CWE-668

Exposure of Resource to Wrong Sphere

The product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource.

CVE-2022-21947 (GCVE-0-2022-21947)

Vulnerability from cvelistv5 – Published: 2022-04-01 06:40 – Updated: 2024-09-16 19:20
VLAI
Title
rancher desktop: Dashboard API is network accessible
Summary
A Exposure of Resource to Wrong Sphere vulnerability in Rancher Desktop of SUSE allows attackers in the local network to connect to the Dashboard API (steve) to carry out arbitrary actions. This issue affects: SUSE Rancher Desktop versions prior to V.
CWE
  • CWE-668 - Exposure of Resource to Wrong Sphere
Assigner
References
Impacted products
Vendor Product Version
SUSE Rancher Affected: Desktop , < V (custom)
Create a notification for this product.
Date Public
2022-03-25 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:00:54.558Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://bugzilla.suse.com/show_bug.cgi?id=1197491"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Rancher",
          "vendor": "SUSE",
          "versions": [
            {
              "lessThan": "V",
              "status": "affected",
              "version": "Desktop",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-03-25T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A Exposure of Resource to Wrong Sphere vulnerability in Rancher Desktop of SUSE allows attackers in the local network to connect to the Dashboard API (steve) to carry out arbitrary actions. This issue affects: SUSE Rancher Desktop versions prior to V."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 8.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-668",
              "description": "CWE-668: Exposure of Resource to Wrong Sphere",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-06-29T00:00:00.000Z",
        "orgId": "404e59f5-483d-4b8a-8e7a-e67604dd8afb",
        "shortName": "suse"
      },
      "references": [
        {
          "url": "https://bugzilla.suse.com/show_bug.cgi?id=1197491"
        }
      ],
      "source": {
        "advisory": "https://bugzilla.suse.com/show_bug.cgi?id=1197491",
        "defect": [
          "1197491"
        ],
        "discovery": "INTERNAL"
      },
      "title": "rancher desktop: Dashboard API is network accessible",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "404e59f5-483d-4b8a-8e7a-e67604dd8afb",
    "assignerShortName": "suse",
    "cveId": "CVE-2022-21947",
    "datePublished": "2022-04-01T06:40:10.168Z",
    "dateReserved": "2021-12-16T00:00:00.000Z",
    "dateUpdated": "2024-09-16T19:20:21.598Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-22515 (GCVE-0-2022-22515)

Vulnerability from cvelistv5 – Published: 2022-04-07 18:21 – Updated: 2024-09-16 17:59
VLAI
Title
A component of the CODESYS Control runtime system allows read and write access to configuration files
Summary
A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products.
CWE
  • CWE-668 - Exposure of Resource to Wrong Sphere
Assigner
References
Impacted products
Vendor Product Version
CODESYS CODESYS Control RTE (SL) Affected: V3 , < V3.5.17.40 (custom)
Create a notification for this product.
CODESYS CODESYS Control RTE (for Beckhoff CX) SL Affected: V3 , < V3.5.17.40 (custom)
Create a notification for this product.
CODESYS CODESYS Control Win (SL) Affected: V3 , < V3.5.17.40 (custom)
Create a notification for this product.
CODESYS CODESYS HMI (SL) Affected: V3 , < V3.5.17.40 (custom)
Create a notification for this product.
CODESYS CODESYS Development System V3 Affected: V3 , < V3.5.17.40 (custom)
Create a notification for this product.
CODESYS CODESYS Control Runtime System Toolkit Affected: V3 , < V3.5.17.40 (custom)
Create a notification for this product.
CODESYS CODESYS Embedded Target Visu Toolkit Affected: V3 , < V3.5.17.40 (custom)
Create a notification for this product.
CODESYS CODESYS Remote Target Visu Toolkit Affected: V3 , < V3.5.17.40 (custom)
Create a notification for this product.
CODESYS CODESYS Control for BeagleBone SL Affected: V4 , < V4.5.0.0 (custom)
Create a notification for this product.
CODESYS CODESYS Control for Beckhoff CX9020 SL Affected: V4 , < V4.5.0.0 (custom)
Create a notification for this product.
CODESYS CODESYS Control for emPC-A/iMX6 SL Affected: V4 , < V4.5.0.0 (custom)
Create a notification for this product.
CODESYS CODESYS Control for IOT2000 SL Affected: V4 , < V4.5.0.0 (custom)
Create a notification for this product.
CODESYS CODESYS Control for Linux SL Affected: V4 , < V4.5.0.0 (custom)
Create a notification for this product.
CODESYS CODESYS Control for PFC100 SL Affected: V4 , < V4.5.0.0 (custom)
Create a notification for this product.
CODESYS CODESYS Control for PFC200 SL Affected: V4 , < V4.5.0.0 (custom)
Create a notification for this product.
CODESYS CODESYS Control for PLCnext SL Affected: V4 , < V4.5.0.0 (custom)
Create a notification for this product.
CODESYS CODESYS Control for Raspberry Pi SL Affected: V4 , < V4.5.0.0 (custom)
Create a notification for this product.
CODESYS CODESYS Control for WAGO Touch Panels 600 SL Affected: V4 , < V4.5.0.0 (custom)
Create a notification for this product.
Date Public
2022-06-01 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:14:55.437Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17089\u0026token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53\u0026download="
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "CODESYS Control RTE (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.17.40",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control RTE (for Beckhoff CX) SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.17.40",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control Win (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.17.40",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS HMI (SL)",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.17.40",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Development System V3",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.17.40",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control Runtime System Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.17.40",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Embedded Target Visu Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.17.40",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Remote Target Visu Toolkit",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V3.5.17.40",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for BeagleBone SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Beckhoff CX9020 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for emPC-A/iMX6 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for IOT2000 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Linux SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PFC100 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PFC200 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for PLCnext SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for Raspberry Pi SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "CODESYS Control for WAGO Touch Panels 600 SL",
          "vendor": "CODESYS",
          "versions": [
            {
              "lessThan": "V4.5.0.0",
              "status": "affected",
              "version": "V4",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-06-01T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-668",
              "description": "CWE-668 Exposure of Resource to Wrong Sphere",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-12T07:45:29.000Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17089\u0026token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53\u0026download="
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "A component of the CODESYS Control runtime system allows read and write access to configuration files",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "info@cert.vde.com",
          "DATE_PUBLIC": "2022-06-01T10:00:00.000Z",
          "ID": "CVE-2022-22515",
          "STATE": "PUBLIC",
          "TITLE": "A component of the CODESYS Control runtime system allows read and write access to configuration files"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "CODESYS Control RTE (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.17.40"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control RTE (for Beckhoff CX) SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.17.40"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control Win (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.17.40"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS HMI (SL)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.17.40"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Development System V3",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.17.40"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control Runtime System Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.17.40"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Embedded Target Visu Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.17.40"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Remote Target Visu Toolkit",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V3",
                            "version_value": "V3.5.17.40"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for BeagleBone SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Beckhoff CX9020 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for emPC-A/iMX6 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for IOT2000 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Linux SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PFC100 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PFC200 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for PLCnext SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for Raspberry Pi SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CODESYS Control for WAGO Touch Panels 600 SL",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V4",
                            "version_value": "V4.5.0.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "CODESYS"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-668 Exposure of Resource to Wrong Sphere"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17089\u0026token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53\u0026download=",
              "refsource": "CONFIRM",
              "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17089\u0026token=cc5041e24fc744a397a6f6e3b78200a40e6fcd53\u0026download="
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2022-22515",
    "datePublished": "2022-04-07T18:21:16.280Z",
    "dateReserved": "2022-01-03T00:00:00.000Z",
    "dateUpdated": "2024-09-16T17:59:22.215Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-22732 (GCVE-0-2022-22732)

Vulnerability from cvelistv5 – Published: 2023-01-30 00:00 – Updated: 2025-02-05 20:08
VLAI
Summary
A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that could cause all remote domains to access the resources (data) supplied by the server when an attacker sends a fetch request from third-party site or malicious site. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22)
CWE
  • CWE-668 - Exposure of Resource to Wrong Sphere
Assigner
Impacted products
Vendor Product Version
Schneider Electric EcoStruxure Power Commission Affected: All , < V2.22 (custom)
Create a notification for this product.
Date Public
2022-06-14 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:21:48.946Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-05_EcoStruxure_Power_Commission_Security_Notification.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-22732",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-05T19:50:45.469109Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-05T20:08:57.280Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "EcoStruxure Power Commission",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "lessThan": "V2.22",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-06-14T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that could cause all remote domains to access the resources (data) supplied by the server when an attacker sends a fetch request from third-party site or malicious site. Affected Products: EcoStruxure Power Commission (Versions prior to V2.22)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 3.9,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-668",
              "description": "CWE-668 Exposure of Resource to Wrong Sphere",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-01-30T00:00:00.000Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-05_EcoStruxure_Power_Commission_Security_Notification.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2022-22732",
    "datePublished": "2023-01-30T00:00:00.000Z",
    "dateReserved": "2022-01-06T00:00:00.000Z",
    "dateUpdated": "2025-02-05T20:08:57.280Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-24074 (GCVE-0-2022-24074)

Vulnerability from cvelistv5 – Published: 2022-03-17 05:20 – Updated: 2024-08-03 03:59
VLAI
Summary
Whale Bridge, a default extension in Whale browser before 3.12.129.18, allowed to receive any SendMessage request from the content script itself that could lead to controlling Whale Bridge if the rendering process compromises.
Severity
No CVSS data available.
CWE
  • CWE-668 - Exposure of Resource to Wrong Sphere
Assigner
References
URL Tags
https://cve.naver.com/detail/cve-2022-24074 x_refsource_CONFIRM
Impacted products
Vendor Product Version
NAVER NAVER Whale browser Affected: unspecified , < 3.12.129.46 (custom)
Create a notification for this product.
Credits
Young Min Kim
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:59:23.649Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cve.naver.com/detail/cve-2022-24074"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "NAVER Whale browser",
          "vendor": "NAVER",
          "versions": [
            {
              "lessThan": "3.12.129.46",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Young Min Kim"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Whale Bridge, a default extension in Whale browser before 3.12.129.18, allowed to receive any SendMessage request from the content script itself that could lead to controlling Whale Bridge if the rendering process compromises."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-668",
              "description": "CWE-668: Exposure of Resource to Wrong Sphere",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-17T05:20:16.000Z",
        "orgId": "f9629fae-ca2e-4fbf-9785-3ed86476aef6",
        "shortName": "naver"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cve.naver.com/detail/cve-2022-24074"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@navercorp.com",
          "ID": "CVE-2022-24074",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "NAVER Whale browser",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "3.12.129.46"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "NAVER"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Young Min Kim"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Whale Bridge, a default extension in Whale browser before 3.12.129.18, allowed to receive any SendMessage request from the content script itself that could lead to controlling Whale Bridge if the rendering process compromises."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-668: Exposure of Resource to Wrong Sphere"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cve.naver.com/detail/cve-2022-24074",
              "refsource": "CONFIRM",
              "url": "https://cve.naver.com/detail/cve-2022-24074"
            }
          ]
        },
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f9629fae-ca2e-4fbf-9785-3ed86476aef6",
    "assignerShortName": "naver",
    "cveId": "CVE-2022-24074",
    "datePublished": "2022-03-17T05:20:16.000Z",
    "dateReserved": "2022-01-27T00:00:00.000Z",
    "dateUpdated": "2024-08-03T03:59:23.649Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-24823 (GCVE-0-2022-24823)

Vulnerability from cvelistv5 – Published: 2022-05-06 12:05 – Updated: 2025-04-22 18:01
VLAI
Title
Local Information Disclosure Vulnerability in io.netty:netty-codec-http
Summary
Netty is an open-source, asynchronous event-driven network application framework. The package `io.netty:netty-codec-http` prior to version 4.1.77.Final contains an insufficient fix for CVE-2021-21290. When Netty's multipart decoders are used local information disclosure can occur via the local system temporary directory if temporary storing uploads on the disk is enabled. This only impacts applications running on Java version 6 and lower. Additionally, this vulnerability impacts code running on Unix-like systems, and very old versions of Mac OSX and Windows as they all share the system temporary directory between all users. Version 4.1.77.Final contains a patch for this vulnerability. As a workaround, specify one's own `java.io.tmpdir` when starting the JVM or use DefaultHttpDataFactory.setBaseDir(...) to set the directory to something that is only readable by the current user.
CWE
  • CWE-668 - Exposure of Resource to Wrong Sphere
  • CWE-378 - Creation of Temporary File With Insecure Permissions
  • CWE-379 - Creation of Temporary File in Directory with Insecure Permissions
Assigner
Impacted products
Vendor Product Version
netty netty Affected: <= 4.1.76.Final
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:20:50.545Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://github.com/netty/netty/security/advisories/GHSA-269q-hmxg-m83q"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/netty/netty/security/advisories/GHSA-5mcr-gq6c-3hq2"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/netty/netty/commit/185f8b2756a36aaa4f973f1a2a025e7d981823f1"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20220616-0004/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-24823",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-22T15:48:11.887598Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-22T18:01:57.607Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "netty",
          "vendor": "netty",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c= 4.1.76.Final"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Netty is an open-source, asynchronous event-driven network application framework. The package `io.netty:netty-codec-http` prior to version 4.1.77.Final contains an insufficient fix for CVE-2021-21290. When Netty\u0027s multipart decoders are used local information disclosure can occur via the local system temporary directory if temporary storing uploads on the disk is enabled. This only impacts applications running on Java version 6 and lower. Additionally, this vulnerability impacts code running on Unix-like systems, and very old versions of Mac OSX and Windows as they all share the system temporary directory between all users. Version 4.1.77.Final contains a patch for this vulnerability. As a workaround, specify one\u0027s own `java.io.tmpdir` when starting the JVM or use DefaultHttpDataFactory.setBaseDir(...) to set the directory to something that is only readable by the current user."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-668",
              "description": "CWE-668: Exposure of Resource to Wrong Sphere",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-378",
              "description": "CWE-378: Creation of Temporary File With Insecure Permissions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-379",
              "description": "CWE-379: Creation of Temporary File in Directory with Insecure Permissions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-07-25T16:52:21.000Z",
        "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "shortName": "GitHub_M"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://github.com/netty/netty/security/advisories/GHSA-269q-hmxg-m83q"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/netty/netty/security/advisories/GHSA-5mcr-gq6c-3hq2"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/netty/netty/commit/185f8b2756a36aaa4f973f1a2a025e7d981823f1"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20220616-0004/"
        }
      ],
      "source": {
        "advisory": "GHSA-269q-hmxg-m83q",
        "discovery": "UNKNOWN"
      },
      "title": "Local Information Disclosure Vulnerability in io.netty:netty-codec-http",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-advisories@github.com",
          "ID": "CVE-2022-24823",
          "STATE": "PUBLIC",
          "TITLE": "Local Information Disclosure Vulnerability in io.netty:netty-codec-http"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "netty",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "\u003c= 4.1.76.Final"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "netty"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Netty is an open-source, asynchronous event-driven network application framework. The package `io.netty:netty-codec-http` prior to version 4.1.77.Final contains an insufficient fix for CVE-2021-21290. When Netty\u0027s multipart decoders are used local information disclosure can occur via the local system temporary directory if temporary storing uploads on the disk is enabled. This only impacts applications running on Java version 6 and lower. Additionally, this vulnerability impacts code running on Unix-like systems, and very old versions of Mac OSX and Windows as they all share the system temporary directory between all users. Version 4.1.77.Final contains a patch for this vulnerability. As a workaround, specify one\u0027s own `java.io.tmpdir` when starting the JVM or use DefaultHttpDataFactory.setBaseDir(...) to set the directory to something that is only readable by the current user."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-668: Exposure of Resource to Wrong Sphere"
                }
              ]
            },
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-378: Creation of Temporary File With Insecure Permissions"
                }
              ]
            },
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-379: Creation of Temporary File in Directory with Insecure Permissions"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/netty/netty/security/advisories/GHSA-269q-hmxg-m83q",
              "refsource": "CONFIRM",
              "url": "https://github.com/netty/netty/security/advisories/GHSA-269q-hmxg-m83q"
            },
            {
              "name": "https://github.com/netty/netty/security/advisories/GHSA-5mcr-gq6c-3hq2",
              "refsource": "MISC",
              "url": "https://github.com/netty/netty/security/advisories/GHSA-5mcr-gq6c-3hq2"
            },
            {
              "name": "https://github.com/netty/netty/commit/185f8b2756a36aaa4f973f1a2a025e7d981823f1",
              "refsource": "MISC",
              "url": "https://github.com/netty/netty/commit/185f8b2756a36aaa4f973f1a2a025e7d981823f1"
            },
            {
              "name": "https://www.oracle.com/security-alerts/cpujul2022.html",
              "refsource": "MISC",
              "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
            },
            {
              "name": "https://security.netapp.com/advisory/ntap-20220616-0004/",
              "refsource": "CONFIRM",
              "url": "https://security.netapp.com/advisory/ntap-20220616-0004/"
            }
          ]
        },
        "source": {
          "advisory": "GHSA-269q-hmxg-m83q",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
    "assignerShortName": "GitHub_M",
    "cveId": "CVE-2022-24823",
    "datePublished": "2022-05-06T12:05:11.000Z",
    "dateReserved": "2022-02-10T00:00:00.000Z",
    "dateUpdated": "2025-04-22T18:01:57.607Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-26355 (GCVE-0-2022-26355)

Vulnerability from cvelistv5 – Published: 2022-03-09 14:58 – Updated: 2024-08-03 05:03
VLAI
Title
Citrix Federated Authentication Service (FAS)
Summary
Citrix Federated Authentication Service (FAS) 7.17 - 10.6 causes deployments that have been configured to store a registration authority certificate's private key in a Trusted Platform Module (TPM) to incorrectly store that key in the Microsoft Software Key Storage Provider (MSKSP). This issue only occurs if PowerShell was used when configuring FAS to store the registration authority certificate’s private key in the TPM. It does not occur if the TPM was not selected for use or if the FAS administration console was used for configuration.
Severity
No CVSS data available.
CWE
  • CWE-668 - Exposure of Resource to Wrong Sphere
Assigner
References
Impacted products
Vendor Product Version
Citrix Federated Authentication Service (FAS) Affected: unspecified , ≤ 10.6 (custom)
Affected: 7.17 , < unspecified (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:03:32.904Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.citrix.com/article/CTX341587"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Federated Authentication Service (FAS)",
          "vendor": "Citrix",
          "versions": [
            {
              "lessThanOrEqual": "10.6",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            },
            {
              "lessThan": "unspecified",
              "status": "affected",
              "version": "7.17",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Citrix Federated Authentication Service (FAS) 7.17 - 10.6 causes deployments that have been configured to store a registration authority certificate\u0027s private key in a Trusted Platform Module (TPM) to incorrectly store that key in the Microsoft Software Key Storage Provider (MSKSP). This issue only occurs if PowerShell was used when configuring FAS to store the registration authority certificate\u2019s private key in the TPM. It does not occur if the TPM was not selected for use or if the FAS administration console was used for configuration."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-668",
              "description": "CWE-668 Exposure of Resource to Wrong Sphere",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-09T14:58:02.000Z",
        "orgId": "e437aed5-38e0-4fa3-a98b-cb73e7acaec6",
        "shortName": "Citrix"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.citrix.com/article/CTX341587"
        }
      ],
      "source": {
        "advisory": "CTX341587",
        "discovery": "UNKNOWN"
      },
      "title": "Citrix Federated Authentication Service (FAS)",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@citrix.com",
          "ID": "CVE-2022-26355",
          "STATE": "PUBLIC",
          "TITLE": "Citrix Federated Authentication Service (FAS)"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Federated Authentication Service (FAS)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "10.6"
                          },
                          {
                            "version_affected": "\u003e=",
                            "version_value": "7.17"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Citrix"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Citrix Federated Authentication Service (FAS) 7.17 - 10.6 causes deployments that have been configured to store a registration authority certificate\u0027s private key in a Trusted Platform Module (TPM) to incorrectly store that key in the Microsoft Software Key Storage Provider (MSKSP). This issue only occurs if PowerShell was used when configuring FAS to store the registration authority certificate\u2019s private key in the TPM. It does not occur if the TPM was not selected for use or if the FAS administration console was used for configuration."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-668 Exposure of Resource to Wrong Sphere"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.citrix.com/article/CTX341587",
              "refsource": "MISC",
              "url": "https://support.citrix.com/article/CTX341587"
            }
          ]
        },
        "source": {
          "advisory": "CTX341587",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e437aed5-38e0-4fa3-a98b-cb73e7acaec6",
    "assignerShortName": "Citrix",
    "cveId": "CVE-2022-26355",
    "datePublished": "2022-03-09T14:58:02.000Z",
    "dateReserved": "2022-03-02T00:00:00.000Z",
    "dateUpdated": "2024-08-03T05:03:32.904Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-29247 (GCVE-0-2022-29247)

Vulnerability from cvelistv5 – Published: 2022-06-13 21:05 – Updated: 2025-04-23 18:16
VLAI
Title
Exposure of Resource to Wrong Sphere in Electron
Summary
Electron is a framework for writing cross-platform desktop applications using JavaScript (JS), HTML, and CSS. A vulnerability in versions prior to 18.0.0-beta.6, 17.2.0, 16.2.6, and 15.5.5 allows a renderer with JS execution to obtain access to a new renderer process with `nodeIntegrationInSubFrames` enabled which in turn allows effective access to `ipcRenderer`. The `nodeIntegrationInSubFrames` option does not implicitly grant Node.js access. Rather, it depends on the existing sandbox setting. If an application is sandboxed, then `nodeIntegrationInSubFrames` just gives access to the sandboxed renderer APIs, which include `ipcRenderer`. If the application then additionally exposes IPC messages without IPC `senderFrame` validation that perform privileged actions or return confidential data this access to `ipcRenderer` can in turn compromise your application / user even with the sandbox enabled. Electron versions 18.0.0-beta.6, 17.2.0, 16.2.6, and 15.5.5 contain a fix for this issue. As a workaround, ensure that all IPC message handlers appropriately validate `senderFrame`.
CWE
  • CWE-668 - Exposure of Resource to Wrong Sphere
Assigner
References
Impacted products
Vendor Product Version
electron electron Affected: < 15.5.5
Affected: >= 16.0.0-beta.1, < 16.2.6
Affected: >= 17.0.0-beta.1, < 17.2.0
Affected: >= 18.0.0-beta.1, <= 18.0.0-beta.5
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:17:54.477Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://github.com/electron/electron/security/advisories/GHSA-mq8j-3h7h-p8g7"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-29247",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-23T14:05:29.437546Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-23T18:16:29.296Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "electron",
          "vendor": "electron",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c 15.5.5"
            },
            {
              "status": "affected",
              "version": "\u003e= 16.0.0-beta.1, \u003c 16.2.6"
            },
            {
              "status": "affected",
              "version": "\u003e= 17.0.0-beta.1, \u003c 17.2.0"
            },
            {
              "status": "affected",
              "version": "\u003e= 18.0.0-beta.1, \u003c= 18.0.0-beta.5"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Electron is a framework for writing cross-platform desktop applications using JavaScript (JS), HTML, and CSS. A vulnerability in versions prior to 18.0.0-beta.6, 17.2.0, 16.2.6, and 15.5.5 allows a renderer with JS execution to obtain access to a new renderer process with `nodeIntegrationInSubFrames` enabled which in turn allows effective access to `ipcRenderer`. The `nodeIntegrationInSubFrames` option does not implicitly grant Node.js access. Rather, it depends on the existing sandbox setting. If an application is sandboxed, then `nodeIntegrationInSubFrames` just gives access to the sandboxed renderer APIs, which include `ipcRenderer`. If the application then additionally exposes IPC messages without IPC `senderFrame` validation that perform privileged actions or return confidential data this access to `ipcRenderer` can in turn compromise your application / user even with the sandbox enabled. Electron versions 18.0.0-beta.6, 17.2.0, 16.2.6, and 15.5.5 contain a fix for this issue. As a workaround, ensure that all IPC message handlers appropriately validate `senderFrame`."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 2.2,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-668",
              "description": "CWE-668: Exposure of Resource to Wrong Sphere",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-06-13T21:05:10.000Z",
        "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "shortName": "GitHub_M"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://github.com/electron/electron/security/advisories/GHSA-mq8j-3h7h-p8g7"
        }
      ],
      "source": {
        "advisory": "GHSA-mq8j-3h7h-p8g7",
        "discovery": "UNKNOWN"
      },
      "title": "Exposure of Resource to Wrong Sphere in Electron",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-advisories@github.com",
          "ID": "CVE-2022-29247",
          "STATE": "PUBLIC",
          "TITLE": "Exposure of Resource to Wrong Sphere in Electron"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "electron",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "\u003c 15.5.5"
                          },
                          {
                            "version_value": "\u003e= 16.0.0-beta.1, \u003c 16.2.6"
                          },
                          {
                            "version_value": "\u003e= 17.0.0-beta.1, \u003c 17.2.0"
                          },
                          {
                            "version_value": "\u003e= 18.0.0-beta.1, \u003c= 18.0.0-beta.5"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "electron"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Electron is a framework for writing cross-platform desktop applications using JavaScript (JS), HTML, and CSS. A vulnerability in versions prior to 18.0.0-beta.6, 17.2.0, 16.2.6, and 15.5.5 allows a renderer with JS execution to obtain access to a new renderer process with `nodeIntegrationInSubFrames` enabled which in turn allows effective access to `ipcRenderer`. The `nodeIntegrationInSubFrames` option does not implicitly grant Node.js access. Rather, it depends on the existing sandbox setting. If an application is sandboxed, then `nodeIntegrationInSubFrames` just gives access to the sandboxed renderer APIs, which include `ipcRenderer`. If the application then additionally exposes IPC messages without IPC `senderFrame` validation that perform privileged actions or return confidential data this access to `ipcRenderer` can in turn compromise your application / user even with the sandbox enabled. Electron versions 18.0.0-beta.6, 17.2.0, 16.2.6, and 15.5.5 contain a fix for this issue. As a workaround, ensure that all IPC message handlers appropriately validate `senderFrame`."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 2.2,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-668: Exposure of Resource to Wrong Sphere"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/electron/electron/security/advisories/GHSA-mq8j-3h7h-p8g7",
              "refsource": "CONFIRM",
              "url": "https://github.com/electron/electron/security/advisories/GHSA-mq8j-3h7h-p8g7"
            }
          ]
        },
        "source": {
          "advisory": "GHSA-mq8j-3h7h-p8g7",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
    "assignerShortName": "GitHub_M",
    "cveId": "CVE-2022-29247",
    "datePublished": "2022-06-13T21:05:10.000Z",
    "dateReserved": "2022-04-13T00:00:00.000Z",
    "dateUpdated": "2025-04-23T18:16:29.296Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-31596 (GCVE-0-2022-31596)

Vulnerability from cvelistv5 – Published: 2022-12-12 03:43 – Updated: 2025-04-22 17:56
VLAI
Summary
Under certain conditions, an attacker authenticated as a CMS administrator and with high privileges access to the Network in SAP BusinessObjects Business Intelligence Platform (Monitoring DB) - version 430, can access BOE Monitoring database to retrieve and modify (non-personal) system data which would otherwise be restricted. Also, a potential attack could be used to leave the CMS's scope and impact the database. A successful attack could have a low impact on confidentiality, a high impact on integrity, and a low impact on availability.
CWE
  • CWE-668 - Exposure of Resource to Wrong Sphere
Assigner
sap
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T07:25:59.498Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://launchpad.support.sap.com/#/notes/3213507"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.sap.com/documents/2022/02/fa865ea4-167e-0010-bca6-c68f7e60039b.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 6,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "HIGH",
              "privilegesRequired": "HIGH",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:H/A:L",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2022-31596",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-22T17:56:14.348501Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-22T17:56:56.877Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SAP Business Objects Platform (Monitoring DB) ",
          "vendor": "SAP",
          "versions": [
            {
              "status": "affected",
              "version": "430"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cp\u003eUnder certain conditions, an attacker authenticated as a CMS administrator and with high privileges access to the Network in SAP BusinessObjects Business Intelligence Platform (Monitoring DB) - version 430, can access BOE Monitoring database to retrieve and modify (non-personal) system data which would otherwise be restricted. Also, a potential attack could be used to leave the CMS\u0027s scope and impact the database. \u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003eA successful attack could have a low impact on confidentiality, a high impact on integrity, and a low impact on availability.\u003c/p\u003e\u003c/div\u003e"
            }
          ],
          "value": "Under certain conditions, an attacker authenticated as a CMS administrator and with high privileges access to the Network in SAP BusinessObjects Business Intelligence Platform (Monitoring DB) - version 430, can access BOE Monitoring database to retrieve and modify (non-personal) system data which would otherwise be restricted. Also, a potential attack could be used to leave the CMS\u0027s scope and impact the database. \n\n\n\nA successful attack could have a low impact on confidentiality, a high impact on integrity, and a low impact on availability.\n\n\n\n"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-668",
              "description": "CWE-668 Exposure of Resource to Wrong Sphere",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-12T05:27:19.191Z",
        "orgId": "e4686d1a-f260-4930-ac4c-2f5c992778dd",
        "shortName": "sap"
      },
      "references": [
        {
          "url": "https://launchpad.support.sap.com/#/notes/3213507"
        },
        {
          "url": "https://www.sap.com/documents/2022/02/fa865ea4-167e-0010-bca6-c68f7e60039b.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e4686d1a-f260-4930-ac4c-2f5c992778dd",
    "assignerShortName": "sap",
    "cveId": "CVE-2022-31596",
    "datePublished": "2022-12-12T03:43:40.155Z",
    "dateReserved": "2022-05-24T03:09:38.744Z",
    "dateUpdated": "2025-04-22T17:56:56.877Z",
    "requesterUserId": "048f1e0a-8756-40de-bd1f-51292c7183c7",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-32249 (GCVE-0-2022-32249)

Vulnerability from cvelistv5 – Published: 2022-07-12 20:31 – Updated: 2024-08-03 07:39
VLAI
Summary
Under special integration scenario of SAP Business one and SAP HANA - version 10.0, an attacker can exploit HANA cockpit�s data volume to gain access to highly sensitive information (e.g., high privileged account credentials)
Severity
No CVSS data available.
CWE
Assigner
sap
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T07:39:49.591Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.sap.com/documents/2022/02/fa865ea4-167e-0010-bca6-c68f7e60039b.html"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://launchpad.support.sap.com/#/notes/3212997"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SAP Business one",
          "vendor": "SAP SE",
          "versions": [
            {
              "status": "affected",
              "version": "10.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Under special integration scenario of SAP Business one and SAP HANA - version 10.0, an attacker can exploit HANA cockpit\ufffds data volume to gain access to highly sensitive information (e.g., high privileged account credentials)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-668",
              "description": "CWE-668",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-07-12T20:31:35.000Z",
        "orgId": "e4686d1a-f260-4930-ac4c-2f5c992778dd",
        "shortName": "sap"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.sap.com/documents/2022/02/fa865ea4-167e-0010-bca6-c68f7e60039b.html"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://launchpad.support.sap.com/#/notes/3212997"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cna@sap.com",
          "ID": "CVE-2022-32249",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SAP Business one",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "10.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "SAP SE"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Under special integration scenario of SAP Business one and SAP HANA - version 10.0, an attacker can exploit HANA cockpit\ufffds data volume to gain access to highly sensitive information (e.g., high privileged account credentials)"
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": "null",
            "vectorString": "null",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-668"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.sap.com/documents/2022/02/fa865ea4-167e-0010-bca6-c68f7e60039b.html",
              "refsource": "MISC",
              "url": "https://www.sap.com/documents/2022/02/fa865ea4-167e-0010-bca6-c68f7e60039b.html"
            },
            {
              "name": "https://launchpad.support.sap.com/#/notes/3212997",
              "refsource": "MISC",
              "url": "https://launchpad.support.sap.com/#/notes/3212997"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e4686d1a-f260-4930-ac4c-2f5c992778dd",
    "assignerShortName": "sap",
    "cveId": "CVE-2022-32249",
    "datePublished": "2022-07-12T20:31:35.000Z",
    "dateReserved": "2022-06-02T00:00:00.000Z",
    "dateUpdated": "2024-08-03T07:39:49.591Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-32530 (GCVE-0-2022-32530)

Vulnerability from cvelistv5 – Published: 2022-06-24 13:00 – Updated: 2024-08-03 07:46
VLAI
Summary
A CWE-668 Exposure of Resource to Wrong Sphere vulnerability exists that could cause users to be misled, hiding alarms, showing the wrong server connection option or the wrong control request when a mobile device has been compromised by a malicious application. Affected Product: Geo SCADA Mobile (Build 222 and prior)
CWE
  • CWE-668 - Exposure of Resource to Wrong Sphere
Assigner
References
Impacted products
Vendor Product Version
Schneider Electric Geo SCADA Mobile Affected: Build , ≤ 222 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T07:46:43.411Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-02_Geo_SCADA_Android_App_Security_Notification.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Geo SCADA Mobile",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "lessThanOrEqual": "222",
              "status": "affected",
              "version": "Build",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-668 Exposure of Resource to Wrong Sphere vulnerability exists that could cause users to be misled, hiding alarms, showing the wrong server connection option or the wrong control request when a mobile device has been compromised by a malicious application. Affected Product: Geo SCADA Mobile (Build 222 and prior)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 4.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-668",
              "description": "CWE-668 Exposure of Resource to Wrong Sphere",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-06-24T13:00:17.000Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-02_Geo_SCADA_Android_App_Security_Notification.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "ID": "CVE-2022-32530",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Geo SCADA Mobile",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "Build",
                            "version_value": "222"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Schneider Electric"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A CWE-668 Exposure of Resource to Wrong Sphere vulnerability exists that could cause users to be misled, hiding alarms, showing the wrong server connection option or the wrong control request when a mobile device has been compromised by a malicious application. Affected Product: Geo SCADA Mobile (Build 222 and prior)"
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 4.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-668 Exposure of Resource to Wrong Sphere"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-02_Geo_SCADA_Android_App_Security_Notification.pdf",
              "refsource": "MISC",
              "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-165-02_Geo_SCADA_Android_App_Security_Notification.pdf"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2022-32530",
    "datePublished": "2022-06-24T13:00:17.000Z",
    "dateReserved": "2022-06-07T00:00:00.000Z",
    "dateUpdated": "2024-08-03T07:46:43.411Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

No mitigation information available for this CWE.

No CAPEC attack patterns related to this CWE.

Back to CWE stats page