CWE-125
Out-of-bounds Read
The product reads data past the end, or before the beginning, of the intended buffer.
CVE-2021-27266 (GCVE-0-2021-27266)
Vulnerability from cvelistv5 – Published: 2021-03-30 14:35 – Updated: 2024-08-03 20:48
VLAI
Summary
This vulnerability allows remote attackers to disclose sensitive information on affected installations of Foxit PhantomPDF 10.1.0.37527. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the handling of U3D objects embedded in PDF files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated object. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process. Was ZDI-CAN-12293.
Severity
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.foxitsoftware.com/support/security-bu… | x_refsource_MISC |
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Foxit | PhantomPDF |
Affected:
10.1.0.37527
|
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T20:48:15.880Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.foxitsoftware.com/support/security-bulletins.php"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-348/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "PhantomPDF",
"vendor": "Foxit",
"versions": [
{
"status": "affected",
"version": "10.1.0.37527"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Mat Powell of Trend Micro Zero Day Initiative"
}
],
"descriptions": [
{
"lang": "en",
"value": "This vulnerability allows remote attackers to disclose sensitive information on affected installations of Foxit PhantomPDF 10.1.0.37527. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the handling of U3D objects embedded in PDF files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated object. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process. Was ZDI-CAN-12293."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.3,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-03-30T14:35:35.000Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.foxitsoftware.com/support/security-bulletins.php"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-348/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"ID": "CVE-2021-27266",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PhantomPDF",
"version": {
"version_data": [
{
"version_value": "10.1.0.37527"
}
]
}
}
]
},
"vendor_name": "Foxit"
}
]
}
},
"credit": "Mat Powell of Trend Micro Zero Day Initiative",
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "This vulnerability allows remote attackers to disclose sensitive information on affected installations of Foxit PhantomPDF 10.1.0.37527. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the handling of U3D objects embedded in PDF files. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated object. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process. Was ZDI-CAN-12293."
}
]
},
"impact": {
"cvss": {
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-125: Out-of-bounds Read"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.foxitsoftware.com/support/security-bulletins.php",
"refsource": "MISC",
"url": "https://www.foxitsoftware.com/support/security-bulletins.php"
},
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-21-348/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-348/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2021-27266",
"datePublished": "2021-03-30T14:35:35.000Z",
"dateReserved": "2021-02-16T00:00:00.000Z",
"dateUpdated": "2024-08-03T20:48:15.880Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-27270 (GCVE-0-2021-27270)
Vulnerability from cvelistv5 – Published: 2021-03-30 14:35 – Updated: 2024-08-03 20:48
VLAI
Summary
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Foxit PhantomPDF 10.1.0.37527. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of JPEG2000 images. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-12230.
Severity
7.8 (High)
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.foxitsoftware.com/support/security-bu… | x_refsource_MISC |
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Foxit | PhantomPDF |
Affected:
10.1.0.37527
|
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T20:48:15.987Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.foxitsoftware.com/support/security-bulletins.php"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-352/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "PhantomPDF",
"vendor": "Foxit",
"versions": [
{
"status": "affected",
"version": "10.1.0.37527"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "cece"
}
],
"descriptions": [
{
"lang": "en",
"value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Foxit PhantomPDF 10.1.0.37527. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of JPEG2000 images. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-12230."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-03-30T14:35:37.000Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.foxitsoftware.com/support/security-bulletins.php"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-352/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"ID": "CVE-2021-27270",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PhantomPDF",
"version": {
"version_data": [
{
"version_value": "10.1.0.37527"
}
]
}
}
]
},
"vendor_name": "Foxit"
}
]
}
},
"credit": "cece",
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Foxit PhantomPDF 10.1.0.37527. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of JPEG2000 images. The issue results from the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-12230."
}
]
},
"impact": {
"cvss": {
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-125: Out-of-bounds Read"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.foxitsoftware.com/support/security-bulletins.php",
"refsource": "MISC",
"url": "https://www.foxitsoftware.com/support/security-bulletins.php"
},
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-21-352/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-352/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2021-27270",
"datePublished": "2021-03-30T14:35:37.000Z",
"dateReserved": "2021-02-16T00:00:00.000Z",
"dateUpdated": "2024-08-03T20:48:15.987Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-27271 (GCVE-0-2021-27271)
Vulnerability from cvelistv5 – Published: 2021-03-30 14:35 – Updated: 2024-08-03 20:48
VLAI
Summary
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Foxit PhantomPDF 10.1.0.37527. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the handling of U3D objects embedded in PDF files. The issue results from the lack of proper validation of user-supplied data, which can result in an out-of-bounds read condition. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-12438.
Severity
7.8 (High)
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.foxitsoftware.com/support/security-bu… | x_refsource_MISC |
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Foxit | PhantomPDF |
Affected:
10.1.0.37527
|
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T20:48:16.025Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.foxitsoftware.com/support/security-bulletins.php"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-353/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "PhantomPDF",
"vendor": "Foxit",
"versions": [
{
"status": "affected",
"version": "10.1.0.37527"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Mat Powell of Trend Micro Zero Day Initiative"
}
],
"descriptions": [
{
"lang": "en",
"value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Foxit PhantomPDF 10.1.0.37527. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the handling of U3D objects embedded in PDF files. The issue results from the lack of proper validation of user-supplied data, which can result in an out-of-bounds read condition. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-12438."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-09-26T21:30:15.000Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.foxitsoftware.com/support/security-bulletins.php"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-353/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"ID": "CVE-2021-27271",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PhantomPDF",
"version": {
"version_data": [
{
"version_value": "10.1.0.37527"
}
]
}
}
]
},
"vendor_name": "Foxit"
}
]
}
},
"credit": "Mat Powell of Trend Micro Zero Day Initiative",
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Foxit PhantomPDF 10.1.0.37527. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the handling of U3D objects embedded in PDF files. The issue results from the lack of proper validation of user-supplied data, which can result in an out-of-bounds read condition. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-12438."
}
]
},
"impact": {
"cvss": {
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-125: Out-of-bounds Read"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.foxitsoftware.com/support/security-bulletins.php",
"refsource": "MISC",
"url": "https://www.foxitsoftware.com/support/security-bulletins.php"
},
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-21-353/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-353/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2021-27271",
"datePublished": "2021-03-30T14:35:38.000Z",
"dateReserved": "2021-02-16T00:00:00.000Z",
"dateUpdated": "2024-08-03T20:48:16.025Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-27381 (GCVE-0-2021-27381)
Vulnerability from cvelistv5 – Published: 2021-03-15 17:03 – Updated: 2024-08-03 20:48
VLAI
Summary
A vulnerability has been identified in Solid Edge SE2020 (All Versions < SE2020MP13), Solid Edge SE2021 (All Versions < SE2021MP3). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12534)
Severity
No CVSS data available.
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Solid Edge SE2020 |
Affected:
All Versions < SE2020MP13
|
|
| Siemens | Solid Edge SE2021 |
Affected:
All Versions < SE2021MP3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T20:48:16.358Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Solid Edge SE2020",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c SE2020MP13"
}
]
},
{
"product": "Solid Edge SE2021",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c SE2021MP3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP3). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12534)"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-04-22T20:42:21.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-27381",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Solid Edge SE2020",
"version": {
"version_data": [
{
"version_value": "All Versions \u003c SE2020MP13"
}
]
}
},
{
"product_name": "Solid Edge SE2021",
"version": {
"version_data": [
{
"version_value": "All Versions \u003c SE2021MP3"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP3). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12534)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-125: Out-of-bounds Read"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-27381",
"datePublished": "2021-03-15T17:03:31.000Z",
"dateReserved": "2021-02-18T00:00:00.000Z",
"dateUpdated": "2024-08-03T20:48:16.358Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-27408 (GCVE-0-2021-27408)
Vulnerability from cvelistv5 – Published: 2021-06-11 16:31 – Updated: 2024-08-03 20:48
VLAI
Summary
The affected product is vulnerable to an out-of-bounds read, which can cause information leakage leading to arbitrary code execution if chained to the out-of-bounds write vulnerability on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite – Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00).
Severity
No CVSS data available.
CWE
- CWE-125 - OUT-OF-BOUNDS READ CWE-125
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsma-21-152-01 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Welch Allyn medical device management tools |
Affected:
Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite – Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T20:48:16.852Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-21-152-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Welch Allyn medical device management tools",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite \u2013 Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The affected product is vulnerable to an out-of-bounds read, which can cause information leakage leading to arbitrary code execution if chained to the out-of-bounds write vulnerability on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite \u2013 Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00)."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "OUT-OF-BOUNDS READ CWE-125",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-06-11T16:31:58.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-21-152-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2021-27408",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Welch Allyn medical device management tools",
"version": {
"version_data": [
{
"version_value": "Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite \u2013 Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The affected product is vulnerable to an out-of-bounds read, which can cause information leakage leading to arbitrary code execution if chained to the out-of-bounds write vulnerability on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite \u2013 Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "OUT-OF-BOUNDS READ CWE-125"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsma-21-152-01",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-21-152-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-27408",
"datePublished": "2021-06-11T16:31:58.000Z",
"dateReserved": "2021-02-19T00:00:00.000Z",
"dateUpdated": "2024-08-03T20:48:16.852Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-27412 (GCVE-0-2021-27412)
Vulnerability from cvelistv5 – Published: 2021-07-02 10:52 – Updated: 2024-08-03 20:48
VLAI
Summary
Delta Electronics DOPSoft Versions 4.0.10.17 and prior are vulnerable to an out-of-bounds read, which may allow an attacker to execute arbitrary code.
Severity
No CVSS data available.
CWE
- CWE-125 - OUT-OF-BOUNDS READ CWE-125
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsa-21-182-03 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Delta Electronics DOPSoft |
Affected:
DOPSoft Version 4.0.10.17 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T20:48:16.918Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-182-03"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Delta Electronics DOPSoft",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "DOPSoft Version 4.0.10.17 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Delta Electronics DOPSoft Versions 4.0.10.17 and prior are vulnerable to an out-of-bounds read, which may allow an attacker to execute arbitrary code."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "OUT-OF-BOUNDS READ CWE-125",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-07-02T10:52:04.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-182-03"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2021-27412",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Delta Electronics DOPSoft",
"version": {
"version_data": [
{
"version_value": "DOPSoft Version 4.0.10.17 and prior"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Delta Electronics DOPSoft Versions 4.0.10.17 and prior are vulnerable to an out-of-bounds read, which may allow an attacker to execute arbitrary code."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "OUT-OF-BOUNDS READ CWE-125"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-182-03",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-182-03"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-27412",
"datePublished": "2021-07-02T10:52:04.000Z",
"dateReserved": "2021-02-19T00:00:00.000Z",
"dateUpdated": "2024-08-03T20:48:16.918Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-27455 (GCVE-0-2021-27455)
Vulnerability from cvelistv5 – Published: 2021-07-02 10:51 – Updated: 2024-08-03 20:48
VLAI
Summary
Delta Electronics DOPSoft Versions 4.0.10.17 and prior are vulnerable to an out-of-bounds read while processing project files, which may allow an attacker to disclose information.
Severity
No CVSS data available.
CWE
- CWE-125 - OUT-OF-BOUNDS READ CWE-125
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsa-21-182-03 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Delta Electronics DOPSoft |
Affected:
DOPSoft Version 4.0.10.17 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T20:48:17.283Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-182-03"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Delta Electronics DOPSoft",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "DOPSoft Version 4.0.10.17 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Delta Electronics DOPSoft Versions 4.0.10.17 and prior are vulnerable to an out-of-bounds read while processing project files, which may allow an attacker to disclose information."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "OUT-OF-BOUNDS READ CWE-125",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-07-02T10:51:57.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-182-03"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2021-27455",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Delta Electronics DOPSoft",
"version": {
"version_data": [
{
"version_value": "DOPSoft Version 4.0.10.17 and prior"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Delta Electronics DOPSoft Versions 4.0.10.17 and prior are vulnerable to an out-of-bounds read while processing project files, which may allow an attacker to disclose information."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "OUT-OF-BOUNDS READ CWE-125"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-182-03",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-182-03"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-27455",
"datePublished": "2021-07-02T10:51:57.000Z",
"dateReserved": "2021-02-19T00:00:00.000Z",
"dateUpdated": "2024-08-03T20:48:17.283Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-27482 (GCVE-0-2021-27482)
Vulnerability from cvelistv5 – Published: 2022-05-12 19:18 – Updated: 2025-04-16 16:22
VLAI
Title
EIPStackGroup OpENer Ethernet/IP Out-of-bounds Read
Summary
A specifically crafted packet sent by an attacker to EIPStackGroup OpENer EtherNet/IP commits and versions prior to Feb 10, 2021 may allow the attacker to read arbitrary data.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.cisa.gov/uscert/ics/advisories/icsa-2… | x_refsource_CONFIRM |
| https://github.com/EIPStackGroup/OpENer | x_refsource_CONFIRM |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| EIPStackGroup | OpENer EtherNet/IP |
Affected:
unspecified , < Feb 10, 2021
(custom)
|
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T20:48:17.255Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-105-02"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://github.com/EIPStackGroup/OpENer"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-27482",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T15:56:25.495662Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T16:22:25.057Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "OpENer EtherNet/IP",
"vendor": "EIPStackGroup",
"versions": [
{
"lessThan": "Feb 10, 2021",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Tal Keren and Sharon Brizinov of Claroty reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"value": "A specifically crafted packet sent by an attacker to EIPStackGroup OpENer EtherNet/IP commits and versions prior to Feb 10, 2021 may allow the attacker to read arbitrary data."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-12T19:18:03.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-105-02"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://github.com/EIPStackGroup/OpENer"
}
],
"solutions": [
{
"lang": "en",
"value": "The maintainer of OpENer recommends those affected to apply the latest commits available."
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "EIPStackGroup OpENer Ethernet/IP Out-of-bounds Read",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2021-27482",
"STATE": "PUBLIC",
"TITLE": "EIPStackGroup OpENer Ethernet/IP Out-of-bounds Read"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "OpENer EtherNet/IP",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "Feb 10, 2021"
}
]
}
}
]
},
"vendor_name": "EIPStackGroup"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Tal Keren and Sharon Brizinov of Claroty reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A specifically crafted packet sent by an attacker to EIPStackGroup OpENer EtherNet/IP commits and versions prior to Feb 10, 2021 may allow the attacker to read arbitrary data."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-125: Out-of-bounds Read"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-105-02",
"refsource": "CONFIRM",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-105-02"
},
{
"name": "https://github.com/EIPStackGroup/OpENer",
"refsource": "CONFIRM",
"url": "https://github.com/EIPStackGroup/OpENer"
}
]
},
"solution": [
{
"lang": "en",
"value": "The maintainer of OpENer recommends those affected to apply the latest commits available."
}
],
"source": {
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-27482",
"datePublished": "2022-05-12T19:18:03.000Z",
"dateReserved": "2021-02-19T00:00:00.000Z",
"dateUpdated": "2025-04-16T16:22:25.057Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-27490 (GCVE-0-2021-27490)
Vulnerability from cvelistv5 – Published: 2021-05-27 16:08 – Updated: 2024-08-03 21:26
VLAI
Summary
Datakit Software libraries CatiaV5_3dRead, CatiaV6_3dRead, Step3dRead, Ug3dReadPsr, Jt3dReadPsr modules in KeyShot Versions v10.1 and prior are vulnerable to an out-of-bounds read, which may allow an attacker to execute arbitrary code.
Severity
No CVSS data available.
CWE
- CWE-125 - OUT-OF-BOUNDS READ CWE-125
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_refsource_MISC |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://us-cert.cisa.gov/ics/advisories/icsa-21-145-01 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Datakit Software libraries embedded in Luxion KeyShot software |
Affected:
CatiaV5_3dRead, CatiaV6_3dRead, Step3dRead, Ug3dReadPsr, Jt3dReadPsr modules in KeyShot Versions v10.1 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T21:26:08.971Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-566/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-119468.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-145-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Datakit Software libraries embedded in Luxion KeyShot software",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "CatiaV5_3dRead, CatiaV6_3dRead, Step3dRead, Ug3dReadPsr, Jt3dReadPsr modules in KeyShot Versions v10.1 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Datakit Software libraries CatiaV5_3dRead, CatiaV6_3dRead, Step3dRead, Ug3dReadPsr, Jt3dReadPsr modules in KeyShot Versions v10.1 and prior are vulnerable to an out-of-bounds read, which may allow an attacker to execute arbitrary code."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "OUT-OF-BOUNDS READ CWE-125",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-05-27T16:08:49.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-566/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-119468.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-145-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2021-27490",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Datakit Software libraries embedded in Luxion KeyShot software",
"version": {
"version_data": [
{
"version_value": "CatiaV5_3dRead, CatiaV6_3dRead, Step3dRead, Ug3dReadPsr, Jt3dReadPsr modules in KeyShot Versions v10.1 and prior"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Datakit Software libraries CatiaV5_3dRead, CatiaV6_3dRead, Step3dRead, Ug3dReadPsr, Jt3dReadPsr modules in KeyShot Versions v10.1 and prior are vulnerable to an out-of-bounds read, which may allow an attacker to execute arbitrary code."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "OUT-OF-BOUNDS READ CWE-125"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-21-566/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-566/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-119468.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-119468.pdf"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-145-01",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-145-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-27490",
"datePublished": "2021-05-27T16:08:18.000Z",
"dateReserved": "2021-02-19T00:00:00.000Z",
"dateUpdated": "2024-08-03T21:26:08.971Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-27597 (GCVE-0-2021-27597)
Vulnerability from cvelistv5 – Published: 2021-06-09 00:00 – Updated: 2024-08-03 21:26
VLAI
Summary
SAP NetWeaver AS for ABAP (RFC Gateway), versions - KRNL32NUC - 7.22,7.22EXT, KRNL64NUC - 7.22,7.22EXT,7.49, KRNL64UC - 8.04,7.22,7.22EXT,7.49,7.53,7.73, KERNEL - 7.22,8.04,7.49,7.53,7.73,7.77,7.81,7.82,7.83, allows an unauthenticated attacker without specific knowledge of the system to send a specially crafted packet over a network which will trigger an internal error in the system due to improper input validation in method memmove() causing the system to crash and rendering it unavailable. In this attack, no data in the system can be viewed or modified.
Severity
7.5 (High)
CWE
- CWE-125 - Improper Input Validation (CWE-125)
Assigner
References
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| SAP SE | SAP NetWeaver AS for ABAP (RFC Gateway) |
Affected:
< KRNL32NUC - 7.22
Affected: < 7.22EXT Affected: < KRNL64NUC - 7.22 Affected: < 7.49 Affected: < KRNL64UC - 8.04 Affected: < 7.22 Affected: < 7.53 Affected: < 7.73 Affected: < KERNEL - 7.22 Affected: < 8.04 Affected: < 7.77 Affected: < 7.81 Affected: < 7.82 Affected: < 7.83 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T21:26:09.711Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://wiki.scn.sap.com/wiki/pages/viewpage.action?pageId=578125999"
},
{
"tags": [
"x_transferred"
],
"url": "https://launchpad.support.sap.com/#/notes/3020209"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SAP NetWeaver AS for ABAP (RFC Gateway)",
"vendor": "SAP SE",
"versions": [
{
"status": "affected",
"version": "\u003c KRNL32NUC - 7.22"
},
{
"status": "affected",
"version": "\u003c 7.22EXT"
},
{
"status": "affected",
"version": "\u003c KRNL64NUC - 7.22"
},
{
"status": "affected",
"version": "\u003c 7.49"
},
{
"status": "affected",
"version": "\u003c KRNL64UC - 8.04"
},
{
"status": "affected",
"version": "\u003c 7.22"
},
{
"status": "affected",
"version": "\u003c 7.53"
},
{
"status": "affected",
"version": "\u003c 7.73"
},
{
"status": "affected",
"version": "\u003c KERNEL - 7.22"
},
{
"status": "affected",
"version": "\u003c 8.04"
},
{
"status": "affected",
"version": "\u003c 7.77"
},
{
"status": "affected",
"version": "\u003c 7.81"
},
{
"status": "affected",
"version": "\u003c 7.82"
},
{
"status": "affected",
"version": "\u003c 7.83"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "SAP NetWeaver AS for ABAP (RFC Gateway), versions - KRNL32NUC - 7.22,7.22EXT, KRNL64NUC - 7.22,7.22EXT,7.49, KRNL64UC - 8.04,7.22,7.22EXT,7.49,7.53,7.73, KERNEL - 7.22,8.04,7.49,7.53,7.73,7.77,7.81,7.82,7.83, allows an unauthenticated attacker without specific knowledge of the system to send a specially crafted packet over a network which will trigger an internal error in the system due to improper input validation in method memmove() causing the system to crash and rendering it unavailable. In this attack, no data in the system can be viewed or modified."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "Improper Input Validation (CWE-125)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-10-17T00:00:00.000Z",
"orgId": "e4686d1a-f260-4930-ac4c-2f5c992778dd",
"shortName": "sap"
},
"references": [
{
"url": "https://wiki.scn.sap.com/wiki/pages/viewpage.action?pageId=578125999"
},
{
"url": "https://launchpad.support.sap.com/#/notes/3020209"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "e4686d1a-f260-4930-ac4c-2f5c992778dd",
"assignerShortName": "sap",
"cveId": "CVE-2021-27597",
"datePublished": "2021-06-09T00:00:00.000Z",
"dateReserved": "2021-02-23T00:00:00.000Z",
"dateUpdated": "2024-08-03T21:26:09.711Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Mitigation ID: MIT-5
Phase: Implementation
Strategy: Input Validation
Description:
- Assume all input is malicious. Use an "accept known good" input validation strategy, i.e., use a list of acceptable inputs that strictly conform to specifications. Reject any input that does not strictly conform to specifications, or transform it into something that does.
- When performing input validation, consider all potentially relevant properties, including length, type of input, the full range of acceptable values, missing or extra inputs, syntax, consistency across related fields, and conformance to business rules. As an example of business rule logic, "boat" may be syntactically valid because it only contains alphanumeric characters, but it is not valid if the input is only expected to contain colors such as "red" or "blue."
- Do not rely exclusively on looking for malicious or malformed inputs. This is likely to miss at least one undesirable input, especially if the code's environment changes. This can give attackers enough room to bypass the intended validation. However, denylists can be useful for detecting potential attacks or determining which inputs are so malformed that they should be rejected outright.
- To reduce the likelihood of introducing an out-of-bounds read, ensure that you validate and ensure correct calculations for any length argument, buffer size calculation, or offset. Be especially careful of relying on a sentinel (i.e. special character such as NUL) in untrusted inputs.
Mitigation
Phase: Architecture and Design
Strategy: Language Selection
Description:
- Use a language that provides appropriate memory abstractions.
CAPEC-540: Overread Buffers
An adversary attacks a target by providing input that causes an application to read beyond the boundary of a defined buffer. This typically occurs when a value influencing where to start or stop reading is set to reflect positions outside of the valid memory location of the buffer. This type of attack may result in exposure of sensitive information, a system crash, or arbitrary code execution.