CWE-410
Insufficient Resource Pool
The product's resource pool is not large enough to handle peak demand, which allows an attacker to prevent others from accessing the resource by using a (relatively) large number of requests for resources.
CVE-2023-7033 (GCVE-0-2023-7033)
Vulnerability from cvelistv5 – Published: 2024-02-27 03:47 – Updated: 2025-01-16 04:31
VLAI
Summary
Insufficient Resource Pool vulnerability in Ethernet function of Mitsubishi Electric Corporation MELSEC iQ-R series CPU module, MELSEC iQ-L series CPU module, MELSEC iQ-R Ethernet Interface Module, MELSEC iQ-R CC-Link IE TSN Master/Local Module, CC-Link IE TSN Remote I/O Module, CC-Link IE TSN Analog-Digital Converter Module, CC-Link IE TSN Digital-Analog Converter Module, CC-Link IE TSN - CC-Link IE Field Network Bridge Module, CC-Link IE TSN - AnyWireASLINK Bridge Module, CC-Link IE TSN FPGA Module, CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY, MELSEC iQ-R Motion Module, MELSEC iQ-L Motion Module, MELSEC iQ-F FX5 Motion Module, MELSEC iQ-F Series CPU module, MELSEC iQ-F Series Ethernet module, MELSEC iQ-F Series Ethernet/IP module, MELSEC iQ-F Series OPC UA Module, MELSEC iQ-F Series CC-Link IE TSN master/local module, GOT2000 Series CC-Link IE TSN Communication Unit, FR-A800-E series inverters, FR-F800-E series inverters, FR-E800-E series inverters, INVERTER CC-Link IE TSN Plug-in option, INVERTER CC-Link IE TSN Safety Plug-in option, INVERTER CC-Link IE TSN communication function built-in type, MR-J5 series AC Servos MELSERVO, MR-JET series AC Servos MELSERVO, MR-MD333G series AC Servos MELSERVO, MR-JE series AC Servos MELSERVO, MELSERVO-J4 AC Servos MELSERVO and Embedded Type Servo System Controller allow a remote attacker to cause a temporary Denial of Service condition for a certain period of time in Ethernet communication of the products by performing TCP SYN Flood attack.
Severity
5.3 (Medium)
CWE
- CWE-410 - Insufficient Resource Pool
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://www.mitsubishielectric.com/en/psirt/vulne… | vendor-advisory |
| https://jvn.jp/vu/JVNVU96145466/index.html | government-resource |
| https://www.cisa.gov/news-events/ics-advisories/i… | government-resource |
Impacted products
164 products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-7033",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-02-27T15:54:01.953744Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-05T17:22:01.182Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T08:50:07.706Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-023_en.pdf"
},
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU96145466/index.html"
},
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-058-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R series CPU module R00CPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R series CPU module R01CPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R series CPU module R02CPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R series CPU module R04CPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R series CPU module R08CPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R series CPU module R16CPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R series CPU module R32CPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R series CPU module R120CPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R series CPU module R04ENCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R series CPU module R08ENCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R series CPU module R16ENCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R series CPU module R32ENCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R series CPU module R120ENCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R series CPU module R08SFCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R series CPU module R16SFCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R series CPU module R32SFCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R series CPU module R120SFCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R series CPU module R08PCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R series CPU module R16PCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R series CPU module R32PCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R series CPU module R120PCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R series CPU module R08PSFCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R series CPU module R16PSFCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R series CPU module R32PSFCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R series CPU module R120PSFCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-L series CPU module L04HCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-L series CPU module L08HCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-L series CPU module L16HCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-L series CPU module L32HCPU",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Ethernet Interface Module RJ71EN71",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R CC-Link IE TSN Master/Local Module RJ71GN11-T2",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R CC-Link IE TSN Master/Local Module RJ71GN11-SX",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R CC-Link IE TSN Master/Local Module RJ71GN11-EIP",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN Remote I/O Module NZ2GN2B1-32D",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN Remote I/O Module NZ2GN2B1-32T",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN Remote I/O Module NZ2GN2B1-32TE",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN Remote I/O Module NZ2GN2B1-32DT",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN Remote I/O Module NZ2GN2B1-32DTE",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN Remote I/O Module NZ2GN2B1-16D",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN Remote I/O Module NZ2GN2B1-16T",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN Remote I/O Module NZ2GN2B1-16TE",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN Remote I/O Module NZ2GN2S1-32D",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN Remote I/O Module NZ2GN2S1-32T",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN Remote I/O Module NZ2GN2S1-32TE",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN Remote I/O Module NZ2GN2S1-32DT",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN Remote I/O Module NZ2GN2S1-32DTE",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN Remote I/O Module NZ2GN2S1-16D",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN Remote I/O Module NZ2GN2S1-16T",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN Remote I/O Module NZ2GN2S1-16TE",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN Remote I/O Module NZ2GNCF1-32D",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN Remote I/O Module NZ2GNCF1-32T",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN Remote I/O Module NZ2GNCE3-32D",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN Remote I/O Module NZ2GNCE3-32DT",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN Remote I/O Module NZ2GN12A4-16D",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN Remote I/O Module NZ2GN12A4-16DE",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN Remote I/O Module NZ2GN12A2-16T",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN Remote I/O Module NZ2GN12A2-16TE",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN Remote I/O Module NZ2GN12A42-16DT",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN Remote I/O Module NZ2GN12A42-16DTE",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN Analog-Digital Converter Module NZ2GN2S-60AD4",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN Analog-Digital Converter Module NZ2GN2B-60AD4",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN Digital-Analog Converter Module NZ2GN2S-60DA4",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN Digital-Analog Converter Module NZ2GN2B-60DA4",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN - CC-Link IE Field Network Bridge Module NZ2GN-GFB",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN - AnyWireASLINK Bridge Module NZ2AW1GNAL",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN FPGA Module NZ2GN2S-D41P01",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN FPGA Module NZ2GN2S-D41D01",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN FPGA Module NZ2GN2S-D41PD02",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY NZ2GACP620-300",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY NZ2GACP620-60",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Motion Module RD78G4",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Motion Module RD78G8",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Motion Module RD78G16",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Motion Module RD78G32",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Motion Module RD78G64",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Motion Module RD78GHV",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-R Motion Module RD78GHW",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-L Motion Module LD78G4",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-L Motion Module LD78G16",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F FX5 Motion Module FX5-40SSC-G",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F FX5 Motion Module FX5-80SSC-G",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5U-32MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5U-64MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5U-80MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5U-32MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5U-64MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5U-80MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5U-32MT/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5U-64MT/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5U-80MT/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5U-32MR/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5U-64MR/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5U-80MR/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5U-32MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5U-64MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5U-80MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5U-32MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5U-64MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5U-80MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5UC-32MT/D",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5UC-64MT/D",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5UC-96MT/D",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5UC-32MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5UC-64MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5UC-96MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5UC-32MT/DS-TS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5UC-32MT/DSS-TS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5UC-32MR/DS-TS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5UJ-24MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5UJ-40MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5UJ-60MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5UJ-24MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5UJ-40MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5UJ-60MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5UJ-24MT/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5UJ-40MT/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5UJ-60MT/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5UJ-24MR/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5UJ-40MR/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5UJ-60MR/DS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5UJ-24MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5UJ-40MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5UJ-60MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5UJ-24MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5UJ-40MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5UJ-60MT/DSS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5UJ-24MT/ES-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5UJ-40MT/ES-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5UJ-60MT/ES-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5UJ-24MR/ES-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5UJ-40MR/ES-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5UJ-60MR/ES-A",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5S-30MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5S-40MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5S-60MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5S-80MT/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5S-30MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5S-40MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5S-60MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5S-80MR/ES",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5S-30MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5S-40MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5S-60MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CPU module FX5S-80MT/ESS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series Ethernet module FX5-ENET",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series Ethernet/IP module FX5-ENET/IP",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series OPC UA Module FX5-OPC",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSEC iQ-F Series CC-Link IE TSN master/local module FX5-CCLGN-MS",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GOT2000 Series CC-Link IE TSN Communication Unit GT25-J71GN13-T2",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FR-A800-E series inverters FR-A800-E series",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FR-F800-E series inverters FR-F800-E series",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "FR-E800-E series inverters FR-E800-E series",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "INVERTER CC-Link IE TSN Plug-in option FR-A8NCG",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "INVERTER CC-Link IE TSN Safety Plug-in option FR-A8NCG-S",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "INVERTER CC-Link IE TSN communication function built-in type FR-A800-GN",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MR-J5 series AC Servos MELSERVO MR-J5-A series",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MR-J5 series AC Servos MELSERVO MR-J5-G series",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MR-J5 series AC Servos MELSERVO MR-J5W-G series",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MR-J5 series AC Servos MELSERVO MR-J5D-G series",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MR-JET series AC Servos MELSERVO MR-JET-G series",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MR-MD333G series AC Servos MELSERVO MR-MD333G series",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MR-JE series AC Servos MELSERVO MR-JE-C series",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MELSERVO-J4 AC Servos MELSERVO MR-J4-GF series",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "versions A4 or later"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Embedded Type Servo System Controller MR-EM441G series",
"vendor": "Mitsubishi Electric Corporation",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Insufficient Resource Pool vulnerability in Ethernet function of Mitsubishi Electric Corporation MELSEC iQ-R series CPU module, MELSEC iQ-L series CPU module, MELSEC iQ-R Ethernet Interface Module, MELSEC iQ-R CC-Link IE TSN Master/Local Module, CC-Link IE TSN Remote I/O Module, CC-Link IE TSN Analog-Digital Converter Module, CC-Link IE TSN Digital-Analog Converter Module, CC-Link IE TSN - CC-Link IE Field Network Bridge Module, CC-Link IE TSN - AnyWireASLINK Bridge Module, CC-Link IE TSN FPGA Module, CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY, MELSEC iQ-R Motion Module, MELSEC iQ-L Motion Module, MELSEC iQ-F FX5 Motion Module, MELSEC iQ-F Series CPU module, MELSEC iQ-F Series Ethernet module, MELSEC iQ-F Series Ethernet/IP module, MELSEC iQ-F Series OPC UA Module, MELSEC iQ-F Series CC-Link IE TSN master/local module, GOT2000 Series CC-Link IE TSN Communication Unit, FR-A800-E series inverters, FR-F800-E series inverters, FR-E800-E series inverters, INVERTER CC-Link IE TSN Plug-in option, INVERTER CC-Link IE TSN Safety Plug-in option, INVERTER CC-Link IE TSN communication function built-in type, MR-J5 series AC Servos MELSERVO, MR-JET series AC Servos MELSERVO, MR-MD333G series AC Servos MELSERVO, MR-JE series AC Servos MELSERVO, MELSERVO-J4 AC Servos MELSERVO and Embedded Type Servo System Controller allow a remote attacker to cause a temporary Denial of Service condition for a certain period of time in Ethernet communication of the products by performing TCP SYN Flood attack."
}
],
"value": "Insufficient Resource Pool vulnerability in Ethernet function of Mitsubishi Electric Corporation MELSEC iQ-R series CPU module, MELSEC iQ-L series CPU module, MELSEC iQ-R Ethernet Interface Module, MELSEC iQ-R CC-Link IE TSN Master/Local Module, CC-Link IE TSN Remote I/O Module, CC-Link IE TSN Analog-Digital Converter Module, CC-Link IE TSN Digital-Analog Converter Module, CC-Link IE TSN - CC-Link IE Field Network Bridge Module, CC-Link IE TSN - AnyWireASLINK Bridge Module, CC-Link IE TSN FPGA Module, CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY, MELSEC iQ-R Motion Module, MELSEC iQ-L Motion Module, MELSEC iQ-F FX5 Motion Module, MELSEC iQ-F Series CPU module, MELSEC iQ-F Series Ethernet module, MELSEC iQ-F Series Ethernet/IP module, MELSEC iQ-F Series OPC UA Module, MELSEC iQ-F Series CC-Link IE TSN master/local module, GOT2000 Series CC-Link IE TSN Communication Unit, FR-A800-E series inverters, FR-F800-E series inverters, FR-E800-E series inverters, INVERTER CC-Link IE TSN Plug-in option, INVERTER CC-Link IE TSN Safety Plug-in option, INVERTER CC-Link IE TSN communication function built-in type, MR-J5 series AC Servos MELSERVO, MR-JET series AC Servos MELSERVO, MR-MD333G series AC Servos MELSERVO, MR-JE series AC Servos MELSERVO, MELSERVO-J4 AC Servos MELSERVO and Embedded Type Servo System Controller allow a remote attacker to cause a temporary Denial of Service condition for a certain period of time in Ethernet communication of the products by performing TCP SYN Flood attack."
}
],
"impacts": [
{
"descriptions": [
{
"lang": "en",
"value": "Denial of service"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-410",
"description": "CWE-410 Insufficient Resource Pool",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-16T04:31:21.198Z",
"orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"shortName": "Mitsubishi"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-023_en.pdf"
},
{
"tags": [
"government-resource"
],
"url": "https://jvn.jp/vu/JVNVU96145466/index.html"
},
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-058-01"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"assignerShortName": "Mitsubishi",
"cveId": "CVE-2023-7033",
"datePublished": "2024-02-27T03:47:04.725Z",
"dateReserved": "2023-12-21T01:41:37.913Z",
"dateUpdated": "2025-01-16T04:31:21.198Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-7392 (GCVE-0-2024-7392)
Vulnerability from cvelistv5 – Published: 2024-11-22 21:31 – Updated: 2024-11-25 16:43
VLAI
Title
ChargePoint Home Flex Bluetooth Low Energy Denial-of-Service Vulnerability
Summary
ChargePoint Home Flex Bluetooth Low Energy Denial-of-Service Vulnerability. This vulnerability allows network-adjacent attackers to create a denial-of-service condition on affected installations of ChargePoint Home Flex charging devices. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the connection handling of the Bluetooth Low Energy interface. The issue results from limiting the number of active connections to the product. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-21455.
Severity
4.3 (Medium)
CWE
- CWE-410 - Insufficient Resource Pool
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_research-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| ChargePoint | Home Flex |
Affected:
5.5.3.13
|
Date Public
2024-08-01 20:21
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-7392",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-25T16:42:56.784410Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-25T16:43:04.607Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Home Flex",
"vendor": "ChargePoint",
"versions": [
{
"status": "affected",
"version": "5.5.3.13"
}
]
}
],
"dateAssigned": "2024-08-01T20:11:59.373Z",
"datePublic": "2024-08-01T20:21:38.604Z",
"descriptions": [
{
"lang": "en",
"value": "ChargePoint Home Flex Bluetooth Low Energy Denial-of-Service Vulnerability. This vulnerability allows network-adjacent attackers to create a denial-of-service condition on affected installations of ChargePoint Home Flex charging devices. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the connection handling of the Bluetooth Low Energy interface. The issue results from limiting the number of active connections to the product. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-21455."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-410",
"description": "CWE-410: Insufficient Resource Pool",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-22T21:31:27.805Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-24-1047",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-24-1047/"
}
],
"source": {
"lang": "en",
"value": "Todd Manning"
},
"title": "ChargePoint Home Flex Bluetooth Low Energy Denial-of-Service Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2024-7392",
"datePublished": "2024-11-22T21:31:27.805Z",
"dateReserved": "2024-08-01T20:11:59.349Z",
"dateUpdated": "2024-11-25T16:43:04.607Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-0453 (GCVE-0-2025-0453)
Vulnerability from cvelistv5 – Published: 2025-03-20 10:11 – Updated: 2025-10-15 12:50
VLAI
Title
Denial of Service through Batched Queries in GraphQL in mlflow/mlflow
Summary
In mlflow/mlflow version 2.17.2, the `/graphql` endpoint is vulnerable to a denial of service attack. An attacker can create large batches of queries that repeatedly request all runs from a given experiment. This can tie up all the workers allocated by MLFlow, rendering the application unable to respond to other requests. This vulnerability is due to uncontrolled resource consumption.
Severity
5.9 (Medium)
CWE
- CWE-410 - Insufficient Resource Pool
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| mlflow | mlflow/mlflow |
Affected:
unspecified , ≤ latest
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-0453",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-20T15:51:13.787242Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-20T15:51:25.860Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://huntr.com/bounties/788327ec-714a-4d5c-83aa-8df04dd7612b"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "mlflow/mlflow",
"vendor": "mlflow",
"versions": [
{
"lessThanOrEqual": "latest",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In mlflow/mlflow version 2.17.2, the `/graphql` endpoint is vulnerable to a denial of service attack. An attacker can create large batches of queries that repeatedly request all runs from a given experiment. This can tie up all the workers allocated by MLFlow, rendering the application unable to respond to other requests. This vulnerability is due to uncontrolled resource consumption."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-410",
"description": "CWE-410 Insufficient Resource Pool",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-15T12:50:04.768Z",
"orgId": "c09c270a-b464-47c1-9133-acb35b22c19a",
"shortName": "@huntr_ai"
},
"references": [
{
"url": "https://huntr.com/bounties/788327ec-714a-4d5c-83aa-8df04dd7612b"
}
],
"source": {
"advisory": "788327ec-714a-4d5c-83aa-8df04dd7612b",
"discovery": "EXTERNAL"
},
"title": "Denial of Service through Batched Queries in GraphQL in mlflow/mlflow"
}
},
"cveMetadata": {
"assignerOrgId": "c09c270a-b464-47c1-9133-acb35b22c19a",
"assignerShortName": "@huntr_ai",
"cveId": "CVE-2025-0453",
"datePublished": "2025-03-20T10:11:02.779Z",
"dateReserved": "2025-01-13T23:25:07.844Z",
"dateUpdated": "2025-10-15T12:50:04.768Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-12986 (GCVE-0-2025-12986)
Vulnerability from cvelistv5 – Published: 2025-12-04 21:55 – Updated: 2025-12-05 15:40
VLAI
Title
Denial of Service Vulnerability in Silicon Labs WF200 and WGM160P Devices
Summary
When a WF200/WGM160P device is configured to operate as an Access Point, it may be vulnerable to a denial of service triggered by a malformed packet. The device may recover automatically or require a hard reset.
Severity
CWE
- CWE-410 - Insufficient Resource Pool
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://community.silabs.com/068Vm00000akaGr | vendor-advisorypermissions-required |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| silabs.com | Gecko SDK |
Affected:
0 , ≤ 4.5.0
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-12986",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-05T15:39:17.136154Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-05T15:40:13.811Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"packageName": "GSDK",
"product": "Gecko SDK",
"repo": "https://github.com/SiliconLabs/gecko_sdk",
"vendor": "silabs.com",
"versions": [
{
"lessThanOrEqual": "4.5.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003e\n\n\u003cdiv\u003eWhen a WF200/WGM160P device is configured to operate as an Access Point, it may be vulnerable to a denial of\u0026nbsp;service triggered by a malformed packet. The device may recover automatically or require a hard reset.\u0026nbsp;\u003c/div\u003e\n\n\u003cbr\u003e\u003c/div\u003e"
}
],
"value": "When a WF200/WGM160P device is configured to operate as an Access Point, it may be vulnerable to a denial of\u00a0service triggered by a malformed packet. The device may recover automatically or require a hard reset."
}
],
"impacts": [
{
"capecId": "CAPEC-125",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-125 Flooding"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "ADJACENT",
"baseScore": 6,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-410",
"description": "CWE-410 Insufficient Resource Pool",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-04T21:55:59.291Z",
"orgId": "030b2754-1501-44a4-bef8-48be86a33bf4",
"shortName": "Silabs"
},
"references": [
{
"tags": [
"vendor-advisory",
"permissions-required"
],
"url": "https://community.silabs.com/068Vm00000akaGr"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Denial of Service Vulnerability in Silicon Labs WF200 and WGM160P Devices",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "030b2754-1501-44a4-bef8-48be86a33bf4",
"assignerShortName": "Silabs",
"cveId": "CVE-2025-12986",
"datePublished": "2025-12-04T21:55:59.291Z",
"dateReserved": "2025-11-10T22:42:20.103Z",
"dateUpdated": "2025-12-05T15:40:13.811Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-20103 (GCVE-0-2025-20103)
Vulnerability from cvelistv5 – Published: 2025-05-13 21:02 – Updated: 2025-11-03 19:35
VLAI
Summary
Insufficient resource pool in the core management mechanism for some Intel(R) Processors may allow an authenticated user to potentially enable denial of service via local access.
Severity
6.5 (Medium)
CWE
- Denial of Service
- CWE-410 - Insufficient Resource Pool
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Intel(R) Processors |
Affected:
See references
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-20103",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-14T13:49:36.586820Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-14T13:49:44.258Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T19:35:23.163Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://lists.debian.org/debian-lts-announce/2025/05/msg00021.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Intel(R) Processors",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "See references"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Insufficient resource pool in the core management mechanism for some Intel(R) Processors may allow an authenticated user to potentially enable denial of service via local access."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:N/A:H",
"version": "3.1"
},
"cvssV4_0": {
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "LOCAL",
"baseScore": 5.7,
"baseSeverity": "MEDIUM",
"privilegesRequired": "LOW",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Denial of Service",
"lang": "en"
},
{
"cweId": "CWE-410",
"description": "Insufficient Resource Pool",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-13T21:02:15.127Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"name": "https://intel.com/content/www/us/en/security-center/advisory/intel-sa-01244.html",
"url": "https://intel.com/content/www/us/en/security-center/advisory/intel-sa-01244.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2025-20103",
"datePublished": "2025-05-13T21:02:15.127Z",
"dateReserved": "2024-10-11T03:00:12.239Z",
"dateUpdated": "2025-11-03T19:35:23.163Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-2134 (GCVE-0-2025-2134)
Vulnerability from cvelistv5 – Published: 2026-02-04 21:07 – Updated: 2026-02-04 21:19
VLAI
Title
IBM Jazz Reporting Service Denial of Service
Summary
IBM Jazz Reporting Service could allow an authenticated user on the network to affect the system's performance using complicated queries due to insufficient resource pooling.
Severity
CWE
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.ibm.com/support/pages/node/7258083 | vendor-advisorypatch |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| IBM | Jazz Reporting Service |
Affected:
7.1 , ≤ 7.1iFix006
(semver)
Affected: 7.0.3 , ≤ 7.0.3iFix020 (semver) cpe:2.3:a:ibm:jazz_reporting_service:7.0.3:*:*:*:*:*:*:* cpe:2.3:a:ibm:jazz_reporting_service:7.0.3:iFix020:*:*:*:*:*:* cpe:2.3:a:ibm:jazz_reporting_service:7.1:*:*:*:*:*:*:* cpe:2.3:a:ibm:jazz_reporting_service:7.1:iFix006:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-2134",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-04T21:19:06.765954Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-04T21:19:26.765Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:a:ibm:jazz_reporting_service:7.0.3:*:*:*:*:*:*:*",
"cpe:2.3:a:ibm:jazz_reporting_service:7.0.3:iFix020:*:*:*:*:*:*",
"cpe:2.3:a:ibm:jazz_reporting_service:7.1:*:*:*:*:*:*:*",
"cpe:2.3:a:ibm:jazz_reporting_service:7.1:iFix006:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "Jazz Reporting Service",
"vendor": "IBM",
"versions": [
{
"lessThanOrEqual": "7.1iFix006",
"status": "affected",
"version": "7.1",
"versionType": "semver"
},
{
"lessThanOrEqual": "7.0.3iFix020",
"status": "affected",
"version": "7.0.3",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eIBM Jazz Reporting Service could allow an authenticated user on the network to affect the system\u0027s performance using complicated queries due to insufficient resource pooling. \u003c/span\u003e\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "IBM Jazz Reporting Service could allow an authenticated user on the network to affect the system\u0027s performance using complicated queries due to insufficient resource pooling."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 3.5,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-410",
"description": "CWE-410",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-04T21:10:40.686Z",
"orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"shortName": "ibm"
},
"references": [
{
"tags": [
"vendor-advisory",
"patch"
],
"url": "https://www.ibm.com/support/pages/node/7258083"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eIBM strongly recommends addressing the vulnerability now by applying the iFix listed below:\u003c/p\u003e\u003cdiv\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003eProduct\u003c/td\u003e\u003ctd\u003eVersion\u003c/td\u003e\u003ctd\u003eiFix\u003c/td\u003e\u003ctd\u003eRemediation / First Fix\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003eIBM Jazz Reporting Service\u003c/td\u003e\u003ctd\u003e7.1\u003c/td\u003e\u003ctd\u003e7.1iFix007\u003c/td\u003e\u003ctd\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ibm.com/support/fixcentral/swg/downloadFixes?parent=IBM%20Engineering\u0026amp;product=ibm/Rational/IBM+Engineering+Lifecycle+Management\u0026amp;release=All\u0026amp;platform=All\u0026amp;function=fixId\u0026amp;fixids=7.1-IBM-ELM-iFix007\u0026amp;includeRequisites=0\u0026amp;includeSupersedes=0\u0026amp;downloadMethod=ddp\u0026amp;login=true\"\u003eFix Central - 7.1\u003c/a\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003eIBM Jazz Reporting Service\u003c/td\u003e\u003ctd\u003e7.0.3\u003c/td\u003e\u003ctd\u003e7.0.3iFix021\u003c/td\u003e\u003ctd\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ibm.com/support/fixcentral/swg/doSelectFixes?options.selectedFixes=7.0.3-IBM-ELM-iFix021\u0026amp;continue=1\"\u003eFix Central - 7.0.3\u003c/a\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e\u003c/div\u003e\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "IBM strongly recommends addressing the vulnerability now by applying the iFix listed below:\n\nProductVersioniFixRemediation / First FixIBM Jazz Reporting Service7.17.1iFix007 Fix Central - 7.1 https://www.ibm.com/support/fixcentral/swg/downloadFixes IBM Jazz Reporting Service7.0.37.0.3iFix021 Fix Central - 7.0.3 https://www.ibm.com/support/fixcentral/swg/doSelectFixes"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "IBM Jazz Reporting Service Denial of Service",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"assignerShortName": "ibm",
"cveId": "CVE-2025-2134",
"datePublished": "2026-02-04T21:07:26.354Z",
"dateReserved": "2025-03-09T18:43:29.483Z",
"dateUpdated": "2026-02-04T21:19:26.765Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-27479 (GCVE-0-2025-27479)
Vulnerability from cvelistv5 – Published: 2025-04-08 17:23 – Updated: 2026-02-13 19:32
VLAI
Title
Kerberos Key Distribution Proxy Service Denial of Service Vulnerability
Summary
Insufficient resource pool in Windows Kerberos allows an unauthorized attacker to deny service over a network.
Severity
CWE
- CWE-410 - Insufficient Resource Pool
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://msrc.microsoft.com/update-guide/vulnerabi… | vendor-advisorypatch |
Impacted products
12 products
| Vendor | Product | Version | |
|---|---|---|---|
| Microsoft | Windows Server 2012 |
Affected:
6.2.9200.0 , < 6.2.9200.25423
(custom)
|
|
| Microsoft | Windows Server 2012 (Server Core installation) |
Affected:
6.2.9200.0 , < 6.2.9200.25423
(custom)
|
|
| Microsoft | Windows Server 2012 R2 |
Affected:
6.3.9600.0 , < 6.3.9600.22523
(custom)
|
|
| Microsoft | Windows Server 2012 R2 (Server Core installation) |
Affected:
6.3.9600.0 , < 6.3.9600.22523
(custom)
|
|
| Microsoft | Windows Server 2016 |
Affected:
10.0.14393.0 , < 10.0.14393.7969
(custom)
|
|
| Microsoft | Windows Server 2016 (Server Core installation) |
Affected:
10.0.14393.0 , < 10.0.14393.7969
(custom)
|
|
| Microsoft | Windows Server 2019 |
Affected:
10.0.17763.0 , < 10.0.17763.7136
(custom)
|
|
| Microsoft | Windows Server 2019 (Server Core installation) |
Affected:
10.0.17763.0 , < 10.0.17763.7136
(custom)
|
|
| Microsoft | Windows Server 2022 |
Affected:
10.0.20348.0 , < 10.0.20348.3453
(custom)
|
|
| Microsoft | Windows Server 2022, 23H2 Edition (Server Core installation) |
Affected:
10.0.25398.0 , < 10.0.25398.1551
(custom)
|
|
| Microsoft | Windows Server 2025 |
Affected:
10.0.26100.0 , < 10.0.26100.3775
(custom)
|
|
| Microsoft | Windows Server 2025 (Server Core installation) |
Affected:
10.0.26100.0 , < 10.0.26100.3775
(custom)
|
Date Public
2025-04-08 07:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-27479",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-08T20:11:13.377728Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-08T20:11:25.942Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"platforms": [
"x64-based Systems"
],
"product": "Windows Server 2012",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "6.2.9200.25423",
"status": "affected",
"version": "6.2.9200.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"x64-based Systems"
],
"product": "Windows Server 2012 (Server Core installation)",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "6.2.9200.25423",
"status": "affected",
"version": "6.2.9200.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"x64-based Systems"
],
"product": "Windows Server 2012 R2",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "6.3.9600.22523",
"status": "affected",
"version": "6.3.9600.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"x64-based Systems"
],
"product": "Windows Server 2012 R2 (Server Core installation)",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "6.3.9600.22523",
"status": "affected",
"version": "6.3.9600.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"x64-based Systems"
],
"product": "Windows Server 2016",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "10.0.14393.7969",
"status": "affected",
"version": "10.0.14393.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"x64-based Systems"
],
"product": "Windows Server 2016 (Server Core installation)",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "10.0.14393.7969",
"status": "affected",
"version": "10.0.14393.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"x64-based Systems"
],
"product": "Windows Server 2019",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "10.0.17763.7136",
"status": "affected",
"version": "10.0.17763.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"x64-based Systems"
],
"product": "Windows Server 2019 (Server Core installation)",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "10.0.17763.7136",
"status": "affected",
"version": "10.0.17763.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"x64-based Systems"
],
"product": "Windows Server 2022",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "10.0.20348.3453",
"status": "affected",
"version": "10.0.20348.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"x64-based Systems"
],
"product": "Windows Server 2022, 23H2 Edition (Server Core installation)",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "10.0.25398.1551",
"status": "affected",
"version": "10.0.25398.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"x64-based Systems"
],
"product": "Windows Server 2025",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "10.0.26100.3775",
"status": "affected",
"version": "10.0.26100.0",
"versionType": "custom"
}
]
},
{
"platforms": [
"x64-based Systems"
],
"product": "Windows Server 2025 (Server Core installation)",
"vendor": "Microsoft",
"versions": [
{
"lessThan": "10.0.26100.3775",
"status": "affected",
"version": "10.0.26100.0",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2019:*:*:*:*:*:*:*:*",
"versionEndExcluding": "10.0.17763.7136",
"versionStartIncluding": "10.0.17763.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2019:*:*:*:*:*:*:*:*",
"versionEndExcluding": "10.0.17763.7136",
"versionStartIncluding": "10.0.17763.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2022:*:*:*:*:*:*:*:*",
"versionEndExcluding": "10.0.20348.3453",
"versionStartIncluding": "10.0.20348.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2025:*:*:*:*:*:*:*:*",
"versionEndExcluding": "10.0.26100.3775",
"versionStartIncluding": "10.0.26100.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_23h2:*:*:*:*:*:*:*:*",
"versionEndExcluding": "10.0.25398.1551",
"versionStartIncluding": "10.0.25398.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2025:*:*:*:*:*:*:*:*",
"versionEndExcluding": "10.0.26100.3775",
"versionStartIncluding": "10.0.26100.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2016:*:*:*:*:*:*:*:*",
"versionEndExcluding": "10.0.14393.7969",
"versionStartIncluding": "10.0.14393.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2016:*:*:*:*:*:*:*:*",
"versionEndExcluding": "10.0.14393.7969",
"versionStartIncluding": "10.0.14393.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2012:*:*:*:*:*:*:x64:*",
"versionEndExcluding": "6.2.9200.25423",
"versionStartIncluding": "6.2.9200.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2012:*:*:*:*:*:*:x64:*",
"versionEndExcluding": "6.2.9200.25423",
"versionStartIncluding": "6.2.9200.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2012_R2:*:*:*:*:*:*:x64:*",
"versionEndExcluding": "6.3.9600.22523",
"versionStartIncluding": "6.3.9600.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2012_R2:*:*:*:*:*:*:x64:*",
"versionEndExcluding": "6.3.9600.22523",
"versionStartIncluding": "6.3.9600.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"datePublic": "2025-04-08T07:00:00.000Z",
"descriptions": [
{
"lang": "en-US",
"value": "Insufficient resource pool in Windows Kerberos allows an unauthorized attacker to deny service over a network."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:U/RL:O/RC:C",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-410",
"description": "CWE-410: Insufficient Resource Pool",
"lang": "en-US",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-13T19:32:37.059Z",
"orgId": "f38d906d-7342-40ea-92c1-6c4a2c6478c8",
"shortName": "microsoft"
},
"references": [
{
"name": "Kerberos Key Distribution Proxy Service Denial of Service Vulnerability",
"tags": [
"vendor-advisory",
"patch"
],
"url": "https://msrc.microsoft.com/update-guide/vulnerability/CVE-2025-27479"
}
],
"title": "Kerberos Key Distribution Proxy Service Denial of Service Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "f38d906d-7342-40ea-92c1-6c4a2c6478c8",
"assignerShortName": "microsoft",
"cveId": "CVE-2025-27479",
"datePublished": "2025-04-08T17:23:20.139Z",
"dateReserved": "2025-02-26T14:42:05.977Z",
"dateUpdated": "2026-02-13T19:32:37.059Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-27694 (GCVE-0-2025-27694)
Vulnerability from cvelistv5 – Published: 2025-04-02 00:12 – Updated: 2025-04-02 13:24
VLAI
Summary
Dell Wyse Management Suite, versions prior to WMS 5.1, contains an Insufficient Resource Pool vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Denial of service.
Severity
5.3 (Medium)
CWE
- CWE-410 - Insufficient Resource Pool
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00029651… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Wyse Management Suite |
Affected:
N/A , < 5.1
(semver)
|
Date Public
2025-04-01 06:30
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-27694",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-02T13:19:09.622801Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-02T13:24:43.503Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Wyse Management Suite",
"vendor": "Dell",
"versions": [
{
"lessThan": "5.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Dell Technologies would like to thank Alain Mowat from Orange Cyberdefense Switzerland\u0027s research lab for reporting these issues."
}
],
"datePublic": "2025-04-01T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell Wyse Management Suite, versions prior to WMS 5.1, contains an Insufficient Resource Pool vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Denial of service.\u003cbr\u003e"
}
],
"value": "Dell Wyse Management Suite, versions prior to WMS 5.1, contains an Insufficient Resource Pool vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Denial of service."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-410",
"description": "CWE-410: Insufficient Resource Pool",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-04-02T00:12:16.032Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000296515/dsa-2025-135"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2025-27694",
"datePublished": "2025-04-02T00:12:16.032Z",
"dateReserved": "2025-03-05T07:33:28.315Z",
"dateUpdated": "2025-04-02T13:24:43.503Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-41653 (GCVE-0-2025-41653)
Vulnerability from cvelistv5 – Published: 2025-05-27 08:38 – Updated: 2025-05-27 13:12
VLAI
Title
Weidmueller: Denial-of-Service Vulnerability in the web server functionality of Industrial Ethernet Switches
Summary
An unauthenticated remote attacker can exploit a denial-of-service vulnerability in the device's web server functionality by sending a specially crafted HTTP request with a malicious header, potentially causing the server to crash or become unresponsive.
Severity
7.5 (High)
CWE
- CWE-410 - Insufficient Resource Pool
Assigner
References
1 reference
Impacted products
13 products
| Vendor | Product | Version | |
|---|---|---|---|
| Weidmueller | IE-SW-VL05M-5TX |
Affected:
0.0.0 , < 3.6.32
(semver)
|
|
| Weidmueller | IE-SW-VL05MT-5TX |
Affected:
0.0.0 , < 3.6.32
(semver)
|
|
| Weidmueller | IE-SW-VL08MT-8TX |
Affected:
0.0.0 , < 3.5.36
(semver)
|
|
| Weidmueller | IE-SW-VL08MT-5TX-1SC-2SCS |
Affected:
0.0.0 , < 3.5.36
(semver)
|
|
| Weidmueller | IE-SW-VL08MT-6TX-2SC |
Affected:
0.0.0 , < 3.5.36
(semver)
|
|
| Weidmueller | IE-SW-VL08MT-6TX-2ST |
Affected:
0.0.0 , < 3.5.36
(semver)
|
|
| Weidmueller | IE-SW-VL08MT-6TX-2SCS |
Affected:
0.0.0 , < 3.5.36
(semver)
|
|
| Weidmueller | IE-SW-PL10M-3GT-7TX |
Affected:
0.0.0 , < 3.3.34
(semver)
|
|
| Weidmueller | IE-SW-PL10MT-3GT-7TX |
Affected:
0.0.0 , < 3.3.34
(semver)
|
|
| Weidmueller | IE-SW-PL16M-16TX |
Affected:
0.0.0 , < 3.4.32
(semver)
|
|
| Weidmueller | IE-SW-PL16MT-16TX |
Affected:
0.0.0 , < 3.4.32
(semver)
|
|
| Weidmueller | IE-SW-PL18M-2GC-16TX |
Affected:
0.0.0 , < 3.4.40
(semver)
|
|
| Weidmueller | IE-SW-PL18MT-2GC-16TX |
Affected:
0.0.0 , < 3.4.40
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41653",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-27T13:08:48.596317Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-27T13:12:39.961Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "IE-SW-VL05M-5TX",
"vendor": "Weidmueller",
"versions": [
{
"lessThan": "3.6.32",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "IE-SW-VL05MT-5TX",
"vendor": "Weidmueller",
"versions": [
{
"lessThan": "3.6.32",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "IE-SW-VL08MT-8TX",
"vendor": "Weidmueller",
"versions": [
{
"lessThan": "3.5.36",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "IE-SW-VL08MT-5TX-1SC-2SCS",
"vendor": "Weidmueller",
"versions": [
{
"lessThan": "3.5.36",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "IE-SW-VL08MT-6TX-2SC",
"vendor": "Weidmueller",
"versions": [
{
"lessThan": "3.5.36",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "IE-SW-VL08MT-6TX-2ST",
"vendor": "Weidmueller",
"versions": [
{
"lessThan": "3.5.36",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "IE-SW-VL08MT-6TX-2SCS",
"vendor": "Weidmueller",
"versions": [
{
"lessThan": "3.5.36",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "IE-SW-PL10M-3GT-7TX",
"vendor": "Weidmueller",
"versions": [
{
"lessThan": "3.3.34",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "IE-SW-PL10MT-3GT-7TX",
"vendor": "Weidmueller",
"versions": [
{
"lessThan": "3.3.34",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "IE-SW-PL16M-16TX",
"vendor": "Weidmueller",
"versions": [
{
"lessThan": "3.4.32",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "IE-SW-PL16MT-16TX",
"vendor": "Weidmueller",
"versions": [
{
"lessThan": "3.4.32",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "IE-SW-PL18M-2GC-16TX",
"vendor": "Weidmueller",
"versions": [
{
"lessThan": "3.4.40",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "IE-SW-PL18MT-2GC-16TX",
"vendor": "Weidmueller",
"versions": [
{
"lessThan": "3.4.40",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated remote attacker can exploit a denial-of-service vulnerability in the device\u0027s web server functionality by sending a specially crafted HTTP request with a malicious header, potentially causing the server to crash or become unresponsive."
}
],
"value": "An unauthenticated remote attacker can exploit a denial-of-service vulnerability in the device\u0027s web server functionality by sending a specially crafted HTTP request with a malicious header, potentially causing the server to crash or become unresponsive."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-410",
"description": "CWE-410 Insufficient Resource Pool",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-27T08:38:29.005Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/en/advisories/VDE-2025-044/"
}
],
"source": {
"advisory": "VDE-2025-044",
"defect": [
"CERT@VDE#641785"
],
"discovery": "UNKNOWN"
},
"title": "Weidmueller: Denial-of-Service Vulnerability in the web server functionality of Industrial Ethernet Switches",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41653",
"datePublished": "2025-05-27T08:38:29.005Z",
"dateReserved": "2025-04-16T11:17:48.306Z",
"dateUpdated": "2025-05-27T13:12:39.961Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2026-34019 (GCVE-0-2026-34019)
Vulnerability from cvelistv5 – Published: 2026-05-13 14:12 – Updated: 2026-05-13 16:16
VLAI
Title
BIG-IP BFD vulnerability
Summary
When Bidirectional Forwarding Detection (BFD) is configured in Static and Dynamic routing protocols, undisclosed traffic can cause the Traffic Management Microkernel (TMM) to stop processing BFD packets and cause the configured routing protocol to fail over. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.
Severity
5.3 (Medium)
CWE
- CWE-410 - Insufficient Resource Pool
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://my.f5.com/manage/s/article/K000150508 | vendor-advisorypatch |
Impacted products
Date Public
2026-05-13 14:00
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-34019",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-13T16:00:14.700470Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-13T16:16:34.572Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"modules": [
"All Modules"
],
"product": "BIG-IP",
"vendor": "F5",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "21.0.0",
"versionType": "custom"
},
{
"lessThan": "17.5.1",
"status": "affected",
"version": "17.5.0",
"versionType": "custom"
},
{
"lessThan": "17.1.3",
"status": "affected",
"version": "17.1.0",
"versionType": "custom"
},
{
"lessThan": "*",
"status": "affected",
"version": "16.1.0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "F5"
}
],
"datePublic": "2026-05-13T14:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eWhen Bidirectional Forwarding Detection (BFD) is configured in Static and Dynamic routing protocols, undisclosed traffic can cause the Traffic Management Microkernel (TMM) to stop processing BFD packets and cause the configured routing protocol to fail over.\u003c/span\u003e\u0026nbsp; Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated."
}
],
"value": "When Bidirectional Forwarding Detection (BFD) is configured in Static and Dynamic routing protocols, undisclosed traffic can cause the Traffic Management Microkernel (TMM) to stop processing BFD packets and cause the configured routing protocol to fail over.\u00a0 Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-410",
"description": "CWE-410: Insufficient Resource Pool",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-13T14:12:29.552Z",
"orgId": "9dacffd4-cb11-413f-8451-fbbfd4ddc0ab",
"shortName": "f5"
},
"references": [
{
"tags": [
"vendor-advisory",
"patch"
],
"url": "https://my.f5.com/manage/s/article/K000150508"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "BIG-IP BFD vulnerability",
"x_generator": {
"engine": "F5 SIRTBot v1.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "9dacffd4-cb11-413f-8451-fbbfd4ddc0ab",
"assignerShortName": "f5",
"cveId": "CVE-2026-34019",
"datePublished": "2026-05-13T14:12:29.552Z",
"dateReserved": "2026-04-30T23:02:33.933Z",
"dateUpdated": "2026-05-13T16:16:34.572Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
Mitigation
Phase: Architecture and Design
Description:
- Do not perform resource-intensive transactions for unauthenticated users and/or invalid requests.
Mitigation
Phase: Architecture and Design
Description:
- Consider implementing a velocity check mechanism which would detect abusive behavior.
Mitigation
Phase: Operation
Description:
- Consider load balancing as an option to handle heavy loads.
Mitigation
Phase: Implementation
Description:
- Make sure that resource handles are properly closed when no longer needed.
Mitigation
Phase: Architecture and Design
Description:
- Identify the system's resource intensive operations and consider protecting them from abuse (e.g. malicious automated script which runs the resources out).
No CAPEC attack patterns related to this CWE.