
                        "version_data": [
                          {
                            "platform": "cSRX Series",
                            "version_affected": "\u003c",
                            "version_value": "20.2R3"
                          },
                          {
                            "platform": "cSRX Series",
                            "version_affected": "\u003c",
                            "version_name": "20.3",
                            "version_value": "20.3R2"
                          },
                          {
                            "platform": "cSRX Series",
                            "version_affected": "\u003c",
                            "version_name": "20.4",
                            "version_value": "20.4R2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Juniper Networks"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The use of multiple hard-coded cryptographic keys in cSRX Series software in Juniper Networks Junos OS allows an attacker to take control of any instance of a cSRX deployment through device management services. This issue affects: Juniper Networks Junos OS on cSRX Series: All versions prior to 20.2R3; 20.3 versions prior to 20.3R2; 20.4 versions prior to 20.4R2."
            }
          ]
        },
        "exploit": [
          {
            "lang": "en",
            "value": "Juniper SIRT is not aware of any malicious exploitation of this vulnerability."
          }
        ],
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-321 Use of Hard-coded Cryptographic Keys"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kb.juniper.net/JSA11157",
              "refsource": "MISC",
              "url": "https://kb.juniper.net/JSA11157"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "The following software releases have been updated to resolve this specific issue: 20.2R3, 20.3R2, 20.4R2, 21.1R1, and all subsequent releases."
          }
        ],
        "source": {
          "advisory": "JSA11157",
          "defect": [
            "1564611"
          ],
          "discovery": "INTERNAL"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "There are no viable workarounds for this issue. \n\nTo reduce the risk of exploitation of this issue, use access lists or firewall filters to limit access to the cSRX instance to only trusted administrative networks, hosts and users."
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8cbe9d5a-a066-4c94-8978-4b15efeae968",
    "assignerShortName": "juniper",
    "cveId": "CVE-2021-0266",
    "datePublished": "2021-04-22T19:37:23.655Z",
    "dateReserved": "2020-10-27T00:00:00.000Z",
    "dateUpdated": "2024-09-17T03:13:48.705Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-28395 (GCVE-0-2020-28395)

Vulnerability from cvelistv5 – Published: 2021-01-12 00:00 – Updated: 2024-08-04 16:33
VLAI
Summary
A vulnerability has been identified in SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.0). Devices do not create a new unique private key after factory reset. An attacker could leverage this situation to a man-in-the-middle situation and decrypt previously captured traffic.
Severity
No CVSS data available.
CWE
  • CWE-321 - Use of Hard-coded Cryptographic Key
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:33:59.028Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-274900.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SCALANCE X-200RNA switch family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.7"
            }
          ]
        },
        {
          "product": "SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SCALANCE X-200RNA switch family (All versions \u003c V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions \u003c V4.1.0). Devices do not create a new unique private key after factory reset. An attacker could leverage this situation to a man-in-the-middle situation and decrypt previously captured traffic."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "CWE-321: Use of Hard-coded Cryptographic Key",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-13T00:00:00.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-274900.pdf"
        },
        {
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-02"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-28395",
    "datePublished": "2021-01-12T00:00:00.000Z",
    "dateReserved": "2020-11-10T00:00:00.000Z",
    "dateUpdated": "2024-08-04T16:33:59.028Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-28391 (GCVE-0-2020-28391)

Vulnerability from cvelistv5 – Published: 2021-01-12 00:00 – Updated: 2024-08-04 16:33
VLAI
Summary
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7). Devices create a new unique key upon factory reset, except when used with C-PLUG. When used with C-PLUG the devices use the hardcoded private RSA-key shipped with the firmware-image. An attacker could leverage this situation to a man-in-the-middle situation and decrypt previously captured traffic.
Severity
No CVSS data available.
CWE
  • CWE-321 - Use of Hard-coded Cryptographic Key
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:33:59.106Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-274900.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SCALANCE X-200 switch family (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "product": "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.0"
            }
          ]
        },
        {
          "product": "SCALANCE X-200RNA switch family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.7"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions \u003c V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.5.0), SCALANCE X-200RNA switch family (All versions \u003c V3.2.7). Devices create a new unique key upon factory reset, except when used with C-PLUG. When used with C-PLUG the devices use the hardcoded private RSA-key shipped with the firmware-image. An attacker could leverage this situation to a man-in-the-middle situation and decrypt previously captured traffic."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "CWE-321: Use of Hard-coded Cryptographic Key",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-13T00:00:00.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-274900.pdf"
        },
        {
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-02"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-28391",
    "datePublished": "2021-01-12T00:00:00.000Z",
    "dateReserved": "2020-11-10T00:00:00.000Z",
    "dateUpdated": "2024-08-04T16:33:59.106Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation
Architecture and Design

Prevention schemes mirror that of hard-coded password storage.

No CAPEC attack patterns related to this CWE.