CWE-121

Stack-based Buffer Overflow

A stack-based buffer overflow condition is a condition where the buffer being overwritten is allocated on the stack (i.e., is a local variable or, rarely, a parameter to a function).

CVE-2024-10123 (GCVE-0-2024-10123)

Vulnerability from cvelistv5 – Published: 2024-10-18 19:31 – Updated: 2024-10-18 20:42
VLAI
Title
Tenda AC8 saveParentControlInfo compare_parentcontrol_time stack-based overflow
Summary
A vulnerability was found in Tenda AC8 16.03.34.06. It has been declared as critical. Affected by this vulnerability is the function compare_parentcontrol_time of the file /goform/saveParentControlInfo. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. This is not the same issue like CVE-2023-33671. The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.280915 vdb-entrytechnical-description
https://vuldb.com/?ctiid.280915 signaturepermissions-required
https://vuldb.com/?submit.421340 third-party-advisory
https://github.com/JohenanLi/router_vuls/blob/mai… exploit
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda AC8 Affected: 16.03.34.06
Create a notification for this product.
tenda ac8_firmware Affected: 16.03.34.06
    cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*
Create a notification for this product.
Credits
minipython (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac8_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "16.03.34.06"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-10123",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-18T20:42:10.984477Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-18T20:42:45.158Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC8",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.34.06"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "minipython (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC8 16.03.34.06. It has been declared as critical. Affected by this vulnerability is the function compare_parentcontrol_time of the file /goform/saveParentControlInfo. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. This is not the same issue like CVE-2023-33671. The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In Tenda AC8 16.03.34.06 wurde eine kritische Schwachstelle ausgemacht. Es geht um die Funktion compare_parentcontrol_time der Datei /goform/saveParentControlInfo. Durch Manipulieren des Arguments time mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-18T19:31:05.643Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-280915 | Tenda AC8 saveParentControlInfo compare_parentcontrol_time stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.280915"
        },
        {
          "name": "VDB-280915 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.280915"
        },
        {
          "name": "Submit #421340 | Tenda AC8v4 V16.03.34.06 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.421340"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/JohenanLi/router_vuls/blob/main/ac8v4/compare_parentcontrol_time_vul.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-10-18T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-10-18T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-10-18T14:19:53.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC8 saveParentControlInfo compare_parentcontrol_time stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-10123",
    "datePublished": "2024-10-18T19:31:05.643Z",
    "dateReserved": "2024-10-18T12:13:59.942Z",
    "dateUpdated": "2024-10-18T20:42:45.158Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-10130 (GCVE-0-2024-10130)

Vulnerability from cvelistv5 – Published: 2024-10-18 21:31 – Updated: 2024-10-21 17:50
VLAI
Title
Tenda AC8 SetSysAutoRebbotCfg formSetRebootTimer stack-based overflow
Summary
A vulnerability classified as critical was found in Tenda AC8 16.03.34.06. This vulnerability affects the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.280918 vdb-entrytechnical-description
https://vuldb.com/?ctiid.280918 signaturepermissions-required
https://vuldb.com/?submit.422141 third-party-advisory
https://github.com/JohenanLi/router_vuls/blob/mai… exploit
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda AC8 Affected: 16.03.34.06
Create a notification for this product.
tenda ac8_firmware Affected: 16.03.34.06
    cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*
Create a notification for this product.
Credits
minipython (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac8_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "16.03.34.06"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-10130",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-21T17:49:08.621948Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-21T17:50:18.674Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC8",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.34.06"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "minipython (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical was found in Tenda AC8 16.03.34.06. This vulnerability affects the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In Tenda AC8 16.03.34.06 wurde eine Schwachstelle entdeckt. Sie wurde als kritisch eingestuft. Dabei geht es um die Funktion formSetRebootTimer der Datei /goform/SetSysAutoRebbotCfg. Dank der Manipulation des Arguments rebootTime mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-18T21:31:06.724Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-280918 | Tenda AC8 SetSysAutoRebbotCfg formSetRebootTimer stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.280918"
        },
        {
          "name": "VDB-280918 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.280918"
        },
        {
          "name": "Submit #422141 | Tenda AC8v4 V16.03.34.06 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.422141"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/JohenanLi/router_vuls/blob/main/ac8v4/FUN_004a8838.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-10-18T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-10-18T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-10-18T15:59:18.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC8 SetSysAutoRebbotCfg formSetRebootTimer stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-10130",
    "datePublished": "2024-10-18T21:31:06.724Z",
    "dateReserved": "2024-10-18T13:54:15.157Z",
    "dateUpdated": "2024-10-21T17:50:18.674Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-10194 (GCVE-0-2024-10194)

Vulnerability from cvelistv5 – Published: 2024-10-20 08:00 – Updated: 2024-10-21 19:54
VLAI
Title
WAVLINK WN530H4/WN530HG4/WN572HG3 Front-End Authentication Page login.cgi Goto_chidx stack-based overflow
Summary
A vulnerability was found in WAVLINK WN530H4, WN530HG4 and WN572HG3 up to 20221028. It has been classified as critical. Affected is the function Goto_chidx of the file login.cgi of the component Front-End Authentication Page. The manipulation of the argument wlanUrl leads to stack-based buffer overflow. The attack can only be initiated within the local network. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.280968 vdb-entrytechnical-description
https://vuldb.com/?ctiid.280968 signaturepermissions-required
https://vuldb.com/?submit.422834 third-party-advisory
https://docs.google.com/document/d/1PodIMRe1f0Ql8… exploit
Impacted products
Vendor Product Version
WAVLINK WN530H4 Affected: 20221028
Create a notification for this product.
WAVLINK WN530HG4 Affected: 20221028
Create a notification for this product.
WAVLINK WN572HG3 Affected: 20221028
Create a notification for this product.
wavlink wn530h4 Affected: 20221028
    cpe:2.3:h:wavlink:wn530h4:-:*:*:*:*:*:*:*
Create a notification for this product.
wavlink wn530hg4 Affected: 20221028
    cpe:2.3:h:wavlink:wn530hg4:-:*:*:*:*:*:*:*
Create a notification for this product.
wavlink wn572hg3 Affected: 20221028
    cpe:2.3:h:wavlink:wn572hg3:-:*:*:*:*:*:*:*
Create a notification for this product.
Credits
Stellar Lab (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:wavlink:wn530h4:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "wn530h4",
            "vendor": "wavlink",
            "versions": [
              {
                "status": "affected",
                "version": "20221028"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:wavlink:wn530hg4:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "wn530hg4",
            "vendor": "wavlink",
            "versions": [
              {
                "status": "affected",
                "version": "20221028"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:wavlink:wn572hg3:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "wn572hg3",
            "vendor": "wavlink",
            "versions": [
              {
                "status": "affected",
                "version": "20221028"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-10194",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-21T19:52:45.602669Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-21T19:54:26.267Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "Front-End Authentication Page"
          ],
          "product": "WN530H4",
          "vendor": "WAVLINK",
          "versions": [
            {
              "status": "affected",
              "version": "20221028"
            }
          ]
        },
        {
          "modules": [
            "Front-End Authentication Page"
          ],
          "product": "WN530HG4",
          "vendor": "WAVLINK",
          "versions": [
            {
              "status": "affected",
              "version": "20221028"
            }
          ]
        },
        {
          "modules": [
            "Front-End Authentication Page"
          ],
          "product": "WN572HG3",
          "vendor": "WAVLINK",
          "versions": [
            {
              "status": "affected",
              "version": "20221028"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "Stellar Lab (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in WAVLINK WN530H4, WN530HG4 and WN572HG3 up to 20221028. It has been classified as critical. Affected is the function Goto_chidx of the file login.cgi of the component Front-End Authentication Page. The manipulation of the argument wlanUrl leads to stack-based buffer overflow. The attack can only be initiated within the local network. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Es wurde eine kritische Schwachstelle in WAVLINK WN530H4, WN530HG4 and WN572HG3 bis 20221028 ausgemacht. Dabei betrifft es die Funktion Goto_chidx der Datei login.cgi der Komponente Front-End Authentication Page. Mittels Manipulieren des Arguments wlanUrl mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei im lokalen Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 8.3,
            "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-20T08:00:06.181Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-280968 | WAVLINK WN530H4/WN530HG4/WN572HG3 Front-End Authentication Page login.cgi Goto_chidx stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.280968"
        },
        {
          "name": "VDB-280968 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.280968"
        },
        {
          "name": "Submit #422834 | wavlink WN530H4,WN530HG4,WN572HG3 WN530H4-WAVLINK_20220721,WN530HG4-WAVLINK_20220809,WN572HG3-WAVLINK_WO_20221028 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.422834"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://docs.google.com/document/d/1PodIMRe1f0Ql83jUXV5VIoc-Xsf9VC1K"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-10-19T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-10-19T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-10-19T09:41:16.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "WAVLINK WN530H4/WN530HG4/WN572HG3 Front-End Authentication Page login.cgi Goto_chidx stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-10194",
    "datePublished": "2024-10-20T08:00:06.181Z",
    "dateReserved": "2024-10-19T07:36:09.437Z",
    "dateUpdated": "2024-10-21T19:54:26.267Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-10238 (GCVE-0-2024-10238)

Vulnerability from cvelistv5 – Published: 2025-02-04 08:00 – Updated: 2025-02-04 14:33
VLAI
Title
fld->used_bytes without sanity check causes stack overflow
Summary
A security issue in the firmware image verification implementation at Supermicro MBD-X12DPG-OA6. An attacker can upload a specially crafted image that will cause a stack overflow is caused by not checking fld->used_bytes.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
Impacted products
Vendor Product Version
SMCI MBD-X12DPG-OA6 Affected: 1.04.16 (BMC)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-10238",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-04T14:33:06.944209Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-04T14:33:16.387Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "BMC"
          ],
          "product": "MBD-X12DPG-OA6",
          "vendor": "SMCI",
          "versions": [
            {
              "status": "affected",
              "version": "1.04.16",
              "versionType": "BMC"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA security issue in the firmware image verification implementation \n\n at Supermicro MBD-X12DPG-OA6. An attacker can upload a specially crafted image that will cause a stack overflow is caused by not checking fld-\u0026gt;used_bytes.\u003c/span\u003e"
            }
          ],
          "value": "A security issue in the firmware image verification implementation \n\n at Supermicro MBD-X12DPG-OA6. An attacker can upload a specially crafted image that will cause a stack overflow is caused by not checking fld-\u003eused_bytes."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-112",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-112: Overflow Buffers"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-04T08:00:51.373Z",
        "orgId": "def9a96e-e099-41a9-bfac-30fd4f82c411",
        "shortName": "Supermicro"
      },
      "references": [
        {
          "url": "https://www.supermicro.com/en/support/security_BMC_IPMI_Jan_2025"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "fld-\u003eused_bytes without sanity check causes stack overflow",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "def9a96e-e099-41a9-bfac-30fd4f82c411",
    "assignerShortName": "Supermicro",
    "cveId": "CVE-2024-10238",
    "datePublished": "2025-02-04T08:00:51.373Z",
    "dateReserved": "2024-10-22T03:14:23.997Z",
    "dateUpdated": "2025-02-04T14:33:16.387Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-10239 (GCVE-0-2024-10239)

Vulnerability from cvelistv5 – Published: 2025-02-04 08:02 – Updated: 2025-02-04 14:25
VLAI
Title
fld->used_bytes without sanity check causes stack overflow
Summary
A security issue in the firmware image verification implementation at Supermicro MBD-X12DPG-OA6 . An attacker with administrator privileges can upload a specially crafted image, which can cause a stack overflow due to the unchecked fat->fsd.max_fld.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
Impacted products
Vendor Product Version
SMCI MBD-X12DPG-OA6 Affected: 1.04.16 (BMC)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-10239",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-04T14:25:08.579433Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-04T14:25:28.872Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "platforms": [
            "BMC"
          ],
          "product": "MBD-X12DPG-OA6",
          "vendor": "SMCI",
          "versions": [
            {
              "status": "affected",
              "version": "1.04.16",
              "versionType": "BMC"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA security issue in the firmware image verification implementation at Supermicro\u0026nbsp;MBD-X12DPG-OA6\u0026nbsp;. An attacker with administrator privileges can upload a specially crafted image, which can cause a stack overflow due to the unchecked fat-\u0026gt;fsd.max_fld.\u003c/span\u003e"
            }
          ],
          "value": "A security issue in the firmware image verification implementation at Supermicro\u00a0MBD-X12DPG-OA6\u00a0. An attacker with administrator privileges can upload a specially crafted image, which can cause a stack overflow due to the unchecked fat-\u003efsd.max_fld."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-112",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-112: Overflow Buffers"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-04T08:02:02.414Z",
        "orgId": "def9a96e-e099-41a9-bfac-30fd4f82c411",
        "shortName": "Supermicro"
      },
      "references": [
        {
          "url": "https://www.supermicro.com/en/support/security_BMC_IPMI_Jan_2025"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "fld-\u003eused_bytes without sanity check causes stack overflow",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "def9a96e-e099-41a9-bfac-30fd4f82c411",
    "assignerShortName": "Supermicro",
    "cveId": "CVE-2024-10239",
    "datePublished": "2025-02-04T08:02:02.414Z",
    "dateReserved": "2024-10-22T03:14:25.875Z",
    "dateUpdated": "2025-02-04T14:25:28.872Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-10281 (GCVE-0-2024-10281)

Vulnerability from cvelistv5 – Published: 2024-10-23 14:00 – Updated: 2024-10-23 18:20
VLAI
Title
Tenda RX9/RX9 Pro SetStaticRouteCfg sub_42EEE0 stack-based overflow
Summary
A vulnerability classified as critical has been found in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20. Affected is the function sub_42EEE0 of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
SSVC
Exploitation: poc Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.281556 vdb-entrytechnical-description
https://vuldb.com/?ctiid.281556 signaturepermissions-required
https://vuldb.com/?submit.427065 third-party-advisory
https://gitee.com/GXB0_0/iot-vul/blob/master/Tend… exploit
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda RX9 Affected: 22.03.02.10
Affected: 22.03.02.20
Create a notification for this product.
Tenda RX9 Pro Affected: 22.03.02.10
Affected: 22.03.02.20
Create a notification for this product.
tenda rx9 Affected: 22.03.02.10
Affected: 22.03.02.20
    cpe:2.3:a:tenda:rx9:*:*:*:*:*:*:*:*
Create a notification for this product.
tenda rx9_pro Affected: 22.03.02.10
Affected: 22.03.02.20
    cpe:2.3:h:tenda:rx9_pro:-:*:*:*:*:*:*:*
Create a notification for this product.
Credits
GuoXB (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:tenda:rx9:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "rx9",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "22.03.02.10"
              },
              {
                "status": "affected",
                "version": "22.03.02.20"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:rx9_pro:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "rx9_pro",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "22.03.02.10"
              },
              {
                "status": "affected",
                "version": "22.03.02.20"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-10281",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-23T18:19:28.352564Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-23T18:20:52.773Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "RX9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "22.03.02.10"
            },
            {
              "status": "affected",
              "version": "22.03.02.20"
            }
          ]
        },
        {
          "product": "RX9 Pro",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "22.03.02.10"
            },
            {
              "status": "affected",
              "version": "22.03.02.20"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "GuoXB (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical has been found in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20. Affected is the function sub_42EEE0 of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Es wurde eine kritische Schwachstelle in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20 entdeckt. Hiervon betroffen ist die Funktion sub_42EEE0 der Datei /goform/SetStaticRouteCfg. Dank der Manipulation des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-23T14:00:24.603Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-281556 | Tenda RX9/RX9 Pro SetStaticRouteCfg sub_42EEE0 stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.281556"
        },
        {
          "name": "VDB-281556 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.281556"
        },
        {
          "name": "Submit #427065 | Tenda RX9 Router RX9 Pro Firmware V22.03.02.10\u3001RX9 Pro Firmware V22.03.02.20 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.427065"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://gitee.com/GXB0_0/iot-vul/blob/master/Tenda/RX9/20/SetStaticRouteCfg.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-10-23T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-10-23T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-10-23T08:12:43.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda RX9/RX9 Pro SetStaticRouteCfg sub_42EEE0 stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-10281",
    "datePublished": "2024-10-23T14:00:24.603Z",
    "dateReserved": "2024-10-23T06:07:35.435Z",
    "dateUpdated": "2024-10-23T18:20:52.773Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-10282 (GCVE-0-2024-10282)

Vulnerability from cvelistv5 – Published: 2024-10-23 14:31 – Updated: 2024-10-23 17:51
VLAI
Title
Tenda RX9/RX9 Pro SetVirtualServerCfg sub_42EA38 stack-based overflow
Summary
A vulnerability classified as critical was found in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20. Affected by this vulnerability is the function sub_42EA38 of the file /goform/SetVirtualServerCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
SSVC
Exploitation: poc Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.281557 vdb-entrytechnical-description
https://vuldb.com/?ctiid.281557 signaturepermissions-required
https://vuldb.com/?submit.427066 third-party-advisory
https://gitee.com/GXB0_0/iot-vul/blob/master/Tend… exploit
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda RX9 Affected: 22.03.02.10
Affected: 22.03.02.20
Create a notification for this product.
Tenda RX9 Pro Affected: 22.03.02.10
Affected: 22.03.02.20
Create a notification for this product.
tenda rx9 Affected: 22.03.02.10
Affected: 22.03.02.20
    cpe:2.3:a:tenda:rx9:*:*:*:*:*:*:*:*
Create a notification for this product.
tenda rx9_pro Affected: 22.03.02.10
Affected: 22.03.02.20
    cpe:2.3:h:tenda:rx9_pro:-:*:*:*:*:*:*:*
Create a notification for this product.
Credits
GuoXB (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:tenda:rx9:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "rx9",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "22.03.02.10"
              },
              {
                "status": "affected",
                "version": "22.03.02.20"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:tenda:rx9_pro:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "rx9_pro",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "22.03.02.10"
              },
              {
                "status": "affected",
                "version": "22.03.02.20"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-10282",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-23T17:50:18.481537Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-23T17:51:56.577Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "RX9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "22.03.02.10"
            },
            {
              "status": "affected",
              "version": "22.03.02.20"
            }
          ]
        },
        {
          "product": "RX9 Pro",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "22.03.02.10"
            },
            {
              "status": "affected",
              "version": "22.03.02.20"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "GuoXB (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical was found in Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20. Affected by this vulnerability is the function sub_42EA38 of the file /goform/SetVirtualServerCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "In Tenda RX9 and RX9 Pro 22.03.02.10/22.03.02.20 wurde eine kritische Schwachstelle entdeckt. Betroffen ist die Funktion sub_42EA38 der Datei /goform/SetVirtualServerCfg. Dank Manipulation des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-23T14:31:24.051Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-281557 | Tenda RX9/RX9 Pro SetVirtualServerCfg sub_42EA38 stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.281557"
        },
        {
          "name": "VDB-281557 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.281557"
        },
        {
          "name": "Submit #427066 | Tenda RX9 Router RX9 Pro Firmware V22.03.02.10\u3001RX9 Pro Firmware V22.03.02.20 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.427066"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://gitee.com/GXB0_0/iot-vul/blob/master/Tenda/RX9/20/SetVirtualServerCfg.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-10-23T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-10-23T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-10-23T08:12:46.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda RX9/RX9 Pro SetVirtualServerCfg sub_42EA38 stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-10282",
    "datePublished": "2024-10-23T14:31:24.051Z",
    "dateReserved": "2024-10-23T06:07:37.708Z",
    "dateUpdated": "2024-10-23T17:51:56.577Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-10283 (GCVE-0-2024-10283)

Vulnerability from cvelistv5 – Published: 2024-10-23 15:00 – Updated: 2024-10-23 17:33
VLAI
Title
Tenda RX9/RX9 Pro SetNetControlList sub_4337EC stack-based overflow
Summary
A vulnerability, which was classified as critical, has been found in Tenda RX9 and RX9 Pro 22.03.02.20. Affected by this issue is the function sub_4337EC of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
SSVC
Exploitation: poc Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.281558 vdb-entrytechnical-description
https://vuldb.com/?ctiid.281558 signaturepermissions-required
https://vuldb.com/?submit.427064 third-party-advisory
https://gitee.com/GXB0_0/iot-vul/blob/master/Tend… exploit
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda RX9 Affected: 22.03.02.20
Create a notification for this product.
Tenda RX9 Pro Affected: 22.03.02.20
Create a notification for this product.
tenda rx9_pro Affected: 22.03.02.20
    cpe:2.3:h:tenda:rx9_pro:-:*:*:*:*:*:*:*
Create a notification for this product.
tenda rx9 Affected: 22.03.02.20
    cpe:2.3:a:tenda:rx9:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
GuoXB (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:rx9_pro:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "rx9_pro",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "22.03.02.20"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:tenda:rx9:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "rx9",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "22.03.02.20"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-10283",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-23T17:30:46.351880Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-23T17:33:05.674Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "RX9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "22.03.02.20"
            }
          ]
        },
        {
          "product": "RX9 Pro",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "22.03.02.20"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "GuoXB (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, which was classified as critical, has been found in Tenda RX9 and RX9 Pro 22.03.02.20. Affected by this issue is the function sub_4337EC of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Eine kritische Schwachstelle wurde in Tenda RX9 and RX9 Pro 22.03.02.20 entdeckt. Betroffen davon ist die Funktion sub_4337EC der Datei /goform/SetNetControlList. Mit der Manipulation des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-23T15:00:12.454Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-281558 | Tenda RX9/RX9 Pro SetNetControlList sub_4337EC stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.281558"
        },
        {
          "name": "VDB-281558 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.281558"
        },
        {
          "name": "Submit #427064 | Tenda RX9 Router RX9 Pro Firmware V22.03.02.20 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.427064"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://gitee.com/GXB0_0/iot-vul/blob/master/Tenda/RX9/20/SetNetControlList.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-10-23T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-10-23T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-10-23T08:12:57.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda RX9/RX9 Pro SetNetControlList sub_4337EC stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-10283",
    "datePublished": "2024-10-23T15:00:12.454Z",
    "dateReserved": "2024-10-23T06:07:52.411Z",
    "dateUpdated": "2024-10-23T17:33:05.674Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-10351 (GCVE-0-2024-10351)

Vulnerability from cvelistv5 – Published: 2024-10-24 23:31 – Updated: 2024-10-25 20:50
VLAI
Title
Tenda RX9 Pro POST Request setMacFilterCfg sub_424CE0 stack-based overflow
Summary
A vulnerability was found in Tenda RX9 Pro 22.03.02.20. It has been rated as critical. This issue affects the function sub_424CE0 of the file /goform/setMacFilterCfg of the component POST Request Handler. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.281699 vdb-entrytechnical-description
https://vuldb.com/?ctiid.281699 signaturepermissions-required
https://vuldb.com/?submit.427706 third-party-advisory
https://gitee.com/GXB0_0/iot-vul/blob/master/Tend… exploit
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda RX9 Pro Affected: 22.03.02.20
Create a notification for this product.
tenda rx9_pro_firmware Affected: 22.03.02.20
    cpe:2.3:o:tenda:rx9_pro_firmware:22.03.02.20:*:*:*:*:*:*:*
Create a notification for this product.
Credits
GuoXB (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:rx9_pro_firmware:22.03.02.20:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "rx9_pro_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "22.03.02.20"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-10351",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-25T20:00:12.566902Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-25T20:50:14.294Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "POST Request Handler"
          ],
          "product": "RX9 Pro",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "22.03.02.20"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "GuoXB (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda RX9 Pro 22.03.02.20. It has been rated as critical. This issue affects the function sub_424CE0 of the file /goform/setMacFilterCfg of the component POST Request Handler. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda RX9 Pro 22.03.02.20 ausgemacht. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion sub_424CE0 der Datei /goform/setMacFilterCfg der Komponente POST Request Handler. Dank der Manipulation des Arguments deviceList mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-24T23:31:11.527Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-281699 | Tenda RX9 Pro POST Request setMacFilterCfg sub_424CE0 stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.281699"
        },
        {
          "name": "VDB-281699 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.281699"
        },
        {
          "name": "Submit #427706 | Tenda Rx9 Router RX9 Pro Firmware V22.03.02.20 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.427706"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://gitee.com/GXB0_0/iot-vul/blob/master/Tenda/RX9/20/setMacFilterCfg.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-10-24T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-10-24T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-10-24T17:39:44.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda RX9 Pro POST Request setMacFilterCfg sub_424CE0 stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-10351",
    "datePublished": "2024-10-24T23:31:11.527Z",
    "dateReserved": "2024-10-24T15:34:29.365Z",
    "dateUpdated": "2024-10-25T20:50:14.294Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-10434 (GCVE-0-2024-10434)

Vulnerability from cvelistv5 – Published: 2024-10-28 00:31 – Updated: 2024-10-28 13:00
VLAI
Title
Tenda AC1206 ate ate_Tenda_mfg_check_usb3 stack-based overflow
Summary
A vulnerability was found in Tenda AC1206 up to 20241027. It has been classified as critical. This affects the function ate_Tenda_mfg_check_usb/ate_Tenda_mfg_check_usb3 of the file /goform/ate. The manipulation of the argument arg leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.281985 vdb-entrytechnical-description
https://vuldb.com/?ctiid.281985 signaturepermissions-required
https://vuldb.com/?submit.431291 third-party-advisory
https://github.com/physicszq/Routers/blob/main/Te… exploit
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda AC1206 Affected: 20241027
Create a notification for this product.
tenda ac1206 Affected: 20241027
    cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*
Create a notification for this product.
Credits
physicszq (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac1206",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "20241027"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-10434",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-28T12:59:43.912430Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-28T13:00:50.500Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC1206",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "20241027"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "physicszq (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC1206 up to 20241027. It has been classified as critical. This affects the function ate_Tenda_mfg_check_usb/ate_Tenda_mfg_check_usb3 of the file /goform/ate. The manipulation of the argument arg leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Es wurde eine Schwachstelle in Tenda AC1206 bis 20241027 ausgemacht. Sie wurde als kritisch eingestuft. Es betrifft die Funktion ate_Tenda_mfg_check_usb/ate_Tenda_mfg_check_usb3 der Datei /goform/ate. Dank der Manipulation des Arguments arg mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-28T00:31:05.947Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-281985 | Tenda AC1206 ate ate_Tenda_mfg_check_usb3 stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.281985"
        },
        {
          "name": "VDB-281985 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.281985"
        },
        {
          "name": "Submit #431291 | tenda tenda router   AC1206 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.431291"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/physicszq/Routers/blob/main/Tenda/README.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-10-27T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-10-27T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-10-27T08:26:44.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC1206 ate ate_Tenda_mfg_check_usb3 stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-10434",
    "datePublished": "2024-10-28T00:31:05.947Z",
    "dateReserved": "2024-10-27T07:21:32.313Z",
    "dateUpdated": "2024-10-28T13:00:50.500Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation ID: MIT-10

Phases: Operation, Build and Compilation

Strategy: Environment Hardening

Description:

  • Use automatic buffer overflow detection mechanisms that are offered by certain compilers or compiler extensions. Examples include: the Microsoft Visual Studio /GS flag, Fedora/Red Hat FORTIFY_SOURCE GCC flag, StackGuard, and ProPolice, which provide various mechanisms including canary-based detection and range/index checking.
  • D3-SFCV (Stack Frame Canary Validation) from D3FEND [REF-1334] discusses canary-based detection in detail.
Mitigation

Phase: Architecture and Design

Description:

  • Use an abstraction library to abstract away risky APIs. Not a complete solution.
Mitigation

Phase: Implementation

Description:

  • Implement and perform bounds checking on input.
Mitigation

Phase: Implementation

Description:

  • Do not use dangerous functions such as gets. Use safer, equivalent functions which check for boundary errors.
Mitigation ID: MIT-11

Phases: Operation, Build and Compilation

Strategy: Environment Hardening

Description:

  • Run or compile the software using features or extensions that randomly arrange the positions of a program's executable and libraries in memory. Because this makes the addresses unpredictable, it can prevent an attacker from reliably jumping to exploitable code.
  • Examples include Address Space Layout Randomization (ASLR) [REF-58] [REF-60] and Position-Independent Executables (PIE) [REF-64]. Imported modules may be similarly realigned if their default memory addresses conflict with other modules, in a process known as "rebasing" (for Windows) and "prelinking" (for Linux) [REF-1332] using randomly generated addresses. ASLR for libraries cannot be used in conjunction with prelink since it would require relocating the libraries at run-time, defeating the whole purpose of prelinking.
  • For more information on these techniques see D3-SAOR (Segment Address Offset Randomization) from D3FEND [REF-1335].

No CAPEC attack patterns related to this CWE.

Back to CWE stats page