CWE-121

Stack-based Buffer Overflow

A stack-based buffer overflow condition is a condition where the buffer being overwritten is allocated on the stack (i.e., is a local variable or, rarely, a parameter to a function).

CVE-2024-2813 (GCVE-0-2024-2813)

Vulnerability from cvelistv5 – Published: 2024-03-22 06:31 – Updated: 2024-08-23 20:28
VLAI
Title
Tenda AC15 fast_setting_wifi_set form_fast_setting_wifi_set stack-based overflow
Summary
A vulnerability was found in Tenda AC15 15.03.20_multi. It has been declared as critical. This vulnerability affects the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257668. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.257668 vdb-entrytechnical-description
https://vuldb.com/?ctiid.257668 signaturepermissions-required
https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
Impacted products
Vendor Product Version
Tenda AC15 Affected: 15.03.20_multi
Create a notification for this product.
tenda ac15_firmware Affected: 15.03.05.20_multi
    cpe:2.3:o:tenda:ac15_firmware:15.03.05.20_multi:*:*:*:*:*:*:*
Create a notification for this product.
Credits
yhryhryhr_miemie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac15_firmware:15.03.05.20_multi:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac15_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.05.20_multi"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2813",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-23T20:28:00.506212Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-23T20:28:09.491Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:25:41.881Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-257668 | Tenda AC15 fast_setting_wifi_set form_fast_setting_wifi_set stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.257668"
          },
          {
            "name": "VDB-257668 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.257668"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/form_fast_setting_wifi_set.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC15",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.20_multi"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr_miemie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC15 15.03.20_multi. It has been declared as critical. This vulnerability affects the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257668. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In Tenda AC15 15.03.20_multi wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Dabei geht es um die Funktion form_fast_setting_wifi_set der Datei /goform/fast_setting_wifi_set. Durch Manipulation des Arguments ssid mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-22T06:31:05.875Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-257668 | Tenda AC15 fast_setting_wifi_set form_fast_setting_wifi_set stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.257668"
        },
        {
          "name": "VDB-257668 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.257668"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/form_fast_setting_wifi_set.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-21T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-21T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-21T22:40:06.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC15 fast_setting_wifi_set form_fast_setting_wifi_set stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2813",
    "datePublished": "2024-03-22T06:31:05.875Z",
    "dateReserved": "2024-03-21T21:35:03.729Z",
    "dateUpdated": "2024-08-23T20:28:09.491Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-2814 (GCVE-0-2024-2814)

Vulnerability from cvelistv5 – Published: 2024-03-22 07:00 – Updated: 2024-08-08 20:34
VLAI
Title
Tenda AC15 DhcpListClient fromDhcpListClient stack-based overflow
Summary
A vulnerability was found in Tenda AC15 15.03.20_multi. It has been rated as critical. This issue affects the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257669 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.257669 vdb-entrytechnical-description
https://vuldb.com/?ctiid.257669 signaturepermissions-required
https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
Impacted products
Vendor Product Version
Tenda AC15 Affected: 15.03.20_multi
Create a notification for this product.
tenda ac15_firmware Affected: 15.03.05.20_multi
    cpe:2.3:o:tenda:ac15_firmware:15.03.05.20_multi:*:*:*:*:*:*:*
Create a notification for this product.
Credits
yhryhryhr_miemie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:25:42.195Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-257669 | Tenda AC15 DhcpListClient fromDhcpListClient stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.257669"
          },
          {
            "name": "VDB-257669 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.257669"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/fromDhcpListClient_page.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac15_firmware:15.03.05.20_multi:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac15_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.05.20_multi"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2814",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-08T20:33:21.558548Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-08T20:34:16.925Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC15",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.20_multi"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr_miemie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC15 15.03.20_multi. It has been rated as critical. This issue affects the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257669 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda AC15 15.03.20_multi ausgemacht. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion fromDhcpListClient der Datei /goform/DhcpListClient. Mittels dem Manipulieren des Arguments page mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-22T07:00:07.402Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-257669 | Tenda AC15 DhcpListClient fromDhcpListClient stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.257669"
        },
        {
          "name": "VDB-257669 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.257669"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/fromDhcpListClient_page.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-21T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-21T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-21T22:40:11.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC15 DhcpListClient fromDhcpListClient stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2814",
    "datePublished": "2024-03-22T07:00:07.402Z",
    "dateReserved": "2024-03-21T21:35:08.751Z",
    "dateUpdated": "2024-08-08T20:34:16.925Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-2815 (GCVE-0-2024-2815)

Vulnerability from cvelistv5 – Published: 2024-03-22 07:31 – Updated: 2024-08-01 19:25
VLAI
Title
Tenda AC15 Cookie execCommand R7WebsSecurityHandler stack-based overflow
Summary
A vulnerability classified as critical has been found in Tenda AC15 15.03.20_multi. Affected is the function R7WebsSecurityHandler of the file /goform/execCommand of the component Cookie Handler. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257670 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.257670 vdb-entrytechnical-description
https://vuldb.com/?ctiid.257670 signaturepermissions-required
https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
Impacted products
Vendor Product Version
Tenda AC15 Affected: 15.03.20_multi
Create a notification for this product.
tenda ac15_firmware Affected: 15.03.20_multi
    cpe:2.3:o:tenda:ac15_firmware:15.03.20_multi:*:*:*:*:*:*:*
Create a notification for this product.
Credits
yhryhryhr_tutu (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac15_firmware:15.03.20_multi:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac15_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.20_multi"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2815",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-08T13:57:42.883520Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-08T19:51:33.522Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:25:42.123Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-257670 | Tenda AC15 Cookie execCommand R7WebsSecurityHandler stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.257670"
          },
          {
            "name": "VDB-257670 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.257670"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/R7WebsSecurityHandler.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "Cookie Handler"
          ],
          "product": "AC15",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.20_multi"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr_tutu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical has been found in Tenda AC15 15.03.20_multi. Affected is the function R7WebsSecurityHandler of the file /goform/execCommand of the component Cookie Handler. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257670 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Es wurde eine kritische Schwachstelle in Tenda AC15 15.03.20_multi entdeckt. Es betrifft die Funktion R7WebsSecurityHandler der Datei /goform/execCommand der Komponente Cookie Handler. Mittels Manipulieren des Arguments password mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-22T07:31:04.644Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-257670 | Tenda AC15 Cookie execCommand R7WebsSecurityHandler stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.257670"
        },
        {
          "name": "VDB-257670 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.257670"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/R7WebsSecurityHandler.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-21T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-21T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-21T22:40:16.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC15 Cookie execCommand R7WebsSecurityHandler stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2815",
    "datePublished": "2024-03-22T07:31:04.644Z",
    "dateReserved": "2024-03-21T21:35:13.502Z",
    "dateUpdated": "2024-08-01T19:25:42.123Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-2850 (GCVE-0-2024-2850)

Vulnerability from cvelistv5 – Published: 2024-03-24 02:00 – Updated: 2024-08-01 19:25
VLAI
Title
Tenda AC15 saveParentControlInfo stack-based overflow
Summary
A vulnerability was found in Tenda AC15 15.03.05.18 and classified as critical. Affected by this issue is the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257774 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.257774 vdb-entrytechnical-description
https://vuldb.com/?ctiid.257774 signaturepermissions-required
https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
Impacted products
Vendor Product Version
Tenda AC15 Affected: 15.03.05.18
Create a notification for this product.
tenda ac15_firmware Affected: 15.03.05.18
    cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*
Create a notification for this product.
Credits
wxhwxhwxh_miemie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac15_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.05.18"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2850",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-08T13:55:57.303430Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-08T19:51:25.514Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:25:42.127Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-257774 | Tenda AC15 saveParentControlInfo stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.257774"
          },
          {
            "name": "VDB-257774 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.257774"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/saveParentControlInfo_urls.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC15",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.05.18"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_miemie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC15 15.03.05.18 and classified as critical. Affected by this issue is the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257774 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda AC15 15.03.05.18 gefunden. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion saveParentControlInfo der Datei /goform/saveParentControlInfo. Dank der Manipulation des Arguments urls mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-24T02:00:06.578Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-257774 | Tenda AC15 saveParentControlInfo stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.257774"
        },
        {
          "name": "VDB-257774 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.257774"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V15.03.05.18/saveParentControlInfo_urls.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-23T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-23T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-23T06:51:53.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC15 saveParentControlInfo stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2850",
    "datePublished": "2024-03-24T02:00:06.578Z",
    "dateReserved": "2024-03-23T05:46:47.272Z",
    "dateUpdated": "2024-08-01T19:25:42.127Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-2852 (GCVE-0-2024-2852)

Vulnerability from cvelistv5 – Published: 2024-03-24 04:31 – Updated: 2024-08-01 19:25
VLAI
Title
Tenda AC15 saveParentControlInfo stack-based overflow
Summary
A vulnerability was found in Tenda AC15 15.03.20_multi. It has been declared as critical. This vulnerability affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257776. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.257776 vdb-entrytechnical-description
https://vuldb.com/?ctiid.257776 signaturepermissions-required
https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
Impacted products
Vendor Product Version
Tenda AC15 Affected: 15.03.20_multi
Create a notification for this product.
Credits
wxhwxhwxh_miemie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2852",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-25T16:30:34.040979Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-05T17:21:17.156Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:25:42.173Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-257776 | Tenda AC15 saveParentControlInfo stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.257776"
          },
          {
            "name": "VDB-257776 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.257776"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/saveParentControlInfo_urls.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC15",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.20_multi"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_miemie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC15 15.03.20_multi. It has been declared as critical. This vulnerability affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257776. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In Tenda AC15 15.03.20_multi wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Das betrifft die Funktion saveParentControlInfo der Datei /goform/saveParentControlInfo. Mit der Manipulation des Arguments urls mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-24T04:31:04.363Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-257776 | Tenda AC15 saveParentControlInfo stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.257776"
        },
        {
          "name": "VDB-257776 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.257776"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/saveParentControlInfo_urls.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-23T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-23T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-23T06:52:11.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC15 saveParentControlInfo stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2852",
    "datePublished": "2024-03-24T04:31:04.363Z",
    "dateReserved": "2024-03-23T05:46:57.422Z",
    "dateUpdated": "2024-08-01T19:25:42.173Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-2855 (GCVE-0-2024-2855)

Vulnerability from cvelistv5 – Published: 2024-03-24 06:00 – Updated: 2024-08-01 19:25
VLAI
Title
Tenda AC15 SetSysTimeCfg fromSetSysTime stack-based overflow
Summary
A vulnerability classified as critical was found in Tenda AC15 15.03.05.18/15.03.05.19/15.03.20. Affected by this vulnerability is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257779. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.257779 vdb-entrytechnical-description
https://vuldb.com/?ctiid.257779 signaturepermissions-required
https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
Impacted products
Vendor Product Version
Tenda AC15 Affected: 15.03.05.18
Affected: 15.03.05.19
Affected: 15.03.20
Create a notification for this product.
tenda ac15_firmware Affected: 15.03.05.18
    cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*
Create a notification for this product.
tenda ac15_firmware Affected: 15.03.05.19
    cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*
Create a notification for this product.
tenda ac15_firmware Affected: 15.03.20_multi
    cpe:2.3:o:tenda:ac15_firmware:15.03.20_multi:*:*:*:*:*:*:*
Create a notification for this product.
Credits
wxhwxhwxh_miemie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac15_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.05.18"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac15_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.05.19"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac15_firmware:15.03.20_multi:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac15_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.20_multi"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2855",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-08T13:38:53.645813Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-08T19:51:14.751Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:25:42.153Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-257779 | Tenda AC15 SetSysTimeCfg fromSetSysTime stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.257779"
          },
          {
            "name": "VDB-257779 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.257779"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/fromSetSysTime.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC15",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.05.18"
            },
            {
              "status": "affected",
              "version": "15.03.05.19"
            },
            {
              "status": "affected",
              "version": "15.03.20"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_miemie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical was found in Tenda AC15 15.03.05.18/15.03.05.19/15.03.20. Affected by this vulnerability is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257779. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In Tenda AC15 15.03.05.18/15.03.05.19/15.03.20 wurde eine kritische Schwachstelle entdeckt. Hierbei betrifft es die Funktion fromSetSysTime der Datei /goform/SetSysTimeCfg. Mittels dem Manipulieren des Arguments time mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-24T06:00:06.171Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-257779 | Tenda AC15 SetSysTimeCfg fromSetSysTime stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.257779"
        },
        {
          "name": "VDB-257779 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.257779"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/fromSetSysTime.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-23T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-23T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-23T06:52:35.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC15 SetSysTimeCfg fromSetSysTime stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2855",
    "datePublished": "2024-03-24T06:00:06.171Z",
    "dateReserved": "2024-03-23T05:47:33.356Z",
    "dateUpdated": "2024-08-01T19:25:42.153Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-2856 (GCVE-0-2024-2856)

Vulnerability from cvelistv5 – Published: 2024-03-24 06:31 – Updated: 2024-08-21 15:03
VLAI
Title
Tenda AC10 SetSysTimeCfg fromSetSysTime stack-based overflow
Summary
A vulnerability, which was classified as critical, has been found in Tenda AC10 16.03.10.13/16.03.10.20. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257780. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.257780 vdb-entrytechnical-description
https://vuldb.com/?ctiid.257780 signaturepermissions-required
https://vuldb.com/?submit.299741 third-party-advisory
https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
Impacted products
Vendor Product Version
Tenda AC10 Affected: 16.03.10.13
Affected: 16.03.10.20
Create a notification for this product.
tenda ac10_firmware Affected: 16.03.10.13
    cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*
Create a notification for this product.
tenda ac10_firmware Affected: 16.03.10.20
    cpe:2.3:o:tenda:ac10_firmware:16.03.10.20:*:*:*:*:*:*:*
Create a notification for this product.
Credits
wxhwxhwxh_miemie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:25:42.134Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-257780 | Tenda AC10 SetSysTimeCfg fromSetSysTime stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.257780"
          },
          {
            "name": "VDB-257780 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.257780"
          },
          {
            "name": "Submit #299741 | Tenda AC10 AC10 v4.0 V16.03.10.13\u3001V16.03.10.20 buffer overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.299741"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10/V16.03.10.13/fromSetSysTime.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "16.03.10.13"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac10_firmware:16.03.10.20:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac10_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "16.03.10.20"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2856",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-21T15:00:54.641317Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-21T15:03:56.980Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC10",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.10.13"
            },
            {
              "status": "affected",
              "version": "16.03.10.20"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_miemie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, which was classified as critical, has been found in Tenda AC10 16.03.10.13/16.03.10.20. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257780. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine kritische Schwachstelle wurde in Tenda AC10 16.03.10.13/16.03.10.20 entdeckt. Davon betroffen ist die Funktion fromSetSysTime der Datei /goform/SetSysTimeCfg. Mittels Manipulieren des Arguments timeZone mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-25T12:14:28.193Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-257780 | Tenda AC10 SetSysTimeCfg fromSetSysTime stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.257780"
        },
        {
          "name": "VDB-257780 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.257780"
        },
        {
          "name": "Submit #299741 | Tenda AC10 AC10 v4.0 V16.03.10.13\u3001V16.03.10.20 buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.299741"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC10/V16.03.10.13/fromSetSysTime.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-23T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-23T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-23T06:52:42.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC10 SetSysTimeCfg fromSetSysTime stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2856",
    "datePublished": "2024-03-24T06:31:04.241Z",
    "dateReserved": "2024-03-23T05:47:39.796Z",
    "dateUpdated": "2024-08-21T15:03:56.980Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-28877 (GCVE-0-2024-28877)

Vulnerability from cvelistv5 – Published: 2024-06-11 20:15 – Updated: 2024-08-02 00:56
VLAI
Title
MicroDicom DICOM Viewer Stack-based Buffer Overflow
Summary
MicroDicom DICOM Viewer is vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code on affected installations of DICOM Viewer. User interaction is required to exploit this vulnerability.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
Impacted products
Vendor Product Version
MicroDicom DICOM Viewer Affected: 0 , < 2024.2 (custom)
Create a notification for this product.
microdicom dicom_viewer Affected: 0 , < 2024.2 (custom)
    cpe:2.3:a:microdicom:dicom_viewer:*:*:*:*:*:*:*:*
Create a notification for this product.
Date Public
2024-06-11 17:00
Credits
Michael Heinzl reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:microdicom:dicom_viewer:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "dicom_viewer",
            "vendor": "microdicom",
            "versions": [
              {
                "lessThan": "2024.2",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-28877",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-12T13:31:33.687104Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-12T13:32:03.847Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T00:56:58.121Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-163-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "DICOM Viewer",
          "vendor": "MicroDicom",
          "versions": [
            {
              "lessThan": "2024.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Michael Heinzl reported these vulnerabilities to CISA."
        }
      ],
      "datePublic": "2024-06-11T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eMicroDicom DICOM Viewer is vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code on affected installations of DICOM Viewer. User interaction is required to exploit this vulnerability.\u003c/span\u003e\n\n\u003c/span\u003e"
            }
          ],
          "value": "MicroDicom DICOM Viewer is vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code on affected installations of DICOM Viewer. User interaction is required to exploit this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121  Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-11T20:19:09.546Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-163-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eMicroDicom recommends users upgrade to DICOM Viewer version \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.microdicom.com/downloads.html\"\u003e2024.2\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e.\u003c/span\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "MicroDicom recommends users upgrade to DICOM Viewer version  2024.2 https://www.microdicom.com/downloads.html ."
        }
      ],
      "source": {
        "advisory": "ICSMA-24-163-01",
        "discovery": "EXTERNAL"
      },
      "title": "MicroDicom DICOM Viewer Stack-based Buffer Overflow",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2024-28877",
    "datePublished": "2024-06-11T20:15:14.566Z",
    "dateReserved": "2024-05-23T16:46:23.930Z",
    "dateUpdated": "2024-08-02T00:56:58.121Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-28898 (GCVE-0-2024-28898)

Vulnerability from cvelistv5 – Published: 2024-04-09 17:00 – Updated: 2025-05-03 00:39
VLAI
Title
Secure Boot Security Feature Bypass Vulnerability
Summary
Secure Boot Security Feature Bypass Vulnerability
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Microsoft Windows 10 Version 1809 Affected: 10.0.17763.0 , < 10.0.17763.5696 (custom)
Create a notification for this product.
Microsoft Windows 10 Version 1809 Affected: 10.0.0 , < 10.0.17763.5696 (custom)
Create a notification for this product.
Microsoft Windows Server 2019 Affected: 10.0.17763.0 , < 10.0.17763.5696 (custom)
Create a notification for this product.
Microsoft Windows Server 2019 (Server Core installation) Affected: 10.0.17763.0 , < 10.0.17763.5696 (custom)
Create a notification for this product.
Microsoft Windows Server 2022 Affected: 10.0.20348.0 , < 10.0.20348.2402 (custom)
Create a notification for this product.
Microsoft Windows 11 version 21H2 Affected: 10.0.0 , < 10.0.22000.2899 (custom)
Create a notification for this product.
Microsoft Windows 10 Version 21H2 Affected: 10.0.19043.0 , < 10.0.19044.4291 (custom)
Create a notification for this product.
Microsoft Windows 11 version 22H2 Affected: 10.0.22621.0 , < 10.0.22621.3447 (custom)
Create a notification for this product.
Microsoft Windows 10 Version 22H2 Affected: 10.0.19045.0 , < 10.0.19045.4291 (custom)
Create a notification for this product.
Microsoft Windows 11 version 22H3 Affected: 10.0.22631.0 , < 10.0.22631.3447 (custom)
Create a notification for this product.
Microsoft Windows 11 Version 23H2 Affected: 10.0.22631.0 , < 10.0.22631.3447 (custom)
Create a notification for this product.
Microsoft Windows Server 2022, 23H2 Edition (Server Core installation) Affected: 10.0.25398.0 , < 10.0.25398.830 (custom)
Create a notification for this product.
Microsoft Windows 10 Version 1507 Affected: 10.0.10240.0 , < 10.0.10240.20596 (custom)
Create a notification for this product.
Microsoft Windows 10 Version 1607 Affected: 10.0.14393.0 , < 10.0.14393.6897 (custom)
Create a notification for this product.
Microsoft Windows Server 2016 Affected: 10.0.14393.0 , < 10.0.14393.6897 (custom)
Create a notification for this product.
Microsoft Windows Server 2016 (Server Core installation) Affected: 10.0.14393.0 , < 10.0.14393.6897 (custom)
Create a notification for this product.
Microsoft Windows Server 2012 Affected: 6.2.9200.0 , < 6.2.9200.24821 (custom)
Create a notification for this product.
Microsoft Windows Server 2012 (Server Core installation) Affected: 6.2.9200.0 , < 6.2.9200.24821 (custom)
Create a notification for this product.
Microsoft Windows Server 2012 R2 Affected: 6.3.9600.0 , < 6.3.9600.21924 (custom)
Create a notification for this product.
Microsoft Windows Server 2012 R2 (Server Core installation) Affected: 6.3.9600.0 , < 6.3.9600.21924 (custom)
Create a notification for this product.
Date Public
2024-04-09 07:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-28898",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-14T18:06:41.396540Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T18:03:07.711Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:03:50.243Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "Secure Boot Security Feature Bypass Vulnerability",
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://msrc.microsoft.com/update-guide/vulnerability/CVE-2024-28898"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "platforms": [
            "32-bit Systems",
            "x64-based Systems"
          ],
          "product": "Windows 10 Version 1809",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.17763.5696",
              "status": "affected",
              "version": "10.0.17763.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "ARM64-based Systems"
          ],
          "product": "Windows 10 Version 1809",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.17763.5696",
              "status": "affected",
              "version": "10.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2019",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.17763.5696",
              "status": "affected",
              "version": "10.0.17763.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2019 (Server Core installation)",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.17763.5696",
              "status": "affected",
              "version": "10.0.17763.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2022",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.20348.2402",
              "status": "affected",
              "version": "10.0.20348.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems",
            "ARM64-based Systems"
          ],
          "product": "Windows 11 version 21H2",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.22000.2899",
              "status": "affected",
              "version": "10.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "32-bit Systems",
            "ARM64-based Systems",
            "x64-based Systems"
          ],
          "product": "Windows 10 Version 21H2",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.19044.4291",
              "status": "affected",
              "version": "10.0.19043.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "ARM64-based Systems",
            "x64-based Systems"
          ],
          "product": "Windows 11 version 22H2",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.22621.3447",
              "status": "affected",
              "version": "10.0.22621.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems",
            "ARM64-based Systems",
            "32-bit Systems"
          ],
          "product": "Windows 10 Version 22H2",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.19045.4291",
              "status": "affected",
              "version": "10.0.19045.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "ARM64-based Systems"
          ],
          "product": "Windows 11 version 22H3",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.22631.3447",
              "status": "affected",
              "version": "10.0.22631.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows 11 Version 23H2",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.22631.3447",
              "status": "affected",
              "version": "10.0.22631.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2022, 23H2 Edition (Server Core installation)",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.25398.830",
              "status": "affected",
              "version": "10.0.25398.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "32-bit Systems",
            "x64-based Systems"
          ],
          "product": "Windows 10 Version 1507",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.10240.20596",
              "status": "affected",
              "version": "10.0.10240.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "32-bit Systems",
            "x64-based Systems"
          ],
          "product": "Windows 10 Version 1607",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.14393.6897",
              "status": "affected",
              "version": "10.0.14393.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2016",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.14393.6897",
              "status": "affected",
              "version": "10.0.14393.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2016 (Server Core installation)",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.14393.6897",
              "status": "affected",
              "version": "10.0.14393.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2012",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "6.2.9200.24821",
              "status": "affected",
              "version": "6.2.9200.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2012 (Server Core installation)",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "6.2.9200.24821",
              "status": "affected",
              "version": "6.2.9200.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2012 R2",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "6.3.9600.21924",
              "status": "affected",
              "version": "6.3.9600.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2012 R2 (Server Core installation)",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "6.3.9600.21924",
              "status": "affected",
              "version": "6.3.9600.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_10_1809:*:*:*:*:*:*:x86:*",
                  "versionEndExcluding": "10.0.17763.5696",
                  "versionStartIncluding": "10.0.17763.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_10_1809:*:*:*:*:*:*:arm64:*",
                  "versionEndExcluding": "10.0.17763.5696",
                  "versionStartIncluding": "10.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2019:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.17763.5696",
                  "versionStartIncluding": "10.0.17763.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2019:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.17763.5696",
                  "versionStartIncluding": "10.0.17763.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2022:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.20348.2402",
                  "versionStartIncluding": "10.0.20348.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_11_21H2:*:*:*:*:*:*:x64:*",
                  "versionEndExcluding": "10.0.22000.2899",
                  "versionStartIncluding": "10.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_10_21H2:*:*:*:*:*:*:x86:*",
                  "versionEndExcluding": "10.0.19044.4291",
                  "versionStartIncluding": "10.0.19043.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_11_22H2:*:*:*:*:*:*:arm64:*",
                  "versionEndExcluding": "10.0.22621.3447",
                  "versionStartIncluding": "10.0.22621.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_10_22H2:*:*:*:*:*:*:x64:*",
                  "versionEndExcluding": "10.0.19045.4291",
                  "versionStartIncluding": "10.0.19045.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_11_23H2:*:*:*:*:*:*:arm64:*",
                  "versionEndExcluding": "10.0.22631.3447",
                  "versionStartIncluding": "10.0.22631.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_11_23H2:*:*:*:*:*:*:x64:*",
                  "versionEndExcluding": "10.0.22631.3447",
                  "versionStartIncluding": "10.0.22631.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_23h2:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.25398.830",
                  "versionStartIncluding": "10.0.25398.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_10_1507:*:*:*:*:*:*:x86:*",
                  "versionEndExcluding": "10.0.10240.20596",
                  "versionStartIncluding": "10.0.10240.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_10_1607:*:*:*:*:*:*:x86:*",
                  "versionEndExcluding": "10.0.14393.6897",
                  "versionStartIncluding": "10.0.14393.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2016:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.14393.6897",
                  "versionStartIncluding": "10.0.14393.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2016:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.14393.6897",
                  "versionStartIncluding": "10.0.14393.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2012:*:*:*:*:*:*:x64:*",
                  "versionEndExcluding": "6.2.9200.24821",
                  "versionStartIncluding": "6.2.9200.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2012:*:*:*:*:*:*:x64:*",
                  "versionEndExcluding": "6.2.9200.24821",
                  "versionStartIncluding": "6.2.9200.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2012_R2:*:*:*:*:*:*:x64:*",
                  "versionEndExcluding": "6.3.9600.21924",
                  "versionStartIncluding": "6.3.9600.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2012_R2:*:*:*:*:*:*:x64:*",
                  "versionEndExcluding": "6.3.9600.21924",
                  "versionStartIncluding": "6.3.9600.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "datePublic": "2024-04-09T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en-US",
          "value": "Secure Boot Security Feature Bypass Vulnerability"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en-US",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en-US",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-05-03T00:39:20.099Z",
        "orgId": "f38d906d-7342-40ea-92c1-6c4a2c6478c8",
        "shortName": "microsoft"
      },
      "references": [
        {
          "name": "Secure Boot Security Feature Bypass Vulnerability",
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://msrc.microsoft.com/update-guide/vulnerability/CVE-2024-28898"
        }
      ],
      "title": "Secure Boot Security Feature Bypass Vulnerability"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f38d906d-7342-40ea-92c1-6c4a2c6478c8",
    "assignerShortName": "microsoft",
    "cveId": "CVE-2024-28898",
    "datePublished": "2024-04-09T17:00:19.273Z",
    "dateReserved": "2024-03-13T01:26:53.024Z",
    "dateUpdated": "2025-05-03T00:39:20.099Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-28899 (GCVE-0-2024-28899)

Vulnerability from cvelistv5 – Published: 2024-07-09 17:02 – Updated: 2026-02-10 23:34
VLAI
Title
Secure Boot Security Feature Bypass Vulnerability
Summary
Secure Boot Security Feature Bypass Vulnerability
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Microsoft Windows 10 Version 1809 Affected: 10.0.17763.0 , < 10.0.17763.6054 (custom)
Create a notification for this product.
Microsoft Windows Server 2019 Affected: 10.0.17763.0 , < 10.0.17763.6054 (custom)
Create a notification for this product.
Microsoft Windows Server 2019 (Server Core installation) Affected: 10.0.17763.0 , < 10.0.17763.6054 (custom)
Create a notification for this product.
Microsoft Windows Server 2022 Affected: 10.0.20348.0 , < 10.0.20348.2582 (custom)
Create a notification for this product.
Microsoft Windows 11 version 21H2 Affected: 10.0.0 , < 10.0.22000.3079 (custom)
Create a notification for this product.
Microsoft Windows 10 Version 21H2 Affected: 10.0.19043.0 , < 10.0.19044.4651 (custom)
Create a notification for this product.
Microsoft Windows 11 version 22H2 Affected: 10.0.22621.0 , < 10.0.22621.3880 (custom)
Create a notification for this product.
Microsoft Windows 10 Version 22H2 Affected: 10.0.19045.0 , < 10.0.19045.4651 (custom)
Create a notification for this product.
Microsoft Windows 11 version 22H3 Affected: 10.0.22631.0 , < 10.0.22631.3880 (custom)
Create a notification for this product.
Microsoft Windows 11 Version 23H2 Affected: 10.0.22631.0 , < 10.0.22631.3880 (custom)
Create a notification for this product.
Microsoft Windows Server 2022, 23H2 Edition (Server Core installation) Affected: 10.0.25398.0 , < 10.0.25398.1009 (custom)
Create a notification for this product.
Microsoft Windows 10 Version 1507 Affected: 10.0.10240.0 , < 10.0.10240.20710 (custom)
Create a notification for this product.
Microsoft Windows 10 Version 1607 Affected: 10.0.14393.0 , < 10.0.14393.7159 (custom)
Create a notification for this product.
Microsoft Windows Server 2016 Affected: 10.0.14393.0 , < 10.0.14393.7159 (custom)
Create a notification for this product.
Microsoft Windows Server 2016 (Server Core installation) Affected: 10.0.14393.0 , < 10.0.14393.7159 (custom)
Create a notification for this product.
Microsoft Windows Server 2012 Affected: 6.2.9200.0 , < 6.2.9200.24975 (custom)
Create a notification for this product.
Microsoft Windows Server 2012 (Server Core installation) Affected: 6.2.9200.0 , < 6.2.9200.24975 (custom)
Create a notification for this product.
Microsoft Windows Server 2012 R2 Affected: 6.3.9600.0 , < 6.3.9600.22074 (custom)
Create a notification for this product.
Microsoft Windows Server 2012 R2 (Server Core installation) Affected: 6.3.9600.0 , < 6.3.9600.22074 (custom)
Create a notification for this product.
Date Public
2024-07-09 07:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-28899",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-10T15:42:02.815815Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-10T15:42:14.941Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:03:50.646Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "Secure Boot Security Feature Bypass Vulnerability",
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://msrc.microsoft.com/update-guide/vulnerability/CVE-2024-28899"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "platforms": [
            "32-bit Systems",
            "x64-based Systems"
          ],
          "product": "Windows 10 Version 1809",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.17763.6054",
              "status": "affected",
              "version": "10.0.17763.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2019",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.17763.6054",
              "status": "affected",
              "version": "10.0.17763.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2019 (Server Core installation)",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.17763.6054",
              "status": "affected",
              "version": "10.0.17763.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2022",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.20348.2582",
              "status": "affected",
              "version": "10.0.20348.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems",
            "ARM64-based Systems"
          ],
          "product": "Windows 11 version 21H2",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.22000.3079",
              "status": "affected",
              "version": "10.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "32-bit Systems",
            "ARM64-based Systems",
            "x64-based Systems"
          ],
          "product": "Windows 10 Version 21H2",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.19044.4651",
              "status": "affected",
              "version": "10.0.19043.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "ARM64-based Systems",
            "x64-based Systems"
          ],
          "product": "Windows 11 version 22H2",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.22621.3880",
              "status": "affected",
              "version": "10.0.22621.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems",
            "ARM64-based Systems",
            "32-bit Systems"
          ],
          "product": "Windows 10 Version 22H2",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.19045.4651",
              "status": "affected",
              "version": "10.0.19045.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "ARM64-based Systems"
          ],
          "product": "Windows 11 version 22H3",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.22631.3880",
              "status": "affected",
              "version": "10.0.22631.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows 11 Version 23H2",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.22631.3880",
              "status": "affected",
              "version": "10.0.22631.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2022, 23H2 Edition (Server Core installation)",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.25398.1009",
              "status": "affected",
              "version": "10.0.25398.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "32-bit Systems",
            "x64-based Systems"
          ],
          "product": "Windows 10 Version 1507",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.10240.20710",
              "status": "affected",
              "version": "10.0.10240.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "32-bit Systems",
            "x64-based Systems"
          ],
          "product": "Windows 10 Version 1607",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.14393.7159",
              "status": "affected",
              "version": "10.0.14393.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2016",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.14393.7159",
              "status": "affected",
              "version": "10.0.14393.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2016 (Server Core installation)",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.14393.7159",
              "status": "affected",
              "version": "10.0.14393.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2012",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "6.2.9200.24975",
              "status": "affected",
              "version": "6.2.9200.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2012 (Server Core installation)",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "6.2.9200.24975",
              "status": "affected",
              "version": "6.2.9200.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2012 R2",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "6.3.9600.22074",
              "status": "affected",
              "version": "6.3.9600.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2012 R2 (Server Core installation)",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "6.3.9600.22074",
              "status": "affected",
              "version": "6.3.9600.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_10_1809:*:*:*:*:*:*:x86:*",
                  "versionEndExcluding": "10.0.17763.6054",
                  "versionStartIncluding": "10.0.17763.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2019:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.17763.6054",
                  "versionStartIncluding": "10.0.17763.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2019:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.17763.6054",
                  "versionStartIncluding": "10.0.17763.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2022:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.20348.2582",
                  "versionStartIncluding": "10.0.20348.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_11_21H2:*:*:*:*:*:*:x64:*",
                  "versionEndExcluding": "10.0.22000.3079",
                  "versionStartIncluding": "10.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_10_21H2:*:*:*:*:*:*:x86:*",
                  "versionEndExcluding": "10.0.19044.4651",
                  "versionStartIncluding": "10.0.19043.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_11_22H2:*:*:*:*:*:*:arm64:*",
                  "versionEndExcluding": "10.0.22621.3880",
                  "versionStartIncluding": "10.0.22621.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_10_22H2:*:*:*:*:*:*:x64:*",
                  "versionEndExcluding": "10.0.19045.4651",
                  "versionStartIncluding": "10.0.19045.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_11_23H2:*:*:*:*:*:*:arm64:*",
                  "versionEndExcluding": "10.0.22631.3880",
                  "versionStartIncluding": "10.0.22631.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_11_23H2:*:*:*:*:*:*:x64:*",
                  "versionEndExcluding": "10.0.22631.3880",
                  "versionStartIncluding": "10.0.22631.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_23h2:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.25398.1009",
                  "versionStartIncluding": "10.0.25398.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_10_1507:*:*:*:*:*:*:x86:*",
                  "versionEndExcluding": "10.0.10240.20710",
                  "versionStartIncluding": "10.0.10240.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_10_1607:*:*:*:*:*:*:x86:*",
                  "versionEndExcluding": "10.0.14393.7159",
                  "versionStartIncluding": "10.0.14393.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2016:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.14393.7159",
                  "versionStartIncluding": "10.0.14393.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2016:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.14393.7159",
                  "versionStartIncluding": "10.0.14393.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2012:*:*:*:*:*:*:x64:*",
                  "versionEndExcluding": "6.2.9200.24975",
                  "versionStartIncluding": "6.2.9200.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2012:*:*:*:*:*:*:x64:*",
                  "versionEndExcluding": "6.2.9200.24975",
                  "versionStartIncluding": "6.2.9200.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2012_R2:*:*:*:*:*:*:x64:*",
                  "versionEndExcluding": "6.3.9600.22074",
                  "versionStartIncluding": "6.3.9600.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2012_R2:*:*:*:*:*:*:x64:*",
                  "versionEndExcluding": "6.3.9600.22074",
                  "versionStartIncluding": "6.3.9600.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "datePublic": "2024-07-09T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en-US",
          "value": "Secure Boot Security Feature Bypass Vulnerability"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en-US",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en-US",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-02-10T23:34:06.749Z",
        "orgId": "f38d906d-7342-40ea-92c1-6c4a2c6478c8",
        "shortName": "microsoft"
      },
      "references": [
        {
          "name": "Secure Boot Security Feature Bypass Vulnerability",
          "tags": [
            "vendor-advisory",
            "patch"
          ],
          "url": "https://msrc.microsoft.com/update-guide/vulnerability/CVE-2024-28899"
        }
      ],
      "title": "Secure Boot Security Feature Bypass Vulnerability"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f38d906d-7342-40ea-92c1-6c4a2c6478c8",
    "assignerShortName": "microsoft",
    "cveId": "CVE-2024-28899",
    "datePublished": "2024-07-09T17:02:08.251Z",
    "dateReserved": "2024-03-13T01:26:53.024Z",
    "dateUpdated": "2026-02-10T23:34:06.749Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

Mitigation ID: MIT-10

Phases: Operation, Build and Compilation

Strategy: Environment Hardening

Description:

  • Use automatic buffer overflow detection mechanisms that are offered by certain compilers or compiler extensions. Examples include: the Microsoft Visual Studio /GS flag, Fedora/Red Hat FORTIFY_SOURCE GCC flag, StackGuard, and ProPolice, which provide various mechanisms including canary-based detection and range/index checking.
  • D3-SFCV (Stack Frame Canary Validation) from D3FEND [REF-1334] discusses canary-based detection in detail.
Mitigation

Phase: Architecture and Design

Description:

  • Use an abstraction library to abstract away risky APIs. Not a complete solution.
Mitigation

Phase: Implementation

Description:

  • Implement and perform bounds checking on input.
Mitigation

Phase: Implementation

Description:

  • Do not use dangerous functions such as gets. Use safer, equivalent functions which check for boundary errors.
Mitigation ID: MIT-11

Phases: Operation, Build and Compilation

Strategy: Environment Hardening

Description:

  • Run or compile the software using features or extensions that randomly arrange the positions of a program's executable and libraries in memory. Because this makes the addresses unpredictable, it can prevent an attacker from reliably jumping to exploitable code.
  • Examples include Address Space Layout Randomization (ASLR) [REF-58] [REF-60] and Position-Independent Executables (PIE) [REF-64]. Imported modules may be similarly realigned if their default memory addresses conflict with other modules, in a process known as "rebasing" (for Windows) and "prelinking" (for Linux) [REF-1332] using randomly generated addresses. ASLR for libraries cannot be used in conjunction with prelink since it would require relocating the libraries at run-time, defeating the whole purpose of prelinking.
  • For more information on these techniques see D3-SAOR (Segment Address Offset Randomization) from D3FEND [REF-1335].

No CAPEC attack patterns related to this CWE.

Back to CWE stats page