CWE-121

Stack-based Buffer Overflow

A stack-based buffer overflow condition is a condition where the buffer being overwritten is allocated on the stack (i.e., is a local variable or, rarely, a parameter to a function).

CVE-2024-2898 (GCVE-0-2024-2898)

Vulnerability from cvelistv5 – Published: 2024-03-26 18:31 – Updated: 2024-08-01 19:25
VLAI
Title
Tenda AC7 SetStaticRouteCfg fromSetRouteStatic stack-based overflow
Summary
A vulnerability classified as critical was found in Tenda AC7 15.03.06.44. Affected by this vulnerability is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257941 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.257941 vdb-entrytechnical-description
https://vuldb.com/?ctiid.257941 signaturepermissions-required
https://vuldb.com/?submit.300361 third-party-advisory
https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
Impacted products
Vendor Product Version
Tenda AC7 Affected: 15.03.06.44
Create a notification for this product.
tenda ac7_firmware Affected: 15.03.06.44
    cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*
Create a notification for this product.
Credits
wxhwxhwxh_tutu (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac7_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.44"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2898",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-16T21:02:27.145376Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-16T21:03:00.476Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:25:42.160Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-257941 | Tenda AC7 SetStaticRouteCfg fromSetRouteStatic stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.257941"
          },
          {
            "name": "VDB-257941 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.257941"
          },
          {
            "name": "Submit #300361 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.300361"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/fromSetRouteStatic.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC7",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.06.44"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_tutu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical was found in Tenda AC7 15.03.06.44. Affected by this vulnerability is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257941 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In Tenda AC7 15.03.06.44 wurde eine kritische Schwachstelle entdeckt. Das betrifft die Funktion fromSetRouteStatic der Datei /goform/SetStaticRouteCfg. Mit der Manipulation des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-26T18:31:05.622Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-257941 | Tenda AC7 SetStaticRouteCfg fromSetRouteStatic stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.257941"
        },
        {
          "name": "VDB-257941 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.257941"
        },
        {
          "name": "Submit #300361 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.300361"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/fromSetRouteStatic.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-26T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-26T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-26T10:31:07.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC7 SetStaticRouteCfg fromSetRouteStatic stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2898",
    "datePublished": "2024-03-26T18:31:05.622Z",
    "dateReserved": "2024-03-26T09:26:00.834Z",
    "dateUpdated": "2024-08-01T19:25:42.160Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-2899 (GCVE-0-2024-2899)

Vulnerability from cvelistv5 – Published: 2024-03-26 19:00 – Updated: 2025-04-10 18:28
VLAI
Title
Tenda AC7 WifiExtraSet fromSetWirelessRepeat stack-based overflow
Summary
A vulnerability, which was classified as critical, has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257942 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.257942 vdb-entrytechnical-description
https://vuldb.com/?ctiid.257942 signaturepermissions-required
https://vuldb.com/?submit.300362 third-party-advisory
https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
Impacted products
Vendor Product Version
Tenda AC7 Affected: 15.03.06.44
Create a notification for this product.
tenda ac7 Affected: 15.03.06.44
    cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*
Create a notification for this product.
Credits
wxhwxhwxh_tutu (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac7",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.44"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2899",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-16T17:43:12.540684Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-10T18:28:47.028Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:25:42.223Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-257942 | Tenda AC7 WifiExtraSet fromSetWirelessRepeat stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.257942"
          },
          {
            "name": "VDB-257942 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.257942"
          },
          {
            "name": "Submit #300362 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.300362"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/fromSetWirelessRepeat.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC7",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.06.44"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_tutu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, which was classified as critical, has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257942 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine kritische Schwachstelle wurde in Tenda AC7 15.03.06.44 entdeckt. Dies betrifft die Funktion fromSetWirelessRepeat der Datei /goform/WifiExtraSet. Durch die Manipulation des Arguments wpapsk_crypto mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-26T19:00:07.170Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-257942 | Tenda AC7 WifiExtraSet fromSetWirelessRepeat stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.257942"
        },
        {
          "name": "VDB-257942 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.257942"
        },
        {
          "name": "Submit #300362 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.300362"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/fromSetWirelessRepeat.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-26T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-26T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-26T10:31:13.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC7 WifiExtraSet fromSetWirelessRepeat stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2899",
    "datePublished": "2024-03-26T19:00:07.170Z",
    "dateReserved": "2024-03-26T09:26:06.184Z",
    "dateUpdated": "2025-04-10T18:28:47.028Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-2900 (GCVE-0-2024-2900)

Vulnerability from cvelistv5 – Published: 2024-03-26 19:31 – Updated: 2024-08-01 19:25
VLAI
Title
Tenda AC7 saveParentControlInfo stack-based overflow
Summary
A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. This affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument deviceId/time/urls leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257943. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.257943 vdb-entrytechnical-description
https://vuldb.com/?ctiid.257943 signaturepermissions-required
https://vuldb.com/?submit.300364 third-party-advisory
https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
Impacted products
Vendor Product Version
Tenda AC7 Affected: 15.03.06.44
Create a notification for this product.
tenda ac7_firmware Affected: 15.03.06.44
    cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*
Create a notification for this product.
Credits
wxhwxhwxh_tutu (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac7_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.44"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2900",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-01T18:06:26.520903Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-01T18:08:23.914Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:25:42.144Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-257943 | Tenda AC7 saveParentControlInfo stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.257943"
          },
          {
            "name": "VDB-257943 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.257943"
          },
          {
            "name": "Submit #300364 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.300364"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/saveParentControlInfo_deviceId.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC7",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.06.44"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_tutu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. This affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument deviceId/time/urls leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257943. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Es wurde eine kritische Schwachstelle in Tenda AC7 15.03.06.44 gefunden. Dabei betrifft es die Funktion saveParentControlInfo der Datei /goform/saveParentControlInfo. Durch Manipulation des Arguments deviceId/time/urls mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-26T19:31:04.524Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-257943 | Tenda AC7 saveParentControlInfo stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.257943"
        },
        {
          "name": "VDB-257943 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.257943"
        },
        {
          "name": "Submit #300364 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.300364"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/saveParentControlInfo_deviceId.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-26T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-26T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-26T10:31:26.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC7 saveParentControlInfo stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2900",
    "datePublished": "2024-03-26T19:31:04.524Z",
    "dateReserved": "2024-03-26T09:26:11.290Z",
    "dateUpdated": "2024-08-01T19:25:42.144Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-2901 (GCVE-0-2024-2901)

Vulnerability from cvelistv5 – Published: 2024-03-26 20:00 – Updated: 2024-08-29 19:09
VLAI
Title
Tenda AC7 openSchedWifi setSchedWifi stack-based overflow
Summary
A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257944. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.257944 vdb-entrytechnical-description
https://vuldb.com/?ctiid.257944 signaturepermissions-required
https://vuldb.com/?submit.300367 third-party-advisory
https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
Impacted products
Vendor Product Version
Tenda AC7 Affected: 15.03.06.44
Create a notification for this product.
tenda ac7 Affected: 15.03.06.44
    cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*
Create a notification for this product.
Credits
wxhwxhwxh_tutu (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:25:42.161Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-257944 | Tenda AC7 openSchedWifi setSchedWifi stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.257944"
          },
          {
            "name": "VDB-257944 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.257944"
          },
          {
            "name": "Submit #300367 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.300367"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/setSchedWifi.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac7",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.44"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2901",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-20T20:50:19.200809Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-29T19:09:39.749Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC7",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.06.44"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_tutu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257944. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In Tenda AC7 15.03.06.44 wurde eine kritische Schwachstelle gefunden. Hierbei betrifft es die Funktion setSchedWifi der Datei /goform/openSchedWifi. Mittels dem Manipulieren des Arguments schedEndTime mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-26T20:00:06.887Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-257944 | Tenda AC7 openSchedWifi setSchedWifi stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.257944"
        },
        {
          "name": "VDB-257944 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.257944"
        },
        {
          "name": "Submit #300367 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.300367"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/setSchedWifi.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-26T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-26T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-26T10:31:39.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC7 openSchedWifi setSchedWifi stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2901",
    "datePublished": "2024-03-26T20:00:06.887Z",
    "dateReserved": "2024-03-26T09:26:24.727Z",
    "dateUpdated": "2024-08-29T19:09:39.749Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-29012 (GCVE-0-2024-29012)

Vulnerability from cvelistv5 – Published: 2024-06-20 08:11 – Updated: 2025-03-25 16:30
VLAI
Summary
Stack-based buffer overflow vulnerability in the SonicOS HTTP server allows an authenticated remote attacker to cause Denial of Service (DoS) via sscanf function.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
SonicWall SonicOS Affected: 7.1.1-7051 and earlier versions
Create a notification for this product.
Date Public
2024-06-20 08:01
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 4.9,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "HIGH",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-29012",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-27T13:21:49.382881Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-25T16:30:24.601Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:03:51.511Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2024-0008"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "platforms": [
            "Gen7"
          ],
          "product": "SonicOS",
          "vendor": "SonicWall",
          "versions": [
            {
              "status": "affected",
              "version": "7.1.1-7051 and earlier versions"
            }
          ]
        }
      ],
      "datePublic": "2024-06-20T08:01:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Stack-based buffer overflow vulnerability in the SonicOS HTTP server allows an authenticated remote attacker to cause Denial of Service (DoS) via sscanf function."
            }
          ],
          "value": "Stack-based buffer overflow vulnerability in the SonicOS HTTP server allows an authenticated remote attacker to cause Denial of Service (DoS) via sscanf function."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-20T08:11:10.318Z",
        "orgId": "44b2ff79-1416-4492-88bb-ed0da00c7315",
        "shortName": "sonicwall"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2024-0008"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "44b2ff79-1416-4492-88bb-ed0da00c7315",
    "assignerShortName": "sonicwall",
    "cveId": "CVE-2024-29012",
    "datePublished": "2024-06-20T08:11:10.318Z",
    "dateReserved": "2024-03-14T03:29:41.180Z",
    "dateUpdated": "2025-03-25T16:30:24.601Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-2902 (GCVE-0-2024-2902)

Vulnerability from cvelistv5 – Published: 2024-03-26 20:00 – Updated: 2024-08-12 13:35
VLAI
Title
Tenda AC7 WifiGuestSet fromSetWifiGusetBasic stack-based overflow
Summary
A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function fromSetWifiGusetBasic of the file /goform/WifiGuestSet. The manipulation of the argument shareSpeed leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257945 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.257945 vdb-entrytechnical-description
https://vuldb.com/?ctiid.257945 signaturepermissions-required
https://vuldb.com/?submit.300449 third-party-advisory
https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
Impacted products
Vendor Product Version
Tenda AC7 Affected: 15.03.06.44
Create a notification for this product.
tenda ac7_firmware Affected: 15.03.06.44
    cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*
Create a notification for this product.
Credits
wxhwxhwxh_tutu (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:25:42.155Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-257945 | Tenda AC7 WifiGuestSet fromSetWifiGusetBasic stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.257945"
          },
          {
            "name": "VDB-257945 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.257945"
          },
          {
            "name": "Submit #300449 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.300449"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/fromSetWifiGusetBasic.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac7_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.44"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2902",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-15T19:37:20.952602Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-12T13:35:50.633Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC7",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.06.44"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_tutu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function fromSetWifiGusetBasic of the file /goform/WifiGuestSet. The manipulation of the argument shareSpeed leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257945 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine kritische Schwachstelle wurde in Tenda AC7 15.03.06.44 gefunden. Davon betroffen ist die Funktion fromSetWifiGusetBasic der Datei /goform/WifiGuestSet. Mittels Manipulieren des Arguments shareSpeed mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-26T20:00:08.534Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-257945 | Tenda AC7 WifiGuestSet fromSetWifiGusetBasic stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.257945"
        },
        {
          "name": "VDB-257945 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.257945"
        },
        {
          "name": "Submit #300449 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.300449"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/fromSetWifiGusetBasic.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-26T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-26T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-26T10:31:44.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC7 WifiGuestSet fromSetWifiGusetBasic stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2902",
    "datePublished": "2024-03-26T20:00:08.534Z",
    "dateReserved": "2024-03-26T09:26:38.442Z",
    "dateUpdated": "2024-08-12T13:35:50.633Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-2903 (GCVE-0-2024-2903)

Vulnerability from cvelistv5 – Published: 2024-03-26 20:31 – Updated: 2024-08-15 15:54
VLAI
Title
Tenda AC7 GetParentControlInfo stack-based overflow
Summary
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257946 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.257946 vdb-entrytechnical-description
https://vuldb.com/?ctiid.257946 signaturepermissions-required
https://vuldb.com/?submit.300452 third-party-advisory
https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
Impacted products
Vendor Product Version
Tenda AC7 Affected: 15.03.06.44
Create a notification for this product.
tenda ac7 Affected: 15.03.06.44
    cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*
Create a notification for this product.
Credits
wxhwxhwxh_tutu (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:25:42.219Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-257946 | Tenda AC7 GetParentControlInfo stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.257946"
          },
          {
            "name": "VDB-257946 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.257946"
          },
          {
            "name": "Submit #300452 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.300452"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/GetParentControlInfo.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac7",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.06.44"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2903",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-15T15:52:57.072819Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-15T15:54:17.573Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC7",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "15.03.06.44"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_tutu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257946 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Es wurde eine kritische Schwachstelle in Tenda AC7 15.03.06.44 ausgemacht. Hiervon betroffen ist die Funktion GetParentControlInfo der Datei /goform/GetParentControlInfo. Durch das Manipulieren des Arguments mac mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-26T20:31:04.040Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-257946 | Tenda AC7 GetParentControlInfo stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.257946"
        },
        {
          "name": "VDB-257946 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.257946"
        },
        {
          "name": "Submit #300452 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.300452"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/GetParentControlInfo.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-26T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-26T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-26T10:31:50.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC7 GetParentControlInfo stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2903",
    "datePublished": "2024-03-26T20:31:04.040Z",
    "dateReserved": "2024-03-26T09:26:47.360Z",
    "dateUpdated": "2024-08-15T15:54:17.573Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-29045 (GCVE-0-2024-29045)

Vulnerability from cvelistv5 – Published: 2024-04-09 17:00 – Updated: 2025-05-03 00:39
VLAI
Title
Microsoft OLE DB Driver for SQL Server Remote Code Execution Vulnerability
Summary
Microsoft OLE DB Driver for SQL Server Remote Code Execution Vulnerability
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Date Public
2024-04-09 07:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-29045",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-01T17:48:39.679827Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:57:59.578Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:03:51.672Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "Microsoft OLE DB Driver for SQL Server Remote Code Execution Vulnerability",
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://msrc.microsoft.com/update-guide/vulnerability/CVE-2024-29045"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Microsoft SQL Server 2019 (CU 25)",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "15.0.4360.2",
              "status": "affected",
              "version": "15.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Microsoft SQL Server 2022 for (CU 12)",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "16.0.4120.1",
              "status": "affected",
              "version": "16.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Microsoft SQL Server 2019 (GDR)",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "15.0.2110.4",
              "status": "affected",
              "version": "15.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Microsoft SQL Server 2022 (GDR)",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "16.0.1115.1",
              "status": "affected",
              "version": "16.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "Unknown"
          ],
          "product": "Microsoft OLE DB Driver 19 for SQL Server",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "19.3.0003.0",
              "status": "affected",
              "version": "19.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "Unknown"
          ],
          "product": "Microsoft OLE DB Driver 18 for SQL Server",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "18.7.0002.0",
              "status": "affected",
              "version": "18.0.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:microsoft:sql_server:*:*:*:*:*:*:x64:*",
                  "versionEndExcluding": "15.0.4360.2",
                  "versionStartIncluding": "15.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:sql_server:*:*:*:*:*:*:x64:*",
                  "versionEndExcluding": "16.0.4120.1",
                  "versionStartIncluding": "16.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:sql_server:*:*:*:*:*:*:x64:*",
                  "versionEndExcluding": "15.0.2110.4",
                  "versionStartIncluding": "15.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:sql_server:*:*:*:*:*:*:x64:*",
                  "versionEndExcluding": "16.0.1115.1",
                  "versionStartIncluding": "16.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:ole_db_driver_19_for_sql_server:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "19.3.0003.0",
                  "versionStartIncluding": "19.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:ole_db_driver_18_for_sql_server:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "18.7.0002.0",
                  "versionStartIncluding": "18.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "datePublic": "2024-04-09T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en-US",
          "value": "Microsoft OLE DB Driver for SQL Server Remote Code Execution Vulnerability"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en-US",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en-US",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-05-03T00:39:32.355Z",
        "orgId": "f38d906d-7342-40ea-92c1-6c4a2c6478c8",
        "shortName": "microsoft"
      },
      "references": [
        {
          "name": "Microsoft OLE DB Driver for SQL Server Remote Code Execution Vulnerability",
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://msrc.microsoft.com/update-guide/vulnerability/CVE-2024-29045"
        }
      ],
      "title": "Microsoft OLE DB Driver for SQL Server Remote Code Execution Vulnerability"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f38d906d-7342-40ea-92c1-6c4a2c6478c8",
    "assignerShortName": "microsoft",
    "cveId": "CVE-2024-29045",
    "datePublished": "2024-04-09T17:00:31.478Z",
    "dateReserved": "2024-03-14T23:05:27.952Z",
    "dateUpdated": "2025-05-03T00:39:32.355Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-29061 (GCVE-0-2024-29061)

Vulnerability from cvelistv5 – Published: 2024-04-09 17:01 – Updated: 2025-05-03 00:40
VLAI
Title
Secure Boot Security Feature Bypass Vulnerability
Summary
Secure Boot Security Feature Bypass Vulnerability
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Microsoft Windows 10 Version 1809 Affected: 10.0.17763.0 , < 10.0.17763.5696 (custom)
Create a notification for this product.
Microsoft Windows 10 Version 1809 Affected: 10.0.0 , < 10.0.17763.5696 (custom)
Create a notification for this product.
Microsoft Windows Server 2019 Affected: 10.0.17763.0 , < 10.0.17763.5696 (custom)
Create a notification for this product.
Microsoft Windows Server 2019 (Server Core installation) Affected: 10.0.17763.0 , < 10.0.17763.5696 (custom)
Create a notification for this product.
Microsoft Windows Server 2022 Affected: 10.0.20348.0 , < 10.0.20348.2402 (custom)
Create a notification for this product.
Microsoft Windows 11 version 21H2 Affected: 10.0.0 , < 10.0.22000.2899 (custom)
Create a notification for this product.
Microsoft Windows 10 Version 21H2 Affected: 10.0.19043.0 , < 10.0.19044.4291 (custom)
Create a notification for this product.
Microsoft Windows 11 version 22H2 Affected: 10.0.22621.0 , < 10.0.22621.3447 (custom)
Create a notification for this product.
Microsoft Windows 10 Version 22H2 Affected: 10.0.19045.0 , < 10.0.19045.4291 (custom)
Create a notification for this product.
Microsoft Windows 11 version 22H3 Affected: 10.0.22631.0 , < 10.0.22631.3447 (custom)
Create a notification for this product.
Microsoft Windows 11 Version 23H2 Affected: 10.0.22631.0 , < 10.0.22631.3447 (custom)
Create a notification for this product.
Microsoft Windows Server 2022, 23H2 Edition (Server Core installation) Affected: 10.0.25398.0 , < 10.0.25398.830 (custom)
Create a notification for this product.
Microsoft Windows 10 Version 1507 Affected: 10.0.10240.0 , < 10.0.10240.20596 (custom)
Create a notification for this product.
Microsoft Windows 10 Version 1607 Affected: 10.0.14393.0 , < 10.0.14393.6897 (custom)
Create a notification for this product.
Microsoft Windows Server 2016 Affected: 10.0.14393.0 , < 10.0.14393.6897 (custom)
Create a notification for this product.
Microsoft Windows Server 2016 (Server Core installation) Affected: 10.0.14393.0 , < 10.0.14393.6897 (custom)
Create a notification for this product.
Microsoft Windows Server 2012 Affected: 6.2.9200.0 , < 6.2.9200.24821 (custom)
Create a notification for this product.
Microsoft Windows Server 2012 (Server Core installation) Affected: 6.2.9200.0 , < 6.2.9200.24821 (custom)
Create a notification for this product.
Microsoft Windows Server 2012 R2 Affected: 6.3.9600.0 , < 6.3.9600.21924 (custom)
Create a notification for this product.
Microsoft Windows Server 2012 R2 (Server Core installation) Affected: 6.3.9600.0 , < 6.3.9600.21924 (custom)
Create a notification for this product.
Date Public
2024-04-09 07:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:03:51.753Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "Secure Boot Security Feature Bypass Vulnerability",
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://msrc.microsoft.com/update-guide/vulnerability/CVE-2024-29061"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-29061",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-10T19:51:50.520053Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-12T17:32:37.253Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "platforms": [
            "32-bit Systems",
            "x64-based Systems"
          ],
          "product": "Windows 10 Version 1809",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.17763.5696",
              "status": "affected",
              "version": "10.0.17763.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "ARM64-based Systems"
          ],
          "product": "Windows 10 Version 1809",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.17763.5696",
              "status": "affected",
              "version": "10.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2019",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.17763.5696",
              "status": "affected",
              "version": "10.0.17763.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2019 (Server Core installation)",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.17763.5696",
              "status": "affected",
              "version": "10.0.17763.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2022",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.20348.2402",
              "status": "affected",
              "version": "10.0.20348.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems",
            "ARM64-based Systems"
          ],
          "product": "Windows 11 version 21H2",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.22000.2899",
              "status": "affected",
              "version": "10.0.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "32-bit Systems",
            "ARM64-based Systems",
            "x64-based Systems"
          ],
          "product": "Windows 10 Version 21H2",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.19044.4291",
              "status": "affected",
              "version": "10.0.19043.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "ARM64-based Systems",
            "x64-based Systems"
          ],
          "product": "Windows 11 version 22H2",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.22621.3447",
              "status": "affected",
              "version": "10.0.22621.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems",
            "ARM64-based Systems",
            "32-bit Systems"
          ],
          "product": "Windows 10 Version 22H2",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.19045.4291",
              "status": "affected",
              "version": "10.0.19045.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "ARM64-based Systems"
          ],
          "product": "Windows 11 version 22H3",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.22631.3447",
              "status": "affected",
              "version": "10.0.22631.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows 11 Version 23H2",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.22631.3447",
              "status": "affected",
              "version": "10.0.22631.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2022, 23H2 Edition (Server Core installation)",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.25398.830",
              "status": "affected",
              "version": "10.0.25398.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "32-bit Systems",
            "x64-based Systems"
          ],
          "product": "Windows 10 Version 1507",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.10240.20596",
              "status": "affected",
              "version": "10.0.10240.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "32-bit Systems",
            "x64-based Systems"
          ],
          "product": "Windows 10 Version 1607",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.14393.6897",
              "status": "affected",
              "version": "10.0.14393.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2016",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.14393.6897",
              "status": "affected",
              "version": "10.0.14393.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2016 (Server Core installation)",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.14393.6897",
              "status": "affected",
              "version": "10.0.14393.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2012",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "6.2.9200.24821",
              "status": "affected",
              "version": "6.2.9200.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2012 (Server Core installation)",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "6.2.9200.24821",
              "status": "affected",
              "version": "6.2.9200.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2012 R2",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "6.3.9600.21924",
              "status": "affected",
              "version": "6.3.9600.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2012 R2 (Server Core installation)",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "6.3.9600.21924",
              "status": "affected",
              "version": "6.3.9600.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_10_1809:*:*:*:*:*:*:x86:*",
                  "versionEndExcluding": "10.0.17763.5696",
                  "versionStartIncluding": "10.0.17763.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_10_1809:*:*:*:*:*:*:arm64:*",
                  "versionEndExcluding": "10.0.17763.5696",
                  "versionStartIncluding": "10.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2019:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.17763.5696",
                  "versionStartIncluding": "10.0.17763.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2019:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.17763.5696",
                  "versionStartIncluding": "10.0.17763.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2022:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.20348.2402",
                  "versionStartIncluding": "10.0.20348.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_11_21H2:*:*:*:*:*:*:x64:*",
                  "versionEndExcluding": "10.0.22000.2899",
                  "versionStartIncluding": "10.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_10_21H2:*:*:*:*:*:*:x86:*",
                  "versionEndExcluding": "10.0.19044.4291",
                  "versionStartIncluding": "10.0.19043.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_11_22H2:*:*:*:*:*:*:arm64:*",
                  "versionEndExcluding": "10.0.22621.3447",
                  "versionStartIncluding": "10.0.22621.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_10_22H2:*:*:*:*:*:*:x64:*",
                  "versionEndExcluding": "10.0.19045.4291",
                  "versionStartIncluding": "10.0.19045.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_11_23H2:*:*:*:*:*:*:arm64:*",
                  "versionEndExcluding": "10.0.22631.3447",
                  "versionStartIncluding": "10.0.22631.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_11_23H2:*:*:*:*:*:*:x64:*",
                  "versionEndExcluding": "10.0.22631.3447",
                  "versionStartIncluding": "10.0.22631.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_23h2:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.25398.830",
                  "versionStartIncluding": "10.0.25398.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_10_1507:*:*:*:*:*:*:x86:*",
                  "versionEndExcluding": "10.0.10240.20596",
                  "versionStartIncluding": "10.0.10240.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_10_1607:*:*:*:*:*:*:x86:*",
                  "versionEndExcluding": "10.0.14393.6897",
                  "versionStartIncluding": "10.0.14393.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2016:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.14393.6897",
                  "versionStartIncluding": "10.0.14393.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2016:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.14393.6897",
                  "versionStartIncluding": "10.0.14393.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2012:*:*:*:*:*:*:x64:*",
                  "versionEndExcluding": "6.2.9200.24821",
                  "versionStartIncluding": "6.2.9200.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2012:*:*:*:*:*:*:x64:*",
                  "versionEndExcluding": "6.2.9200.24821",
                  "versionStartIncluding": "6.2.9200.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2012_R2:*:*:*:*:*:*:x64:*",
                  "versionEndExcluding": "6.3.9600.21924",
                  "versionStartIncluding": "6.3.9600.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2012_R2:*:*:*:*:*:*:x64:*",
                  "versionEndExcluding": "6.3.9600.21924",
                  "versionStartIncluding": "6.3.9600.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "datePublic": "2024-04-09T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en-US",
          "value": "Secure Boot Security Feature Bypass Vulnerability"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en-US",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en-US",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-05-03T00:40:25.434Z",
        "orgId": "f38d906d-7342-40ea-92c1-6c4a2c6478c8",
        "shortName": "microsoft"
      },
      "references": [
        {
          "name": "Secure Boot Security Feature Bypass Vulnerability",
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://msrc.microsoft.com/update-guide/vulnerability/CVE-2024-29061"
        }
      ],
      "title": "Secure Boot Security Feature Bypass Vulnerability"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f38d906d-7342-40ea-92c1-6c4a2c6478c8",
    "assignerShortName": "microsoft",
    "cveId": "CVE-2024-29061",
    "datePublished": "2024-04-09T17:01:23.740Z",
    "dateReserved": "2024-03-14T23:05:27.955Z",
    "dateUpdated": "2025-05-03T00:40:25.434Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-2976 (GCVE-0-2024-2976)

Vulnerability from cvelistv5 – Published: 2024-03-27 13:31 – Updated: 2024-08-21 14:56
VLAI
Title
Tenda F1203 execCommand R7WebsSecurityHandler stack-based overflow
Summary
A vulnerability was found in Tenda F1203 2.0.1.6. It has been declared as critical. Affected by this vulnerability is the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
URL Tags
https://vuldb.com/?id.258145 vdb-entrytechnical-description
https://vuldb.com/?ctiid.258145 signaturepermissions-required
https://vuldb.com/?submit.300997 third-party-advisory
https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
Impacted products
Vendor Product Version
Tenda F1203 Affected: 2.0.1.6
Create a notification for this product.
tenda f1203_firmware Affected: 2.0.1.6
    cpe:2.3:o:tenda:f1203_firmware:2.0.1.6:*:*:*:*:*:*:*
Create a notification for this product.
Credits
wxhwxhwxh_tutu (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:32:42.512Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-258145 | Tenda F1203 execCommand R7WebsSecurityHandler stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.258145"
          },
          {
            "name": "VDB-258145 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.258145"
          },
          {
            "name": "Submit #300997 | Tenda F1203 V2.0.1.6 buffer overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.300997"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1203/R7WebsSecurityHandler.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:f1203_firmware:2.0.1.6:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "f1203_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "2.0.1.6"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2976",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-21T14:54:24.131979Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-21T14:56:30.998Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "F1203",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "2.0.1.6"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_tutu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda F1203 2.0.1.6. It has been declared as critical. Affected by this vulnerability is the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In Tenda F1203 2.0.1.6 wurde eine kritische Schwachstelle ausgemacht. Es geht um die Funktion R7WebsSecurityHandler der Datei /goform/execCommand. Durch Manipulieren des Arguments password mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-27T13:31:04.472Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-258145 | Tenda F1203 execCommand R7WebsSecurityHandler stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.258145"
        },
        {
          "name": "VDB-258145 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.258145"
        },
        {
          "name": "Submit #300997 | Tenda F1203 V2.0.1.6 buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.300997"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1203/R7WebsSecurityHandler.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-03-27T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-03-27T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-03-27T08:09:57.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda F1203 execCommand R7WebsSecurityHandler stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-2976",
    "datePublished": "2024-03-27T13:31:04.472Z",
    "dateReserved": "2024-03-27T07:03:52.505Z",
    "dateUpdated": "2024-08-21T14:56:30.998Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation ID: MIT-10

Phases: Operation, Build and Compilation

Strategy: Environment Hardening

Description:

  • Use automatic buffer overflow detection mechanisms that are offered by certain compilers or compiler extensions. Examples include: the Microsoft Visual Studio /GS flag, Fedora/Red Hat FORTIFY_SOURCE GCC flag, StackGuard, and ProPolice, which provide various mechanisms including canary-based detection and range/index checking.
  • D3-SFCV (Stack Frame Canary Validation) from D3FEND [REF-1334] discusses canary-based detection in detail.
Mitigation

Phase: Architecture and Design

Description:

  • Use an abstraction library to abstract away risky APIs. Not a complete solution.
Mitigation

Phase: Implementation

Description:

  • Implement and perform bounds checking on input.
Mitigation

Phase: Implementation

Description:

  • Do not use dangerous functions such as gets. Use safer, equivalent functions which check for boundary errors.
Mitigation ID: MIT-11

Phases: Operation, Build and Compilation

Strategy: Environment Hardening

Description:

  • Run or compile the software using features or extensions that randomly arrange the positions of a program's executable and libraries in memory. Because this makes the addresses unpredictable, it can prevent an attacker from reliably jumping to exploitable code.
  • Examples include Address Space Layout Randomization (ASLR) [REF-58] [REF-60] and Position-Independent Executables (PIE) [REF-64]. Imported modules may be similarly realigned if their default memory addresses conflict with other modules, in a process known as "rebasing" (for Windows) and "prelinking" (for Linux) [REF-1332] using randomly generated addresses. ASLR for libraries cannot be used in conjunction with prelink since it would require relocating the libraries at run-time, defeating the whole purpose of prelinking.
  • For more information on these techniques see D3-SAOR (Segment Address Offset Randomization) from D3FEND [REF-1335].

No CAPEC attack patterns related to this CWE.

Back to CWE stats page