CWE-125

Out-of-bounds Read

The product reads data past the end, or before the beginning, of the intended buffer.

CVE-2019-6731 (GCVE-0-2019-6731)

Vulnerability from cvelistv5 – Published: 2019-03-19 19:56 – Updated: 2024-08-04 20:31
VLAI
Summary
This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of Foxit PhantomPDF. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the conversion of HTML files to PDF. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated object. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-7369.
Severity
No CVSS data available.
CWE
Assigner
zdi
References
Impacted products
Vendor Product Version
Foxit PhantomPDF Affected: 9.3.0.10826
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:31:04.132Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.foxitsoftware.com/support/security-bulletins.php"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-137/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "PhantomPDF",
          "vendor": "Foxit",
          "versions": [
            {
              "status": "affected",
              "version": "9.3.0.10826"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of Foxit PhantomPDF. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the conversion of HTML files to PDF. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated object. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-7369."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-03-19T19:56:01.000Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.foxitsoftware.com/support/security-bulletins.php"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-137/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "zdi-disclosures@trendmicro.com",
          "ID": "CVE-2019-6731",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "PhantomPDF",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "9.3.0.10826"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Foxit"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of Foxit PhantomPDF. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the conversion of HTML files to PDF. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated object. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-7369."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-125: Out-of-bounds Read"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.foxitsoftware.com/support/security-bulletins.php",
              "refsource": "MISC",
              "url": "https://www.foxitsoftware.com/support/security-bulletins.php"
            },
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-19-137/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-137/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2019-6731",
    "datePublished": "2019-03-19T19:56:01.000Z",
    "dateReserved": "2019-01-24T00:00:00.000Z",
    "dateUpdated": "2024-08-04T20:31:04.132Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-6732 (GCVE-0-2019-6732)

Vulnerability from cvelistv5 – Published: 2019-03-19 19:56 – Updated: 2024-08-04 20:31
VLAI
Summary
This vulnerability allows remote attackers to disclose sensitive information on vulnerable installations of Foxit PhantomPDF. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the handling of the AFParseDateEx method. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the current process. Was ZDI-CAN-7453.
Severity
No CVSS data available.
CWE
Assigner
zdi
References
Impacted products
Vendor Product Version
Foxit PhantomPDF Affected: 9.3.0.10826
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:31:03.997Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.foxitsoftware.com/support/security-bulletins.php"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-138/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "PhantomPDF",
          "vendor": "Foxit",
          "versions": [
            {
              "status": "affected",
              "version": "9.3.0.10826"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "This vulnerability allows remote attackers to disclose sensitive information on vulnerable installations of Foxit PhantomPDF. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the handling of the AFParseDateEx method. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the current process. Was ZDI-CAN-7453."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-03-19T19:56:01.000Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.foxitsoftware.com/support/security-bulletins.php"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-138/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "zdi-disclosures@trendmicro.com",
          "ID": "CVE-2019-6732",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "PhantomPDF",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "9.3.0.10826"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Foxit"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "This vulnerability allows remote attackers to disclose sensitive information on vulnerable installations of Foxit PhantomPDF. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the handling of the AFParseDateEx method. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the current process. Was ZDI-CAN-7453."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-125: Out-of-bounds Read"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.foxitsoftware.com/support/security-bulletins.php",
              "refsource": "MISC",
              "url": "https://www.foxitsoftware.com/support/security-bulletins.php"
            },
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-19-138/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-138/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2019-6732",
    "datePublished": "2019-03-19T19:56:01.000Z",
    "dateReserved": "2019-01-24T00:00:00.000Z",
    "dateUpdated": "2024-08-04T20:31:03.997Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-6733 (GCVE-0-2019-6733)

Vulnerability from cvelistv5 – Published: 2019-03-19 19:56 – Updated: 2024-08-04 20:31
VLAI
Summary
This vulnerability allows remote attackers to disclose sensitive information on vulnerable installations of Foxit PhantomPDF. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the handling of PDF files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the current process. Was ZDI-CAN-7576.
Severity
No CVSS data available.
CWE
Assigner
zdi
References
Impacted products
Vendor Product Version
Foxit PhantomPDF Affected: 9.3.0.10826
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:31:04.027Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.foxitsoftware.com/support/security-bulletins.php"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-139/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "PhantomPDF",
          "vendor": "Foxit",
          "versions": [
            {
              "status": "affected",
              "version": "9.3.0.10826"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "This vulnerability allows remote attackers to disclose sensitive information on vulnerable installations of Foxit PhantomPDF. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the handling of PDF files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the current process. Was ZDI-CAN-7576."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-03-19T19:56:01.000Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.foxitsoftware.com/support/security-bulletins.php"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-139/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "zdi-disclosures@trendmicro.com",
          "ID": "CVE-2019-6733",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "PhantomPDF",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "9.3.0.10826"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Foxit"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "This vulnerability allows remote attackers to disclose sensitive information on vulnerable installations of Foxit PhantomPDF. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the handling of PDF files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the current process. Was ZDI-CAN-7576."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-125: Out-of-bounds Read"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.foxitsoftware.com/support/security-bulletins.php",
              "refsource": "MISC",
              "url": "https://www.foxitsoftware.com/support/security-bulletins.php"
            },
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-19-139/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-139/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2019-6733",
    "datePublished": "2019-03-19T19:56:01.000Z",
    "dateReserved": "2019-01-24T00:00:00.000Z",
    "dateUpdated": "2024-08-04T20:31:04.027Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-6735 (GCVE-0-2019-6735)

Vulnerability from cvelistv5 – Published: 2019-03-19 19:56 – Updated: 2024-08-04 20:31
VLAI
Summary
This vulnerability allows remote attackers to disclose sensitive information on vulnerable installations of Foxit Reader. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the processing of PDF files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the current process. Was ZDI-CAN-7355.
Severity
No CVSS data available.
CWE
Assigner
zdi
References
Impacted products
Vendor Product Version
Foxit Reader Affected: 9.3.0.10826
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:31:04.188Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.foxitsoftware.com/support/security-bulletins.php"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-141/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Reader",
          "vendor": "Foxit",
          "versions": [
            {
              "status": "affected",
              "version": "9.3.0.10826"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "This vulnerability allows remote attackers to disclose sensitive information on vulnerable installations of Foxit Reader. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the processing of PDF files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the current process. Was ZDI-CAN-7355."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-03-19T19:56:01.000Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.foxitsoftware.com/support/security-bulletins.php"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-141/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "zdi-disclosures@trendmicro.com",
          "ID": "CVE-2019-6735",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Reader",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "9.3.0.10826"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Foxit"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "This vulnerability allows remote attackers to disclose sensitive information on vulnerable installations of Foxit Reader. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the processing of PDF files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the current process. Was ZDI-CAN-7355."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-125: Out-of-bounds Read"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.foxitsoftware.com/support/security-bulletins.php",
              "refsource": "MISC",
              "url": "https://www.foxitsoftware.com/support/security-bulletins.php"
            },
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-19-141/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-141/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2019-6735",
    "datePublished": "2019-03-19T19:56:01.000Z",
    "dateReserved": "2019-01-24T00:00:00.000Z",
    "dateUpdated": "2024-08-04T20:31:04.188Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-6746 (GCVE-0-2019-6746)

Vulnerability from cvelistv5 – Published: 2019-06-03 18:15 – Updated: 2024-08-04 20:31
VLAI
Summary
This vulnerability allows remote attackers to disclose sensitive information on vulnerable installations of Foxit Studio Photo 3.6.6. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the handling of TIF files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the current process. Was ZDI-CAN-7634.
CWE
Assigner
zdi
References
Impacted products
Vendor Product Version
Foxit Studio Photo Affected: 3.6.6
Create a notification for this product.
Credits
Mat Powell of Trend Micro Zero Day Initiative
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:31:04.244Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.foxitsoftware.com/support/security-bulletins.php"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-370/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Studio Photo",
          "vendor": "Foxit",
          "versions": [
            {
              "status": "affected",
              "version": "3.6.6"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Mat Powell of Trend Micro Zero Day Initiative"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "This vulnerability allows remote attackers to disclose sensitive information on vulnerable installations of Foxit Studio Photo 3.6.6. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the handling of TIF files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the current process. Was ZDI-CAN-7634."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 3.3,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-06-03T18:15:01.000Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.foxitsoftware.com/support/security-bulletins.php"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-370/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "zdi-disclosures@trendmicro.com",
          "ID": "CVE-2019-6746",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Studio Photo",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "3.6.6"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Foxit"
              }
            ]
          }
        },
        "credit": "Mat Powell of Trend Micro Zero Day Initiative",
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "This vulnerability allows remote attackers to disclose sensitive information on vulnerable installations of Foxit Studio Photo 3.6.6. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the handling of TIF files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the current process. Was ZDI-CAN-7634."
            }
          ]
        },
        "impact": {
          "cvss": {
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-125: Out-of-bounds Read"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.foxitsoftware.com/support/security-bulletins.php",
              "refsource": "MISC",
              "url": "https://www.foxitsoftware.com/support/security-bulletins.php"
            },
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-19-370/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-370/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2019-6746",
    "datePublished": "2019-06-03T18:15:01.000Z",
    "dateReserved": "2019-01-24T00:00:00.000Z",
    "dateUpdated": "2024-08-04T20:31:04.244Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-6752 (GCVE-0-2019-6752)

Vulnerability from cvelistv5 – Published: 2019-06-03 18:15 – Updated: 2024-08-04 20:31
VLAI
Summary
This vulnerability allows remote attackers to disclose sensitive information on vulnerable installations of Foxit PhantomPDF 9.3.10826. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of PDF documents. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated object. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the current process. Was ZDI-CAN-7620.
CWE
Assigner
zdi
References
Impacted products
Vendor Product Version
Foxit PhantomPDF Affected: 9.3.10826
Create a notification for this product.
Credits
T3rmin4t0r
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:31:04.216Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.foxitsoftware.com/support/security-bulletins.php"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-426/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "PhantomPDF",
          "vendor": "Foxit",
          "versions": [
            {
              "status": "affected",
              "version": "9.3.10826"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "T3rmin4t0r"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "This vulnerability allows remote attackers to disclose sensitive information on vulnerable installations of Foxit PhantomPDF 9.3.10826. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of PDF documents. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated object. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the current process. Was ZDI-CAN-7620."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 3.3,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-06-03T18:15:01.000Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.foxitsoftware.com/support/security-bulletins.php"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-426/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "zdi-disclosures@trendmicro.com",
          "ID": "CVE-2019-6752",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "PhantomPDF",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "9.3.10826"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Foxit"
              }
            ]
          }
        },
        "credit": "T3rmin4t0r",
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "This vulnerability allows remote attackers to disclose sensitive information on vulnerable installations of Foxit PhantomPDF 9.3.10826. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of PDF documents. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated object. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of the current process. Was ZDI-CAN-7620."
            }
          ]
        },
        "impact": {
          "cvss": {
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-125: Out-of-bounds Read"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.foxitsoftware.com/support/security-bulletins.php",
              "refsource": "MISC",
              "url": "https://www.foxitsoftware.com/support/security-bulletins.php"
            },
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-19-426/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-426/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2019-6752",
    "datePublished": "2019-06-03T18:15:01.000Z",
    "dateReserved": "2019-01-24T00:00:00.000Z",
    "dateUpdated": "2024-08-04T20:31:04.216Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-6765 (GCVE-0-2019-6765)

Vulnerability from cvelistv5 – Published: 2019-06-03 18:15 – Updated: 2024-08-04 20:31
VLAI
Summary
This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of Foxit PhantomPDF 9.4.1.16828. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the conversion of HTML files to PDF. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated object. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-8170.
CWE
Assigner
zdi
References
Impacted products
Vendor Product Version
Foxit PhantomPDF Affected: 9.4.1.16828
Create a notification for this product.
Credits
RockStar
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:31:04.121Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.foxitsoftware.com/support/security-bulletins.php"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-439/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "PhantomPDF",
          "vendor": "Foxit",
          "versions": [
            {
              "status": "affected",
              "version": "9.4.1.16828"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "RockStar"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of Foxit PhantomPDF 9.4.1.16828. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the conversion of HTML files to PDF. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated object. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-8170."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-06-03T18:15:02.000Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.foxitsoftware.com/support/security-bulletins.php"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-439/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "zdi-disclosures@trendmicro.com",
          "ID": "CVE-2019-6765",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "PhantomPDF",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "9.4.1.16828"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Foxit"
              }
            ]
          }
        },
        "credit": "RockStar",
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of Foxit PhantomPDF 9.4.1.16828. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the conversion of HTML files to PDF. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated object. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-8170."
            }
          ]
        },
        "impact": {
          "cvss": {
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-125: Out-of-bounds Read"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.foxitsoftware.com/support/security-bulletins.php",
              "refsource": "MISC",
              "url": "https://www.foxitsoftware.com/support/security-bulletins.php"
            },
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-19-439/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-19-439/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2019-6765",
    "datePublished": "2019-06-03T18:15:02.000Z",
    "dateReserved": "2019-01-24T00:00:00.000Z",
    "dateUpdated": "2024-08-04T20:31:04.121Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-7819 (GCVE-0-2019-7819)

Vulnerability from cvelistv5 – Published: 2023-09-11 13:50 – Updated: 2024-08-04 21:02
VLAI
Title
Adobe Acrobat Pro DC PostScript File Parsing Out-Of-Bounds Read Information Disclosure Vulnerability
Summary
Adobe Acrobat Reader versions 2019.010.20098 and earlier are affected by an out-of-bounds read vulnerability that could lead to disclosure of sensitive memory. An attacker could leverage this vulnerability to bypass mitigations such as ASLR. Exploitation of this issue requires user interaction in that a victim must open a malicious file.
CWE
  • CWE-125 - Out-of-bounds Read (CWE-125)
Assigner
References
Impacted products
Vendor Product Version
Adobe Acrobat Reader Affected: 0 , ≤ 2019.010.20098 (semver)
Create a notification for this product.
Date Public
2019-05-14 17:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T21:02:18.598Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://helpx.adobe.com/security/products/acrobat/apsb19-17.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Acrobat Reader",
          "vendor": "Adobe",
          "versions": [
            {
              "lessThanOrEqual": "2019.010.20098",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2019-05-14T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Adobe Acrobat Reader versions 2019.010.20098 and earlier are affected by an out-of-bounds read vulnerability that could lead to disclosure of sensitive memory. An attacker could leverage this vulnerability to bypass mitigations such as ASLR. Exploitation of this issue requires user interaction in that a victim must open a malicious file."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "availabilityRequirement": "NOT_DEFINED",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "confidentialityRequirement": "NOT_DEFINED",
            "environmentalScore": 5.5,
            "environmentalSeverity": "MEDIUM",
            "exploitCodeMaturity": "NOT_DEFINED",
            "integrityImpact": "NONE",
            "integrityRequirement": "NOT_DEFINED",
            "modifiedAttackComplexity": "LOW",
            "modifiedAttackVector": "LOCAL",
            "modifiedAvailabilityImpact": "NONE",
            "modifiedConfidentialityImpact": "HIGH",
            "modifiedIntegrityImpact": "NONE",
            "modifiedPrivilegesRequired": "NONE",
            "modifiedScope": "NOT_DEFINED",
            "modifiedUserInteraction": "REQUIRED",
            "privilegesRequired": "NONE",
            "remediationLevel": "NOT_DEFINED",
            "reportConfidence": "NOT_DEFINED",
            "scope": "UNCHANGED",
            "temporalScore": 5.5,
            "temporalSeverity": "MEDIUM",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "Out-of-bounds Read (CWE-125)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-09-11T13:50:54.091Z",
        "orgId": "078d4453-3bcd-4900-85e6-15281da43538",
        "shortName": "adobe"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://helpx.adobe.com/security/products/acrobat/apsb19-17.html"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Adobe Acrobat Pro DC PostScript File Parsing Out-Of-Bounds Read Information Disclosure Vulnerability  "
    }
  },
  "cveMetadata": {
    "assignerOrgId": "078d4453-3bcd-4900-85e6-15281da43538",
    "assignerShortName": "adobe",
    "cveId": "CVE-2019-7819",
    "datePublished": "2023-09-11T13:50:54.091Z",
    "dateReserved": "2019-02-12T00:00:00.000Z",
    "dateUpdated": "2024-08-04T21:02:18.598Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-8260 (GCVE-0-2019-8260)

Vulnerability from cvelistv5 – Published: 2019-03-05 15:00 – Updated: 2024-09-16 20:22
VLAI
Summary
UltraVNC revision 1199 has a out-of-bounds read vulnerability in VNC client RRE decoder code, caused by multiplication overflow. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1200.
Severity
No CVSS data available.
CWE
Assigner
Impacted products
Vendor Product Version
UltraVNC UltraVNC Affected: 1.2.2.3
Create a notification for this product.
Date Public
2019-03-01 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T21:17:30.063Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-006-ultravnc-out-of-bound-read/"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "UltraVNC",
          "vendor": "UltraVNC",
          "versions": [
            {
              "status": "affected",
              "version": "1.2.2.3"
            }
          ]
        }
      ],
      "datePublic": "2019-03-01T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "UltraVNC revision 1199 has a out-of-bounds read vulnerability in VNC client RRE decoder code, caused by multiplication overflow. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1200."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-06-28T12:04:41.000Z",
        "orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
        "shortName": "Kaspersky"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-006-ultravnc-out-of-bound-read/"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vulnerability@kaspersky.com",
          "DATE_PUBLIC": "2019-03-01T00:00:00",
          "ID": "CVE-2019-8260",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "UltraVNC",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "1.2.2.3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "UltraVNC"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "UltraVNC revision 1199 has a out-of-bounds read vulnerability in VNC client RRE decoder code, caused by multiplication overflow. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1200."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-125: Out-of-bounds Read"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-006-ultravnc-out-of-bound-read/",
              "refsource": "MISC",
              "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-006-ultravnc-out-of-bound-read/"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
            },
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
            },
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
    "assignerShortName": "Kaspersky",
    "cveId": "CVE-2019-8260",
    "datePublished": "2019-03-05T15:00:00.000Z",
    "dateReserved": "2019-02-12T00:00:00.000Z",
    "dateUpdated": "2024-09-16T20:22:40.235Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-8261 (GCVE-0-2019-8261)

Vulnerability from cvelistv5 – Published: 2019-03-05 15:00 – Updated: 2024-09-17 03:12
VLAI
Summary
UltraVNC revision 1199 has a out-of-bounds read vulnerability in VNC code inside client CoRRE decoder, caused by multiplication overflow. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1200.
Severity
No CVSS data available.
CWE
Assigner
Impacted products
Vendor Product Version
UltraVNC UltraVNC Affected: 1.2.2.3
Create a notification for this product.
Date Public
2019-03-01 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T21:17:30.573Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-007-ultravnc-out-of-bound-read/"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "UltraVNC",
          "vendor": "UltraVNC",
          "versions": [
            {
              "status": "affected",
              "version": "1.2.2.3"
            }
          ]
        }
      ],
      "datePublic": "2019-03-01T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "UltraVNC revision 1199 has a out-of-bounds read vulnerability in VNC code inside client CoRRE decoder, caused by multiplication overflow. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1200."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-06-28T12:00:18.000Z",
        "orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
        "shortName": "Kaspersky"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-007-ultravnc-out-of-bound-read/"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vulnerability@kaspersky.com",
          "DATE_PUBLIC": "2019-03-01T00:00:00",
          "ID": "CVE-2019-8261",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "UltraVNC",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "1.2.2.3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "UltraVNC"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "UltraVNC revision 1199 has a out-of-bounds read vulnerability in VNC code inside client CoRRE decoder, caused by multiplication overflow. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1200."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-125: Out-of-bounds Read"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-007-ultravnc-out-of-bound-read/",
              "refsource": "MISC",
              "url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-007-ultravnc-out-of-bound-read/"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
            },
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-940818.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
            },
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
    "assignerShortName": "Kaspersky",
    "cveId": "CVE-2019-8261",
    "datePublished": "2019-03-05T15:00:00.000Z",
    "dateReserved": "2019-02-12T00:00:00.000Z",
    "dateUpdated": "2024-09-17T03:12:34.003Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation ID: MIT-5

Phase: Implementation

Strategy: Input Validation

Description:

  • Assume all input is malicious. Use an "accept known good" input validation strategy, i.e., use a list of acceptable inputs that strictly conform to specifications. Reject any input that does not strictly conform to specifications, or transform it into something that does.
  • When performing input validation, consider all potentially relevant properties, including length, type of input, the full range of acceptable values, missing or extra inputs, syntax, consistency across related fields, and conformance to business rules. As an example of business rule logic, "boat" may be syntactically valid because it only contains alphanumeric characters, but it is not valid if the input is only expected to contain colors such as "red" or "blue."
  • Do not rely exclusively on looking for malicious or malformed inputs. This is likely to miss at least one undesirable input, especially if the code's environment changes. This can give attackers enough room to bypass the intended validation. However, denylists can be useful for detecting potential attacks or determining which inputs are so malformed that they should be rejected outright.
  • To reduce the likelihood of introducing an out-of-bounds read, ensure that you validate and ensure correct calculations for any length argument, buffer size calculation, or offset. Be especially careful of relying on a sentinel (i.e. special character such as NUL) in untrusted inputs.
Mitigation

Phase: Architecture and Design

Strategy: Language Selection

Description:

  • Use a language that provides appropriate memory abstractions.
CAPEC-540: Overread Buffers

An adversary attacks a target by providing input that causes an application to read beyond the boundary of a defined buffer. This typically occurs when a value influencing where to start or stop reading is set to reflect positions outside of the valid memory location of the buffer. This type of attack may result in exposure of sensitive information, a system crash, or arbitrary code execution.

Back to CWE stats page