CWE-326
Inadequate Encryption Strength
The product stores or transmits sensitive data using an encryption scheme that is theoretically sound, but is not strong enough for the level of protection required.
CVE-2020-7565 (GCVE-0-2020-7565)
Vulnerability from cvelistv5 – Published: 2020-11-19 21:10 – Updated: 2024-08-04 09:33- CWE-326 - Inadequate Encryption Strength
| URL | Tags |
|---|---|
| https://www.se.com/ww/en/download/document/SEVD-2… | x_refsource_MISC |
| https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Modicon M221, all references, all versions |
Affected:
Modicon M221, all references, all versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:19.843Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M221, all references, all versions",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon M221, all references, all versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-326: Inadequate Encryption Strength vulnerability exists in Modicon M221 (all references, all versions) that could allow the attacker to break the encryption key when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-326",
"description": "CWE-326: Inadequate Encryption Strength",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-11T20:30:55.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-7565",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M221, all references, all versions",
"version": {
"version_data": [
{
"version_value": "Modicon M221, all references, all versions"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-326: Inadequate Encryption Strength vulnerability exists in Modicon M221 (all references, all versions) that could allow the attacker to break the encryption key when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-326: Inadequate Encryption Strength"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-04"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2020-7565",
"datePublished": "2020-11-19T21:10:09.000Z",
"dateReserved": "2020-01-21T00:00:00.000Z",
"dateUpdated": "2024-08-04T09:33:19.843Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20406 (GCVE-0-2021-20406)
Vulnerability from cvelistv5 – Published: 2021-02-12 16:35 – Updated: 2024-09-16 20:07- CWE-326 - Inadequate Encryption Strength
| URL | Tags |
|---|---|
| https://www.ibm.com/support/pages/node/6414763 | x_refsource_CONFIRM |
| https://exchange.xforce.ibmcloud.com/vulnerabilit… | vdb-entryx_refsource_XF |
| Vendor | Product | Version | |
|---|---|---|---|
| IBM | Security Verify Information Queue |
Affected:
1.0.6
Affected: 1.0.7 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:37:24.338Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.ibm.com/support/pages/node/6414763"
},
{
"name": "ibm-sviq-cve202120406-info-disc (196184)",
"tags": [
"vdb-entry",
"x_refsource_XF",
"x_transferred"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/196184"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Security Verify Information Queue",
"vendor": "IBM",
"versions": [
{
"status": "affected",
"version": "1.0.6"
},
{
"status": "affected",
"version": "1.0.7"
}
]
}
],
"datePublic": "2021-02-11T05:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eIBM Security Verify Information Queue 1.0.6 and 1.0.7 uses weaker than expected cryptographic algorithms that could allow an attacker to decrypt highly sensitive information. IBM X-Force ID: 196184.\u003c/p\u003e"
}
],
"value": "IBM Security Verify Information Queue 1.0.6 and 1.0.7 uses weaker than expected cryptographic algorithms that could allow an attacker to decrypt highly sensitive information. IBM X-Force ID: 196184."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 2.2,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"exploitCodeMaturity": "UNPROVEN",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"remediationLevel": "OFFICIAL_FIX",
"reportConfidence": "CONFIRMED",
"scope": "UNCHANGED",
"temporalScore": 2,
"temporalSeverity": "LOW",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-326",
"description": "CWE-326 Inadequate Encryption Strength",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-05-11T21:19:09.461Z",
"orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"shortName": "ibm"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.ibm.com/support/pages/node/6414763"
},
{
"name": "ibm-sviq-cve202120406-info-disc (196184)",
"tags": [
"vdb-entry",
"x_refsource_XF"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/196184"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "IBM Security Verify Information Queue information disclosure",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@us.ibm.com",
"DATE_PUBLIC": "2021-02-11T00:00:00",
"ID": "CVE-2021-20406",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Security Verify Information Queue",
"version": {
"version_data": [
{
"version_value": "1.0.6"
},
{
"version_value": "1.0.7"
}
]
}
}
]
},
"vendor_name": "IBM"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "IBM Security Verify Information Queue 1.0.6 and 1.0.7 uses weaker than expected cryptographic algorithms that could allow an attacker to decrypt highly sensitive information. IBM X-Force ID: 198184."
}
]
},
"impact": {
"cvssv3": {
"BM": {
"A": "N",
"AC": "H",
"AV": "N",
"C": "L",
"I": "N",
"PR": "H",
"S": "U",
"UI": "N"
},
"TM": {
"E": "U",
"RC": "C",
"RL": "O"
}
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Obtain Information"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.ibm.com/support/pages/node/6414763",
"refsource": "CONFIRM",
"title": "IBM Security Bulletin 6414763 (Security Verify Information Queue)",
"url": "https://www.ibm.com/support/pages/node/6414763"
},
{
"name": "ibm-sviq-cve202120406-info-disc (196184)",
"refsource": "XF",
"title": "X-Force Vulnerability Report",
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/196184"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"assignerShortName": "ibm",
"cveId": "CVE-2021-20406",
"datePublished": "2021-02-12T16:35:27.889Z",
"dateReserved": "2020-12-17T00:00:00.000Z",
"dateUpdated": "2024-09-16T20:07:44.180Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-21387 (GCVE-0-2021-21387)
Vulnerability from cvelistv5 – Published: 2021-03-19 15:25 – Updated: 2024-08-03 18:09| URL | Tags |
|---|---|
| https://github.com/parabirb/wrongthink/security/a… | x_refsource_CONFIRM |
| Vendor | Product | Version | |
|---|---|---|---|
| parabirb | wrongthink |
Affected:
>= 2.0.0, < 2.2.0
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:09:15.979Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://github.com/parabirb/wrongthink/security/advisories/GHSA-5jxh-6378-rg7v"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "wrongthink",
"vendor": "parabirb",
"versions": [
{
"status": "affected",
"version": "\u003e= 2.0.0, \u003c 2.2.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Wrongthink peer-to-peer, end-to-end encrypted messenger with PeerJS and Axolotl ratchet. In wrongthink from version 2.0.0 and before 2.3.0 there was a set of vulnerabilities causing inadequate encryption strength. Part of the secret identity key was disclosed by the fingerprint used for connection. Additionally, the safety number was improperly calculated. It was computed using part of one of the public identity keys instead of being derived from both public identity keys. This caused issues in computing safety numbers which would potentially be exploitable in the real world. Additionally there was inadequate encryption strength due to use of 1024-bit DSA keys. These issues are all fixed in version 2.3.0."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319: Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-326",
"description": "CWE-326: Inadequate Encryption Strength",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-358",
"description": "CWE-358: Improperly Implemented Security Check for Standard",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-03-19T15:25:12.000Z",
"orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
"shortName": "GitHub_M"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://github.com/parabirb/wrongthink/security/advisories/GHSA-5jxh-6378-rg7v"
}
],
"source": {
"advisory": "GHSA-5jxh-6378-rg7v",
"discovery": "UNKNOWN"
},
"title": "Partial secret key disclosure, improper safety number calculation, \u0026 inadequate encryption strength",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security-advisories@github.com",
"ID": "CVE-2021-21387",
"STATE": "PUBLIC",
"TITLE": "Partial secret key disclosure, improper safety number calculation, \u0026 inadequate encryption strength"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "wrongthink",
"version": {
"version_data": [
{
"version_value": "\u003e= 2.0.0, \u003c 2.2.0"
}
]
}
}
]
},
"vendor_name": "parabirb"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Wrongthink peer-to-peer, end-to-end encrypted messenger with PeerJS and Axolotl ratchet. In wrongthink from version 2.0.0 and before 2.3.0 there was a set of vulnerabilities causing inadequate encryption strength. Part of the secret identity key was disclosed by the fingerprint used for connection. Additionally, the safety number was improperly calculated. It was computed using part of one of the public identity keys instead of being derived from both public identity keys. This caused issues in computing safety numbers which would potentially be exploitable in the real world. Additionally there was inadequate encryption strength due to use of 1024-bit DSA keys. These issues are all fixed in version 2.3.0."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-319: Cleartext Transmission of Sensitive Information"
}
]
},
{
"description": [
{
"lang": "eng",
"value": "CWE-326: Inadequate Encryption Strength"
}
]
},
{
"description": [
{
"lang": "eng",
"value": "CWE-358: Improperly Implemented Security Check for Standard"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://github.com/parabirb/wrongthink/security/advisories/GHSA-5jxh-6378-rg7v",
"refsource": "CONFIRM",
"url": "https://github.com/parabirb/wrongthink/security/advisories/GHSA-5jxh-6378-rg7v"
}
]
},
"source": {
"advisory": "GHSA-5jxh-6378-rg7v",
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
"assignerShortName": "GitHub_M",
"cveId": "CVE-2021-21387",
"datePublished": "2021-03-19T15:25:12.000Z",
"dateReserved": "2020-12-22T00:00:00.000Z",
"dateUpdated": "2024-08-03T18:09:15.979Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-27450 (GCVE-0-2021-27450)
Vulnerability from cvelistv5 – Published: 2021-03-25 19:30 – Updated: 2024-08-03 20:48- CWE-326 - INADEQUATE ENCRYPTION STRENGTH CWE-326
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsa-21-082-02 | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T20:48:17.146Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-082-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "MU320E",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "All firmware versions prior to v04A00.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "SSH server configuration file does not implement some best practices. This could lead to a weakening of the SSH protocol strength, which could lead to additional misconfiguration or be leveraged as part of a larger attack on the MU320E (all firmware versions prior to v04A00.1)."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-326",
"description": "INADEQUATE ENCRYPTION STRENGTH CWE-326",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-03-25T19:30:27.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-082-02"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2021-27450",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "MU320E",
"version": {
"version_data": [
{
"version_value": "All firmware versions prior to v04A00.1"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "SSH server configuration file does not implement some best practices. This could lead to a weakening of the SSH protocol strength, which could lead to additional misconfiguration or be leveraged as part of a larger attack on the MU320E (all firmware versions prior to v04A00.1)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "INADEQUATE ENCRYPTION STRENGTH CWE-326"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-082-02",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-082-02"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-27450",
"datePublished": "2021-03-25T19:30:27.000Z",
"dateReserved": "2021-02-19T00:00:00.000Z",
"dateUpdated": "2024-08-03T20:48:17.146Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-27457 (GCVE-0-2021-27457)
Vulnerability from cvelistv5 – Published: 2021-05-20 11:51 – Updated: 2024-08-03 20:48- CWE-326 - INADEQUATE ENCRYPTION STRENGTH CWE-326
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsa-21-138-01 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Emerson Rosemount X-STREAM Gas Analyzer |
Affected:
X-STREAM enhanced XEGP – all revisions, X-STREAM enhanced XEGK – all revisions, X-STREAM enhanced XEFD – all revisions, X-STREAM enhanced XEXF – all revisions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T20:48:17.312Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-138-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Emerson Rosemount X-STREAM Gas Analyzer",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "X-STREAM enhanced XEGP \u2013 all revisions, X-STREAM enhanced XEGK \u2013 all revisions, X-STREAM enhanced XEFD \u2013 all revisions, X-STREAM enhanced XEXF \u2013 all revisions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The affected products utilize a weak encryption algorithm for storage of sensitive data, which may allow an attacker to more easily obtain credentials used for access."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-326",
"description": "INADEQUATE ENCRYPTION STRENGTH CWE-326",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-05-20T11:51:36.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-138-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2021-27457",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Emerson Rosemount X-STREAM Gas Analyzer",
"version": {
"version_data": [
{
"version_value": "X-STREAM enhanced XEGP \u2013 all revisions, X-STREAM enhanced XEGK \u2013 all revisions, X-STREAM enhanced XEFD \u2013 all revisions, X-STREAM enhanced XEXF \u2013 all revisions"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The affected products utilize a weak encryption algorithm for storage of sensitive data, which may allow an attacker to more easily obtain credentials used for access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "INADEQUATE ENCRYPTION STRENGTH CWE-326"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-138-01",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-138-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-27457",
"datePublished": "2021-05-20T11:51:36.000Z",
"dateReserved": "2021-02-19T00:00:00.000Z",
"dateUpdated": "2024-08-03T20:48:17.312Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-32010 (GCVE-0-2021-32010)
Vulnerability from cvelistv5 – Published: 2022-05-04 13:45 – Updated: 2024-08-03 23:17- CWE-326 - Inadequate Encryption Strength
| URL | Tags |
|---|---|
| https://www.secomea.com/support/cybersecurity-advisory/ | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Secomea | SiteManager |
Affected:
All , < 9.7
(custom)
|
|
| Secomea | LinkManager |
Affected:
unspecified , < 9.7
(custom)
|
|
| Secomea | GateManager |
Affected:
unspecified , < 9.7
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T23:17:28.463Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SiteManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.7",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
},
{
"product": "LinkManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.7",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.7",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Inadequate Encryption Strength vulnerability in TLS stack of Secomea SiteManager, LinkManager, GateManager may facilitate man in the middle attacks. This issue affects: Secomea SiteManager All versions prior to 9.7. Secomea LinkManager versions prior to 9.7. Secomea GateManager versions prior to 9.7."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-326",
"description": "CWE-326 Inadequate Encryption Strength",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-04T13:45:03.000Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"defect": [
"RD-5699"
],
"discovery": "INTERNAL"
},
"title": "Clients may connect to a GateManager with TLS 1.0",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"ID": "CVE-2021-32010",
"STATE": "PUBLIC",
"TITLE": "Clients may connect to a GateManager with TLS 1.0"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SiteManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "All",
"version_value": "9.7"
}
]
}
},
{
"product_name": "LinkManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "9.7"
}
]
}
},
{
"product_name": "GateManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "9.7"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Inadequate Encryption Strength vulnerability in TLS stack of Secomea SiteManager, LinkManager, GateManager may facilitate man in the middle attacks. This issue affects: Secomea SiteManager All versions prior to 9.7. Secomea LinkManager versions prior to 9.7. Secomea GateManager versions prior to 9.7."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-326 Inadequate Encryption Strength"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory/",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
]
},
"source": {
"defect": [
"RD-5699"
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2021-32010",
"datePublished": "2022-05-04T13:45:03.000Z",
"dateReserved": "2021-05-03T00:00:00.000Z",
"dateUpdated": "2024-08-03T23:17:28.463Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-32945 (GCVE-0-2021-32945)
Vulnerability from cvelistv5 – Published: 2022-04-01 22:17 – Updated: 2025-04-16 16:33- CWE-326 - Inadequate Encryption Strength
| URL | Tags |
|---|---|
| https://www.cisa.gov/uscert/ics/advisories/icsa-2… | x_refsource_CONFIRM |
| Vendor | Product | Version | |
|---|---|---|---|
| MDT Software | MDT AutoSave |
Affected:
unspecified , < 6.02.06
(custom)
|
|
| MDT Software | MDT AutoSave |
Affected:
7.00 , < 7.04
(custom)
|
|
| MDT Software | AutoSave for System Platform (A4SP) |
Affected:
unspecified , < 4.01
(custom)
|
|
| MDT Software | A4SP |
Affected:
5.00
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T23:33:56.098Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-189-02"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-32945",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T15:58:19.788465Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T16:33:53.886Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "MDT AutoSave",
"vendor": "MDT Software",
"versions": [
{
"lessThan": "6.02.06",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "MDT AutoSave",
"vendor": "MDT Software",
"versions": [
{
"lessThan": "7.04",
"status": "affected",
"version": "7.00",
"versionType": "custom"
}
]
},
{
"product": "AutoSave for System Platform (A4SP)",
"vendor": "MDT Software",
"versions": [
{
"lessThan": "4.01",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "A4SP",
"vendor": "MDT Software",
"versions": [
{
"status": "affected",
"version": "5.00"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Amir Preminger of Claroty Research reported these vulnerabilities to MDT Software."
}
],
"descriptions": [
{
"lang": "en",
"value": "An attacker could decipher the encryption and gain access to MDT AutoSave versions prior to v6.02.06."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-326",
"description": "CWE-326: Inadequate Encryption Strength",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-01T22:17:10.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-189-02"
}
],
"solutions": [
{
"lang": "en",
"value": "Updated versions of MDT AutoSave and AutoSave for System Platform (A4SP) were developed to address these vulnerabilities as follows:\nMDT AutoSave 6.x version: Version 6.02.06 (Released January 2021)\nMDT AutoSave 7.x version: Version 7.05 (Released December 2020)\nA4SP 4.x version: Version 4.01 (Released June 2021)\nA4SP 5.x version: Version 5.01 (Released May 2021)\n\nFor more information about these vulnerabilities, and to obtain and install the new versions, please contact MDT Software customer support."
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "MDT AutoSave Inadequate Encryption Strength",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2021-32945",
"STATE": "PUBLIC",
"TITLE": "MDT AutoSave Inadequate Encryption Strength"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "MDT AutoSave",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "6.02.06"
}
]
}
},
{
"product_name": "MDT AutoSave",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "7.00",
"version_value": "7.04"
}
]
}
},
{
"product_name": "AutoSave for System Platform (A4SP)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.01"
}
]
}
},
{
"product_name": "A4SP",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "5.00"
}
]
}
}
]
},
"vendor_name": "MDT Software"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Amir Preminger of Claroty Research reported these vulnerabilities to MDT Software."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An attacker could decipher the encryption and gain access to MDT AutoSave versions prior to v6.02.06."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-326: Inadequate Encryption Strength"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-189-02",
"refsource": "CONFIRM",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-189-02"
}
]
},
"solution": [
{
"lang": "en",
"value": "Updated versions of MDT AutoSave and AutoSave for System Platform (A4SP) were developed to address these vulnerabilities as follows:\nMDT AutoSave 6.x version: Version 6.02.06 (Released January 2021)\nMDT AutoSave 7.x version: Version 7.05 (Released December 2020)\nA4SP 4.x version: Version 4.01 (Released June 2021)\nA4SP 5.x version: Version 5.01 (Released May 2021)\n\nFor more information about these vulnerabilities, and to obtain and install the new versions, please contact MDT Software customer support."
}
],
"source": {
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-32945",
"datePublished": "2022-04-01T22:17:10.000Z",
"dateReserved": "2021-05-13T00:00:00.000Z",
"dateUpdated": "2025-04-16T16:33:53.886Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-35226 (GCVE-0-2021-35226)
Vulnerability from cvelistv5 – Published: 2022-10-10 00:00 – Updated: 2024-08-04 00:33- CWE-326 - Inadequate Encryption Strength
| Vendor | Product | Version | |
|---|---|---|---|
| SolarWinds | Network Configuration Manager |
Affected:
2020.2.5 and previous version , < 2020.2.5
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T00:33:51.270Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.solarwinds.com/trust-center/security-advisories/cve-2021-35226"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Network Configuration Manager",
"vendor": "SolarWinds",
"versions": [
{
"lessThan": "2020.2.5",
"status": "affected",
"version": "2020.2.5 and previous version",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "SolarWinds would like to thank Preston Deason, Chad Larsen and Zachary Riezenman for reporting on the issue in a responsible manner."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eAn entity in Network Configuration Manager product is misconfigured and exposing password field to Solarwinds Information Service (SWIS). Exposed credentials are encrypted and require authenticated access with an NCM role.\u003c/p\u003e"
}
],
"value": "An entity in Network Configuration Manager product is misconfigured and exposing password field to Solarwinds Information Service (SWIS). Exposed credentials are encrypted and require authenticated access with an NCM role."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-326",
"description": "CWE-326 Inadequate Encryption Strength",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T20:29:12.567Z",
"orgId": "49f11609-934d-4621-84e6-e02e032104d6",
"shortName": "SolarWinds"
},
"references": [
{
"url": "https://www.solarwinds.com/trust-center/security-advisories/cve-2021-35226"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eSolarWinds recommends\u202fcustomers upgrade to the latest version once it becomes generally available. \u003c/p\u003e"
}
],
"value": "SolarWinds recommends\u202fcustomers upgrade to the latest version once it becomes generally available."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Hashed Credential Exposure Vulnerability",
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "49f11609-934d-4621-84e6-e02e032104d6",
"assignerShortName": "SolarWinds",
"cveId": "CVE-2021-35226",
"datePublished": "2022-10-10T00:00:00.000Z",
"dateReserved": "2021-06-22T00:00:00.000Z",
"dateUpdated": "2024-08-04T00:33:51.270Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-36337 (GCVE-0-2021-36337)
Vulnerability from cvelistv5 – Published: 2021-12-21 17:05 – Updated: 2024-09-17 00:32- CWE-326 - Inadequate Encryption Strength
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/000193079 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Wyse Management Suite |
Affected:
unspecified , < 3.5
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T00:54:51.461Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/000193079"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Wyse Management Suite",
"vendor": "Dell",
"versions": [
{
"lessThan": "3.5",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2021-11-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Dell Wyse Management Suite version 3.3.1 and prior support insecure Transport Security Protocols TLS 1.0 and TLS 1.1 which are susceptible to Man-In-The-Middle attacks thereby compromising Confidentiality and Integrity of data."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-326",
"description": "CWE-326: Inadequate Encryption Strength",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-12-21T17:05:27.000Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.dell.com/support/kbdoc/000193079"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2021-11-18",
"ID": "CVE-2021-36337",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Wyse Management Suite",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "3.5"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell Wyse Management Suite version 3.3.1 and prior support insecure Transport Security Protocols TLS 1.0 and TLS 1.1 which are susceptible to Man-In-The-Middle attacks thereby compromising Confidentiality and Integrity of data."
}
]
},
"impact": {
"cvss": {
"baseScore": 6.5,
"baseSeverity": "Medium",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-326: Inadequate Encryption Strength"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/kbdoc/000193079",
"refsource": "MISC",
"url": "https://www.dell.com/support/kbdoc/000193079"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2021-36337",
"datePublished": "2021-12-21T17:05:27.861Z",
"dateReserved": "2021-07-08T00:00:00.000Z",
"dateUpdated": "2024-09-17T00:32:21.587Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-37209 (GCVE-0-2021-37209)
Vulnerability from cvelistv5 – Published: 2022-03-08 00:00 – Updated: 2025-08-12 11:10- CWE-326 - Inadequate Encryption Strength
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | RUGGEDCOM i800 |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM i801 |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM i802 |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM i803 |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM M2100 |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM M2200 |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM M969 |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RMC30 |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RMC8388 V4.X |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RMC8388 V5.X |
Affected:
0 , < V5.7.0
(custom)
|
|
| Siemens | RUGGEDCOM RP110 |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RS1600 |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RS1600F |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RS1600T |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RS400 |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RS401 |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RS416 |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RS416P |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RS416Pv2 V4.X |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RS416Pv2 V5.X |
Affected:
0 , < V5.7.0
(custom)
|
|
| Siemens | RUGGEDCOM RS416v2 V4.X |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RS416v2 V5.X |
Affected:
0 , < V5.7.0
(custom)
|
|
| Siemens | RUGGEDCOM RS8000 |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RS8000A |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RS8000H |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RS8000T |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RS900 |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RS900 (32M) V4.X |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RS900 (32M) V5.X |
Affected:
0 , < V5.7.0
(custom)
|
|
| Siemens | RUGGEDCOM RS900G |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RS900G (32M) V4.X |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RS900G (32M) V5.X |
Affected:
0 , < V5.7.0
(custom)
|
|
| Siemens | RUGGEDCOM RS900GP |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RS900L |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RS900M-GETS-C01 |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RS900M-GETS-XX |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RS900M-STND-C01 |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RS900M-STND-XX |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RS900W |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RS910 |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RS910L |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RS910W |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RS920L |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RS920W |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RS930L |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RS930W |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RS940G |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RS969 |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100 |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100 (32M) V4.X |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100 (32M) V5.X |
Affected:
0 , < V5.7.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100P |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100P (32M) V4.X |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RSG2100P (32M) V5.X |
Affected:
0 , < V5.7.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG2200 |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RSG2288 V4.X |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RSG2288 V5.X |
Affected:
0 , < V5.7.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG2300 V4.X |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RSG2300 V5.X |
Affected:
0 , < V5.7.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG2300P V4.X |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RSG2300P V5.X |
Affected:
0 , < V5.7.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG2488 V4.X |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RSG2488 V5.X |
Affected:
0 , < V5.7.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG907R |
Affected:
0 , < V5.7.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG908C |
Affected:
0 , < V5.7.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG909R |
Affected:
0 , < V5.7.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG910C |
Affected:
0 , < V5.7.0
(custom)
|
|
| Siemens | RUGGEDCOM RSG920P V4.X |
Affected:
0 , < V4.3.8
(custom)
|
|
| Siemens | RUGGEDCOM RSG920P V5.X |
Affected:
0 , < V5.7.0
(custom)
|
|
| Siemens | RUGGEDCOM RSL910 |
Affected:
0 , < V5.7.0
(custom)
|
|
| Siemens | RUGGEDCOM RST2228 |
Affected:
0 , < V5.7.0
(custom)
|
|
| Siemens | RUGGEDCOM RST2228P |
Affected:
0 , < V5.7.0
(custom)
|
|
| Siemens | RUGGEDCOM RST916C |
Affected:
0 , < V5.7.0
(custom)
|
|
| Siemens | RUGGEDCOM RST916P |
Affected:
0 , < V5.7.0
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T01:16:03.378Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-764417.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-37209",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:15:32.474081Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-21T13:55:53.304Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM i800",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM i801",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM i802",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM i803",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM M2100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM M2200",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM M969",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RMC30",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RMC8388 V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RMC8388 V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.7.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RP110",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS1600",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS1600F",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS1600T",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS400",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS401",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416P",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416Pv2 V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416Pv2 V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.7.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416v2 V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS416v2 V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.7.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS8000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS8000A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS8000H",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS8000T",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900 (32M) V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900 (32M) V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.7.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900G (32M) V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900G (32M) V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.7.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900GP",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900M-GETS-C01",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900M-GETS-XX",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900M-STND-C01",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900M-STND-XX",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS900W",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS910",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS910L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS910W",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS920L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS920W",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS930L",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS930W",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS940G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RS969",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100 (32M) V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100 (32M) V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.7.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100P",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100P (32M) V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2100P (32M) V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.7.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2200",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2288 V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2288 V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.7.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2300 V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2300 V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.7.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2300P V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2300P V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.7.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2488 V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG2488 V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.7.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG907R",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.7.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG908C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.7.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG909R",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.7.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG910C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.7.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG920P V4.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.3.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSG920P V5.X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.7.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RSL910",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.7.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RST2228",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.7.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RST2228P",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.7.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RST916C",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.7.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM RST916P",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.7.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM i800 (All versions \u003c V4.3.8), RUGGEDCOM i801 (All versions \u003c V4.3.8), RUGGEDCOM i802 (All versions \u003c V4.3.8), RUGGEDCOM i803 (All versions \u003c V4.3.8), RUGGEDCOM M2100 (All versions \u003c V4.3.8), RUGGEDCOM M2200 (All versions \u003c V4.3.8), RUGGEDCOM M969 (All versions \u003c V4.3.8), RUGGEDCOM RMC30 (All versions \u003c V4.3.8), RUGGEDCOM RMC8388 V4.X (All versions \u003c V4.3.8), RUGGEDCOM RMC8388 V5.X (All versions \u003c V5.7.0), RUGGEDCOM RP110 (All versions \u003c V4.3.8), RUGGEDCOM RS1600 (All versions \u003c V4.3.8), RUGGEDCOM RS1600F (All versions \u003c V4.3.8), RUGGEDCOM RS1600T (All versions \u003c V4.3.8), RUGGEDCOM RS400 (All versions \u003c V4.3.8), RUGGEDCOM RS401 (All versions \u003c V4.3.8), RUGGEDCOM RS416 (All versions \u003c V4.3.8), RUGGEDCOM RS416P (All versions \u003c V4.3.8), RUGGEDCOM RS416Pv2 V4.X (All versions \u003c V4.3.8), RUGGEDCOM RS416Pv2 V5.X (All versions \u003c V5.7.0), RUGGEDCOM RS416v2 V4.X (All versions \u003c V4.3.8), RUGGEDCOM RS416v2 V5.X (All versions \u003c V5.7.0), RUGGEDCOM RS8000 (All versions \u003c V4.3.8), RUGGEDCOM RS8000A (All versions \u003c V4.3.8), RUGGEDCOM RS8000H (All versions \u003c V4.3.8), RUGGEDCOM RS8000T (All versions \u003c V4.3.8), RUGGEDCOM RS900 (All versions \u003c V4.3.8), RUGGEDCOM RS900 (32M) V4.X (All versions \u003c V4.3.8), RUGGEDCOM RS900 (32M) V5.X (All versions \u003c V5.7.0), RUGGEDCOM RS900G (All versions \u003c V4.3.8), RUGGEDCOM RS900G (32M) V4.X (All versions \u003c V4.3.8), RUGGEDCOM RS900G (32M) V5.X (All versions \u003c V5.7.0), RUGGEDCOM RS900GP (All versions \u003c V4.3.8), RUGGEDCOM RS900L (All versions \u003c V4.3.8), RUGGEDCOM RS900M-GETS-C01 (All versions \u003c V4.3.8), RUGGEDCOM RS900M-GETS-XX (All versions \u003c V4.3.8), RUGGEDCOM RS900M-STND-C01 (All versions \u003c V4.3.8), RUGGEDCOM RS900M-STND-XX (All versions \u003c V4.3.8), RUGGEDCOM RS900W (All versions \u003c V4.3.8), RUGGEDCOM RS910 (All versions \u003c V4.3.8), RUGGEDCOM RS910L (All versions \u003c V4.3.8), RUGGEDCOM RS910W (All versions \u003c V4.3.8), RUGGEDCOM RS920L (All versions \u003c V4.3.8), RUGGEDCOM RS920W (All versions \u003c V4.3.8), RUGGEDCOM RS930L (All versions \u003c V4.3.8), RUGGEDCOM RS930W (All versions \u003c V4.3.8), RUGGEDCOM RS940G (All versions \u003c V4.3.8), RUGGEDCOM RS969 (All versions \u003c V4.3.8), RUGGEDCOM RSG2100 (All versions \u003c V4.3.8), RUGGEDCOM RSG2100 (32M) V4.X (All versions \u003c V4.3.8), RUGGEDCOM RSG2100 (32M) V5.X (All versions \u003c V5.7.0), RUGGEDCOM RSG2100P (All versions \u003c V4.3.8), RUGGEDCOM RSG2100P (32M) V4.X (All versions \u003c V4.3.8), RUGGEDCOM RSG2100P (32M) V5.X (All versions \u003c V5.7.0), RUGGEDCOM RSG2200 (All versions \u003c V4.3.8), RUGGEDCOM RSG2288 V4.X (All versions \u003c V4.3.8), RUGGEDCOM RSG2288 V5.X (All versions \u003c V5.7.0), RUGGEDCOM RSG2300 V4.X (All versions \u003c V4.3.8), RUGGEDCOM RSG2300 V5.X (All versions \u003c V5.7.0), RUGGEDCOM RSG2300P V4.X (All versions \u003c V4.3.8), RUGGEDCOM RSG2300P V5.X (All versions \u003c V5.7.0), RUGGEDCOM RSG2488 V4.X (All versions \u003c V4.3.8), RUGGEDCOM RSG2488 V5.X (All versions \u003c V5.7.0), RUGGEDCOM RSG907R (All versions \u003c V5.7.0), RUGGEDCOM RSG908C (All versions \u003c V5.7.0), RUGGEDCOM RSG909R (All versions \u003c V5.7.0), RUGGEDCOM RSG910C (All versions \u003c V5.7.0), RUGGEDCOM RSG920P V4.X (All versions \u003c V4.3.8), RUGGEDCOM RSG920P V5.X (All versions \u003c V5.7.0), RUGGEDCOM RSL910 (All versions \u003c V5.7.0), RUGGEDCOM RST2228 (All versions \u003c V5.7.0), RUGGEDCOM RST2228P (All versions \u003c V5.7.0), RUGGEDCOM RST916C (All versions \u003c V5.7.0), RUGGEDCOM RST916P (All versions \u003c V5.7.0). The SSH server on affected devices is configured to offer weak ciphers by default.\r\n\r\nThis could allow an unauthorized attacker in a man-in-the-middle position to read and modify any data passed over the connection between legitimate clients and the affected device."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:H/E:P/RL:U/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-326",
"description": "CWE-326: Inadequate Encryption Strength",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-12T11:10:51.567Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-764417.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-764417.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-37209",
"datePublished": "2022-03-08T00:00:00.000Z",
"dateReserved": "2021-07-21T00:00:00.000Z",
"dateUpdated": "2025-08-12T11:10:51.567Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Mitigation
Phase: Architecture and Design
Description:
- Use an encryption scheme that is currently considered to be strong by experts in the field.
CAPEC-112: Brute Force
In this attack, some asset (information, functionality, identity, etc.) is protected by a finite secret value. The attacker attempts to gain access to this asset by using trial-and-error to exhaustively explore all the possible secret values in the hope of finding the secret (or a value that is functionally equivalent) that will unlock the asset.
CAPEC-192: Protocol Analysis
An adversary engages in activities to decipher and/or decode protocol information for a network or application communication protocol used for transmitting information between interconnected nodes or systems on a packet-switched data network. While this type of analysis involves the analysis of a networking protocol inherently, it does not require the presence of an actual or physical network.
CAPEC-20: Encryption Brute Forcing
An attacker, armed with the cipher text and the encryption algorithm used, performs an exhaustive (brute force) search on the key space to determine the key that decrypts the cipher text to obtain the plaintext.