CWE-121

Stack-based Buffer Overflow

A stack-based buffer overflow condition is a condition where the buffer being overwritten is allocated on the stack (i.e., is a local variable or, rarely, a parameter to a function).

CVE-2024-10661 (GCVE-0-2024-10661)

Vulnerability from cvelistv5 – Published: 2024-11-01 16:00 – Updated: 2024-11-05 15:26
VLAI
Title
Tenda AC15 SetDlnaCfg stack-based overflow
Summary
A vulnerability has been found in Tenda AC15 15.03.05.19 and classified as critical. This vulnerability affects the function SetDlnaCfg of the file /goform/SetDlnaCfg. The manipulation of the argument scanList leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.282676 vdb-entrytechnical-description
https://vuldb.com/?ctiid.282676 signaturepermissions-required
https://vuldb.com/?submit.434932 third-party-advisory
https://github.com/theRaz0r/iot-mycve/blob/main/t… exploit
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda AC15 Affected: 15.03.05.19
Create a notification for this product.
tenda ac15_firmware Affected: 15.03.05.19
    cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*
Create a notification for this product.
Credits
theRaz0r (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac15_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.05.19"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-10661",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-01T19:06:43.033160Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-05T15:26:23.637Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC15",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.05.19"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "theRaz0r (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been found in Tenda AC15 15.03.05.19 and classified as critical. This vulnerability affects the function SetDlnaCfg of the file /goform/SetDlnaCfg. The manipulation of the argument scanList leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "In Tenda AC15 15.03.05.19 wurde eine kritische Schwachstelle gefunden. Das betrifft die Funktion SetDlnaCfg der Datei /goform/SetDlnaCfg. Durch das Beeinflussen des Arguments scanList mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-01T16:00:13.148Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-282676 | Tenda AC15 SetDlnaCfg stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.282676"
        },
        {
          "name": "VDB-282676 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.282676"
        },
        {
          "name": "Submit #434932 | Tenda AC15 V15.03.05.19 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.434932"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/theRaz0r/iot-mycve/blob/main/tenda_ac15_stackflow_formDLNAserver/tenda_ac15_stackflow_formDLNAserver.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-11-01T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-11-01T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-11-01T10:18:54.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC15 SetDlnaCfg stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-10661",
    "datePublished": "2024-11-01T16:00:13.148Z",
    "dateReserved": "2024-11-01T09:13:46.982Z",
    "dateUpdated": "2024-11-05T15:26:23.637Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-10662 (GCVE-0-2024-10662)

Vulnerability from cvelistv5 – Published: 2024-11-01 16:00 – Updated: 2024-11-05 15:25
VLAI
Title
Tenda AC15 SetOnlineDevName formSetDeviceName stack-based overflow
Summary
A vulnerability was found in Tenda AC15 15.03.05.19 and classified as critical. This issue affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.282677 vdb-entrytechnical-description
https://vuldb.com/?ctiid.282677 signaturepermissions-required
https://vuldb.com/?submit.434933 third-party-advisory
https://github.com/theRaz0r/iot-mycve/blob/main/t… exploit
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda AC15 Affected: 15.03.05.19
Create a notification for this product.
tenda ac15_firmware Affected: 15.03.05.19
    cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*
Create a notification for this product.
Credits
theRaz0r (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac15_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.05.19"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-10662",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-01T19:06:25.331828Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-05T15:25:38.625Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC15",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.05.19"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "theRaz0r (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC15 15.03.05.19 and classified as critical. This issue affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Eine kritische Schwachstelle wurde in Tenda AC15 15.03.05.19 gefunden. Dies betrifft die Funktion formSetDeviceName der Datei /goform/SetOnlineDevName. Durch Beeinflussen des Arguments devName mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-01T16:00:16.399Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-282677 | Tenda AC15 SetOnlineDevName formSetDeviceName stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.282677"
        },
        {
          "name": "VDB-282677 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.282677"
        },
        {
          "name": "Submit #434933 | Tenda AC15 V15.03.05.19 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.434933"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/theRaz0r/iot-mycve/blob/main/tenda_ac15_stackflow_formSetDeviceName/tenda_ac15_stackflow_formSetDeviceName.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-11-01T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-11-01T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-11-01T10:18:55.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC15 SetOnlineDevName formSetDeviceName stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-10662",
    "datePublished": "2024-11-01T16:00:16.399Z",
    "dateReserved": "2024-11-01T09:13:49.387Z",
    "dateUpdated": "2024-11-05T15:25:38.625Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-10698 (GCVE-0-2024-10698)

Vulnerability from cvelistv5 – Published: 2024-11-02 13:31 – Updated: 2024-11-05 15:20
VLAI
Title
Tenda AC6 SetOnlineDevName formSetDeviceName stack-based overflow
Summary
A vulnerability was found in Tenda AC6 15.03.05.19 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.282866 vdb-entrytechnical-description
https://vuldb.com/?ctiid.282866 signaturepermissions-required
https://vuldb.com/?submit.434935 third-party-advisory
https://github.com/theRaz0r/iot-mycve/blob/main/t… exploit
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda AC6 Affected: 15.03.05.19
Create a notification for this product.
tenda ac6_firmware Affected: 15.03.05.19
    cpe:2.3:o:tenda:ac6_firmware:15.03.05.19:*:*:*:*:*:*:*
Create a notification for this product.
Credits
theRaz0r (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac6_firmware:15.03.05.19:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac6_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.05.19"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-10698",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-05T15:20:09.420551Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-05T15:20:38.088Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC6",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.05.19"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "theRaz0r (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC6 15.03.05.19 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda AC6 15.03.05.19 gefunden. Sie wurde als kritisch eingestuft. Es geht hierbei um die Funktion formSetDeviceName der Datei /goform/SetOnlineDevName. Dank Manipulation des Arguments devName mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-02T13:31:07.358Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-282866 | Tenda AC6 SetOnlineDevName formSetDeviceName stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.282866"
        },
        {
          "name": "VDB-282866 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.282866"
        },
        {
          "name": "Submit #434935 | Tenda AC6 V15.03.05.19 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.434935"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/theRaz0r/iot-mycve/blob/main/tenda_ac6_stackflow_formSetDeviceName/tenda_ac6_stackflow_formSetDeviceName.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-11-01T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-11-01T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-11-01T18:06:51.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC6 SetOnlineDevName formSetDeviceName stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-10698",
    "datePublished": "2024-11-02T13:31:07.358Z",
    "dateReserved": "2024-11-01T17:01:44.965Z",
    "dateUpdated": "2024-11-05T15:20:38.088Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-10918 (GCVE-0-2024-10918)

Vulnerability from cvelistv5 – Published: 2025-02-27 11:44 – Updated: 2025-11-03 20:36
VLAI
Title
Stack-based Buffer Overflow in libmodbus library
Summary
Stack-based Buffer Overflow vulnerability in libmodbus v3.1.10 allows to overflow the buffer allocated for the Modbus response if the function tries to reply to a Modbus request with an unexpected length.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
Impacted products
Vendor Product Version
libmodbus libmodbus Affected: 0 , ≤ 3.1.10 (semver)
Create a notification for this product.
Credits
Gabriele Quagliarella of Nozomi Networks found this bug during a security research activity.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-10918",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-27T14:46:41.226453Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-27T14:46:51.404Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2025-11-03T20:36:25.510Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "https://lists.debian.org/debian-lts-announce/2025/03/msg00010.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "collectionURL": "https://libmodbus.org/",
          "defaultStatus": "unaffected",
          "modules": [
            "modbus"
          ],
          "product": "libmodbus",
          "programFiles": [
            "modbus.c"
          ],
          "programRoutines": [
            {
              "name": "modbus_reply"
            }
          ],
          "repo": "https://github.com/stephane/libmodbus",
          "vendor": "libmodbus",
          "versions": [
            {
              "lessThanOrEqual": "3.1.10",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Gabriele Quagliarella of Nozomi Networks found this bug during a security research activity."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Stack-based Buffer Overflow vulnerability in libmodbus v3.1.10 allows to overflow the buffer allocated for the Modbus response \u003cspan style=\"background-color: var(--wht);\"\u003eif the function tries to reply to a Modbus request with an\nunexpected length\u003c/span\u003e."
            }
          ],
          "value": "Stack-based Buffer Overflow vulnerability in libmodbus v3.1.10 allows to overflow the buffer allocated for the Modbus response if the function tries to reply to a Modbus request with an\nunexpected length."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-100",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-100 Overflow Buffers"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 4.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-27T11:44:25.170Z",
        "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "shortName": "Nozomi"
      },
      "references": [
        {
          "url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-10918"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "To fix this issue, it\u0027s suggested to update libmodbus to v3.1.11"
            }
          ],
          "value": "To fix this issue, it\u0027s suggested to update libmodbus to v3.1.11"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Stack-based Buffer Overflow in libmodbus library",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
    "assignerShortName": "Nozomi",
    "cveId": "CVE-2024-10918",
    "datePublished": "2025-02-27T11:44:25.170Z",
    "dateReserved": "2024-11-06T09:29:36.151Z",
    "dateUpdated": "2025-11-03T20:36:25.510Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2024-11047 (GCVE-0-2024-11047)

Vulnerability from cvelistv5 – Published: 2024-11-10 03:31 – Updated: 2024-11-12 15:46
VLAI
Title
D-Link DI-8003 upgrade_filter.asp upgrade_filter_asp stack-based overflow
Summary
A vulnerability was found in D-Link DI-8003 16.07.16A1. It has been declared as critical. Affected by this vulnerability is the function upgrade_filter_asp of the file /upgrade_filter.asp. The manipulation of the argument path leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
References
URL Tags
https://vuldb.com/?id.283633 vdb-entrytechnical-description
https://vuldb.com/?ctiid.283633 signaturepermissions-required
https://vuldb.com/?submit.434931 third-party-advisory
https://github.com/theRaz0r/iot-mycve/blob/main/D… exploit
https://www.dlink.com/ product
Impacted products
Vendor Product Version
D-Link DI-8003 Affected: 16.07.16A1
Create a notification for this product.
d-link di-8003_firmware Affected: 16.07.16a1
    cpe:2.3:o:d-link:di-8003_firmware:16.07.16a1:*:*:*:*:*:*:*
Create a notification for this product.
Credits
theRaz0r (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:d-link:di-8003_firmware:16.07.16a1:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "di-8003_firmware",
            "vendor": "d-link",
            "versions": [
              {
                "status": "affected",
                "version": "16.07.16a1"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-11047",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-12T15:44:21.435500Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-12T15:46:48.981Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "DI-8003",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "16.07.16A1"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "theRaz0r (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in D-Link DI-8003 16.07.16A1. It has been declared as critical. Affected by this vulnerability is the function upgrade_filter_asp of the file /upgrade_filter.asp. The manipulation of the argument path leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "In D-Link DI-8003 16.07.16A1 wurde eine kritische Schwachstelle ausgemacht. Dabei geht es um die Funktion upgrade_filter_asp der Datei /upgrade_filter.asp. Durch das Beeinflussen des Arguments path mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-10T03:31:04.900Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-283633 | D-Link DI-8003 upgrade_filter.asp upgrade_filter_asp stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.283633"
        },
        {
          "name": "VDB-283633 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.283633"
        },
        {
          "name": "Submit #434931 | Dlink DI8003 16.07.16A1 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.434931"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/theRaz0r/iot-mycve/blob/main/Dlink_DI8003_stackoverflow/Dlink_DI8003_stackoverflow.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.dlink.com/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-11-09T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-11-09T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-11-09T09:13:43.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "D-Link DI-8003 upgrade_filter.asp upgrade_filter_asp stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-11047",
    "datePublished": "2024-11-10T03:31:04.900Z",
    "dateReserved": "2024-11-09T08:08:34.041Z",
    "dateUpdated": "2024-11-12T15:46:48.981Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-11048 (GCVE-0-2024-11048)

Vulnerability from cvelistv5 – Published: 2024-11-10 04:00 – Updated: 2024-11-12 15:46
VLAI
Title
D-Link DI-8003 dbsrv.asp dbsrv_asp stack-based overflow
Summary
A vulnerability was found in D-Link DI-8003 16.07.16A1. It has been rated as critical. Affected by this issue is the function dbsrv_asp of the file /dbsrv.asp. The manipulation of the argument str leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
References
URL Tags
https://vuldb.com/?id.283634 vdb-entrytechnical-description
https://vuldb.com/?ctiid.283634 signaturepermissions-required
https://vuldb.com/?submit.434936 third-party-advisory
https://github.com/theRaz0r/iot-mycve/blob/main/D… exploit
https://www.dlink.com/ product
Impacted products
Vendor Product Version
D-Link DI-8003 Affected: 16.07.16A1
Create a notification for this product.
d-link di-8003_firmware Affected: 16.07.16a1
    cpe:2.3:o:d-link:di-8003_firmware:16.07.16a1:*:*:*:*:*:*:*
Create a notification for this product.
Credits
theRaz0r (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:d-link:di-8003_firmware:16.07.16a1:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "di-8003_firmware",
            "vendor": "d-link",
            "versions": [
              {
                "status": "affected",
                "version": "16.07.16a1"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-11048",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-12T15:44:15.502899Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-12T15:46:02.785Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "DI-8003",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "16.07.16A1"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "theRaz0r (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in D-Link DI-8003 16.07.16A1. It has been rated as critical. Affected by this issue is the function dbsrv_asp of the file /dbsrv.asp. The manipulation of the argument str leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Eine kritische Schwachstelle wurde in D-Link DI-8003 16.07.16A1 ausgemacht. Hierbei geht es um die Funktion dbsrv_asp der Datei /dbsrv.asp. Durch Beeinflussen des Arguments str mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-10T04:00:10.367Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-283634 | D-Link DI-8003 dbsrv.asp dbsrv_asp stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.283634"
        },
        {
          "name": "VDB-283634 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.283634"
        },
        {
          "name": "Submit #434936 | D-Link DI8003 16.07.16A1 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.434936"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/theRaz0r/iot-mycve/blob/main/Dlink_DI8003_stackoverflow/Dlink-DI8003-stackoverflow-dbsrv.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.dlink.com/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-11-09T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-11-09T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-11-09T09:13:45.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "D-Link DI-8003 dbsrv.asp dbsrv_asp stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-11048",
    "datePublished": "2024-11-10T04:00:10.367Z",
    "dateReserved": "2024-11-09T08:08:36.541Z",
    "dateUpdated": "2024-11-12T15:46:02.785Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-11056 (GCVE-0-2024-11056)

Vulnerability from cvelistv5 – Published: 2024-11-10 16:31 – Updated: 2024-11-12 20:11
VLAI
Title
Tenda AC10 WifiExtraSet FUN_0046AC38 stack-based overflow
Summary
A vulnerability, which was classified as critical, was found in Tenda AC10 16.03.10.13. Affected is the function FUN_0046AC38 of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
References
URL Tags
https://vuldb.com/?id.283800 vdb-entrytechnical-description
https://vuldb.com/?ctiid.283800 signaturepermissions-required
https://vuldb.com/?submit.439358 third-party-advisory
https://tasty-foxtrot-3a8.notion.site/Tenda-AC10v… exploit
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda AC10 Affected: 16.03.10.13
Create a notification for this product.
tenda ac10_firmware Affected: 16.03.10.13
    cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*
Create a notification for this product.
Credits
hand_king (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "16.03.10.13"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-11056",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-12T16:07:11.156602Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-12T20:11:15.388Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC10",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.10.13"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "hand_king (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, which was classified as critical, was found in Tenda AC10 16.03.10.13. Affected is the function FUN_0046AC38 of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Es wurde eine Schwachstelle in Tenda AC10 16.03.10.13 gefunden. Sie wurde als kritisch eingestuft. Es betrifft die Funktion FUN_0046AC38 der Datei /goform/WifiExtraSet. Dank der Manipulation des Arguments wpapsk_crypto mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-10T16:31:06.581Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-283800 | Tenda AC10 WifiExtraSet FUN_0046AC38 stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.283800"
        },
        {
          "name": "VDB-283800 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.283800"
        },
        {
          "name": "Submit #439358 | Tenda AC10v4 V16.03.10.13 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.439358"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://tasty-foxtrot-3a8.notion.site/Tenda-AC10v4-stack-overflow-1380448e619580409bb1e1ac85f45570"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-11-09T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-11-09T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-11-09T21:19:49.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC10 WifiExtraSet FUN_0046AC38 stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-11056",
    "datePublished": "2024-11-10T16:31:06.581Z",
    "dateReserved": "2024-11-09T20:14:34.790Z",
    "dateUpdated": "2024-11-12T20:11:15.388Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-11061 (GCVE-0-2024-11061)

Vulnerability from cvelistv5 – Published: 2024-11-11 00:31 – Updated: 2024-11-12 18:27
VLAI
Title
Tenda AC10 fast_setting_wifi_set FUN_0044db3c stack-based overflow
Summary
A vulnerability classified as critical was found in Tenda AC10 16.03.10.13. Affected by this vulnerability is the function FUN_0044db3c of the file /goform/fast_setting_wifi_set. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
References
URL Tags
https://vuldb.com/?id.283807 vdb-entrytechnical-description
https://vuldb.com/?ctiid.283807 signaturepermissions-required
https://vuldb.com/?submit.440825 third-party-advisory
https://tasty-foxtrot-3a8.notion.site/Tenda-AC10v… exploit
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda AC10 Affected: 16.03.10.13
Create a notification for this product.
tenda ac10_firmware Affected: 16.03.10.13
    cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*
Create a notification for this product.
Credits
hand_king (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "16.03.10.13"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-11061",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-12T16:17:31.059883Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-12T18:27:42.336Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC10",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.10.13"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "hand_king (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical was found in Tenda AC10 16.03.10.13. Affected by this vulnerability is the function FUN_0044db3c of the file /goform/fast_setting_wifi_set. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "In Tenda AC10 16.03.10.13 wurde eine kritische Schwachstelle entdeckt. Betroffen ist die Funktion FUN_0044db3c der Datei /goform/fast_setting_wifi_set. Durch das Manipulieren des Arguments timeZone mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-11T00:31:07.099Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-283807 | Tenda AC10 fast_setting_wifi_set FUN_0044db3c stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.283807"
        },
        {
          "name": "VDB-283807 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.283807"
        },
        {
          "name": "Submit #440825 | Tenda AC10v4 V16.03.10.13 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.440825"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://tasty-foxtrot-3a8.notion.site/Tenda-AC10v4-FUN_0044db3c-stack-overflow-13a0448e619580ae96fee2899545e159"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-11-10T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-11-10T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-11-10T09:50:30.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC10 fast_setting_wifi_set FUN_0044db3c stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-11061",
    "datePublished": "2024-11-11T00:31:07.099Z",
    "dateReserved": "2024-11-10T08:45:18.006Z",
    "dateUpdated": "2024-11-12T18:27:42.336Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-11237 (GCVE-0-2024-11237)

Vulnerability from cvelistv5 – Published: 2024-11-15 12:00 – Updated: 2024-11-15 20:42
VLAI
Title
TP-Link VN020 F3v(T) DHCP DISCOVER Packet Parser TP-Thumper stack-based overflow
Summary
A vulnerability, which was classified as critical, has been found in TP-Link VN020 F3v(T) TT_V6.2.1021. Affected by this issue is some unknown functionality of the component DHCP DISCOVER Packet Parser. The manipulation of the argument hostname leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
SSVC
Exploitation: poc Automatable: yes Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
Assigner
References
Impacted products
Vendor Product Version
TP-Link VN020 F3v(T) Affected: TT_V6.2.1021
Create a notification for this product.
tp-link vn020_f3v_firmware Affected: tt_v6.2.1021
    cpe:2.3:o:tp-link:vn020_f3v_firmware:tt_v6.2.1021:*:*:*:*:*:*:*
Create a notification for this product.
Credits
Mohamed Maatallah (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tp-link:vn020_f3v_firmware:tt_v6.2.1021:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "vn020_f3v_firmware",
            "vendor": "tp-link",
            "versions": [
              {
                "status": "affected",
                "version": "tt_v6.2.1021"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-11237",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-15T20:29:12.783100Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-15T20:42:20.206Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "DHCP DISCOVER Packet Parser"
          ],
          "product": "VN020 F3v(T)",
          "vendor": "TP-Link",
          "versions": [
            {
              "status": "affected",
              "version": "TT_V6.2.1021"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "Mohamed Maatallah (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, which was classified as critical, has been found in TP-Link VN020 F3v(T) TT_V6.2.1021. Affected by this issue is some unknown functionality of the component DHCP DISCOVER Packet Parser. The manipulation of the argument hostname leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Eine kritische Schwachstelle wurde in TP-Link VN020 F3v(T) TT_V6.2.1021 entdeckt. Dies betrifft einen unbekannten Teil der Komponente DHCP DISCOVER Packet Parser. Durch die Manipulation des Arguments hostname mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 7.8,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-15T12:00:15.886Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-284672 | TP-Link VN020 F3v(T) DHCP DISCOVER Packet Parser TP-Thumper stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.284672"
        },
        {
          "name": "VDB-284672 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.284672"
        },
        {
          "name": "Submit #438408 | TP-Link VN020 F3v(T) ISP Routers Hardware Version: 1.0 /  Firmware Version: TT_V6.2.1021 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.438408"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/Zephkek/TP-Thumper"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/Zephkek/TP-Thumper/blob/main/poc.c"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tp-link.com/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-11-15T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-11-15T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-11-15T08:09:30.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "TP-Link VN020 F3v(T) DHCP DISCOVER Packet Parser TP-Thumper stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-11237",
    "datePublished": "2024-11-15T12:00:15.886Z",
    "dateReserved": "2024-11-15T07:04:26.277Z",
    "dateUpdated": "2024-11-15T20:42:20.206Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-11248 (GCVE-0-2024-11248)

Vulnerability from cvelistv5 – Published: 2024-11-15 17:00 – Updated: 2024-11-15 19:30
VLAI
Title
Tenda AC10 SetSysAutoRebbotCfg formSetRebootTimer stack-based overflow
Summary
A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. Affected by this issue is the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
References
URL Tags
https://vuldb.com/?id.284684 vdb-entrytechnical-description
https://vuldb.com/?ctiid.284684 signaturepermissions-required
https://vuldb.com/?submit.443204 third-party-advisory
https://tasty-foxtrot-3a8.notion.site/Tenda-AC10v… exploit
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda AC10 Affected: 16.03.10.13
Create a notification for this product.
tenda ac10_firmware Affected: 16.03.10.13
    cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*
Create a notification for this product.
Credits
hand_king (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "16.03.10.13"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-11248",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-15T19:29:37.983327Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-15T19:30:31.322Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC10",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.10.13"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "hand_king (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. Affected by this issue is the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda AC10 16.03.10.13 gefunden. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion formSetRebootTimer der Datei /goform/SetSysAutoRebbotCfg. Durch Manipulation des Arguments rebootTime mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-15T17:00:12.864Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-284684 | Tenda AC10 SetSysAutoRebbotCfg formSetRebootTimer stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.284684"
        },
        {
          "name": "VDB-284684 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.284684"
        },
        {
          "name": "Submit #443204 | Tenda AC10v4 V16.03.10.13 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.443204"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://tasty-foxtrot-3a8.notion.site/Tenda-AC10v4-formSetRebootTimer-stack-overflow-13d0448e619580bf8ab1df7cfb6c018b"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-11-15T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-11-15T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-11-15T08:40:15.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC10 SetSysAutoRebbotCfg formSetRebootTimer stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-11248",
    "datePublished": "2024-11-15T17:00:12.864Z",
    "dateReserved": "2024-11-15T07:35:05.406Z",
    "dateUpdated": "2024-11-15T19:30:31.322Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation ID: MIT-10

Phases: Operation, Build and Compilation

Strategy: Environment Hardening

Description:

  • Use automatic buffer overflow detection mechanisms that are offered by certain compilers or compiler extensions. Examples include: the Microsoft Visual Studio /GS flag, Fedora/Red Hat FORTIFY_SOURCE GCC flag, StackGuard, and ProPolice, which provide various mechanisms including canary-based detection and range/index checking.
  • D3-SFCV (Stack Frame Canary Validation) from D3FEND [REF-1334] discusses canary-based detection in detail.
Mitigation

Phase: Architecture and Design

Description:

  • Use an abstraction library to abstract away risky APIs. Not a complete solution.
Mitigation

Phase: Implementation

Description:

  • Implement and perform bounds checking on input.
Mitigation

Phase: Implementation

Description:

  • Do not use dangerous functions such as gets. Use safer, equivalent functions which check for boundary errors.
Mitigation ID: MIT-11

Phases: Operation, Build and Compilation

Strategy: Environment Hardening

Description:

  • Run or compile the software using features or extensions that randomly arrange the positions of a program's executable and libraries in memory. Because this makes the addresses unpredictable, it can prevent an attacker from reliably jumping to exploitable code.
  • Examples include Address Space Layout Randomization (ASLR) [REF-58] [REF-60] and Position-Independent Executables (PIE) [REF-64]. Imported modules may be similarly realigned if their default memory addresses conflict with other modules, in a process known as "rebasing" (for Windows) and "prelinking" (for Linux) [REF-1332] using randomly generated addresses. ASLR for libraries cannot be used in conjunction with prelink since it would require relocating the libraries at run-time, defeating the whole purpose of prelinking.
  • For more information on these techniques see D3-SAOR (Segment Address Offset Randomization) from D3FEND [REF-1335].

No CAPEC attack patterns related to this CWE.

Back to CWE stats page