4 vulnerabilities found for Modicon M580 CPU (part numbers BMEP* and BMEH*, excluding M580 CPU Safety) by Schneider Electric
CVE-2024-11425 (GCVE-0-2024-11425)
Vulnerability from cvelistv5 – Published: 2025-01-17 09:00 – Updated: 2025-02-12 17:09
VLAI?
Summary
CWE-131: Incorrect Calculation of Buffer Size vulnerability exists that could cause Denial-of-Service of the
product when an unauthenticated user is sending a crafted HTTPS packet to the webserver.
Severity ?
CWE
- CWE-131 - Incorrect Calculation of Buffer Size
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | Modicon M580 CPU (part numbers BMEP* and BMEH*, excluding M580 CPU Safety) |
Affected:
Versions prior to SV4.30
|
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-11425",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-17T13:22:26.095314Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-12T17:09:38.349Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Modicon M580 CPU (part numbers BMEP* and BMEH*, excluding M580 CPU Safety)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions prior to SV4.30"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions prior to SV4.21"
}
]
},
{
"defaultStatus": "unaffected",
"product": "BMENOR2200H",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EVLink Pro AC",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions prior to v1.3.10"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-131: Incorrect Calculation of Buffer Size vulnerability exists that could cause Denial-of-Service of the\nproduct when an unauthenticated user is sending a crafted HTTPS packet to the webserver.\n\n\u003cbr\u003e"
}
],
"value": "CWE-131: Incorrect Calculation of Buffer Size vulnerability exists that could cause Denial-of-Service of the\nproduct when an unauthenticated user is sending a crafted HTTPS packet to the webserver."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-131",
"description": "CWE-131 Incorrect Calculation of Buffer Size",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-17T09:00:32.335Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2024-11425",
"datePublished": "2025-01-17T09:00:32.335Z",
"dateReserved": "2024-11-19T15:35:20.847Z",
"dateUpdated": "2025-02-12T17:09:38.349Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-6408 (GCVE-0-2023-6408)
Vulnerability from cvelistv5 – Published: 2024-02-14 16:52 – Updated: 2024-08-02 08:28
VLAI?
Summary
CWE-924: Improper Enforcement of Message Integrity During Transmission in a
Communication Channel vulnerability exists that could cause a denial of service and loss of
confidentiality, integrity of controllers when conducting a Man in the Middle attack.
Severity ?
8.1 (High)
CWE
- CWE-924 - Improper Enforcement of Message Integrity During Transmission in a Communication Channel
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | Modicon M340 CPU (part numbers BMXP34*) |
Affected:
Versions prior to sv3.60
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040c_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040s_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040c_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040s_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040c_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040s_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmep581020_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmep581020h_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmep582020_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmep582020h_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmep582040h_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmep582040s_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmep583020_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmep583040_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmep584020_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmep584040_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmep584040s_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmep585040c_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmep585040_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "modicon_m580_bmep585040_firmware",
"vendor": "schneider-electric",
"versions": [
{
"lessThan": "4.20",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:schneider-electric:modicon_m340_bmxp341000_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmxp341000h_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmxp342000_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420102cl_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420102_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmx_p34-2010_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmxp342010_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmxp342020_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmxp342020h_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302cl_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302h_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmx_p34-2030_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmxp342030_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmxp342030h_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "modicon_m340_bmxp342030h_firmware",
"vendor": "schneider-electric",
"versions": [
{
"lessThan": "3.60",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040c_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040s_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040c_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040s_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040c_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040s_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "modicon_m580_bmeh586040s_firmware",
"vendor": "schneider-electric",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-6408",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-17T19:15:41.696437Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-17T19:36:47.656Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T08:28:21.776Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-044-01.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Modicon M340 CPU (part numbers BMXP34*)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions prior to sv3.60"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Modicon M580 CPU (part numbers BMEP* and BMEH*, excluding M580 CPU Safety)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions prior to sv4.20"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EcoStruxure Control Expert",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions prior to v16.0"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EcoStruxure Process Expert",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions prior to v2023"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nCWE-924: Improper Enforcement of Message Integrity During Transmission in a\nCommunication Channel vulnerability exists that could cause a denial of service and loss of\nconfidentiality, integrity of controllers when conducting a Man in the Middle attack.\n\n"
}
],
"value": "\nCWE-924: Improper Enforcement of Message Integrity During Transmission in a\nCommunication Channel vulnerability exists that could cause a denial of service and loss of\nconfidentiality, integrity of controllers when conducting a Man in the Middle attack.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-924",
"description": "CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-02-14T16:52:24.805Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-044-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2023-6408",
"datePublished": "2024-02-14T16:52:24.805Z",
"dateReserved": "2023-11-30T09:52:30.945Z",
"dateUpdated": "2024-08-02T08:28:21.776Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-11425 (GCVE-0-2024-11425)
Vulnerability from nvd – Published: 2025-01-17 09:00 – Updated: 2025-02-12 17:09
VLAI?
Summary
CWE-131: Incorrect Calculation of Buffer Size vulnerability exists that could cause Denial-of-Service of the
product when an unauthenticated user is sending a crafted HTTPS packet to the webserver.
Severity ?
CWE
- CWE-131 - Incorrect Calculation of Buffer Size
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | Modicon M580 CPU (part numbers BMEP* and BMEH*, excluding M580 CPU Safety) |
Affected:
Versions prior to SV4.30
|
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-11425",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-17T13:22:26.095314Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-12T17:09:38.349Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Modicon M580 CPU (part numbers BMEP* and BMEH*, excluding M580 CPU Safety)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions prior to SV4.30"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions prior to SV4.21"
}
]
},
{
"defaultStatus": "unaffected",
"product": "BMENOR2200H",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EVLink Pro AC",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions prior to v1.3.10"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-131: Incorrect Calculation of Buffer Size vulnerability exists that could cause Denial-of-Service of the\nproduct when an unauthenticated user is sending a crafted HTTPS packet to the webserver.\n\n\u003cbr\u003e"
}
],
"value": "CWE-131: Incorrect Calculation of Buffer Size vulnerability exists that could cause Denial-of-Service of the\nproduct when an unauthenticated user is sending a crafted HTTPS packet to the webserver."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-131",
"description": "CWE-131 Incorrect Calculation of Buffer Size",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-17T09:00:32.335Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-014-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-014-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2024-11425",
"datePublished": "2025-01-17T09:00:32.335Z",
"dateReserved": "2024-11-19T15:35:20.847Z",
"dateUpdated": "2025-02-12T17:09:38.349Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-6408 (GCVE-0-2023-6408)
Vulnerability from nvd – Published: 2024-02-14 16:52 – Updated: 2024-08-02 08:28
VLAI?
Summary
CWE-924: Improper Enforcement of Message Integrity During Transmission in a
Communication Channel vulnerability exists that could cause a denial of service and loss of
confidentiality, integrity of controllers when conducting a Man in the Middle attack.
Severity ?
8.1 (High)
CWE
- CWE-924 - Improper Enforcement of Message Integrity During Transmission in a Communication Channel
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Schneider Electric | Modicon M340 CPU (part numbers BMXP34*) |
Affected:
Versions prior to sv3.60
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040c_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040s_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040c_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040s_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040c_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040s_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmep581020_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmep581020h_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmep582020_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmep582020h_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmep582040h_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmep582040s_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmep583020_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmep583040_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmep584020_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmep584040_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmep584040s_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmep585040c_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmep585040_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "modicon_m580_bmep585040_firmware",
"vendor": "schneider-electric",
"versions": [
{
"lessThan": "4.20",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:schneider-electric:modicon_m340_bmxp341000_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmxp341000h_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmxp342000_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420102cl_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420102_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmx_p34-2010_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmxp342010_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmxp342020_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmxp342020h_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302cl_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302h_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmx_p34-2030_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmxp342030_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m340_bmxp342030h_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "modicon_m340_bmxp342030h_firmware",
"vendor": "schneider-electric",
"versions": [
{
"lessThan": "3.60",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040c_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040s_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040c_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040s_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040c_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040s_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "modicon_m580_bmeh586040s_firmware",
"vendor": "schneider-electric",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-6408",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-17T19:15:41.696437Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-17T19:36:47.656Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T08:28:21.776Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-044-01.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Modicon M340 CPU (part numbers BMXP34*)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions prior to sv3.60"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Modicon M580 CPU (part numbers BMEP* and BMEH*, excluding M580 CPU Safety)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions prior to sv4.20"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EcoStruxure Control Expert",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions prior to v16.0"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EcoStruxure Process Expert",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Versions prior to v2023"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nCWE-924: Improper Enforcement of Message Integrity During Transmission in a\nCommunication Channel vulnerability exists that could cause a denial of service and loss of\nconfidentiality, integrity of controllers when conducting a Man in the Middle attack.\n\n"
}
],
"value": "\nCWE-924: Improper Enforcement of Message Integrity During Transmission in a\nCommunication Channel vulnerability exists that could cause a denial of service and loss of\nconfidentiality, integrity of controllers when conducting a Man in the Middle attack.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-924",
"description": "CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-02-14T16:52:24.805Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-044-01.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2023-6408",
"datePublished": "2024-02-14T16:52:24.805Z",
"dateReserved": "2023-11-30T09:52:30.945Z",
"dateUpdated": "2024-08-02T08:28:21.776Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}